LCU-1S Liquid Control Unit User Manual English 中文

Similar documents
LCU-2S Liquid Supply System User Manual English

Z-380 Fazer Machine User Manual English

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic

Stage Fog Machine User Manual

Z-350 FAZER USER MANUAL

FT-20 Fire Training Fog Machine User Manual English

S-500 Snow Machine User Manual English

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

FT-20 Fire Training Fog Machine User Manual English

DarkFX Spot 670 User Manual English

SW-250 Wireless Control High Output Snow Machine User Manual

S-100X / S-200X Snow Machine User Manual

V1.0. Showven Technologies Co.,Ltd.

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

LOW FOG 3000 FT USER MANUAL. Version: 1.0. ROBE Lighting s.r.o. Czech Republic

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

Professional DMX Stage Backdrop

Power LED Beam 56 Narrow

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

User Manual for the Antari M-1 Mobile Fog Machine

User Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Octostrip ORDERCODE 42220

CS2 DMX Distribution Splitter

LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

Crossfire. User Manual. Order code: EQLED061

MICRON DJ Booth System with Overhead Kit & CW Starcloth

w w w. p r o l i g h t. c o. u k STAGE PAR 64

MANUAL. ENGLISH PowerBOX 3. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

DMX LED Starcloth Systems

LIGHT BRICK - 12 X 3W TRI-COLOUR

MICRON DJ Booth Tri-colour Starcloth

Multidim ORDERCODE 50391

order code: EQLED40 user manual

ENGLISH Single WDP-1

CDP 405 Digital Dimmer Pack

Antenna Distributor ORDERCODE D1444

ZEPHYR Compact Haze Machine

1 Channel Strobe Controller ORDERCODE 40226

Haze 800 DMX. User Guide. English

1 Channel Sliding Profile Dimmer ORDERCODE 50425

Quick Reference Guide

UV Spectra Batten 12 x 5W UV LEDs

Party Dimmer IEC ORDERCODE 50324

Colour Star Sky I DMX ORDERCODE 40341

Order code: EQLED53 User manual

LED BEAM MOVING HEAD FL x3W User Manual

User Manual DUO BEAM/RG

VBAR 270. User Manual. Version 1.2

Order code: EQLED60 USER MANUAL

PF LED Profile. User Manual

Blitzer Strobe. User Manual. Order code: EQLED366

Slimline CW & WW Series

ZF LED Zoom Fresnel. User Manual

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

UV Power Flood. User Manual. Order code: EQLED029

Robot Light V2. User Manual

IMPACT Order code: EQLED79

User Instructions. American DJ

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

RGB Power Batten. User Manual. Order code: EQLED032

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

English. Professional Light Controller USER'S MANUAL. Please read this manual carefully before use!

D-Pack 6 Classic ORDERCODE 50315

Light Brick ORDERCODE 50370

ITA100 MKII 100mW green DMX laser

Vector Beam White. User Manual. Order code: LEDJ265

TABLE OF CONTENTS. SM250 User Manual Rev. 4

TourPro RGBAW Stagebar USER MANUAL

Microbar COB System. User Manual. Order code: EQLED137

Quick Reference Guide

TRANSCENSION Show Control

OPERATION MANUAL FEATURES BEFORE USE SAFETY INSTRUCTIONS: JB SYSTEMS 1/6 COLOR JET

UP-1-1 Channel Dimmer. User manual. dimmer pack

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

UP-1-1 Channel Dimmer dimmer pack. user manual

Fusion Saber. User Manual. Order code: EQLED070

THANK YOU FOR YOUR PURCHASE! INDEX. Unpacking & Inspection...Page 2. Production Dimensions...Page 3. Safety Information...Page 5. Operation...

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

DS-2 RF DMX dimmer. user manual

Fire Fogger 1500 fog machine. user manual

Performer 18 RGBWA MKII

Snapshot. User Manual

ALO Duo Roll DMX LED barrel scanner with dual light source

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Blue Weapon Laser. User manual UK. Version 1.0

LED W RGBA User Manual

Snapshot. Data Stream 4 USER MANUAL

Gobo Projector XP 80W

FTP1 Single Channel LED DMX Driver

LED DANCING FLOOR User Manual

LED Dancefloor ORDERCODE 42300

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Hazer DHZ-660 USERS MANUAL

TA18 active subwoofer. user manual

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Transcription:

LCU-1S Liquid Control Unit User Manual English 中文 2016 Antari Lighting and Effects Ltd.

User Manual Safety Information Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine. If you have questions about how to operate the machine safely, please contact your local Antari dealer for help. Keep this device dry. Always connect to a grounded circuit to avoid risk of electrocution. Before connecting machine to power, always check voltage indicate on machine match to your local AC voltage. Do not use the machine if AC power voltage does not match. Disconnect the machine from AC power before servicing and when not in use. This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, immediately unplug the machine and contact your local Antari dealer for advice. No user serviceable and modifiable parts inside. Never try to repair this product, an unauthorized technician may cause damage or malfunction to the machine. For adult use only. Never leave the machine running unattended. Never add flammable liquid of any kind to the machine. Make sure there are no flammable materials close to the machine while operating. Only use Antari fluid. Other fluid may lead to machine malfunction. If the machine fails to work, unplug the machine and stop operation immediately. Contact your local Antari dealer for advise. Before transporting the machine, make sure the fluid tank is completely drained. Fog/Snow fluid may present health risks if swallowed. Do not drink fog fluid. Store it securely. In case of eye contact or if fluid is swallowed, immediately look for medical advice. 3

Unpacking and Inspection Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retrain the packing material for inspection. What is included: 1 x LCU-1S Liquid Control Unit 1 x Power Cord 1 x 4 Pin Data Connection Cable 1 x Fluid Tube 1 x Fluid Filter 1 x User Manual Product Dimensions 95.8 mm 202 mm 179 mm Product Overview LCD Control Panel Liquid Output XLR 3-Pin DMX Out / IN Control Output Control Input Power Inlet Main Power Switch 4

Setup and Installation Compatible Models LCU-1S is designed to use with Z-1200II, S-100X, S-200X and SW-250. Each model has a pre-programmed fluid flow rate to reach best performance. Fluid Connection From control unit to machines the fluid flow through 6mm tube. The machine is equipped with 4mm tube, use supplied 6 to 4mm adaptor to connect from end of fluid tube to machin fluid inlet. On the input of fluid to control unit fit provided filter to the end of fluid tube prevent obstacle entering the fluid line. Data Connection For data connection 4-pin connector is used. Connect the output of control unit with input of remote on the machine. 5

***Note: LCU-1S is designed to use with Z-1200II, S-100X, S-200X and SW-250. Can supply to one machine at a time. Operation Control Panel Operation The control unit can be operated with the onboard digital control interface. LCU-1S Standby Button Function [MENU] Scroll through setting menu [UP]/[TIMER] Up/Activate Timer function [DOWN]/[VOLUME] Down/Activate Volume function [STOP] Deactivate Timer/Volume function 6

Control Menu Interval XXX Sec Set interval from 5 to 200 seconds Duration XXX Sec Set duration from 1 to 200 seconds Timer Out 100% Set timer output from 1 to 100% Volume Out 100% Set output volume from 1 to 100% DMX512 Add:XXX Set DMX address from 1 to 512 Remote Type XXX Select remote SC-2 or Z-8 W-Model XXXX Select model to operate with S-100X, S-200X, Z-1200II IMPORTANT: Null can be used with any machine required supplying of liquid, and possible to supply multiple machines. In this mode the fluid pump is program to run at full capacity, which the output volume can be adjusted manually to match the supplied machines. Z-8 Remote Control Operation (Optional) To operate the Z-1200II by remote control, connect the remote to the 4 pin control input located on the rear of control unit. Z-8 remote offers manual, continous and timer operation. For timer mode use rotarty knob on top to set interval, duration and output volume. 7

SC-2 Remote Control Operation (Optional) Use SC-2 remote control for operation with S-100X/S-200X/SW-250. Set switch to on position to activate, and adjust the output volume by turning the rotary knob. DMX Connector Pin Assignment The machine provides a 3-pin XLR connector for DMX connection. The diagram below indicates pin assignment information. Pin Function 1 Ground 2 Data- 3 Data+ 8

DMX Operation Making the DMX Connection Connect the machine to a DMX controller or to one of the machines in the DMX chain. The machine uses a 3-pin XLR connector for DMX connection, the connector is located on the front of the machine. DMX Channel Function Channel Mode Channel Value Function 0-4 Off 1 1 Output volume from 5-255 1-100% Service and Maintenance Do not allow the machine to become contaminated. Only use a damp cloth to clean the casing. It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition. Fuse Replacement Disconnect AC power before replacing fuse. Only replace fuse with same type and rating. Step 1: Disconnect power cord from supply. 9

Step 2: Use a flat-head screwdriver to release fuse holder. Step 3: Replace fuse with exact same type and rating as indicated below. Step 4: Reinsert fuse holder. Fuse 120V = T2A 250V 230V = T1A 250V Error Messages System Error Indicates the power is not switch on. If above message shows on the display, switch on the power of control unit or contact your local Antari dealer for advise Technical Specifications Input voltage Fuse Control option DMX channels Power connection DMX data connection Remote control connection Dimension Dry weight Accessories (Optional) AC120V, 50/60Hz AC240V, 50/60Hz 120V = T2A 250V 240V = T1A 250V DMX 512, Cable remote, Manual, 1 channels, Output volume IEC 3-pin XLR 4-pin XLR L 202 x W 179 x H 95.8 mm 3.30 kg Z-8 remote control, SC-2 remote control 10

C08LCU1S0