Cisco UCS B230 M2 Blade Server

Similar documents
Cisco UCS B230 M1 Blade Server

Cisco UCS B200 M2 Blade Server

Cisco UCS C460 M2 High-Performance Rack-Mount Server

Cisco UCS C460 M2 High-Performance Rack-Mount Server

Cisco UCS B230 M2 Blade Server

Cisco UCS B440 M1High-Performance Blade Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS B22 M3 Blade Server

Cisco UCS C260 M2 High-Performance Rack-Mount Server

Cisco UCS B200 M3 Blade Server

Cisco UCS E-Series Servers

Cisco UCS C24 M3 Server

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Cisco UCS C240 M3 Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS B420 M3 Blade Server

Cisco UCS C240 M3 Server

Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

Cisco UCS B200 M3 Blade Server

Cisco UCS B440 M2 Blade Server

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Cisco UCS C260 M2 High-Performance Rack-Mount Server

Cisco UCS E-Series Servers and Network Compute Engines

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco UCS B200 M4 Blade Server

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Cisco Secure Network Server

Cisco UCS B460 M4 Blade Server

Cisco Secure Network Server

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Cisco MCS 7825-I1 Unified CallManager Appliance

Cisco Content Delivery Engine 285 for Open Media Distribution

Acer AT110 F2 Specifications

Cisco MCS 7825-H3. Supported Cisco Applications

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco Content Delivery Engine 280 for TV Streaming

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

ThinkServer RD450 Platform Specifications

Cisco Nexus 7000 Switches Second-Generation Supervisor Modules Data Sheet

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Cisco MCS 7815-I2 Unified CallManager Appliance

Cisco StadiumVision Mobile Streamer

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

Cisco Nexus 9500 R-Series

Altos R320 F3 Specifications. Product overview. Product views. Internal view

CISCO MEDIA CONVERGENCE SERVER 7825-I1

The Cisco MCS 7835-H2 can run any of the following Cisco applications:

Cisco MCS 7815-I1 Unified CallManager Appliance

Cisco Connected Safety and Security UCS C220

Cisco UCS B22 M3 Blade Server

Cisco MCS 7816-H3 Unified Communications Manager Appliance

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Intel Xeon E v4, Optional Operating System, 8GB Memory, 2TB SAS H330 Hard Drive and a 3 Year Warranty

Cisco Nexus 9500 Series Switches

NEC Express5800/R120d-2M Configuration Guide

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v4 CPU)

Altos T310 F3 Specifications

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide

Cisco UCS C3160 Rack Server

CSU 0111 Compute Sled Unit

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v3 CPU)

SECURE 6. Secure64 Appliances Purpose-built DNS appliances for the most demanding environments DNS APPLIANCES DATA SHEET. Appliance Descriptions

Acer AR320 F1 specifications

CISCO MEDIA CONVERGENCE SERVER 7815-I1

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

GW2000h w/gw175h/q F1 specifications

Cisco Nexus 7000 Series Supervisor Module

SUN SERVER X2-4 SYSTEM

Cisco Network Convergence System 5500 Series

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

SUN SERVER X2-8 SYSTEM

Intel IP Network Server NSI2U

Features. MIC-7700Q: 3 x independent displays (third display output via optional cable) MIC-7700H: 2 x independent displays Controller

HUAWEI Tecal X6000 High-Density Server

Cisco Mobility Services Engine: An Open, Appliance-Based Platform for Delivering Mobility Services

Cisco 3300 Series Mobility Services Engine. Open, Appliance-Based Platform for Delivering Mobility Services

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

FWA-6280A User Manual 1. FWA-6280A User Manual

Acer AR320 F2 Specifications

Features. Q170: 3 x independent displays (third display output via optional cable) H110: 2 x independent displays Controller

Features. -40 ~ 60 95% humidity (non-condensing) 40 C (non-condensing) Vibration

Features. -40 ~ 60 95% humidity (non-condensing) 40 C (non-condensing) Vibration

Cisco Nexus 7000 Switches Supervisor Module

SCHOOL OF PHYSICAL, CHEMICAL AND APPLIED SCIENCES

Installing the IPS 4345 and IPS 4360

Features. With SSD: 3 5 ~ 500 Hz, random, 1 hr/axis With 2.5" HDD: 1 5 ~ 500 Hz, random, 1 hr/axis

QuickSpecs. HP Z600 Workstation Overview

SUN SERVER X3-2 SYSTEM

Milestone Definition Date. The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public.

Acer AT310 F2 Specifications

QuickSpecs. HPE Cloudline CL7100 Server. Overview

Cisco HyperFlex HX220c M4 Node

High Performance Computing

Transcription:

SpecSheet Cisco UCS B230 M2 Blade Server Overview The Cisco UCS B230 M2 Blade Server is a two-socket, half-width blade server that extends the capabilities of the Cisco Unified Computing System, using Intel s Xeon E7-2800 Series multi-core processors with 32 DIMM slots, one mezzanine slot and up to two solid-state drives (SSD). Up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis. Figure 1. Cisco UCS B230 M2 Blade Server 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 17

Detailed Views Figure 2. Front View of the Cisco UCS B230 M2 Blade Server 1 SSD activity LED 9 Locator button and LED 2 SSD1 fault LED 10 Network link status LED 3 SSD sled in Bay 1 11 Blade health LED 4 SSD 2 activity LED 12 Reset button 5 SSD 2 fault LED 13 Power on/standby button and LED 6 Blade release lever captive screw 14 Local console connector 7 Blade release lever 15 Asset tag 8 SSD sled in bay 2 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 2 of 17

Figure 3. Local console connector cable for the Cisco UCS B230 M2 Server 1 Connector to blade server slot 3 VGA Connection for a monitor 2 DB9 Serial connector 4 2-port USB connector for a mouse and keyboard 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 3 of 17

Figure 4. Inside the Cisco UCS B230 M2 Blade Server 1 DIMM slots 2 CPU 1 and heat sink 3 CPU2 and heat sink 4 DIMM slots 5 Adapter card connector 6 Diagnostic button 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 17

Base Unit Features Table 1. Feature Specifications for the Cisco UCS B230 M2 Blade Server Feature CPU Chipset Memory Mezzanine slots Internal storage devices Interfaces Power subsystem Fans Integrated management processor Specifications Up to two Intel Xeon E7-2800 Series processors Intel 7510 chipset 32 DIMM slots (up to 512 GB) One Mezzanine slot Up to two hot-swappable solid-state drives (SSD) A console port is provided to give a direct connection to a blade server to allow operating system installation and other management tasks to be done directly rather than remotely. The port uses a local console cable dongle device included in the chassis accessory kit. The local console connector cable (N20-BKVM) provides a connection into a Cisco UCS blade server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. Integrated in Cisco UCS 5100 Series Chassis Integrated in Cisco UCS 5100 Series Chassis Cisco Integrated Management Controller (CIMC) interface to the Cisco UCS Manager 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 17

Configuring the Cisco UCS B230 M2 Server UCS B230 M2 base server (must be selected) B230-BASE-M2UPG STEP 1: Select the CPU type Select one or two CPUs from the following list: 2.4 GHz Xeon E7-2870 130W 10C CPU/30MB cache 2.26 GHz Xeon E7-2860 130W 10C CPU/24MB cache 2.0 GHz Xeon E7-2850 130W 10C CPU/24MB cache 2.13 GHz Xeon E7-2830 105W 8C CPU/24MB cache 1.73 GHz Xeon E7-2803 105W 6C CPU/18MB cache UCS-CPU-E72870 UCS-CPU-E72860 UCS-CPU-E72850 UCS-CPU-E72830 UCS-CPU-E72803 2.13 GHz Xeon E7-8867L 105W 10C CPU/30MB cache UCS-CPU-E78867L STEP 2: Select the memory type Please refer to the Memory Notes section for allowable memory configurations and rules/guidelines. Select a minimum of one and a maximum of 16 DIMM kits from the following list: 8GB DDR3-1333MHz RDIMM/PC3-10600/2x4GB Kit/Low Volt 16GB DDR3-1333MHz RDIMM/PC3-10600/2x8GB Kit/Low Volt A02-M308GB3-2 A02-M316GB3-2 32GB DDR3-1066MHz RDIMM/PC3-8500/4R/2x16GB Kit/Low Volt A02-M332GD3-2-L Note: Memory must be populated in identical DIMM pairs 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 17

STEP 3: Select the 7mm SSD drive type (optional) The SSD drive is not required. You can select a maximum of two drives: 32GB Low Height 7mm SATA SSD hot plug/drive sled mounted 64GB Low Height 7mm SATA SSD hot plug/drive sled mounted N20-D032SSD N20-D064SSD STEP 4: Select a mezzanine card A mezzanine card is required. Select one from the following list: UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AC0002 Cisco UCS NIC M51KR-B Broadcom BCM57711 Network Adapter N20-AB0002 Cisco UCS CNA M61KR-I Intel Converged Network Adapter N20-AI0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 N20-AQ0102 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 17

STEP 5: Select the operating system. (optional) A variety of operating system options are available. SUSE Linux Enterprise Server SLES/1yr subscription/svcs required/0 media SLES/3yr subscription/svcs required/0 media SLES-1A SLES-3A Red Hat Enterprise Linux RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL/4 Socket/1 Guest/1Yr Svcs Required RHEL/4 Socket/1 Guest/3Yr Svcs Required RHEL/4 Socket/4 Guest/1Yr Svcs Required RHEL/4 Socket/4 Guest/3Yr Svcs Required RHEL/4 Socket/U Guest/1Yr Svcs Required RHEL/4 Socket/U Guest/3Yr Svcs Required RHEL Add-Ons High-Availability/2 Socket/1Yr Svcs Required High-Availability/2 Socket/3Yr Svcs Required High-Availability/4 Socket/1Yr Svcs Required High-Availability/4 Socket/3Yr Svcs Required Resilient Storage With Ha/2 Socket/1 Yr Svcs Required Resilient Storage With Ha/2 Socket/3 Yr Svcs Required Resilient Storage With Ha/4 Socket/1 Yr Svcs Required Resilient Storage With Ha/4 Socket/3 Yr Svcs Required RHEL-2S-1G-1A RHEL-2S-1G-3A RHEL-2S-4G-1A RHEL-2S-4G-3A RHEL-2S-UG-1A RHEL-2S-UG-3A RHEL-4S-1G-1A RHEL-4S-1G-3A RHEL-4S-4G-1A RHEL-4S-4G-3A RHEL-4S-UG-1A RHEL-4S-UG-3A RHEL-HA-2S-1A RHEL-HA-2S-3A RHEL-HA-4S-1A RHEL-HA-4S-3A RHEL-RS-2S-1A RHEL-RS-2S-3A RHEL-RS-4S-1A RHEL-RS-4S-3A 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 17

Scalable File System/2 Socket/1 Yr Svcs Required Scalable File System/2 Socket/3 Yr Svcs Required Scalable File System/4 Socket/1 Yr Svcs Required Scalable File System/4 Socket/3 Yr Svcs Required RHEL-SFS-2S-1A RHEL-SFS-2S-3A RHEL-SFS-4S-1A RHEL-SFS-4S-3A Windows Server Windows Svr 2008 ST media (1-4CPU, 5CAL) Windows Svr 2008 EN media (1-8CPU, 25CAL) Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) MSWS-08-STHV MSWS-08-ENHV MSWS-08R2-STHV MSWS-08R2-ENHV Windows Svr 2008 R2-2 CPU-Data Center Windows Svr 2008 R2-4 CPU-Data Center MSWS-08R2-DCHV2S MSWS-08R2-DCHV4S VMware Server VMware vsphere Advanced (1 CPU), 1yr 24x7 support VMware vsphere Advanced (1 CPU), 3yr 24x7 support VMW-VS-ADV-1A VMW-VS-ADV-3A VMware vsphere Enterprise (1 CPU), 1yr 24x7 support VMware vsphere Enterprise (1 CPU), 3yr 24x7 support VMware vsphere Enterprise Plus (1 CPU), 1yr 24x7 support VMware vsphere Enterprise Plus (1 CPU), 3yr 24x7 support VMW-VS-ENT-1A VMW-VS-ENT-3A VMW-VS-ENTP-1A VMW-VS-ENTP-3A Select an OS Media Kit. (optional) RHEL 6 Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 ST media Windows Svr 2008 EN media Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) Windows Svr 2008 ST media R2 DC (1-8CPU, 25CAL) RHEL-6 SLES-11 MSWS-08-STHV-RM MSWS-08-ENHV-RM MSWS-08R2-STHV-RM MSWS-08R2-ENHV-RM MSWS-08R2-DCHV-RM 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 17

STEP 6: Select from a variety of value-added software. (optional) BMC BladeLogic CM for Virtualized Cisco Servers BMC Blade Logic Compliance, VM Bundle, 2 Socket Server BMC BladeLogic CM for Physical Cisco Servers BMC Blade Logic Compliance, Single OS BMC Bladelogic CM, Virtualized 4-Socket Server BMC Blade Logic Compliance, VM Bundle, 4 Socket Server BMC BPPM Per Server BMC-001 BMC-001-COMP BMC-002 BMC-002-COMP BMC-003 BMC-003-COMP BMC-012 VMware vcenter Server Standard, 1yr 24x7 support VMware vcenter Server Standard, 3yr 24x7 support Nexus 1000V License PAK for 1 Virtual Ethernet module Nexus 1000V VSM Virtual Appliance Software VMW-VCS-1A VMW-VCS-3A N1K-VLEM-UCS-1 N1K-CSK9-UCS-404 STEP 7: Select the appropriate Services. (optional) A variety of Service options are available, as listed here. Unified Computing Mission Critical Service This service delivers personalized technical account management, expedited technical support, and expert field support engineering for the Cisco Unified Computing System (UCS). The Mission Critical Support Service provides a designated technical account manager (TAM) who acts as a strategic resource to help assure the unified computing environment runs at peak efficiency. Should a problem arise that threatens business continuity, the TAM provides crisis management leadership, and customer IT staff gets expedited access to Cisco s award-winning Technical Assistance Center (TAC). Please note: This service has qualification criteria. There should be $1.2M of UCS equipment, 200 blades and a single location to qualify for this service level. UC Mission Critical 24x7x4 On-site UC Mission Critical 24x7x2 On-site CON-UCM7-B230M2U CON-UCM8-B230M2U 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 17

Unified Computing Support Service For support of the entire Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Provided is the access to the award-winning Cisco Technical Assistance Center (TAC) around the clock, from anywhere in the world. For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include the Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. UC Support 8X5XNBD Not on-site UC Support 8X5X4 Not on-site UC Support 24x7x4 Not on-site UC Support 24x7x2 Not on-site CON-UCS1-B230M2U CON-UCS2-B230M2U CON-UCS3-B230M2U CON-UCS4-B230M2U UC Support 8X5XNBD On-site UC Support 8X5X4 On-site UC Support 24x7x4 On-site UC Support 24x7x2 On-site CON-UCS5-B230M2U CON-UCS6-B230M2U CON-UCS7-B230M2U CON-UCS8-B230M2U 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 11 of 17

Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. Customers can choose from several levels of advanced parts replacement coverage, including onsite parts replacement in as little as two hours. Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. UC Warranty Plus 24x7x4 UC Warranty Plus 8X5XNBD On- Site CON-UCW3-B230M2U CON-UCW5-B230M2U For more information, see Unified Computing Warranty and Support Services. For a complete listing of available Services for Cisco Unified Computing System: Unified Computing Services. 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 12 of 17

Product Notes Memory notes, allowable configurations, and rules/guidelines Table 2. DIMM Installation Order DIMM Population Rules Install only in matched pairs. Memory for this server is sold in pairs that are matched in size, speed, manufacturer, and other parameters, and mixing DIMMs that are not matched can cause the memory to not be recognized by the system. Preferred DIMM Population Order DIMM per CPU Install in Slots 2 (blue) (B0, B1) Make sure the latches are fully seated into the DIMM. 4 (blue) (B0, B1) - (D0, D1) This blade server needs at least one matched pair of DIMMs attached to CPU 1 or CPU 2. Both CPUs can boot and run from a single DIMM pair. 8 (blue, white) (B0, B1) - (D0, D1) - (A0, A1) - (C0, C1) DIMMs installed in slots for an absent CPU are not recognized. For optimal performance, distribute DIMMs evenly across both CPUs. 16 (blue, white yellow, black) (B0, B1) - (D0, D1) - (A0, A1) - (C0, C1) (B2, B3) - (D2, D3) - (A2, A3) - (C2, C3) The UCS B230 contains 32 memory DIMM slots. Each CPU has 16 DIMM slots organized in pairs. The B230 M2 blade server needs at least one matched pair of DIMMs attached to CPU 1 or CPU 2. Both CPUs can boot and run from a single DIMM pair. The DIMM pairs must be identical (the same size, speed, and manufacturer) and are sold in appropriately matched pairs, but one DIMM pair on a CPU can be different from other pairs. The DIMMs installed in slots for an absent CPU are not recognized. Memory DIMM s should be installed evenly across the installed CPUs, though it is not a requirement. Memory Arrangement DIMM slots are color-coded blue, white, yellow, and black, and it is recommended that the memory be installed memory in that order. Figure 5 shows how the DIMMs slots are laid out on the blade server motherboard. A CPU uses the DIMM slots directly to the right or the left of the CPU. Note that the arrangement for CPU 2 and CPU 1 is not identical. 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 13 of 17

Figure 5. DIMM Slot Numbering Each channel pair is identified by a letter: A, B, C, or D for each CPU. Each DIMM pair member is identified by numbers, 0, 1, 2 or 3. Additional DIMMs must be installed as shown in Table 2. 1 The slots inside the brackets are electrically paired with each other, and should be populated with identical matched DIMMs that were ordered as a pair. Do not swap a paired DIMM with a DIMM that is not identical in manufacturer part number. 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 14 of 17

Table 3. QA Tested DIMM Configurations QA Tested Configurations Total Mem (1 CPU) 1 CPU 2 CPU Total Mem (2 CPU) 8GB 2 x 4GB 2 x 4GB 16GB 32GB 4 x 8GB 4 x 8GB 64GB 64GB 8 x 6GB 8 x 6GB 128GB 96GB (8 x 8GB) + (8 x 4GB) (8 x 8GB) + (8 x 4GB) 192GB 128GB 16 x 8GB 16 x 8GB 256GB 128GB 8 x 16GB 8 x 16GB 256GB 192GB (8 x 16GB) + (8 x 8GB) (8 x 16GB) + (8 x 8GB) 384GB 256GB 16 x 16GB 16 x 16GB 512GB RAID Controller Notes The LSI-2008 is an eight port, 6Gb/s SAS/SATA RAID On-a-Chip (ROC) VLSI IC. The LSI-2008 ROC provides and x8 PCIe Gen2 I/F, it will be connected as x4 on the Marin base card. The LSI LSI 2008 SAS/SATA Controller is embedded on the motherboard and supports the following features Supports Raid 0, 1 LSI-2008 Flash ROM The LSI-2008 requires a minimum of 8Mbyte Flash ROM configured for 8-bit I/O. The Flash ROM contains code for the System Optional BIOS, which is needed for booting the RAID array, and also RAID firmware for the embedded CPU. 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 15 of 17

Technical Specifications Physical Dimensions Specifications Table 4. Physical Dimension Specifications for the Cisco UCS B230 M2 Blade Server Specification Height Width Value 1.95 inches (50 mm) 8.00 inches (203 mm) Depth 24.4 inches (620 mm) Weight 18.0 lbs (8.16 kg) * *Note: The system weight listed here is an estimate for a fully configured system and will vary depending on number of peripheral devices. Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: http://www.cisco.com/assets/cdc_content_elements/flash/datacenter/cisco_ucs_power_calculator/. 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 16 of 17

Environmental Specifications Table 5. Environmental Specifications for B230 M2 base server Environment Specification Temperature operating Temperature nonoperating Altitude: Operating Altitude: Non operating Humidity 50 to 95 F (10 to 35 C) -40 to 149 F (-40 to 65 C) 0 to 10,000 ft (0 to 3000m); maximum ambient temperature decreases by 1 C per 300m 40,000 ft (12,000m) 5-93% non condensing Safety UL 60950-1 CAN/CSA-C22.2 No. 60950-1 EN 60950-1 IEC 60950-1 AS/NZS 60950-1 GB4943 EMC: Emissions EMC: Immunity 47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR2 2 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EN50082-1 EN61000-6-1 EN55024 CISPR24 EN300386 KN 61000-4 Series For More Information Please visit http://www.cisco.com/go/ucs. Printed in USA C17-665957-01 06/11 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 17 of 17