Veeder-Root brand Series S628 Strain Gauge (S628-6XXX)

Similar documents
Series S628 AC Volts/Amps (S628-3XXX) Veeder-Root brand. Technical Manual

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

INSTAL.LATION PANEL MOUNTING

Operating Instructions tico 735 AC Volts/Amps Indicator

Veeder-Root brand C346 Preset Counter Rate Meter Time Counter

Introduction. Features. Index

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Veeder-Root brand. Squire Dual Preset Counter. Technical Manual

DUAL COLOUR DISPLAY DC PROCESS INDICATOR. Product Manual

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

DUAL COLOUR DISPLAY TEMPERATURE INDICATOR. Product Manual

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Operating Manual. Dynisco /8 DIN Indicator Concise Product Manual

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Trident and Trident X2 Digital Process and Temperature Panel Meter

Model No Universal Input Indicator Start-up Guide

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

The HPV Explorer is a serial communication program used to work with the HPV 600/900 s parameters via a computer s serial port

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

PD765 TRIDENT. Trident Series Process & Temperature Meters.

High Voltage DC Meter

TECHNICAL MANUAL Count Advanced

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

PD765 TRIDENT. Trident Series Process & Temperature Meters.

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

C160 Wall-/Pipe Mounted Universal Process Indicator

MAG. Explorer. Reference for the latest revision of the Magnetek Explorer software

From lab to production, providing a window into the process. Universal Input Indicator Start-up Guide. Operating Manual.

LCI User Manual mantracourt.com

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

SA SERIES Arlingate Lane, Columbus, Ohio (614)

7561-PSD Manual Portable Battery Powered Indicator

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Global Water globalw.com. Global Water. Instrumentation, Inc.

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

HIGH-VOLTAGE DC METER

Digital Indicator Solutions

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

LCI Load Cell Junction Box with Fault Monitor

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

dual-line 6-dIGIt process MeteR

PC 150. Digital Bench Scale. Operation Manual

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

/8 DIN Universal Process Indicator

ES-600 Ozone Controller Operation Manual

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Wall-/Pipe Mounted Universal Process Indicator

Solid State Relays with Failure Detection Function

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MODEL DSI-1000 INCLINOMETER READOUT JEWELL INSTRUMENTS, LLC. 850 Perimeter Road Manchester, NH 03103

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

7511 / / / 711 / / 731 / Preset 27

Hybrid AC Driver [GCNC-1110]

+GF+ SIGNET ph/orp Transmitter Instructions

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

H3CA-8H-AC/100/110/120

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Process & Temperature Digital Panel Meter

Tempco Instruction Manual

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

LCp-100 Weight Indicator/Transmitter

Instruction Manual. Instrument Amplifier HE 017

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Model Number Structure

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

IPM650 Intelligent Panel-Mount Display

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model Number Structure

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

signo 727 SSI operating instructions

02/11/2015

Series CTA CAP TORQUE TESTERS. User s Guide

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

FA-2448 SIX POSITION Filter Wheel

Universal power supply

UniPak UP448 Bridge Input Isolating Signal Conditioner

EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual

FLOW MONITOR & TRANSMITTER

Instruction and Operation Manual

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

Transcription:

Introduction Your Veeder-Root brand S628 Strain Gauge is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed to provide instant visual feedback regarding an application s key input value, the S628 not only has a 0.71 high LED display (27% larger than other 1/8 DIN units), but also the ability to change display color based on process status (programmable parameter in Operation Mode). Easy programming is made possible via a help function and a secondary legend display. This manual will guide you through the installation and wiring of your S628 unit with information on proper panel mounting and rear terminal layout and wiring instructions. In addition, the instrument s operation, programming, and configuration modes are thoroughly explained. The Operation Mode provides day to day operation and allows editing of preset values. The Program Mode enables the configuration of various parameters prior to initial operation. These parameters include those for basic configuration as well as other settable features which will enhance the functionality and usability of the device. The Configuration Mode allows selection of how outputs and special functions are utilized. This manual also provides information on the S628 Strain Gauge's alarms; transistor, relay, and linear outputs; product specifications; and ordering and warranty procedures. Features AWESOME 0.71 high digit LED display Programmable color change display based on an event Programmable help function and secondary legend display High and low alarm outputs Compatible with 6 wire strain gauge inputs Field selectable 5 or 10 Volt, 60 ma excitation voltage Tare function Standard outputs: two NPN transistors & one relay (optional 2nd relay) 100 ms sample time with 0.03% accuracy Optional RS-485 plug in card CE approved Index Installation Panel Mounting page 2 Wiring page 3 Operation Front Panel page 4 Operation Mode page 5-6 Programming Program Mode page 7-10 Configuration Configuration Mode page 11-13 Appendix A Specifications page 14 General Notes page 15 Ordering Information page 16 Warranty page 16 Technical Manual 702139-0005 Veeder-Root brand Series S628 Strain Gauge (S628-6XXX)

I N S T A L L A T I O N PANEL MOUNTING 100mm 82344 48mm 96mm 10mm 92mm +0.5-0.0 PANEL CUTOUT SIZE 45mm +0.5-0.0 Mounting Grooves 10 11 12 14 15 16 17 18 19 20 2 3 4 5 6 7 8 The instrument can be mounted in a panel with a thickness of up to 6mm. The cutout(s) should be made based on the recommended panel opening illustrated in the drawing above. Insert the unit in the panel through the cutout. Ensure that the panel gasket is not distorted and the instrument is positioned squarely against the panel. Slide the mounting clamp into place on the instrument, as shown to the left, and push it forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are seated in the mounting grooves on the side of the unit. The electronic components of the instrument can be removed from the housing after installation without disconnecting the wiring. To remove the components, grip the side edges of the panel and pull the instrument forward. Take note of orientation of the unit for subsequent replacement in the housing. 24 23 22 Bracket Arm 2

I N S T A L L A T I O N WIRING REAR TERMINAL CONNECTIONS Positive Digital Input Power Supply Relay 1 RS-485 Comm. B A COM 14 15 16 17 18 19 20 Relay 2 Strain Gauge Inputs The S628 accepts a 6 wire strain gauge input. Terminals #1 and #2 are used for the negative and positive inputs repectively. Terminal #5 provides the negative side of the bridge excitation, while Terminal #6 is used for the positive supply. Terminals #3 and #4 are used to sense the excitation voltage supplied to the bridge and compensate for errors due to lead resistance or drift in the exctitation voltage. Linear Output Negative 10 11 12 2 3 4 5 6 7 8 24 23 22 Control/Digital Inputs A digital input board, which utilizes Terminals #16 & #17, can be installed as an option. The input can be programmed in Configuration Mode to perform one of two functions: - Tare: When activated, the unit will create an automatic offset by referencing the currently measured value as the new zero point. - Security: When activated, the Program and Calibration Modes will not be accessible from the front panel. Please note that this option is mutually exclusive with the RS-485 serial communication option. NPN Out 2 Common NPN Out 1 Supply + Supply - Supply Sense + Supply Sense - Signal + Signal - Transistor Outputs Your unit comes standard with 2 NPN outputs which are activated by each of the alarms. Transistor Output 1, which is tied to Alarm 1, is on Terminal #7. Transistor Output 2, which is tied to Alarm 2, is on Terminal #9. Terminal #8 serves as the common connection for both transistor outputs. Relay Outputs Your unit comes standard with a relay output which is tied to Alarm 1. Terminal #19 is NC, Terminal #20 is common, and Terminal #21 is NO. A second relay output tied to the operation of Alarm 2 can be added as an option at the time of order or later installed in the field. Terminal #22 is NC, Terminal #23 is common, and Terminal #24 is NO. Input Power For an AC powered unit, Terminal #13 serves as the line or Hot side connection for AC powered units and as the positive side for DC powered units. The neutral side for AC powered units and the negative side for DC powered units are connected to Terminal #14. Serial Communication An RS-485 communication board, utilizing ASCII protocol, can be installed as an option. Terminals #16 & #17 serve as the B and A connections respectively, while Terminal #18 is connected as the common. Linear Output An option board may be installed that provides a 10 bit linear output signal relative to the Process Value. Terminal #12 is the positive side of the connection, and Terminal #10 is the negative side. The default range of the output is 4-20 ma, but can be changed via the Configuration Mode to 0-20 ma, 0-10 VDC, 2-10 VDC, 0-5 VDC, or 1-5 VDC. Terminals 11 & 15 are not used. 3

O P E R A T I O N FRONT PANEL 82345H Output Indicators Secondary Display Primary Display Down Key Scroll Key Program Key Reset Key Key Functions Key Functions Key Function Key Function In Config. mode: Holding down both keys for 3 seconds will cause the unit to return to Operation Mode. In Operation & Program Modes: Holding down both keys for 3 seconds will cause the unit to enter to Config. Mode. Down In Operation Mode: Used in Edit Operation to decrement the digit highlighted by the Scroll key. In Program & Config. Modes: Used in Edit Operation to decrement the digit highlighted by the Scroll key, if the setting is a numerical value, or present the next in the series of choices for that parameter. Down & Program 4 Scroll Program Reset Down & Scroll In All modes: Moves the unit into Edit Operation, which is indicated by the left most digit flashing. Successive presses of the key are used to move to the digit to be edited. Wrap around will occur from least significant digit to most significant digit. In Operation Mode: Used to move between the process value display & the presets and to enter an edited preset value. Holding the key down for 3 seconds will cause the unit to enter Program Mode. In Program Mode: Used to move from one parameter to the next and enter the edited parameter values. Holding the key down for 3 seconds will cause the unit to return to Operation Mode. In Config. Mode: Used to move from one parameter to the next and enter the edited parameter values. In Operation Mode: Resets a latched alarm if pressed while the process value is being viewed. Pressing this key while viewing the max or min value will cause those values to be reset. In Program & Config. Modes: No function. In All modes: Will abort an Edit Operation and return the preset/parameter to its previous value. Key Primary Secondary Output Indicators Display Functions Function In Operation Mode: Default display is the Process Value. Can be scrolled using the program key to display other Operation Mode values. If the "Help" function is enabled, this display will first show the parameter description for 3 seconds (example - page 6). In Program & Config. Modes: Displays the value or selection for the current parameter. If the "Help" function is enabled, this display will first show the parameter description for 3 seconds (example - page 7). In Operation Mode: Provides an alpha or numeric indentification of the value on the primary display. This display is blank when the Process Value is being shown. In Program & Config. Modes: Provides a 1 digit alpha or numeric character to indicate which parameter value is being shown on the primary display. In Operation Mode: Illuminates when Output 1 and or Output 2 is active. In Program & Config. Modes: No function.

O P E R A T I O N OPERATION MODE CHANGING A PRESET VALUE 34567 Proc Hi H Default display is the process value. Pressing the Program Key will cause the display description to appear on the main display.* If there is no key activity for 3 seconds, the primary display will switch back to the process value. Maximum (High) Value: Displays the maximum process value the unit has received as an input. The value can be reset (only while being displayed) by pressing the Reset Key. AL 1 AL 2 1 2 Alarm 1 Value: Defines the process value at or above which Alarm 1 will activate if set to Process High Alarm in Configuration Mode or the process value at or below which Alarm 1 will be active if set to Process Low Alarm in Configuration Mode. The default value will either be the input range max or min depending on whether Process High or Process Low Alarm was selected. Alarm 2 Value: Defines the process value at or above which Alarm 2 will activate if set to Process High Alarm in Configuration Mode or the process value at or below which Alarm 2 will be active if set to Process Low Alarm in Configuration Mode. The default value will either be the input range max or min depending on whether Process High or Process Low Alarm was selected. Lo L Minimum (Low) Value: Displays the minimum process value the unit has received as an input. The value can be reset (only while being displayed) by pressing the Reset Key. totalt Total: Displays the total value based upon integratation of the input signal using a programmable time base. The value can be reset (only while being displayed) by pressing the Reset Key. EL tie Alarm 1 Elapsed Time: Displays the accumulated amount of time the alarm 1 condition was present. This value will continue to accumulate until it is reset by pressing the Reset Key (while the value is being displayed). The value is displayed in mm:ss up to 99 min 59 secs., then changes over to mmm.m * Parameter descriptions will not appear on the primary display if the "Help" function has been disabled. 5

O P E R A T I O N OPERATION MODE Continued OTHER OPERATING DISPLAYS chhc Over Range Display: Appears if the process value becomes higher than the input full scale value. brea/ Sensor Break Display: Appears if the unit does not receive an input signal for two seconds. cllc Under Range Display: Appears if the process value becomes lower than the input full scale value. CHANGING AN ALARM VALUE 34567 AL 1 5 Times Default display is the the Process Value. From the Process Value display, scroll through the other Operation Mode values until Alarm 1 appears.* 100.001 190.001 Use the Scroll Key to move from left to right and highlight the digit that needs to be changed. Wrap around will occur from the least significant to the most significant digit. Use the Down Key to decrement the digit until the desired value appears. The display will wrap around from 0 to 9. 100.001 To change the Alarm value, press the Scroll Key. If there was no key activity for 3 seconds, the Alarm value will appear (one digit description shown on secondary display); however, press the Scroll Key in order to edit. The unit will now be in Edit Operation as signified by the most significant digit flashing.** 190.00 1 After the desired digits have been changed, press the Program Key to enter the new value. The new value will appear on the main display without any flashing digits. Press the Progam Key again and the parameter description will appear on the main display. * Parameter descriptions will not appear on the primary display if the "Help" function has been disabled. ** Edit Operation cannot be accessed if the Preset Lock has been enabled in Program Mode. 6

P R O G R A M M I N G PROGRAM MODE ENTERING PROGRAM MODE AND BASIC OPERATION The Program Mode can be accessed from the Operation Mode by holding the Program Key for 3 seconds. 34567 The name of the first parameter will appear on the primary display.* for 3 seconds Edit Operation 3 secs. or ScA 1 0.00 1 Successive presses of the Program Key will scroll the display through the remaining parameters in the Program Mode. To exit Program Mode, hold the Program Key for 3 seconds. * Parameter names will not appear on the main display if the "Help" function has been disabled in Program Mode. dis 1 Pressing the Scroll Key or no key activity for 3 seconds will display the value for that parameter. The secondary display will indicate the one digit identifier for the parameter. The digit in the secondary display will flash to indicate the unit is in Program Mode. If the Scroll Key was pressed (instead of waiting 3 seconds), the unit is in Edit Operation, as indicated by the MSD flashing. If there had been no key activity for 3 seconds, press the scroll key to enter Edit Operation (MSD flashing). Use the scroll and edit buttons to change the value as in Operation Mode, described on page 6. Press the Program Key to enter any changes. PARAMETER SEQUENCE ScA 1 1 Scaling Point 1 Function: Sets the first sensor input value point which will be used in establishing a curve for scaling sensor inputs into engineering unit values. Pressing the Reset Key will serve as a teach function and input the sensor value currently being read -19999 to 99999 Default Value: 0.00 dis 1 1. Display Point 1 Function: Provides the engineering unit value that will be displayed corresponding to the sensor input value set in the Scaling Point 1 parameter -19999 to 99999 Default Value: 0.00 7

. P R O G R A M M I N G PROGRAM MODE Continued ScA 2 2 Scaling Point 2 Function: Sets the second sensor input value point which will be used in establishing a curve for scaling sensor inputs into engineering unit values. Pressing the Reset Key will serve as a teach function and input the sensor value currently being read -19999 to 99999 Default Value: 99999 dis 2 2 Display Point 2 Function: Provides the engineering unit value that will be displayed corresponding to the sensor input value set in the Scaling Point 2 parameter -19999 to 99999 Default Value: 100.00 The scaling process can be repeated up to a total of 10 scale and display points. Scale and display points will continue to be offered (up to 10 total) so long as 99999 (the maximum adjustment range) has not been selected as a scaling point. dec P d Decimal Position Function: Sets the position of the decimal point for use in displaying the process and alarm values 0 to 0.000 Default Setting: 0.00 rt Lo L Retransmission Scale Minimum (Appears only if a retransmission output has been enabled in Configuration mode) Function: Defines the lower end of the linear scale for the retransmission output by defining the value equated to the minimum output signal -19999 to 99999 Default Value: 0.00 rt Hi H Retransmission Scale Maximum (Appears only if a retransmission output has been enabled in Configuration mode) Function: Defines the upper end of the linear scale for the retransmission output by defining the value equated to the maximum output signal -19999 to 99999 8 Default Value: 100.00

P R O G R A M M I N G PROGRAM MODE Continued off Filt O F Process Variable Offset Function: Corrects a known offset of the input in order to more accurately display the process value -19999 to 99999 Default Value: 0.00 Input Filter Time Function: Filters the input over a user definable time period to minimize the effect on the Process Value of any extraneous impulses 0.0 (Off) to 100.0 Default Value: 2.0 Addr A Communication Address (Appears only if communication board is installed and activated) Function: Defines the unique communication address of the instrument 1 to 99 Default Value: 1 baud b Baud Rate (Appears only if communication board is installed and activated) Function: Selects the serial communication speed 1200 2400 4800 9600 1200 BPS 2400 BPS 4800 BPS 9600 BPS Default Value: 4800 Color o Display Color Change Function: Defines the color of the display for prior to and after the preset value is reached red GrEEn Gn_rd rd_gn Red: The display will always be red Green: The display will always be green Green to Red: The display will be green when no alarm condition is present. It will turn red when either alarm is active Red to Green: The display will be red when no alarm condition is present. It will turn green when either alarm is active Default Value: Green to Red 9

P R O G R A M M I N G PROGRAM MODE Continued Loc/ / Alarm Lock Function: Determines whether the Alarm Values can be changed via the front panel En Enable: Alarm values can be viewed and changed Default Value: Enable dis Disabled: Alarm values are read only HELP h Help Prompt Function: Determines whether the multi-character parameter name will appear on the main display for 3 seconds prior to the parameter value appearing HLP Y Help - Yes: Multi-character parameter descriptions will appear on the primary display. The value associated with that parameter will appear by pressing the scroll key or waiting for 3 seconds HLP N Help - No: Only the parameter values will appear on the primary display. The parameter can be identified by a single digit in the secondary display Default Value: Help - Yes 10

C O N F I G U R A T I O N CONFIGURATION MODE ENTERING CONFIGURATION MODE AND BASIC OPERATION The Configuration Mode can be accessed from the Operation Mode by holding the Down and Program Keys for 3 seconds. 34567 The name of the first parameter will appear on the primary display.* FrEQ for 3 seconds 3 secs. or Edit Operation 60 F Successive presses of the Program Key will scroll the display through the remaining parameters in the Configuration Mode. To exit Configuration Mode, hold the Down and Program Keys for 3 seconds. * Parameter names will not appear on the main display if the "Help" function has been disabled in Program Mode. AL 1 Pressing the Scroll Key or no key activity for 3 seconds will display the value for that parameter. The secondary display will indicate the one digit identifier for the parameter. The digit in the secondary display will flash to indicate the unit is in Configuration Mode. If the Scroll Key was pressed (instead of waiting 3 seconds), the unit is in Edit Operation, as indicated by the MSD flashing. If there had been no key activity for 3 seconds, press the scroll key to enter Edit Operation (MSD flashing). Use the scroll and edit buttons to change the value as in Operation Mode, described on page 6. Press the Program Key to enter any changes. PARAMETER SEQUENCE FrEQ F Power Supply Frequency Function: Although the instrument is designed to handle either 50 or 60 Hz inputs automatically, to ensure proper filtering of the input signal, it is necessary to set the input frequency of the primary input power Default Value: 60 50 60 50 Hz 60 Hz 11

C O N F I G U R A T I O N CONFIGURATION MODE Continued AL 1 1 Alarm 1 Type Function: Sets the action of the alarm to one of the following choices: P_Hi P_Lo none Process High: Alarm will activate when the process value equals or exceeds the Alarm 1 setting Process Low: Alarm will activate when the process value equals or is less than the Alarm 1 setting No Alarm: Alarm 1 will be activate Default Value: Process High Alarm AL 2 2 Alarm 2 Type Function: Sets the action of the alarm to one of the following choices: P_Hi P_Lo none Process High: Alarm will activate when the process value equals or exceeds the Alarm 2 setting Process Low: Alarm will activate when the process value equals or is less than the Alarm 2 setting No Alarm: Alarm 2 will be activate Default Value: No Alarm Out 1 U Output 1 Usage Function: Determines how the transistor and relay for output 1 will operate A1nd A1nr A1Ld A1Lr Alarm 1, Non latching, Direct Action: The output will be On when Alarm 1 is activate, and turn Off once the Alarm 1 condition is no longer present Alarm 1, Non latching, Reverse Action: The output will be On when Alarm 1 is inactive, and turn Off when the Alarm 1 condition is present Alarm 1, Latching, Direct Action: The output will be On when Alarm 1 is activate, and turn Off only when reset via the front panel Alarm 1, Latching, Reverse Action: The output will be On when Alarm 1 is inactive, and turn Off only when reset via the front panel 12 012d Logical OR of Alarm 1 & 2, Direct Action: The output will be On when a logical OR condition between Alarm 1 and Alarm 2 is present 012r Logical OR of Alarm 1 & 2, Reverse Action: The output will be On when a logical OR condition between Alarm 1and Alarm 2 is not present Default Value: Alarm 1, Non latching, Direct Action

C O N F I G U R A T I O N CONFIGURATION MODE Continued Out 2 u Output 2 Usage Function: Determines how the transistor and relay for output 2 will operate A2_d A2_r 012d 012r Alarm 2, Direct Action: The output will be On when Alarm 2 is activate, and turn Off once the Alarm 2 condition is no longer present Alarm 2, Reverse Action: The output will be On when Alarm 2 is inactive, and turn Off when the Alarm 2 condition is present Logical OR of Alarm 1 & 2, Direct Action: The output will be On when a logical OR condition between Alarm 1 and Alarm 2 is present Logical OR of Alarm 1 & 2, Reverse Action: The output will be On when a logical OR condition between Alarm 1and Alarm 2 is not present Default Value: Alarm 2, Direct Action rt En t Retransmission Output Function: Selects the range of the retransmission output none 0-5u 0-10u 0-20A None 0-5 Volts DC 0-10 Volts DC 0-20 ma 4-20A 4-20 ma Default Value: None OPtn o Option Selection Function: Determines the function of the board installed in the option slot none SctY tare Co<>S No Input Default Value: None Security: When the digital input is active, the Program and Configuration Modes cannot be accessed Tare: When the digital input is activated the currently measured value is zeroed out and will remain as a constant offset Communication: The slot will be used for RS-485 communication 13

C O N F I G U R A T I O N CONFIGURATION MODE Continued PoLJr P Excitation Power Supply Function: Selects the voltage level supplied to the strain gauge S u 10u 5 Volts DC 10 Volts DC Default Value: 5 Volts DC tot t Totalizer Scale Factor Function: Sets the time base used for the totalization calculation. This value should be set the same as the time base used for the engineering units which appear on the display. Ex: If the display is calibrated to display GPM, set the Totalizer scale factor to minutes SEc Seconds <>in Minutes hr Hours Default Value: Seconds 14

A P P E N D I X A SPECIFICATIONS Process Input Range: Accuracy: Sample Rate: Resolution: Sensor Break: 0-100 mvdc + 0.03% of span 100 ms 14 bits Detected within 2 seconds Communication Type: Serial asynchronous, UART to UART Data Format: Open ASCII: One start bit, even parity seven data bits, one stop bit Physical Layer: RS-485 Maximum Zones: 99 Baud Rate: Selectable from 9600, 4800, 2400, or 1200 Control Inputs Type: Sinking, Edge Sensitive Logic: Low < 2.0 VDC, High > 3.0 Impedance: 4.7 KΩ to +Voltage - Sourcing Response Time: 25 ms Function: Programmable Electrical Supply Voltage: 90-264 VAC, 50/60 Hz, or 20-50 VAC/VDC Power Consumption: 4 Watts Access. Power Supply: Selectable 5 or 10 VDC @ 60 ma Outputs Solid State: Relay: Latency: NPN open collector, 30 VDC max, 100 ma max. SPDT, 5A resistive @ 110VAC 75 µ seconds, plus 8 ms for relay pull-in Display Type: Height: Annunciators: Red/Green, 7 segment LED, 5 digits primary display, single digit secondary display 0.71" (18mm) primary display, 0.3" (7mm) secondary display Output 1 & 2 status Linear Outputs Ranges: 0-20mA, 4-20mA, 0-10V, 2-10V, 0-5V, 1-5V Accuracy: ±0.25% (ma at 250Ω, V at 2kΩ); degrades linearly to ±0.5% Resolution: 8 bits in 250ms (10 bits in 1s typ.) Update: Approximately 4/s Load Impedence: ma Ranges: 500Ω max.; V Ranges: 500Ω min. Approvals General: CE EMC Susceptibility: Complies with EN50082-1: 1992, EN50082-2: 1995 EMC Emissions: Complies with EN50081-1: 1992, EN50081-2: 1994 Safety: Complies with EN61010-1: 1993 Physical Dimensions: Mounting: Terminals: Front Panel Rating: Case Material: GE Lexan 940 Weight: 0.56 lbs. Environmental Operating Temp.: Storage Temp.: Relative Humidity: 48mm x 96mm, 110mm deep Panel mount (mounting bracket supplied), 45mm x 92mm cutout Screw type - combination head NEMA 4X/IEC IP65 0 to 55 Celsius, 32 to 131 Fahrenheit -20 to 80 Celsius, -4 to 176 Fahrenheit 20% to 95% non-condensing 15

G E N E R A L ORDERING INFORMATION S628-6 2nd Relay Option 0 None 1 2nd Relay Linear Output Option 0 None 3 Linear Output Serial Communication Option 0 None 5 RS-485 6 Digital Input Low Voltage Power Supply 2 Yes (leave blank if does not apply) WARRANTY Standard products manufactured by the Company are warranted to be free from defects in workmanship and material for a period of one year from the date of shipment, and products which are defective in workmanship or material will be repaired or replaced, at the option of the Company, at no charge to the Buyer. Final determination as to whether a product is actually defective rests with the Company. The obligation of the Company hereunder shall be limited solely to repair and replacement of products that fall within the foregoing limitations, and shall be conditioned upon receipt by the Company of written notice of any alleged defects or deficiency promptly after discovery within the warranty period, and in the case of components or units purchased by the Company, the obligation of the Company shall not exceed the settlement that the Company is able to obtain from the supplier thereof. No products shall be returned to the Company without its prior consent. Products which the Company consents to have returned shall be shipped F.O.B. the Company's factory. The Company cannot assume responsibility or accept invoices for unauthorized repairs to its components, even though defective. The life of the products of the Company depends, to a large extent, upon the type of usage thereof, and THE COMPANY MAKES NO WARRANTY AS TO FITNESS OF ITS PRODUCTS FOR SPECIFIC APPLICATIONS BY THE BUYER NOR AS TO PERIOD OF SERVICE UNLESS THE COMPANY SPECIFICALLY AGREES OTHERWISE IN WRITING AFTER THE PROPOSED USAGE HAS BEEN MADE KNOWN TO IT. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Printed in U.S.A. 702139-0005 August 15, 1998 Revision none Danaher Controls 1675 Delany Road Gurnee, IL 60031 1282 Phone: 847.662.2666 Fax: 847.662.6633 16