QC-7600A. Instruction Manual. Anztec, P.O. Box 3288, Christchurch, New Zealand Phone ,

Similar documents
QW-5956B Credit Card Enabled Wash Entry System With Contactless Payment

QW-5953 Credit Card Ready Wash Entry System

Table of Contents. Unpacking and Inspection Setup Loading the Media Mount the Printer on the Wall... 16

Money Order Terminal User Guide for VeriFone Vx570

California Antique Slots, Inc. (805) (FAX)

cb 1500 quick start guide & user manual Time and Attendance Made Simple...

Thomas. Change Machine. Operator Guide

Money Order Training Guide for VeriFone Vx570

TotalPass P600 QUICK GUIDE

TOTALPASS SMALL BUSINESS PREMIUM PROXIMITY QUICK START GUIDE PLEASE READ THIS FIRST

NKL CX Series. Customer Manual. Version /23/2012 P/N

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual

Validator Update Instructions for Rowe BC1200 $1 - $20

A m e r i c a n C h a n g e r OPERATIONS MANUAL MODEL AC2207. ARL Listed STD: UL 756

Installation & Setup Guide

Setting up NCR Silver for ios. This guide will walk you through the initial set up of NCR Silver ios.

CR35(B) CASH REGISTER QUICK START MANUAL

UNIVERSAL MOUNT USER GUIDE

ES1624 MFP Setup and Installation Guide

TT230SM THERMAL TRANSFER PRINTER USER S MANUAL

MODEL 633 B3 FREE PLAY 500. Manual and set up Procedures

INVISION TM IRIS TIME CLOCK USER GUIDE. InVision Iris Time Clock

A m e r i c a n C h a n g e r

TOTALPASS SMALL BUSINESS PREMIUM PROXIMITY QUICK START GUIDE PLEASE READ THIS FIRST

MODEL 686 B3 MERLIN 500. Manual and set up Procedures

e-motion Software Module

TOTALPASS SMALL BUSINESS PREMIUM BIOMETRIC QUICK START GUIDE PLEASE READ THIS FIRST

Troubleshooting CHAPTER

MONARCH 9416 XL QUICK REFERENCE

Alexandria Network Printer

Card Reader User Guide

XEA217 Frequently asked questions.

2200 Series POS System

XEA207 Frequently asked questions.

ict250 Countertop Quick Setup Guide Semi Integrated Payment Application (SIPA) for Retail and Quick Service Solution ict250-sipa-qsg

Quick Start Guide Ioline StudioJet

Albert. User Guide. Version 6.0 September Albert User Guide Commonwealth Bank 1

Replacing the Billboard Router

VX 820 Duet Series APACS 40 User Guide

XE-A212 Frequently Asked Questions

XEA213Frequently asked questions.

Toshiba Tec ST-Axx Series Installation Guide

Holland Computers, Inc. Crane Kit Manual Part Number RA-CRANE-KIT

emedny POS Start Guide

SMART Coin System QUICK START AND CONFIGURATION GUIDE

InfraStruXure Central Standard/Enterprise Installation/Start-Up Service Procedure

User Guide. Accept EFTPOS, Visa and Mastercard payments on the go with Kiwibank QuickPay.

Triton ATM Configuration

User Guide. Accept EFTPOS, Visa and Mastercard payments on the go with Kiwibank QuickPay.

4 & 8 CHANNEL ~ 4/8 POE ~ 1080P NVR ORPHEUS-NVR-8 QUICK SETUP GUIDE V Copyright Qvis. All documentation rights reserved.

V X 680 Series APACS 40 User Guide

Operation Manual SuperDry Data Logger (SDDL)

VTC. 200/300 Series. VTC elock controller. VTC elock Instructions. Network VTC elock has three components:

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

mpos Merchant User Guide

5170 POS System. Installation and Maintenance Guide

Introduction Box items and guidelines... 2 Maintenance. 2 Charging... 2 Warning. 2. Guidelines... 3 Unpacking... 3

Ioline 300/350HF System

Congratulations on the purchase of your new Clover Mini

Reference Guide for the KODAK Picture Kiosk GS Compact. Software Version 2.0

POS BACK OFFICE GENERAL SETTINGS. a project guide to rezku POS. Access General Settings General Settings Restaurant Settings Available Order Types

CR6X CASH REGISTER QUICK START MANUAL

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Indoor Mini Dome. Hardware Manual D91, D92, E91, E92. Ver. 2013/06/14

POS User Guide VX5xx

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

VX 675 Series APACS 40 User Guide

Dell Edge Gateway. Service Manual Series

9-pin dot matrix printer

CF3000 Dealer Diagnostic Tool Instruction Manual

Money Machine 2 Self-Service Coin Counter Bag Models. User Guide

To view the last sale paid out or previous sale, select a fueling position and hold the * (asterisks, or star) button.

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

XEA203 and XEA203B Frequently asked questions.

CAP300-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

USING THE MODEL IQ 300 INTELLICLOCK

INSTALLATION INSTRUCTIONS

Operator s Manual Addendum

ipac Access Controller

Installing the Cisco Unified Videoconferencing 3545 MCU

3G/4G OUTDOOR ROUTER Instruction Manual

SAM4s ER180T Quick Setup Guide Copyright 2013

CB6000/CB6500 Product Manual

mypos Combo - User Manual mypos Europe Ltd. mypos Combo En

Quick Installation Guide Direct and Transfer Thermal Printer

AMERICAN CHANGER CORP.

Eltron LP 2348 Eltron 2348 ADV

Unpack the machine and its components. Cassette/Multi-purpose tray

The Big Apple (MPU4, set 1)

T4 series user s manual. Version: 1.1

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Quick Start Guide. Mounting the Essential Plus and Elite

ECASH 2000 MERCHANT OPERATIONS MANUAL

Xi4 Quick Reference Guide

EFTPOS 1. User guide.

Quick Draw Electronics. Shooting Sports Timer User Manual. Model CLUB All In One

Installing and Managing the Switch

DataPort 250 USB 2.0 Enclosure User s Guide (800)

Transcription:

QC-7600A Instruction Manual Anztec, P.O. Box 3288, Christchurch, New Zealand Phone +64 3 338 3139, www.anztec.com email:sales@anztec.com Serial # Key # Software Ver.

QC-7600A Rev 1.2 Page 2

Contents Warning...6 Configuration...6 Installation...7 Overview...7 Using the Menu System...7 Start Up...8 Reset Meters and Events to zero...9 Load Tokens and Coins...10 Daily Management...11 Overview...11 Entering The Attendant Menu...12 Event Log...13 Accountancy...14 Terminal Credit Meter...15 Cancelled Credit Meter...15 Machine Reconciliation...15 Site Config...16 Site Name...17 Site Address...17 GST and ABN Number...17 Receipt Message...18 Tax Number Type, GST or ABN...18 Purchase Value...18 Set Date And Time...20 Printing...21 Hopper Count...22 Clear Short Term Meters...23 Refills...24 System Reset...25 Status...26 Credit Card Transaction Controller...27 Overview...27 Accessing...27 Menu Access...28 Menu Options...29 System Status...29 View Event Log...30 Refund Purchase...31 Manual Purchase...32 Test Transaction...33 Last Transaction Response...34 Configure Network...35 Configure E-Commerce...36 Configure Email and Alerts...37 Card Reader...38 Update System...39 QC-7600A Rev 1.2 Page 3

Network Status Display...41 Reset to Default IP Address...41 Card Test Transaction...42 Network Status...42 Network Settings...42 Installing Printer Paper...43 Loading paper Auto Load...43 Unloading paper...45 Mounting Guide...46 Recommended Wall Cutout...47 While every effort has been made to ensure that the information contained in this literature is accurate, Anztec reserves the right to amend the size and specifications of this machine in line with its policy of continuing improvement and development QC-7600A Rev 1.2 Page 4

Security As with any piece of cash handling equipment security is paramount to ensure the theft of money, tokens, credit card details etc does not occur. Once a machine or component is delivered to a distributor or end user it is their responsibility to ensure that the machine or component is kept secure at all times. Opening the secure cabinet to perform cash clearance, refills, and routine maintenance may expose the machine to security compromises. The distributor or end user must manage security issues using their own documented security procedures. Anztec accepts no responsibility for security compromises caused by lapses or deficiencies in distributor or end user security procedures or controls. While by no means a comprehensive list, the following are some suggested guidelines to help keep the machine secure: Track and Log Location of the machine. Who opened a machine, for what reason, and when. Components removed from machine for repair or replacement. Inspection Check exterior of the machine regularly for tampering. Check for installations that are unsecured or substandard. This includes associated equipment such as cables and network routers/modems. Look regularly for non standard items fitted to the exterior such as card skimming devices. Look regularly for non standard items fitted to the interior. Monitor Have the machine within view of the attendant. Make sure the machine is in a well illuminated area. Use video surveillance to monitor the machine in unattended areas. QC-7600A Rev 1.2 Page 5

Personnel Ensure your employees are familiar with the operation of the machine. Check your employees are suitably qualified and authorized for any cash handling and maintenance work that is required. Limit and monitor access to cabinet keys to reduce the chance of theft or tampering. Monitor third parties who access the machine for any reason. The fitting of machine components not directly supplied by Anztec may result in security being compromised. Anztec accepts no responsibility if this situation occurs. Warning Warning Never remove, unplug, or replace any components inside this machine without first turning off the mains power. Failure to comply may result in damage to your machine and void your warranty. Configuration The QC-7600A is configured to customer or distributor specifications prior to leaving Anztec s production facility. Configuration includes items such as the designation of hoppers as coin or token, the value of those coins or tokens, and additional bonus payout features. The Accountancy meters that are available are also dependant on configuration. Details of the factory configuration of this machine are attached as a separate page to the back of this manual If you require further information on the configuration of the equipment you have received please contact your supplier. QC-7600A Rev 1.2 Page 6

Installation Overview To prepare your QC-7600A for use, you need to: Connect the machine to a power source. Connect the machine to the internet and configure. Reset the system. (PIN number required) Load the tokens/coins and enter the refill amount in the Refills menu. The following installation start up instructions tell you how to do this. Using the Menu System When in the attendant menu you are able to select the required options using two methods. 1. Where there is an arrow pointing to the top item of a menu pressing the # key will enter that menu. Use the A and B keys to scroll up and down through all menu options. ATTENDANT MENU A=Up B=Down 1 : Event Log 2 : Accountancy 2. If you know the menu number or can see it on the display just press the appropriate number key on the alpha numeric keypad to access it directly. For the example above just press number 2 to enter the Accountancy menu. When entering information into the unit the following keys have the functions below. The A key deletes a character. The 0 key inserts a space. Pressing the B key changes to uppercase followed by lowercase (Abc), all uppercase (ABC), or all lowercase (abc). The letter Z is after the letter Y but is not shown on the keypad. QC-7600A Rev 1.2 Page 7

Start Up To start the machine: 1. Unpack and install the equipment supplied. 2. Open the Main Door of the machine. 3. Plug the QC-7600A power cord into the internal three pin socket. Plug the other end into a mains supply outlet. Use the P-clip supplied to strain relief the power cord. 4. Plug your network cable into the RJ45 network socket. Note: Credit card functionality will need to be setup using the Credit Card Transaction Controller instructions in this manual. 5. Remove the Transit Screw from the printer if fitted. 6. Switch the unit on using the Mains Switch on the Power Supply Front Panel 7. Fit printer paper if not pre-loaded. (See section in this manual) QC-7600A Rev 1.2 Page 8

Reset Meters and Events to zero To reset the meters and events to zero: 1. Apply power to the QC-7600A 2. Open the front door. 3. To enter the Attendant Menu on the attendant LCD inside the machine press the # key. ATTENDANT MENU Press # to enter attendant mode ATTENDANT MENU A=Up B=Down 1 : Event Log 2 : Accountancy 4. Using the A and B buttons scroll up and down through the Attendant Menu until you see the System Reset option, option 9, and then press button 9 to enter. RAM CLEAR Enter PIN #=Ok *=Cancel 5. Enter your PIN number and press the # button to clear the meters and events. (Contact your supplier to obtain the PIN number) The machine will automatically reset and return to the initial attendant menu. 6. Check and set the date time using the Set Date Time options in attendant menu 6. (see page 13) The machine has now been reset to zero and is ready to accept currency. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 9

Load Tokens and Coins To refill a Token or Coin hopper: 1. Insert your tokens or coins into the appropriate hopper while it is in situ, taking care to ensure you know the number of inserted tokens or coins. 2. Enter the Attendant Menu and using the A and B buttons scroll up and down through the Attendant Menu until you see the Refills option, and then press button 8. 3. The Refills Hopper menu will appear. REFILLS-HOPPERS Hopper Location Hop1 Hop2 Hop3 1 : $X.XX 3: $X.XX 2 : $X.XX 4. Press Button 1. 5. Enter the number of tokens or coins for the selected hopper and press #. Hopper 1 - $X.XX Enter value to add $X.XX coins #=ok *=cancel 6. Press # to confirm or * to cancel. Refill hopper Hopper 1: $X.XX Add xxx coins (X) #=ok *=cancel 7. Repeat steps 5 to 7 to refill the other hopper denominations. 8. To exit this menu and return to the Attendant Menu, press the * button. 9. Close the front door of the QC-7600A. The Anztec QC-7600A should now be ready for use. QC-7600A Rev 1.2 Page 10

Daily Management Overview Once you have installed the QC-7600A, you can enter the Attendant Menu to perform the following functions when required: Access Event Log Access Accountancy Menu Print Events and Meters Manage Refills Clear Short Term Meters The following daily management instructions show you how to do this. QC-7600A Rev 1.2 Page 11

Entering The Attendant Menu To enter the Attendant Menu on the QC-7600A, unlock and open the main door, and then press the # key. ATTENDANT MENU Press # to enter attendant mode Once this is done the Attendant Menu will appear on the attendant LCD inside the machine. ATTENDANT MENU A=Up B=Down 1 : Event Log 2 : Accountancy Use the A and B buttons on the keypad scroll up and down through the Attendant Menu. Press the number button on the keypad that corresponds to the Attendant Menu sub-menu you wish to enter. A list of the sub menus is as follows: 1. Event Log 2. Accountancy 3. Site Config 4. Set Date Time 5. Printing 6. Hopper Count 7. Clear Short Term Meters 8. Refills 9. System Reset 0. Status To exit the Attendant Menu close the main door. QC-7600A Rev 1.2 Page 12

Event Log The QC-7600A has an Event Log which is accessible while in the Attendant Menu. 1. Press button 1 while in the Attendant Menu. The number in brackets shows the number of events in the system. EVENT LOG (XXX) Last Event Last Event 2. Press button A to scroll up or B to scroll down through the events. 3. Press the # button to display more detail of the event at the top of the event list. Event X of XXX DD MM YYYY HH : MM : SS Last Event 4. Press the * button to return to the main event list. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 13

Accountancy The QC-7600A has meters which are accessible while in the Attendant Menu. 1. Press button 2 to enter Accountancy Menu. ACCOUNTANCY 1: Short Term Meters 2: Long Term Meters 2. Press button 1 to view Short Term Meters or 2 to view Long Term Meters. SHORT TERM METERS Credit Card Qty : 0 Value : $0.00 LONG TERM METERS Credit Card Qty : 0 Value : $0.00 3. Press button A to scroll up or B to scroll down through the meters. $0.10 Coins In Button 1: $X.XX $0.20 Coins In Button 2: $X.XX $0.50 Coins In Button 3: $X.XX $1.00 Coins In Button 4: $X.XX $2.00 Coins In Credit Card Total Total Coins In Grand Total In $5.00 Notes In #1 $X.XX Hop 1 Out $10.00 Notes In #1 $X.XX Hop 1 Level $20.00 Notes In #1 $X.XX Hop 1 Refill Total Notes In #1 $X.XX Hop 2 Out $5.00 Notes In #2 $X.XX Hop 2 Level $10.00 Notes In #2 $X.XX Hop 2 Refill $20.00 Notes In #2 $X.XX Hop 3 Out Total Notes In #2 $X.XX Hop 3 Level Total Notes In $X.XX Hop 3 Refill Grand Total Out Total Coins Out Last Reset Bonus Paid Cancelled Credit Terminal Credit 4. The meters available are: QC-7600A Rev 1.2 Page 14

Terminal Credit Meter Terminal Credit is the amount left to pay out if a hopper runs empty and the customer has not received their full pay out. Completing a Hopper Refill on the empty hopper and then exciting the attendant menu into normal operation will cause the remaining amount to pay out. The Terminal Credit value will then be reset to zero in the meters but the number of Terminal Credit events will still be shown. Cancelled Credit Meter Cancelled Credit is the amount left to pay if there is a power failure during a transaction. By looking at this meter the amount still owing to the customer can be seen. This meter can only be cleared by a Clear Short Term Meters in option 7 of the attendant menu. This will also clear all other Short Term Meters. Machine Reconciliation From the accountancy meters the Grand Total In is able to be reconciled with the Grand Total Out using the following formula. Grand Total Out - Bonus Paid + Cancelled Credit = Grand Total In To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 15

Site Config The QC-7600A allows you to set the site configuration while in Attendant Menu. 1. Press button 3 while in the Attendant Menu. SITE CONFIG 1 : Show Current 2 : Site Name (Line 1) *=Main Menu 2. Press button 1 to show current site name and other site details. 3. Press buttons 2 to 9 to set more site details. The following are the corresponding details to numbers on the keypad. Alternatively use the A and B buttons to scroll up and down through the selections to view. 2. Site Name (Line 1) 3. Site Name (Line 2) 4. Address (Line 1) 5. Address (Line 2) 6. GST or ABN Number (Type selected in option 8 of this menu) 7. Receipt Message 8. Tax Number Type, GST or ABN 9. Purchase Value 4. Use the alpha numeric keypad to on the power supply to enter details into each category as required, see further instructions below. The A key deletes a character. The 0 key inserts a space. Pressing the B key changes to uppercase followed by lowercase (Abc), all uppercase (ABC), or all lowercase (abc). The letter Z is after the letter Y but is not shown on the keypad. QC-7600A Rev 1.2 Page 16

Site Name To set the site name use the alpha numeric keypad. Press the # key once completed. Repeat for line two if required SITE NAME (LINE 1) Abc XXXXXX #=Ok *=Cancel Site Address To set the site name use the alpha numeric keypad. Press the # key once completed. Repeat for line two if required SITE ADDRESS (LINE 1) Abc XXXXXX #=Ok *=Cancel GST and ABN Number To set the GST or ABN number, use the alpha numeric keypad. Press the # key once completed. GST NUMBER Abc XXXXXX #=Ok *=Cancel QC-7600A Rev 1.2 Page 17

Receipt Message To set the site name use the alpha numeric keypad. Press the # key once completed. RECEIPT MSG Abc XXXXXX #=Ok *=Cancel Tax Number Type, GST or ABN To set the tax number type, use the alpha numeric keypad. Select 1 for GST, 2 for ABN. The current selection is shown. Press the # key once completed. SELECT TAX TYPE 1 - GST (Current) 2 - ABN #=Ok *=Cancel Purchase Value Note: Only enabled in some software versions. To set the purchase value, use the alpha numeric keypad. Restore defaults or select the front panel button you want to change the value of, Button 1, Button 2, Button 3 or Button 4. PURCHASE VALUE 1: Restore Defaults 2: Button 1 - $XX.XX #=Select *=Cancel Button 1 Button 3 Edit Button 3: Button 2 - $XX.XX 4: Button 3 - $XX.XX #=Select *=Cancel Button 2 Button 4 QC-7600A Rev 1.2 Page 18

Enter the value you want to assign to that button. Button 1 $X.XX #=Ok *=Cancel Confirm that value by pressing the # key. PURCHASE VALUE # = Set to $XX.XX * = Cancel Change the value of any other buttons Press the # key once completed. Carry out a full system reset (see System Reset) to make ensure the accountancy will match the new purchase values. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 19

Set Date And Time The QC-7600A has a Date and Time feature which you can set while in the Attendant Menu. 1 Press button 4 while in the Attendant Menu. SET DATE AND TIME 08-06-09 14 : 22 : 01 dd mm yy hh:mm:ss 2 Enter the Date and Time values using the keypad. Use the C button to move the left and the D button to move to the right to select individual values to adjust. 3 Press the # button to save or the * button to cancel the entry. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 20

Printing The QC-7600A has a Print function which is accessible while in the Attendant Menu. From the Print Menu you can print copies of the Long Term and Short Term Meters, Events, and a test page. 1. Press button 5 while in the Attendant Menu to display the main Print Menu. PRINTING 1: Accountancy 2: Events 3: Test Page 2. Press button 1, Accountancy, to print out Short Term meters, Long Term meters or both. PRINT ACCOUNTANCY 1: Short Term 2: Long Term 3: Both 3. Or press button 2 on the main Print Menu to print All Events, New Events, or a Specified number of events. New Events are events that have occurred since the last event printout. PRINT EVENTS 1: All Events 2: New Events 3: Specify Number 4. Or press button 3 on the main Print Menu to print a test page. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 21

Hopper Count The QC-7600A has a Hopper Count function which is accessible while in the Attendant Menu. This allows the hoppers to run and count the remaining coins as they are ejected. 1. Press button 6 while in the Attendant Menu to enter the Hopper Count Menu. Hopper Count 1: Hopper 1 - $X.XX 2: Hopper 2 - $X.XX 2. Select either, Hopper 1, Hopper 2, or Hopper 3. 3. The Hopper will begin to pay out tokens or coins. Hopper Count Hopper 1 : 0 $X.XX In progress 4. Press * to stop the count and then # to cancel or * to resume. 5. The Hopper count will show Completed when hopper is empty. It is advisable to manually check the hopper is completely empty. Note: Care must be taken when re-inserting hoppers after removal to avoid damage to the hopper connection pins in the machine Hopper Count Hopper 1 : 0 $X.XX Completed To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 22

Clear Short Term Meters The QC-7600A has Short Term Meters which you can clear while in the Attendant Menu. 1 Press button 7 to enter Clear Short Meters Menu. RAM CLEAR Enter PIN #= Clear *=Cancel 2 Enter the PIN and press the # button clear the Short Term Meters. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 23

Refills To refill a Token or Coin hopper: 1. Insert your tokens or coins into the appropriate hopper while it is in situ, taking care to ensure you know the number of inserted tokens or coins. 2. Enter the Attendant Menu and using the A and B buttons scroll up and down through the Attendant Menu until you see the Refills option, and then press button 8. 3. The Refills Hopper menu will appear. REFILLS-HOPPERS Hopper Location Hop1 Hop2 Hop3 1 : $X.XX 3: $X.XX 2 : $X.XX 4. Press Button 1. 5. Enter the number of tokens or coins for the selected hopper and press #. Hopper 1 - $X.XX Enter value to add $X.XX coins #=ok *=cancel 6. Press # to confirm or * to cancel. Refill hopper Hopper 1: $X.XX Add xxx coins (X) #=ok *=cancel 7. Repeat steps 5 to 7 to refill the other hopper denominations. 8. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 24

System Reset The QC-7600A has a System Reset feature which you can set while in the Attendant Menu. 1 Press button 9 while in the Attendant Menu. RAM CLEAR Enter PIN #=Ok *=Cancel 2 To clear all Short Term and Long Term Meters and all Events enter your PIN number and press the # key. (Contact your supplier to obtain the PIN number) The machine will automatically reset and return to the initial attendant menu. Site ID, Purchase Values, and Number of Power-ups are not reset. To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 25

Status The QC-7600A has a Status menu which you can view while in the Attendant Menu. 1 Press button 0 while in the Attendant Menu. SYSTEM STATUS QC7600 Ser:0000000000000000 ----------------------------- 2 The initial screen shows the machine type and serial number. 3 Use the A and B buttons to scroll up and down through this menu to show the status of: Hop 1 Ready Hop 2 Ready Hop 3 Ready Val 1 Connected Val 2 Connected Coin Mech Connected Printer Enabled Card Connected To exit this menu and return to the Attendant Menu, press the * button. QC-7600A Rev 1.2 Page 26

Credit Card Transaction Controller Overview The Anztec Credit Card Transaction Controller is a web based application designed to enable you configure your Anztec carwash credit card system, access transaction history, and manage transaction issues. Accessing The Credit Card Transaction Controller The Anztec Credit Card Transaction Controller configuration is accessed via your web browser. For installations where your PC is on the same side of your router as the carwash system simply enter the default IP address below into your browser. The transaction controller uses port 85. http://192.168.1.254:85 If you are entering off site through a router you will need to ensure translation between outside IP address access and the internal IP address is enabled. 192.168.1.254 Off site PC Router with IP translation enabling connection from off site PC After successful connection through your browser the Anztec Credit Card Transaction Controller login screen will appear. QC-7600A Rev 1.2 Page 27

Menu Access Access to the configuration features of the Anztec Credit Card Transaction Controller system are controlled by password protected login. When you access the Credit Card Transaction Controller web application you will be prompted to enter a login password for the level you wish to enter. The table below outlines the features accessible from each login level Menu Item System Status View Event Log Refund Purchase Configure Network Configure E- Commerce Configure Email Alerts Miscellaneous Configuration Set Clock Update System User Attendant Supervisor Update View Edit View Edit View Edit View Edit Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes The Factory access level is used exclusively by Anztec. QC-7600A Rev 1.2 Page 28

Menu Options System Status Enter the System Status menu to view the following information: Last Transaction Transaction Status Network Status Net Registry Status Entry system Status System Clock System Information QC-7600A Rev 1.2 Page 29

View Event Log Enter the Event Log to find a list of all events from the most recent to the oldest. QC-7600A Rev 1.2 Page 30

Refund Purchase Enter the Refund Purchase menu to refund a purchase. Enter the transaction reference number and value for the refund by looking through the Event log for the required information. QC-7600A Rev 1.2 Page 31

Manual Purchase Enter the Manual Purchase menu and enter credit card details to complete a manual purchase. QC-7600A Rev 1.2 Page 32

Test Transaction To perform a test transaction click on the Perform Test Transaction button. QC-7600A Rev 1.2 Page 33

Last Transaction Response Enter the Last Transaction Response menu to obtain details of the last transaction. QC-7600A Rev 1.2 Page 34

Configure Network Enter the Configure Network menu and enter the following information: Network Interface settings System update settings Email Alert settings. Web interface settings. Default factory settings are: IP address : 192.168.1.254 Subnet Mask : 255.255.255.0 Default Gateway: 192.168.1.1 Once the fields are complete click on the apply button. Click the Restart Network button to enable the new settings to take effect. To return to the previous settings click on the cancel button. Note: When changing the IP address from its default setting to your own, you must ensure you have the address recorded, as this will be the address you need to use for your browser on the next login. QC-7600A Rev 1.2 Page 35

Configure E-Commerce Configure the E-Commerce features by entering Connection and Security information. Once the fields are complete click on the apply button. To return to the previous settings click on the cancel button. QC-7600A Rev 1.2 Page 36

Configure Email and Alerts Select Event Alerts that are to be emailed as they occur. Choose to have the Event log emailed when it has reached a user defined percentage of its total capacity. Once the fields are complete click on the apply button. To return to the previous settings click on the cancel button. QC-7600A Rev 1.2 Page 37

Card Reader Select the port on the Anztec interface board the credit card reader is attached to. Click on the update button so save the changes. QC-7600A Rev 1.2 Page 38

Update System To update the system software, enter the update filename and click on the update system button. The file update bar will appear and the system will begin to update Once the update is completed you must go to the System Status page and restart the board in order for the changes to take effect. QC-7600A Rev 1.2 Page 39

Restart Board The board will now restart. To access the Credit Card Transaction Controller you will need to log in again. QC-7600A Rev 1.2 Page 40

Network Status Display The Network Status Display is used to display basic system settings and status, run a test transaction, and reset the system to its default IP address. The Network Status Display is found inside your QC-7600A behind the hoppers. It consists of an LCD display and three selection buttons. Under normal operation the information display will cycle Ecommerce Online, Terminal Online, and the current time and date. Reset to Default IP Address At some point you may wish to reset the IP address of the machine to its original factory default, to do this follow the steps below. 1. Ensure the machine is powered off. 2. Hold down buttons 1 and 3 and turn the machine on. 3. Release buttons 1 and 3 and press button 2 at the prompt. QC-7600A Rev 1.2 Page 41

Card Test Transaction Press Button 1 to run a test transaction, swipe your card at the prompt. Once the card is swiped the first and last four numbers on the card will be displayed if the swipe is successful. Network Status Card Swipe Test Swipe Card Now Card Swipe Test XXXXXXXXXXXXXXXXX Press Button 2 to display network status, this forces a network status check. Ecommerce Online, Terminal Online, and the current time and date will be shown in an automatic sequence as per normal operation if the network is functioning correctly. Checking Network Please Wait... Network Settings Press Button 3 to display network settings, these are shown in an automatic sequence. IP Address XXX.XXX.X.XX Default Gateway XXX.XXX.X.X Subnet Mask XXX.XXX.XXX.X QC-7600A Rev 1.2 Page 42

Installing Printer Paper Loading paper Auto Load 1. The Seiko printer has an auto loading system for the paper. To begin turn the machine power off. 2. Slide the printer frame back and place your new roll of paper on the roll holder. 3. Make sure the cutter unit and platen are in a closed state as shown below. QC-7600A Rev 1.2 Page 43

4. Insert the new paper into the paper slot in the back of the printer mechanism making sure it is square, see below. 5. Push the printer back into its normal operating position. This enables the paper to feed out through the receipt slot in the front panel. 6. Turn on the machine power the paper should automatically feed into the printer. 7. If the paper doesn t automatically feed into the printer, turn off the power and try re-inserting the paper. 8. Use the reverse and feed buttons on the printer to move the paper back and forward so it is flush with the front of the printer. QC-7600A Rev 1.2 Page 44

Unloading paper 1. With the machine on, slide the printer frame back and use the reverse button on the printer to eject the paper, alternatively follow the instructions below. 2. Turn the machine power off. 3. Slide the printer frame back. 4. Press the green release lever on the side of the printer down, the platen unit should open up as shown below. 5. Gently pull the paper back through the printer from behind. 6. Push the cutter and platen units back together by pushing on the green labelled areas as shown by arrows in the diagram below. When the platen unit is closing it may stop midway depending on the gear meshing. In such cases open the platen unit by using the green release lever and then close it again. Note: The paper will have to be fully re-inserted if the cutter unit has been opened up, otherwise the paper will bunch up behind the cutter unit. QC-7600A Rev 1.2 Page 45

Mounting Guide To install the unit: Remove the angle clamping brackets from the cabinet. Push unit through the aperture from the outside until the front panel is hard against the wall. Re-bolt the clamping brackets loosely to the cabinet. Push the clamping brackets up against the wall and tighten the bolts on the cabinet to lock it into place. The forward facing bolts on the clamping brackets can be adjusted for extra tension. Plug power cord into power supply, switch on and the unit is installed. Locking Bolts Front Panel Rear door Clamping Bracket Wall thickness 100mm 200mm QC-7600A Rev 1.2 Page 46

Recommended Wall Cutout 705mm 810mm 860mm Recommended Wall Cutout and Mounting Height QC-7600A Rev 1.2 Page 47