Sample Introduction Systems SOLID LASER ABLATION -II

Similar documents
Sample Introduction Systems SOLID LASER ABLATION -II

Sample Introduction Systems SOLID LASER ABLATION

Sample Analysis Design

Discover our 193nm excimer laser systems, incorporating Laurin Technic sample cells and GeoStar Software, for the very best in LA-ICP-MS.

A full description of the principles of the Matlab code used to produce the images is given below.

Discover our 193nm excimer laser systems, incorporating Laurin Technic sample cells and GeoStar Software, for the very best in LA-ICP-MS.

Improvements in LA-ICP-MS for Trace Forensic Analysis of Common Household Products Using a Short Pulse Ultraviolet Laser

G 3. AN ELECTRONIC JOURNAL OF THE EARTH SCIENCES Published by AGU and the Geochemical Society

Outline. Nuclear Forensics & Laser-Induced Breakdown Spectroscopy. Interferometry & Shadowgraphy. Conclusion & Future Work. Experimental Setup

Lecture 24. Lidar Simulation

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS )

Probe for EPMA Purchase Justification

Particle Image Velocimetry for Fluid Dynamics Measurements

Laser Applications for Photovoltaics Crystalline and Thin Film Technologies

UV-6 Series Double Beam UV/Vis Spectrophotometers

Chapter 2: Wave Optics

Physics 625 Femtosecond laser Project

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

Using Adjustable Slits to Reduce Interfering Element Effects

Laser Applications for Photovoltaics Crystalline and Thin Film Technologies

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

LA ICP MS Analysis with

Recent Advances in Ultrafast Laser Subtractive and Additive Manufacturing

Section 2 PROGRESS IN LASER FUSION

Development of automated ultraviolet laser beam profiling system using fluorometric technique

Lecture 09. Lidar Simulation and Error Analysis Overview (1)

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS

Using LiDAR for Classification and

Laser milling for micro tooling

PARTICLE IMAGE VELOCIMETRY (PIV) AND VOLUMETRIC VELOCIMETRY (V3V) SYSTEMS

Lab 12 - Interference-Diffraction of Light Waves

EyeTech. Particle Size Particle Shape Particle concentration Analyzer ANKERSMID

Probe for EPMA: Software for Electron Probe MicroAnalysis

How to Analyze Materials

Speed of light E Introduction

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

Chapter 6 : Results and Discussion

Selective Optical Assembly of Highly Uniform. Nanoparticles by Doughnut-Shaped Beams

Supporting Information

Two slit interference - Prelab questions

specular diffuse reflection.

P recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection.

Progress of the Thomson Scattering Experiment on HSX

High-Power Femtosecond Lasers

Silicon Avalanche Photodiodes in Dynamic Light Scattering

25-1 Interference from Two Sources

AP* Optics Free Response Questions

Z-LASER Improved Beam Modeling With Optical Fibers. Vision Technology Forum April 15th, 2015

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser

Related topics Interference, wavelength, refractive index, speed of light, phase, virtuallight source.

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods Part 1: General principles

Ray Optics I. Last time, finished EM theory Looked at complex boundary problems TIR: Snell s law complex Metal mirrors: index complex

Cary Fiber Optic Probes

Product Specifications

High spatial resolution measurement of volume holographic gratings

WAVELENGTH MANAGEMENT

CODE Analysis, design, production control of thin films

Metrology for Characterization of Wafer Thickness Uniformity During 3D-IC Processing. SEMATECH Workshop on 3D Interconnect Metrology

»»»LASER GENERATION IV The Innovation for your Success

AP Physics Problems -- Waves and Light

5. Operating instructions: Octagon 200CL

CHAPTER 5 MOTION DETECTION AND ANALYSIS

Proton dose calculation algorithms and configuration data

Introduction. In-Situ Metrology for Veeco k465i GaN MOCVD WHAT BLUE BANDIT PROVIDES IN REAL-TIME: k-space Associates, Inc.

DigiPot Software Configuration Menu

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization

HyperRapid NX SmartCleave

REAL-TIME DUST AND AEROSOL MONITORING

DC - Devices and Controller

Beam Profilier - Beamage 3.0

LC-1: Interference and Diffraction

Surface and thickness profile measurement of a transparent film by three-wavelength vertical scanning interferometry

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Optical Topography Measurement of Patterned Wafers

Chapter 24. Wave Optics. Wave Optics. The wave nature of light is needed to explain various phenomena

Technical Specifications for High speed PIV and High speed PIV-PLIF system

Rapid Imaging of Microstructure using Spatially Resolved Acoustic Spectroscopy

Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components

MICHELSON S INTERFEROMETER

Introduction. Lab Kit Contents

Industrial Fiber Beam Delivery for Ultrafast Lasers

Chapter 3. Experimental Procedure

Instruction Manual of Modelling of Trap Detectors Using Matlab

Chapter 82 Example and Supplementary Problems

Agilent 10706B High Stability Plane Mirror Interferometer

Optimization of integrated optic components by refractive index profile measurements

2/26/2016. Chapter 23 Ray Optics. Chapter 23 Preview. Chapter 23 Preview

UNCOMPROMISING QUALITY

Laser Contouring Method for Wall Thickness Metrology on OMEGA Shock Breakout Targets

WAVELENGTH MANAGEMENT

Development of an Electronic Technique for Determining Rate of Solution of Solid Products

Instruction manual for T3DS calculator software. Analyzer for terahertz spectra and imaging data. Release 2.4

VDL 002 VariDelay I. Operation Manual

Error Analysis in Inverse Scatterometry I: Modeling

Figure 1: Derivation of Bragg s Law

Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J

Transcription:

Sample Introduction Systems SOLID LASER ABLATION -II

Laser ablation systems Variable power output control is an absolute must! This is required in order to achieve a suitable sampling rate, which is dependent on the sample matrix and laser beam size. E.g. an analysis using a pit or laser beam diameter of 60 microns, an ablation lasting 60 seconds results in a pit 60 microns (@1 Hz) deep (sampling rate of 1 micron/second)

Laser pits Optimal geometry consists of a symmetrical pit and flat bottom These can only result from a homogenized beam energy profile

Laser ablation systems In order to maintain reproducibility, energy meters are installed Energy meters are either placed in the beam path, or laser beam is split so that a known fraction is directed towards the meter while the remainder is focused onto the sample

Laser ablation systems

Laser ablation systems New Wave Research (Division of ESI) UP213 nm UP193 nm

Recently developed 193 nm laser systems Analyte 193H Resonetics 193 nm

Laser ablation cells Sample is contained in an air-tight cell through which a flow of gas (He) carries the ablated sample aerosol to the ICP (through tygon tubing). The ultimate goal is to design a cell that attains 100% transport efficiency since at this level laser-induced elemental fractionation (LIEF) processes taking place in the laser cell and transport system will be reduced- hence, improved ion signals and results shall be attained

Laser ablation cells use of He carrier gas

Laser ablation pits are the pits? Simonetti et al. (2008)

Laser ablation pits are the pits? zircon Simonetti et al. (2005)

Laser ablation cells Basic requirements (somewhat conflicting) Large enough to house variably sized solid samples Small enough volume in order to attain rapid sample washout and high sensitivity

Laser ablation cell Standard Cell of UP213 system

Ablate grains in epoxy mounts vs. thin sections?

SuperCell Accessory Option 1 2 3

Laser ablation cells Supercell Sample stage with slide insert Slide insert removed

Laser ablation cells Supercell

Laser ablation cells Supercell

Simonetti et al. (2008)

Analyte 193 nm system Frames Cell The FRAME defines the gas volume, mixing and flow dynamics of the chamber as seen with the teardrop frame. The sample chamber can be fitted with FRAMES that accommodate various shapes, sizes and quantities of samples. The use of FRAMES allows the sample chamber to be reconfigured by the user to with the latest designs that yield optimal signal strength, washout time and signal stability.

Resonetics Laurin two volume sample cell Laurin Sample Cell Minimal elemental and isotopic fractionation. Smooth signal down to 1Hz laser repetition while retaining washout performance for optimal depth profiling and spatial resolution when scanning. Sensitivity and fractionation independent of sampling position in the cell

Resonetics Laurin two volume sample cell Müller et al. (2009) JAAS

Resonetics Laurin two volume sample cell Effective volume of ~1-2 cm 3, funnel-shaped inner cell (hole at the bottom) Funnel is above a sample holder in an air-tight sample cell box with a volume of 380 cm 3 Funnel remains stationary and sample box moves Samples are held and pushed upwards by springs and thus eliminating the need for refocusing of the laser and viewing system

Importance of laser ablation cell design - LIEF Sylvester (2008) GAC Short Course volume 40

Importance of laser ablation cell design - LIEF Günther & Koch (2008) GAC Short course volume 40

Sylvester (2008) GAC Short Course volume 40

Laser ablation analyses Calibration choice of an appropriate standard Ideally you would use a solid sample that is well characterized and homogeneous and has the same (matrix) properties as your sample i.e. matrix-matched (Sylvester, 2008) At times, this can prove somewhat difficult.

Laser ablation analyses Internal Standardization in general, the signal from the laser is dependent upon the amount of material ablated However, the amount of material ablated van vary due to: variations in laser-sample coupling (how effectively laser ablates sample), variations in laser power, variations in transport efficiency

Laser ablation analyses Internal Standardization Typically, use an element contained in your standard material ( external standard ) that has been accurately determined by another in-situ, high resolution method of analysis (e.g. electron microprobe) this is then referred to as the internal standard (IS) In minerals, we often use CaO (wt%) or SiO 2 (wt%) obtained from electron microprobe analysis (but can use any other element) as long as it is well characterized and doesn t overlap with major ICP-MS spectral interferences This calibration process allows for any variations in ablation, transport, and laser power to be accounted for

Laser ablation analyses Theory behind trace element abundance calculations: where: conc ni = (cpsn ij /abundance j ) / (yield ni ) conc ni = the concentration of element i in analysis n cpsn ij = the mean count rate (background-subtracted) of isotope j of i in analysis n abundance j = natural abundance of isotope j yield ni = cps per ppm of element i in analysis n

Laser ablation analyses The yield of element i in analysis n is determined by: where: yield ni = yield ns * Int(yield ni / yield ns ) std yield ns = cps per ppm of the internal standard s in analysis n Int(yield ni / yield ns ) std = the ratio of the yield of element i in analysis n to the yield of the internal standard s in analysis n, interpolated over the standard analyses.

GLITTER On-line, interactive data reduction software package for laser ablation-icp- MS instrumentation GLITTER - GEMOC Laser ICPMS Total Trace Element Reduction software package

Laser ablation STANDARDS element abundance determinations For silicate minerals, typically use NIST (National Institute Standard Technology; http://www.nist.gov/ index.html) fused glass beads (Standard Reference Material SRM) SRM NIST 610 elements present @ ~500 ppm SRM NIST 612 elements present @ ~50 ppm SRM NIST 614 elements present @ ~1 ppm

Laser ablation STANDARDS - element abundance determinations APATITE Durango (e.g. Trotter & Eggins, 2006, Chem. Geol.; Simonetti et al., 2008, Archaeometry); GARNET PN2 (Canil et al., 2003, CJES) ZIRCON 91500, Mudtank, BR266, GJ-1 (Wiedenbeck et al., 1995; Geostand. Newsletter; Hoskin & Schaltegger, 2003, Mineral. Society Reviews; Jackson et al., 2004)

Laser ablation STANDARDS isotopic analysis Common Pb: SRM NIST 610, 612 U-Pb dating: ZIRCON 91500, BR266, Mudtank, Temora, Plešovice, GJ-1 TITANITE Khan APATITE Madagascar, Emerald Lake, and Kovdor - Hf isotope measurement: - ZIRCON BR266, Plešovice

Laser ablation STANDARDS The GLITTER software is loaded with several commonly used standard reference materials, e.g. SRM NIST glasses However, new external standards can be uploaded within the software

Laser ablation Laser ablation sample cell should house the unknown sample and standard material simultaneously Typically, a sequence of laser ablation analyses of unknowns are bracketed (before and after) by analyses of standard material referred to as Standard- Sample Bracketing technique

Laser ablation Time-resolved spectra (time vs. ion signal intensity cps) Analysis includes an interval prior to the start of the laser ablation process for measurement of the background or baseline (cps) usually in the order of 45 to 60 seconds

Laser ablation Background measurement is followed by ablation of sample for a duration of ~60 seconds or less for most applications The duration of the ablation experiment is a function of: Abundances of elements under investigation Coupling efficiency of material being ablated Thickness of your sample section

Laser ablation In GLITTER, time-resolved spectra is accessed via the Review Signal Selection option In this window, you select your background, sample ion signal plateau, and the isotope to monitor

Laser ablation GLITTER

Laser ablation Lack a well characterized standard? One option is to report elemental ratios and not absolute abundances However, when doing so, user is assuming that elemental ionization is identical for all elements during the ablation process (in cell), transport and within the plasma itself This assumption holds true or is within the typical analytical uncertainty associated with laser ablation analyses (i.e. 5 to 10%) when Mass difference between elements being investigated is kept to a minimum!

Laser ablation sampling strategy? Single spot vs. Rastering? LIEF (laser induced elemental fractionation) is a progressive change in the ratios of measured signals of certain element pairs with the increasing number of laser pulses applied to the sample LIEF may occur at: Ablation site (result of evaporation/condensation processes) During transport to the plasma In the plasma itself (incomplete volatilization of particles)

Laser ablation Previous studies have indicated that complete atomization and ionization of laser ablated particles is subject to their size and composition, and temperature (plasma) and particle trajectory Overall, LIEF consists of two components: constant bias resulting from non-stoichiometric ablation; time-dependent fractionation that results in a change in the particle composition, number and size during the laser ablation process

Laser ablation particle size distribution Several previous studies have shown that the size distribution of particles produced during laser ablation exert a significant control on the nature and size of elemental and isotopic fractionation Major factors affecting the size distribution of particles making their way to the ICP source are: the fluence wavelength pulse duration of the laser the aspect ratio of pit composition of the sample carrier gas the size-dependent transport efficiency of the ablated particles.

Laser ablation It has also been shown that particle size distribution changes during a single analysis subject to the parameters listed above but it also depends on absorption of laser radiation by the sample (Horn et al. 2001) and the sampling strategy, i.e. scanning (raster) or stationary (single spot) ablation.

Laser ablation sampling strategy Sampling strategies using different types of laser. SEM images of static (left image) and scanning (right image) ablation craters in NiS produced with a nonhomogenized 266 nm Nd:YAG laser (Kosler, 2008)

Laser ablation sampling strategy Optical microscope images of laser craters produced by static ablation (side view, crater diameters are 30 and 60 µm) and box raster laser scanning in zircon ablated by a non-homogenized 266 nm Nd:YAG laser (modified from Košler & Sylvester 2003),

Laser ablation sampling strategy SEM images of box raster and single laser pits produced by a nonhomogenized 196 nm femtosecond laser in zircon (left image) and a corresponding detail of the bottom of the laser crater (right image).

Laser ablation sampling strategy The major difference between stationary vs. rastering sampling modes is a rapid decrease in particle size and signal intensity for ablation with stationary beam compared to more steady signal and less change in particle size distribution while the laser beam scans across the sample surface.

Temporal variations of mass concentrations of particles determined by a TSI DustTrak 8520 laser photometer which has a capability to detect particles >0.3 µm (data from Košler et al. 2005a). The aerosol was generated by ablating silicate NIST-612 glass in He atmosphere with a 266 nm Nd:YAG laser fired at 10 Hz repetition rate.

Laser ablation sampling strategy Scanning Almandine Static Pyrope

Laser ablation sampling strategy Stationary vs. Scanning (rastering) of almandine and pyrope garnet: The laser ablation conditions were similar to those used for trace element analysis in silicate minerals The laser was a 213 nm Nd:YAG, 10 Hz repetition rate and 3 J/ cm 2 for 90 seconds (total of 900 pulses) Produced round laser pits that were 25 and 40 µm in diameter in the garnets 150x25 and 150x40 µm trenches were produced by using identical ablation conditions while moving the stage under stationary laser beam at a speed of 10 µm/s. Volume of ablated material calculated from dimensions of craters The results suggest that the volume of ablated material while using laser scanning mode is ca 15% larger compared to the volume of material removed during stationary ablation, irrespective of laser beam diameter and color of the garnet.

Laser ablation sampling strategy However, The total number of counts obtained from laser scanning during ablation of different sample matrices and for different lasers and ablation conditions is 20 100% larger compared to signal intensities obtained from stationary ablation sampling The ablation time required for achieving comparable precisions by the two sampling strategies is at least 20% shorter for laser scanning and accordingly, the spatial resolution of laser scanning ablation is similar, or better, compared to the stationary ablation.

Laser ablation sampling strategy & imaging prerequisite SEM photo of ablated zircon Cathodoluminescence photograph of same zircon grain

Laser ablation - summary Laser ablation is an excellent tool for semiquantitative to quantitative analysis of many geological/solid samples Realistically, you should expect anywhere between 5 to 10% RSD (relative standard deviation @ 2 sigma level) for precision on elemental abundance determinations Benefits of spatial resolution outweigh any drawbacks Choice of appropriate, matrix-matched external standard material, optimization of instrument parameters (both laser and ICP-MS instrument), and selection of sampling strategy are critical parameters for accuracy and precision

Laser ablation data GLITTER Elemental abundances are reported in an excel compatible.csv file One Sigma Error - The one sigma error estimates use N counting statistics on the signal and background counts, propagated through the equations. An assumed 1% uncertainty (relative) on the elemental concentrations of the reference material, and a 3% uncertainty (relative) on the values of the internal standard is propagated throughout the calculations. These values can be changed, or turned off completely by the user via the Options window.

Laser ablation data - GLITTER The Minimum Detection Limit - The detection limit (MDL) at the 99% confidence level is determined by Poisson counting statistics: MDL = 2.3* (2B) where B is the total counts in the background interval.