Dual 10A RC Relay MK2

Similar documents
Engine Sound Simulator

Cheap Control Systems. Cheap Six Channel (C6C) Servo Controller Version 2.3 OVERVIEW

Cheap Control Systems. Cheap Twelve Channel (C12C) Servo Controller Version 1.0 OVERVIEW

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Electronics Workshop. Jessie Liu

MK2 ENGINE SOUND SIMULATOR Instructions for: # COMBO

TPG-5. User Instructions. Tone Generator. Tone Pulse Generator

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

9000 SERIES - CONTACTLESS JOYSTICKS ULTRA LOW PROFILE ONE, TWO, THREE AXIS WIDE VARIETY OF HANDLES

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

9000 SERIES - CONTACTLESS JOYSTICKS ULTRA LOW PROFILE ONE, TWO, THREE AXIS WIDE VARIETY OF HANDLES

What are output transducers An output transducer will convert electrical signals passed to it by the process into another form of energy.

Rexroth Controller Installation & Operations Manual

MartMod Mk5. Thank you for choosing what we believe is the best voice modulator and dalek electronics system that you can buy.

Digital Camera Controller

THE CTB08D LIGHT CONTOLLER

VEX ARM Cortex -based Microcontroller and VEXnet Joystick User Guide

Rover 5. Explorer kit

SRI-02 Speech Recognition Interface

BEST Control System. Dave Wilkerson. September 12, 2015

ACTION ELECTRONICS. P110 Operating Instructions

Project Planning. Module 4: Practice Exercises. Academic Services Unit PREPARED BY. August 2012

Installation- and Operation Instruction for the Remote Control System HM22XX

II. Programming and Adjustments

"Executive" PCU for Scanreco G4 systems SERVICE MANUAL

LS M100 Frequency Inverter Easy Start Guide

EnerSure Installation Guide

PLUS+1 GUIDE Software. JS6000 PWM Service Tool User Manual

The Universal Translator

DEFAULT SCREEN. Button and Screen Layout DRILLING WIDTH TARGET RATE HOPPER NUMBER CROP NAME DRILLING ACTION CROP NUMBER. HOPPER selection POWER On/Off

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

If I wanted to connect an LED and little light bulb and have them switch on and off with one switch, my schematic would look like the one below.

Device: LDP This document Version: 1.0. Date: July Description: 80x08 1R1G LED Display Panel

Canon EOS Rebel T2i Top Cover Replacement

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Profiler IV Feed Back Version DC Motor Control Board with Current Profiling Capability Variable travel length version

Robocolor II System. users guide

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Elapsed Timer Control Panel

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Programmable Control. Name Class Teacher. Ellon Academy Technical Faculty

Magnetic and Hydraulic-Magnetic Circuit Breaker

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Multifunction Expansion Board. Installation and Operation Manual

Analog Advise Devar, Inc Essential Guide to Setting Up the 3019 and 3020 Controller

Installing Sentor. Hardware Installation

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit

Wireless Key fob, Key pad & Receiver Range

Blue Point Engineering

Blue Point Engineering

ADDENDUM FOR 20, 27, & 28 OPTIONS

M4-ATX-HV 6-34V Intelligent ATX Power Supply

Digital Clamp-on Meter Instruction Manual

Omni + User Manual. Dual Setpoint Temperature Controller with Programmable Input & TIMER. Omni 96+ Omni 72+ Omni 48+ TMR TMR TMR

Electric Vehicle Television. EVTV Motor Verks. Presents JLD404AH Intelligent Ampere Hour Meter OPERATION MANUAL. Copyright 2012 EVTV LLC.

Stand-alone Proximity Access Control

DC3IOB Revision User Guide Updated 3/29/10. Overview

Allen-Bradley Drives

AX1500. Dual Channel Digital Motor Controller. Quick Start Manual. v1.9b, June 1, 2007

Instruction Manual CTC-1

How-To #3: Make and Use a Motor Controller Shield

Isolation Verification Control Mining - Marine - Transit Solutions LIVE Distributed By Locksafe Industrial Safety Equipment

Part 2: Building the Controller Board

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

The Control System. Student Interface Batteries Contest Plan Calibration Presentation. The Control Box

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

SMART SHOT CONTROLLER FLUID USERS GUIDE

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

DOLXFD1000B. Waterproof Access Control/Reader

CORTEX Microcontroller and Joystick User Guide

Blueprint Drawings & Wiring Diagrams. for branch circuits

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Mounting DIGITAL DISPLAY

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Web Site: Forums: forums.parallax.com Sales: Technical:

Korean language is available. Choose "Korean" from Language select buttons in the Information screen.

This is an inspection failure, not meeting the requirement of >10k Ohm between either PD battery post and chassis.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Branch PLC. Velocio s Branch PLC

Written By: John Sutton

Instruction Manual for BE-SP3 Circuit. 10/21/07

Digital Keypad Introduction

Thomas. Change Machine. Operator Guide

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

Keypad Lock. Operation and Service Manual. Order parts online

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

The mystem Project Board Quick Start

How to assemble and disassemble Anafi

Super E-Line Applications in Automotive Electronics Replacement of Large Packaged Transistors with an Enhanced TO92 Product David Bradbury

Parts and Accessories Installation Instructions

MOD MyFord Touch Installation Manual Full plug and play programming and power kit, for Ford Vehicles with 8" MyFord Touch Displays

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

FLIER. ESC for Boat 2S to 22S. User s Manual FLIER

USB PowerControl 0042-USBPC-DSBT / USBPCNE-DSBT

Innovation First, Inc Full-Size Robot Controller Reference Guide

Energy Management System. Operation and Installation Manual

Transcription:

Dual 10A RC Relay MK2 Stockist:- Scale Warship 5 Beechwood Avenue New Milton Hants BH25 5NB 07855 941117 john@scalewarship.com 1

INTRODUCTION This unit allows the signal from a standard radio control receiver to independently activate a pair of relays, each capable of switching up to 10amps at 30volts for the control of lamps, motors, bilge pumps, solenoids, sound effects etc. This is an alternative method to that often used of fitting a servo with a cam to operate a microswitch at some point on its travel. A further benefit is that this unit's software allows the user to optionally configure the switching action to be latching or non-latching (momentary). Latching action is mainly used for circuits intended to stay ON the majority of the time (lights, smoke generators etc) whereas non-latching is mainly used for circuits that will only be switched ON briefly (sound effects, bow thrusters etc) As this is a dual switch unit, it is really intended for use with a (spare) proportional channel of the receiver to allow the user to operate the relays independently i.e. moving the transmitter joystick in either direction from centre operates the appropriate relay. If used on a switched digital channel of the receiver, both relays operate simultaneously and in opposition (ie one ON and the other OFF, then vice versa). This is not recommended. A dual switch unit, like this one, can be wired up to give simple forward/reverse/stop control of a motor be it a robot buggy or a bow-thruster in a model boat. A wiring diagram for this application is included elsewhere in this guide. SPECIFICATION Receiver voltage range: 4.4v to 6v Receiver Channel: A single proportional channel allows independent operation of each relay (1.5mSec neutral assumed). Relay Contacts: Two single pole change-over relays rated 10amp, 30volt. Operating Modes: Each switching channel may be configured for latching or non-latching operation by its jumper link Loss of / Invalid Signal: Both relays turn OFF and twenty consecutive 'good' pulses (less than 0.5 sec in total) must be received before normal operation resumes Switch-on Delay: At power-up, both relays are held in the OFF state for a period of 4 seconds. This is to allow time for RC receivers (particularly 2.4GHz types) to stabilise/lock-in to prevent inadvertent operation of the attached loads at power up RELAY INFORMATION Each relay has a single pole changeover (SPCO) set of contacts. These are completely isolated from the receiver circuit and may be wired up in exactly the manner that an ordinary switch would be. 2

The legends on the unit lid identify the screw terminal blocks associated with the two sets of relay contacts. Wiring is inserted through the slot in the case sides and the clamping screws are tightened via the slot in the case lid. The relay contacts are labelled as NC (normally closed), COM (common) and NO (normally open). When a relay is OFF, the COM contact is connected to the NC contact. When a relay is ON, the COM contact is connected to the NO contact the latter are the pair of contacts most frequently used to simulate an ordinary switch. The switched loads may be wired as desired using the main battery in the system or indeed other batteries of different voltage(s) to suit the load(s). Conventionally, loads are connected to ground (0v) and their 'hot' side is connected to the appropriate power source via the relay contacts. OPERATION Trip Points The trip points (for operation of the switches) are set to be at about 40% of the joystick's travel (from centre) such that adjusting the other channel sharing the same joystick is unlikely to cause unintended operation of the switches. The span and offset on individual transmitters may serve to vary the trip points a little. An amount of hysteresis or 'dead-band' has been applied to the trip points. This prevents relay chatter if the stick is held at the trip point and receiver noise varies the pulse width slightly so for example in the non-latching mode of operation the relay turns ON at about 40% of stick travel (from centre) but doesn't turn OFF until below about 20% of stick travel. Latching Mode Moving the joystick to the trip point turns the relay ON. The joystick can then be returned below the trip point (usually to centre) and the relay remains ON. Now moving the joystick back in the same direction past the trip point causes the relay to turn OFF. Non-Latching Mode This is also referred to as 'momentary' operation. Moving the joystick to the trip point turns the relay ON but it only remains ON until the joystick is released back to its central position. i.e the relay only operates whilst the joystick is held away from its centre position. Mode Selection Each relay may be set for LATCHING or NON-LATCHING operation by moving the jumper link adjacent to that relay into the position marked L or N/L on the printed circuit board. In the image right, the jumpers are shown setting both relays to NON- LATCHING operation. The jumpers are continuously monitored so any changes made are immediately acted upon. 3

To gain access to the jumper links, the lid of the unit requires to be opened by removing the 4 screws. When replacing the lid, take care not to over-tighten the screws lest you strip the threads in the plastic case. Though it anticipated that the mode of each switch will be set prior to installation, it is not necessary to remove power from the unit to adjust the mode(s) when required - the link positions are read immediately they are changed and the relays behave accordingly. WIRING Receiver - the unit is supplied with a short male/male Futaba lead to connect it to the receiver. The lead plugs into the unit as shown ie with the white wire closest to the edge of the unit. The remaining end is plugged into the chosen channel of the receiver. The unit takes its power, including driving the relays, from the receiver s 5v supply. The assignment of the colours to functions of this cable is as follows:- white = signal red = receiver +ve (5v) black = receiver -ve (0v) Loads - the diagram below shows an example of how two loads requiring different voltages can be wired to the unit. 4

The following diagram illustrates how the unit may be connected up to give simple bidirectional control of a motor, including stop. Both switches should be configured in nonlatching (momentary) mode for this application. TESTING AND SETTING UP Before testing the unit, the latching / non-latching mode jumpers should be set to the desired state for each channel. As supplied the factory default setting is non-latching. Initially, connect the unit to the receiver alone. Switch on the transmitter first, then power the receiver. Allow at least four seconds (switch-on delay period) for the unit to become active before operating the receiver. Then move the joystick of the chosen channel and see if the relays operate in the expected positions described earlier. The relays will be heard to gently click when they pull in and drop out. This click may be easier to hear if the unit is firmly pressed onto a table or work surface which serves to amplify the sound. Now the unit may be wired to the chosen loads in the chosen configuration and the function test repeated. NOTES If controlling motors in the forward/reverse/stop configuration, it should be noted that in the stop position the relay contacts short the motor terminals together. Thus with a motor running at high speed and especially if it is driving a high inertia load, shorting its terminals will cause it to stop extremely quickly (the so-called 'suicide' braking method) which could cause mechanical damage to the motor, its gearbox and/or load quite apart from causing very high currents to flow from the motor through the relay contacts, again possibly damaging or reducing the life of either or both. In the same way, instantaneous reversing gives both the motor and the relay contacts a hard time. 5

In practice this is only an issue with heavy vehicles with excellent traction, which are more likely to be controlled by an ESC rather than this unit. In proving tests of the prototype unit both the relays and a selection of various motors/motor-gearboxes survived thousands of start/stops followed by further thousands of reversals. Typically in marine applications water flow over a (suddenly) stopped propeller doesn't cause back-driving of the motor and the high currents associated with shorted dynamo action. If the motor is wired up for unidirectional control through a single set of NO (normally open) contacts, then none of the foregoing applies. 6