NAT 8 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The industrial transmitter NAT 8 features the extremely robust and stable thin-film-on-steel sensor element from its well-proven predecessor NAT 8. In combination with the new inhouse developed ASIC TX it offers a wide temperature range up to C and triple over safety which makes it the perfect solution for a wide range of demanding applications. Applications Machine tools Hydraulics HVAC Refrigeration Process technology Water treatment Features Smallest design Completely welded steel sensor system without additional seals Excellent long-term stability High resistance to over Data sheet H70i 0/06 Technical Data Measuring principle Thin film on steel Accuracy @ C typ. ± 0. % FS typ. Measuring range Output signal 0.... to 0... 600 bar 0... 0 to 0... 700 psi... 0 ma 0... VDC... 6 VDC 0... 0 VDC 0..... VDC ratiometric Media temperature Ambient temperature 0 C... + C 0 C... + C (Cable PVC : - C... +60 C) (Cable PUR : -0 C... +70 C) Subject to change Trafag Sensors & Controls Switzerland Industriestrasse 8608 Bubikon Tel. + 9 Fax + 9 www.trafag.com trafag@trafag.com
NAT 8 Ordering information/type code Measuring range ) Pressure measurement range Over Burst 0.... 7. 0 7 0... 60 76 0... 6 8 00 77 0... 0 0 00 78 0... 6 8 00 79 0... 7 00 80 0... 0 0 00 8 0... 60 80 00 8 0... 00 00 00 8 0... 60 80 70 8 0... 0 70 000 7 0... 00 000 000 8 0... 600 00 00 86 Option P: Fivefold over 0..... 60 0... 0 00 6 0... 6 0 00 7 0... 0 0 00 8 0... 6 80 00 9 0... 00 60 0... 0 00 00 6 0... 60 00 00 6 0... 00 00 70 6 0... 60 800 000 6 Pressure measurement range [psi] Over [psi] Burst [psi] 0... 0 90 700 G 0... 0 0 80 G6 0... 00 00 0 G7 0... 0 0 00 G8 0... 00 600 00 GA 0... 0 70 00 G9 0... 00 900 000 HA 0... 00 00 000 H0 0... 00 00 000 H 0... 000 000 000 H 0... 00 00 7000 H 0... 000 6000 0000 H 0... 000 9000 00 G 0... 000 00 70 H 0... 700 870 9000 H6 8. XX XX XX XX XX XX Sensor Relative Pressure connection Electrical connection G/ male, seal: DIN 869 (accessories 6/6/8) 7 / NPT male 0 7/6-0UNF female SAE J with valve opener ) 7/6-0UNF SAE male, seal: accessory 6 R/ male ISO 7- (DIN 999) ) 9 R/8 male ISO 7- (DIN 999) ) 6 M0x male Male electrical plug, industrial standard, contact distance 9. mm, Mat. PA 0 Male electrical plug Mx, -pole, Mat. PA Male electrical plug Mx, -pole, Mat. PA Cable IP67, Mat. PVC 7) Cable IP67, Mat. PUR 7) Cable IP67, Mat. EPD Raychem FDR 7) 08 Output Signal output Load resistance I (supply) U (supply)... 0mA See graphic (9... ) VDC 9 0... VDC.0 kω to Us- 0 ma (9... ) VDC... 6 VDC.0 kω to Us- 0 ma (9... ) VDC 6 0... 0 VDC.0 kω to Us- ma (... ) VDC 7 0..... VDC ratiometric.0 kω to Us- 0 ma (.7....) H70i page /6
NAT 8 8. XX XX XX XX XX XX Accessories Female electrical plug Mx, -pole ) Female electrical connector industrial standard ) Pressure peak damping element ø.0 mm 6) 0 Pressure peak damping element ø 0. mm 6) Seal FPM, -8 C... + C 6 Seal EPDM, -0 C... + C 6 Seal NBR, - C... +00 C 8 Special pin configuration: Pin : +, Pin : Ground, Pin : - (Only for output signal 9 and male electrical plug 0, industrial standard) 90 Special pin configuration: Pin : Out, Pin : +, Pin : Ground, Pin : - (Only for output signals, 6, 7, and male electrical plug 0, industrial standard) 9 Special pin configuration: Pin : +, Pin : Ground, Pin : -, Pin : Out (Only for output signals, 6, 7, and male electrical plug, Mx, -pole) 96 Special pin configuration: Pin : +, Pin : -, Pin : Ground (Only for output signal 9 and male electrical plug, Mx, -pole) E Special pin configuration: Pin : +, Pin : -, Pin : Out, Pin : Ground (Only for output signals, 6, 7, and male electrical plug, Mx, -pole) E Cable length 0. m EM Cable length.0 m M Cable length.0 m M ) Customized ranges upon request ) For electrical connections and ) For electrical connection 0 ) Max. allowable over 0 bar ) Max. allowable over 00 bar 6) Only for connections 7, 0, 7) Cable length see accessories Standard products (extra short lead time) Product No. Type Code Pressure range Over max. Supply [VDC] Accuracy @ C typ. [%] NAT.A 8 7 7 0 0000 0000 9 6 0.... 7. 9... ±0. NAT.0A 8 76 7 0 0000 0000 9 6 0... 9... ±0. NAT6.0A 8 77 7 0 0000 0000 9 6 0... 6 8 9... ±0. NAT0.0A 8 78 7 0 0000 0000 9 6 0... 0 0 9... ±0. NAT6.0A 8 79 7 0 0000 0000 9 6 0... 6 8 9... ±0. NAT.0A 8 80 7 0 0000 0000 9 6 0... 7 9... ±0. NAT0.0A 8 8 7 0 0000 0000 9 6 0... 0 0 9... ±0. NAT00.0A 8 8 7 0 0000 0000 9 6 0... 00 00 9... ±0. NAT0.0A 8 7 7 0 0000 0000 9 6 0... 0 70 9... ±0. NAT00.0A 8 8 7 0 0000 0000 9 6 0... 00 000 9... ±0. NAT600.0A 8 86 7 0 0000 0000 9 6 0... 600 00 9... ±0. NAT.V 8 7 7 0 0000 0000 7 6 0.... 7.... ±0. NAT.0V 8 76 7 0 0000 0000 7 6 0...... ±0. NAT6.0V 8 77 7 0 0000 0000 7 6 0... 6 8... ±0. NAT0.0V 8 78 7 0 0000 0000 7 6 0... 0 0... ±0. NAT6.0V 8 79 7 0 0000 0000 7 6 0... 6 8... ±0. NAT.0V 8 80 7 0 0000 0000 7 6 0... 7... ±0. NAT0.0V 8 8 7 0 0000 0000 7 6 0... 0 0... ±0. NAT00.0V 8 8 7 0 0000 0000 7 6 0... 00 00... ±0. NAT0.0V 8 7 7 0 0000 0000 7 6 0... 0 70... ±0. NAT00.0V 8 8 7 0 0000 0000 7 6 0... 00 000... ±0. NAT600.0V 8 86 7 0 0000 0000 7 6 0... 600 00... ±0. H70i page /6
NAT 8 Specifications Accuracy TEB typ. @ -... +8 C ±.7 % FS typ. Accuracy @ C typ. NLH @ C (BSL) typ. TC zero point and span typ. Long term stability year typ. ± 0. % FS typ. ± 0. % FS typ. ± 0.0 %.FS/K typ. < ± 0. % FS typ. Electrical Data Output / supply voltage... 0 ma: (9...) VDC 0... VDC: (9...) VDC... 6 VDC: (9...) VDC 0... 0 VDC: (...) VDC 0..... VDC ratiom., 0... 90% U supply : ± 0. VDC Rise time typ. ms/0...90 % nominal Switch-on-delay Inverse-polarity protection, short-circuit strenght @ C during min. 00 ms Environmental conditions Media temperature 0 C... + C Ambient temperature Protection ) Humidity...0 ma: to U S = VDC 0...0 VDC, 0... VDC,...6 VDC: to U S = 8 VDC 0... VDC ratiometric: to U S = VDC 0 C... + C (Cable PVC : - C... +60 C) (Cable PUR : -0 C... +70 C) IP6, IP67 Max. 9 % relative Vibration g RMS (0...000 Hz) g sin (80...000 Hz), oct./min, (x @ C) Shock 0 g / ms 00 g / 6 ms Male electrical plug Mx, EMC Protection Emission EN/IEC 6000-6- Immunity EN/IEC 6000-6- Mechanical Data Sensor / connection. (AISI60) Housing Sealing Male electrical plug Weight Mounting torque.0 (AISI0) FPM/EPDM/NBR see ordering information appr. 0 g Nm ) See Electrical connection Measuring accuracy Accuracy (%) 0 - - - - - -0-0 -0 0 0 0 0 0 0 60 70 80 90 max. typ. TEB (-... +8 C) Temp. ( C) H70i page /6
NAT 8 Dimensions 7. 7 9. Ø 8.8 8 0. Mx Ø 8.8 8.XX.XXXX.0.XX.XX 8.XX.XXXX..XX.XX 8 0. 7. Mx Ø8.8 Ø 8.8 8.XX.XXXX..XX.XX 8.XX.XXXX.//08.XX.XX G/" Seal DIN 869 SW9 Ø / NPT 7 6 SW9 Ø 7/6-0UNF SAE J.. 8.6 SW9 Ø 7/6-0UNF SAE (J96) 9 SW9 Ø 8.XX.XX7.XX.XX.XX 8.XX.XX0.XX.XX.XX 8.XX.XX.XX.XX.XX 9 9 0. 0 0 9.... 60 max. mm 6 7 M ~Ø0 SW9 Ø SW9 Ø SW9 Ø R/ R/8 M0x 8.XX.XX.XX.XX.XX 8.XX.XX9.XX.XX.XX 8.XX.XX6.XX.XX.XX 8.XX.XX.XX.XX.XX 8.XX.XXXX.XX.XX. 8.XX.XXXX.XX.XX. H70i page /6
NAT 8 Electrical connection Protection / electrical connection IP6 *) **) IP67 *) **) IP67 **) IP67 **) Industrial standard Contact distance 9. mm -pole Mx -pole Cable Cable 0 / 08 90 E white red Output signal 8.xx.xxxx.xx.9 9 96 E brown yellow white black green red green white <> <> brown yellow black green 8.xx.xxxx.xx./6/7/ * ) Provided female connector is mounted according to instructions ** ) Ventilation via male electric plug/cable end 00...0mA: min./max resistor vs. supply voltage @ Pmax = 00% Customer Load Resistor (Ohm) 000 800 600 00 00 0... Rmax Rmin 00 C Rmin C 0 0 0 0 Customer Supply Voltage (V)... Additional information Documents Data sheet www.trafag.com/h70 Instructions www.trafag.com/h70 Flyer www.trafag.com/h70666 H70i page 6/6