LC-5 Level Controller & Flow Monitor

Similar documents
LC-1 Level Controller & Flow Monitor

LC-3 Flow Monitor & Pump Run Verification

AP-7 Pump Station Controllers

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Operating Instructions. For. Level Control Module. Model SSR 1000

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

ALTERNATING RELAYS & CONTROLLERS ARM Series

PC-3000x PC-3000xC PUMP CONTROLLER. User Manual 844-4PRIMEX ( ) WATER SYSTEM INTEGRATOR AND CONTROLS PROVIDER

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

SX90 Process Controller

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SP6R-LSC CONTROLLER. User Manual. DUPLEX LIFT STATION CONTROL BAR GRAPH 4-20 ma INPUT AUTOMATIC ALTERNATION MOTOR STATUS LEDs

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Features and Benefits. Certifications

CDD4 Duct Carbon Dioxide Transmitter

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

Trident and Trident X2 Digital Process and Temperature Panel Meter

VLT 2800 DRIVE SPECIFICATIONS

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

FCU-MULTI Modbus Fan Coil Unit Controller

Pump Controls for Water and Wastewater. PUMP Vision. UNIVERSAL PUMP CONTROLLER, RTU, and DATA LOGGER

VersaMax Micro and Nano Technical Product Presentation

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

seal leak & temperature relays

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

CDD4 Series Room CO2 Transmitter Installation Instructions

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

LAUREL ELECTRONICS, INC.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Deaerator and Surge Tank Control

Pump Station Controller. Quick Start

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

WAT Industrial Drives

PGR-3200 MANUAL INSULATION MONITOR

CDD Carbon Dioxide Transmitter

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

GE Power Management. MMII Intelligent MCC Controller

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Basic User and Installation Manual

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Valve and Case Expansion Monitor Specifications

FC-DIN DIN-Rail Mount Fan Speed Controller

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Catalog Index Page Description C A Briggs Company -

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

current sensing relays

EXOcompact Third Generation Manual

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

02/11/2015

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

LAUREL ELECTRONICS, INC.

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Easy To Use OEMS Take Note

SOFT STARTERS PLANET -LOGIC

Intrinsically Safe Temperature Concentrator System

Safety Control Relay Product Catalog

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Vigil 3 Amplifiers. Installation Instructions

Digital Indicator Solutions

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

MC Series Drives. Flexible, simple, rugged, robust!

Comprehensive Modular Genset Controller

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

ACS Product Overview

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System

Intrinsically Safe Barriers

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

PowerFlex 40 Sample Specification

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Transcription:

The Level Controller and Flow Monitor provides a fully integrated Duplex Controller supporting both analog and discrete (float switch) level detection. The unit allows collecting 'rate of flow' information and the verification of the run time characteristics of the external pumps using external soft starters. The early detection of a failing pump allows a significant reduction in expensive emergency repairs and reduces the possibility of catastrophic system failures, reducing maintenance and overall operating costs. By monitoring the flow rate, the soft starter auxiliary contact and the pump seal and temperature inputs the unit ensures that the pump system is operating within specified bounds and allows the early detection of deteriorating pump performance. provides Analog level detection, Duplex pump control, pump health & run time verification, flow rate monitoring,a Bubbler controller and optional discrete (float switch) inputs. System parameters and run time statistics may be entered and viewed through the integrated HMI display or through a Modbus communications channel. In addition, the unit is supported by the LC_Config Windows based utility program for configuration, monitoring and data collection. An analog level sensor (0-10 Vdc or 4-20 ma) monitors the liquid level and provides 6 internal levels (Lockout, Off, Lead Start, Lag Start, High, Sensor Fault) for level discrimination. All inputs are provided with hysteresis and time sampling to minimize false readings caused by noise or liquid 'wave' action. Discrete (float switch) inputs may be connected as a backup to or as an alternative to the analog sensor. An integrated Bubbler controller has been designed to minimize air flow requirements and provides support for low cost analog level sensing. As a member of the Ingram Products LC family of level management products the is implemented utilizing a standard set of firmware and hardware building blocks. Features Flexible Analog level input (0-10 Vdc, 4-20 ma) Optional/Backup Discrete (float switch) inputs Handles +ve or -ve displacement Fully integrated Duplex Controller with flexible sequencing algorithm including Time of Day. Extensive Pump Health and Run Time verification. Automatic switch-over if lead pump fails Monitors inflow rate, min/max flow rate, individual pump flow rates and pump operating times Integrated Bubbler minimizes air requirements Small (126 mm X 90 mm) package Integral HMI display Modular design, compatible to entire LC Family of Level Management products Low power (12-24 Vdc, 100 ma) operation Network (Modbus) support Optional PC/Windows configuration & monitoring Data Sheet 1 10/12

Flow Monitor The includes an Analog Level Detector, a Duplex Pump Controller with Pump Health and Run Time Verification, Flow Rate monitoring and a Bubbler controller. In the simplest applications only the analog level detector and two pump outputs are required to provide Duplex pump control and Flow Rate Monitoring. The controller automatically selects the lead pump to operate when the level exceeds the user defined 'Lead Start' level and will switch on the 'lag' pump if the level exceeds the 'Lag Start' level. The Duplex Level Detection Duplex Pump Controller controller may be configured to alternate the two pumps between 'lead' and 'lag' roles. Pump temperature and seal leak signals allow the controller to monitor pump Health and automatically demote a pump to the 'lag only' operation the pump is not ready to operate. Flow Rate Monitor Sampling Control Pump Health Monitoring Run Time Verification is provided by monitoring an error signal provided by an external pump soft starter. This signal allows the controller to ensure that the pump is operating within specifications. Optional discrete level (float switch) inputs provide a backup to the analog level signal or may be used as the primary level detection mechanism. Bubbler Controller Pump Run Verification An integrated Bubbler controller supports both tanked and tankless bubbler systems with a sampling mechanism designed to minimize air flow requirements. HMI Display Modbus Flow rate monitoring measures the change in level over time to calculate the inflow and individual pump flow rates. The product family is built using standard hardware controllers that provide an integral HMI display and a Modbus communications option. The is provided in small (126 mm X 90 mm), DIN rail mounted controller. The integrated HMI provides access to run time statistics including flow and pump specific rates, averages, min/max values, pump operating times and pump failures. A Modbus communications port allows networking multiple LC products and supports PC based configuration, monitoring, simulation and project management. The Sensor signal may be 0-10 Vdc, or for 4-20 ma sensors a 500 ohm resistance may be connected in parallel. The Sensor input is scaled (converted to inches/feet/meters etc.) and then use to drive a 6 level discriminator. The discriminator outputs are then used to activate the required state of the internal Duplex controller. Power Sensor Health P1 Run L+ M I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 IA IB IC ID P1 Man Health P2 Run P2 Man Flow 35.25 O Level 18.35 O O Sts O O Sts O High Air Alarm Off Lead Start Lag Start Air High Reset + OK ESC Q0 Q1 -- Q2 Q3 Q4 Q5 Q6 Q7 Purge Data Sheet 2 10/12

The Pump Health inputs are connected to the pump temperature relay contact and the pump seal leak detector. The verification signals connect to the external starter contact, an optional external current sensor and an optional external phase error detector for each pump. The Manual input allows each pump to be manually started and the reset signal resets pump error conditions. The and outputs indicate if a system error or warning condition exists. The and signals are connected to external pump motor starter relays, the Air, Air and Purge outputs control the bubbler sub-system. Field Wiring Controller INPUT Description AI0 (I0) AI1 (I1) I2 I3 I4 AI5 (I5) I6 I7 I8 I9 IA IB IC Sensor Input (Analog) Seal measures seal resistance Temperature detects pump temperature contact closure Auxiliary contact detects motor starter failure and/or thermal overload tripping of motor starter Manual On forces on, provided level is above the 'lockout' level Seal measures seal resistance Temperature detects pump temperature contact closure Auxiliary contact detects motor starter failure and/or thermal overload tripping of motor starter Manual On forces on, provided level is above the 'lockout' level Off Level Lead Start Lag Start High Level ID Reset reset and error status Analog signals: 0 10 Vdc or 4-20 ma (500 ohm resistor in parallel) Digital signals: 0-24 Vdc (5 volt threshold), configurable as Normally Open or Normally Closed Controller INPUT Description Q0 Q1 Q2 Q3 Q4 Q5 Q6 system warning system error output active if level is? User defined high alarm activated when should be On. activated when should be On. /Flow /Select Q7 Purge Relay Outputs: 0-24 Vdc @ 10 Amps, 120/240 Vac @ 10 Amps (resistive), 2 Amps (inductive) Special Order: NPN or PNP outputs, 24 Vdc @ 2 Amps Power: 12-24 Vdc @ 100 ma. The LC product family is UL508a compliant when used with Class II power. Slave UL508a compliant relays should be used when switching voltages greater than 48 Vdc. Data Sheet 3 10/12

Duplex Control with Flow Rate Monitoring The LC Family Flow Rate monitoring subsystem uses the change in levels over time and the known tank dimensions to calculate pump flow rates and flow volumes. The controller uses the pump activation by the internal Duplex controller to determine flow activity. The Duplex control subsystem of the controller performs following actions: 1. The Lead pump will turn on when the level reaches the LEAD START level 2. The Lag pump will turn on when the level reaches the LAG START level 3. Both pumps will turn off when the level drops to the PUMP OFF level In the simplest applications the Analog level detector is connected to an external sensor and the two pump control outputs are connected to the motor starter for the two pumps. When the level rises above the Lead Start level one of the two pump output signals will be activated based on the current sequencing defined by the Duplex Pump controller configuration. The status outputs may be connected to panel status lights or other control functions. Analog Level Sensor While no pumps are active the measures the the time for the liquid to rise to the Lead Start level, providing the inflow rate. When a pump is activated the inflow rate is latched (and assumed to remain relatively constant) and the controller measures the time required for the pump to lower the level to the Off level, providing the pump flow rate. The pump flow volume is the difference between the level when the pump turns on and the level when it turns off plus the volume contributed by the ongoing inflow. If after activating the first (lead) pump the level continues to rise to the Lag Start level the second (lag) pump will be activated. The flow rate of the first pump is latched and the controller then measures the flow rate of the second pump, assuming that the inflow rate and first pump flow rate remains constant. Pump Health Monitoring The health of the pump is determined by the pump temperature contact and the pump seal leak contact. The temperature contact may be configured as either a normally open or normally closed contact. If active, it indicates that the pump is over-temperature and should not be operated. The seal leak contacts measure the drop in resistance if the pump seals fail, allowing liquid past the pump seals. The resistance of a good seal will be typically > 1 Mohm. A mild leak will reduce the resistance below 100 Kohm and a severe leak will reduce the resistance below 50 Kohm. The controller accepts the seal leak inputs directly and measures the seal leak contact resistance using a simple resistive divider or will accept dry contact inputs if an external seal leak relay must be used. The controller provides separate inputs for each pump's temperature and seal leak contacts and provides both a 'warning' level and 'error' (severe) level setting for the seal leak resistance. Data Sheet 4 10/12

Analog Level Sensor } Temp & Seal Leak contacts } Temp & Seal Leak contacts Pump Run Time Verification Run time verification ensures that when a pump output has been activated the pump operates within specifications. The Pump activation signal is connected to an external motor soft starter error contact. The soft starter monitors the pump motor for a range of faults such as current overload, locked rotor and phase in balance. If a fault occurs a fault output relay is activated to indicate to the that an error has occurred. The controller provides separate inputs for each pump's soft starter error contact. Analog Level Sensor } Temp & Seal Leak contacts Soft Start Fault Manual Start (HOA) } Temp & Seal Leak contacts Soft Start Fault Manual Start (HOA) Manual (HOA) Start The provides two separate inputs that allow manually starting a specific pump. The manual input is only active if the level is above the zero Lockout level. Discrete Level Inputs Four discrete level inputs are provided to allow fail safe operation if the primary analog level fails. These inputs are internally connected in parallel with the analog level discriminator outputs. If the analog sensor fails the discrete level inputs will force the lead (and/or lag) pump to operate. If no analog level monitoring is used the discrete inputs may be used as the primary level sensing mechanism with an external DPDT relay connected to a discrete Lockout level float switch if required. Data Sheet 5 10/12

Analog Level Sensor } Temp & Seal Leak contacts Soft Start Fault Manual Start (HOA) } Temp & Seal Leak contacts Soft Start Fault Manual Start (HOA) Pump OFF level LEAD ON level LAG ON level HIGH level Bubbler Controller The provides 3 outputs that support a Bubbler control sub-system. The Bubbler sub-system supports systems with one or two pumps, with or without an air reservoir tank. To minimize air usage the bubbler outputs activate the air flow only when a level sample is required. In 2 pump systems the pumps are alternated using a user defined duty cycle. A purge output signal may be used to activate a purge function if the bubbler pressure rises above a user defined setpoint. Analog Pressure Sensor } Temp & Seal Leak contacts LC-1 Soft Start Fault Manual Start (HOA) } Temp & Seal Leak contacts Soft Start Fault Bubbler Control Purge A/Select A/Flow Manual Start (HOA) Pump OFF level LEAD ON level LAG ON level HIGH level Data Sheet 6 10/12

Bubbler systems use the measured air pressure required to cause bubbles to flow through a depth of liquid to determine the depth of the liquid. They offer a low cost, intrinsically safe measurement technique, requiring only a low pressure air supply (typically ~ 12 psi), pressure regulator, check valve and a pressure transducer that provides a 0-10 Vdc or 4-20 ma signal proportional to the measured air pressure. Systems without an air reservoir (tankless) activate the air pumps when a level sample is required. Systems using an air reservoir tank (tanked) activate a pneumatic valve to allow air to flow from the tank when a level sample is required. The Apump 1/Flow signal enables the flow of bubbler air (tanked systems) or activates Air (tankless).the Apump 2/Select signal selects between Air and Air (tanked systems) or activates Air (tankless). The Purge output is activated when the air pressure exceeds a user defined threshold, indicating a blocked bubbler line. Reset A single input is provided that will reset all internal errors. Individual pump errors may be reset using the integrated HMI display. External Communications The may be configured, and operating statistics are accessible using the integrated HMI display. In addition, the unit may be configured and monitored across a standard Modbus/RTU network. To connect the unit to a Modbus network the APB-EXPMC Modbus adapter may be used. The APB-DUSB adapter provides a low cost, single point adapter allowing the unit to be connected to a PC/Windows computer for configuration and monitoring purposes. LC_Config The LC_Config application program operates on a Windows based PC and provides a graphic interface for configuring and monitoring the LC Family of controllers. The configuration utility includes a set of program management tools to streamline the configuration and commissioning of devices as well as providing run time monitoring of flow data and pump performance. The LC_Config program may communicate to an device using a Modbus RTU interface through the APB-EXPMC adapter or the APB-DUSB USB adapter. Data Sheet 7 10/12

Specifications Specification Controller Notes Power Size Environment EMC 24 Vdc, @ 100 ma 126 mm X 90 mm X 58.5 mm IEC68-2 IEC801-3 Inputs (digital) 24 Vdc (Off = 0-5, On = 10-24) & 2 Temperature, Aux Contact, Manual Start OFF, LEAD, LAG, HIGH levels Reset Inputs (analog) 0-10 Vdc, 50 kohm impedance Analog Level Detector & 2 Current monitoring Outputs Outputs (special order) Level Input Flow Run Verification Bubbler Relay 24 Vdc, 10 Amp, 240 Vac, 10 Amp resistive 240 Vac, 2 Amp inductive NPN (sink) 24 Vdc, 2 Amp PNP (source) 24 Vdc, 2 Amp 0-10 Vdc or 4-20 ma +ve/-ve displacement Gallons, Imperial Gallons, Meters Seconds, minutes, hours Auxiliary Contact closure Pump Current Pump Phase Relay contact Time filtering & Hysteresis Dual stage scaling 5 levels (Lockout, Off, On, Mid, High) Inches, feet or meters Status outputs require I/O expander. Min sample rate 0.5 sec, One or Two pumps with alternator/variable duty cycle Data Sheet 8 10/12