SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE

Similar documents
SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE

AUS X CONTROL UNIT... 4 OPERATING MODES DESCRIPTION AUTOMATIC... 4 MANUAL... 5 CONNECTION OF EXTERNAL CONTACTORS K1 and K2...

Dichiarazione CE di conformità EC declaration of conformity

HM1 Operator panel Installation and use

Dichiarazione CE di conformità EC declaration of conformity

PS3 CONTROL UNIT. for 4-wire ribbon switches, edges and mats. Instruction use and maintenance READ BEFORE ANY INSTALLATION

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

M1 module TERMINAL SIGNAL TYPE DESCRIPTION OPERATION

Installation and operation manual EPIC

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

This Errata Sheet contains corrections or changes made after the publication of this manual.

MODULAR SAFETY INTEGRATED CONTROLLER

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Dichiarazione CE di conformità EC declaration of conformity

SEQUENCER FOR DEDUSTING PLANTS

Number of input channels

USER MANUAL. WBI412F41 AC current transducer

MAXIMA+ Series Rotary Level Indicator

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

USER MANUAL. WBV412U01 AC voltage transducer

MAXIMA + Series ROTARY LEVEL CONTROL

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device

Electronic Temperature Controller. Instruction Manual Version

PHOTOELECTRIC BARRIER ULISSE UNC INSTALLATION, USE AND MAINTENANCE

USER MANUAL. WBI414F21 AC current transducer

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

MC 11 EB-2 Power supply cabinet with external bus, AC version

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Operating Instructions

Operating Instructions

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating Instructions Differential Pressure Transducer PS27

AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F)

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

LCI User Manual mantracourt.com

USERS MANUAL MINI ONE

onlinecomponents.com

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

SR103AM. User Information for SR103AM. Correct Use

HI ma Simulator

Model DPDT Switch Module

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

7032 Digital-Analog Multimeter

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

SR101A. User Information for SR101A. Correct Use

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

OPERATING INSTRUCTIONS

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

SMVector Additional I/O Module Installation and Operation Manual

ITEM ESM-BA301

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Original instructions JSHD4 AS-i Enabling device with safe AS-i input slave

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

Model 7026 (1x32) 2-wire Multiplexer

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

HI ma Simulator

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

MSR178DP. Description. Features. Specifications

TXM1.8RB. TX-I/O Blinds module

Tina 1A Blanking plug

EC2 EXPANSION CONTROLLER MODULE OPERATING INSTRUCTIONS

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Redundancy unit CP-A RU

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

HI HI HI HI Portable Microprocessor Thermistor Thermometers

Thomson Max Jac Electric Linear Actuator

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Model SPDT Switch Module

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Language of the manual

ACS-30-EU-MONI-RMM2-E

I/O SIGNAL CONDITIONER

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Machine Safety Switches

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

2-Way Wireless I/O Expander Installation Guide

RТTH DUAL ROOM SWITCH

Type Switching repeater. Safety manual

COGNEX. Checker SensorView. Quick Reference Guide

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

********SERVICE MANUAL******** MODELS:

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Transcription:

SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE This symbol indicates an important personal safety warning. Failure to comply with the warning may result in very high risk for exposed personnel. INTRODUCTION The AD SR0 is an accessory device for the interconnection of a photoelectric light curtain in a safety circuit. See details below about light curtain models, wiring, etc. When deciding on the safety category to be adopted, carefully consider the risks analysis of the machine. The module has been designed in particular for use with the REER light curtains of the Admiral AX, EOS4 (category 4), Vision VX, Vision VXL/MXL, EOS2 (category 2) series. Consult REER before using the interface with other light curtain models or safety devices. For safe use of the device, it is essential to read and understand the contents of this handbook. Failure to comply with the prescriptions indicated in this notice may result in very high risks for the operating personnel of the protected machine. INSTALLATION AND ELECTRICAL CONNECTIONS Install the AD SR0 safety relay in an environment with a protection rating of at least IP54. The AD SR0 safety relay must be supplied with a 24Vdc 20% power supply. The external power supply must comply with the standard EN 60204-1. ELECTRICAL CONNECTIONS The safety relay is equipped with three terminal boards for the connections to the light curtain and to the machine. CJ3 CJ2 CJ1 Figure 1 8 8540554 08/03/2016 Rev.13

CJ1 PIN NAME DESCRIPTION 1 FB Internal relays feedback 2 24VDC 24Vdc Power Supply 3 0VDC 0Vdc Power Supply 4 IN2 Light curtain static output 5 IN1 Light curtain static output CJ2 CJ3 PIN NOME PIN NOME 6 N.O. contact 9 N.O. contact 7 N.O. contact 10 N.O. contact 8 N.C. contact 11 N.C. contact Example of connection of the AD SR0 module with JANUS safety light curtain * : USE INTERFACE SUPPRESSOR Figure 2 9 8540554 08/03/2016 Rev.13

Example of connection of the AD SR0 module with AX / VX / VXL safety light curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with AX / VX / VXL safety light curtain in MANUAL operatione mode Connection of VXL Emitter (modification of the above schematics) * If the TEST function is not required by the application, connect pin 2 of the emitter to +24Vdc. 10 8540554 08/03/2016 Rev.13

Example of connection of the AD SR0 module with MXL safety light curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with MXL safety light curtain in MANUAL operatione mode 11 8540554 08/03/2016 Rev.13

Example of connection of the AD SR0 module with EOS4X safety light curtain in AUTOMATIC operatione mode Further details regarding connections can be found on each curtain technical manual. Characteristics of the output circuit. For the output circuit, the safety relay uses two guided contact safety relays. These relays are rated by the manufacturer for voltage and current values above those indicated in the technical data; however, to assure correct insulation and to avoid damage or premature aging, protect each output line with a 3,15A slow-blow fuse and check that load characteristics comply with the indications given in the technical data. Warnings regarding the connection cables. For light curtain/safety interface connections of more than 50m, cables with a cross-section of at least 1mm 2 must be used. It is good practice to separate the power supply of the safety relay from that of other electrical equipment (electrical motors, inverters, frequency variators) or other sources of disturbance. The path of the connection cables between the safety relay and the sensors, the connection referring to the feedback contact must be different from that of other power cables. 12 8540554 08/03/2016 Rev.13

TECHNICAL DATA Power supply Vdc 24 20% Power requirement W 1,5 max Response time ms 20 max Connections Max. length of connections m 100 Operating temperature C 0-55 Enclosure protection rating IP 20 Terminal block protection rating Terminal block with protection against reversal of polarity IP 2X Fastening Fast attachment to rail according to EN 50022-35 Dimensions (h x w x d) mm 101 x 35 x 120 Weight g 180 Output circuit Number of contacts 2N.O. - 1N.C. Max switching voltage 250Vac, 24Vdc Min switching voltage 10Vac, 10Vdc Max switching current 2 Min switching current 10mA@24Vdc Switching cyles (life) > 50 x 10 3 (el) / > 40 x 10 6 (mech) SAFETY DATA FEEDBACK CONNECTION ACTIVE FEEDBACK CONNECTION MISSING PFHd SFF MTTFd DCavg PFHd SFF MTTFd DCavg 8,16E-09 99,5% 71,02 99,0% tcycle1 4,60E-07 0,50 71,01738 0 tcycle1 6,78E-10 99,5% 851,50 98,9% tcycle2 AC15 (6A) 4,43E-09 0,52 851,5035 0 tcycle2 AC15 (6A) 4,35E-11 99,2% 13442,07 97,6% tcycle3 9,73E-11 0,69 13442,07 0 tcycle3 1,52E-09 99,5% 378,64 99,0% tcycle1 1,86E-08 0,51 378,6359 0 tcycle1 1,28E-10 99,4% 4523,66 98,5% tcycle2 AC15 (2A) 3,62E-10 0,58 4523,66 0 tcycle2 9,14E-12 99,0% 67522,13 91,9% tcycle3 1,74E-11 0,87 67522,13 0 tcycle3 AC15 (2A) tcycle1: 300s (one commutation every 5 minutes) tcycle2: 3600s (one commutation every hour) tcycle3: one commutation every day (PFHd according to IEC61508, MTTFd and DCavg according to ISO13849-1) 13 8540554 08/03/2016 Rev.13

WARRANTY ReeR warrants that each AD SR0 unit in new ex-factory condition, in conditions of normal use, is free of defects in the materials and of manufacturing defects for a period of 12 (twelve) months. In this period, ReeR undertakes to eliminate any faults in the product through repair or replacement of the faulty parts, completely free of charge as regards material and labor. However, ReeR reserves the right to replace the entire faulty appliance with another equivalent appliance or with the same characteristics instead of repairing this. Validity of this warranty is regulated by the following conditions: The user must inform ReeR of the fault within twelve months from the date of delivery of the product. The appliance and its components must be in the conditions in which they were delivered by ReeR. The serial numbers must be clearly legible. The fault or defect has not been caused directly or indirectly by: Improper use; Non-compliance with instructions for use; Carelessness, inexperience, incorrect maintenance; Repairs, modifications, adaptations not carried out by ReeR personnel, tampering, etc.; Accidents or impacts (also due to transportation or causes of force majeure); Other causes not to be ascribed to ReeR. Repairs will be carried out at the ReeR laboratories to which the material must be delivered or dispatched: transport risks and the risks of any damage or loss of the material during shipment are the responsibility of the user. All products and components replaced become the property of ReeR. ReeR does not recognize any other warranties or rights except for those specifically described above; therefore, no claims for damages may be submitted for expenses, interruption of business or other factors or circumstances in any way related to failure of the product or of one of its parts. Precise, complete compliance with all the rules, instructions and prohibitions indicated in this handbook is an essential requirement for correct functioning of the safety relay. ReeR s.p.a. therefore declines any responsibility for all and anything resulting from failure to comply, even partially, with such indications. Characteristics subject to change without notice. Total or partial reproduction is forbidden without the prior authorization of ReeR. 14 8540554 08/03/2016 Rev.13

Dichiarazione CE di conformità EC declaration of conformity REER SpA via Carcano 32 10153 Torino Italy Torino, 24/03/2016 dichiara che AD SR0 e AD SR0A sono Interfacce di Sicurezza realizzate in conformità alle seguenti Direttive Europee: declares that the AD SR0 and AD SR0A, Safety Interfaces comply with the following European Directives: 2006/42/EC "Direttiva Macchine" "Machine Directive" 2014/30/EU "Direttiva Compatibilità Elettromagnetica" "Electromagnetic Compatibility Directive" 2014/35/EU "Direttiva Bassa Tensione" "Low Voltage Directive" Carlo Pautasso Direttore Tecnico Technical Director Simone Scaravelli Amministratore Delegato Managing director 15 8540554 08/03/2016 Rev.13

ReeR S.p.A. 32 via Carcano 10153 Torino Italia Tel. +39/0112482215 r.a. Fax +39/011859867 Internet: www.reer.it e-mail: info@reer.it 16 8540554 08/03/2016 Rev.13