OMX-CI-NWK-E Control Interface

Similar documents
OMX-CI-RS232 Control Interface

GRX-CI-NWK-E Control Interface

GRX-CI-RS232 Control Interface

GRX-CI-NWK-E Control Interface

QSE-CI-NWK-E Control Interface

QSE-CI-DMX Control Interface

QSE-CI-DMX Control Interface

LUT-DMX DMX512 Control Interface

GRX-PRG Programming Control Interface

EGRX-2B-SL- - 2-Button Wallstation

QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower

GRAFIK 5000P / 6000P / 7000P Processor Panel

SS-1BI-GWH-E00 1-Button Wallstation

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment

product specifications d

Quantum Light Management Hub (QP3) for Quantum Select

Energi Savr NodeTM Programming Interface

QSWE-2BN- - QSWE-2BI- - 2-Button Wallstation

HomeWorks QS Processor

Wallstations for use with Grafik 3000 and 4000 Series Systems

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

GRX-3000 Control Units

Energi Savr NodeTM for 0 10 V Energi Savr NodeTM with Softswitch

LCP128 Dimming and Switching System

LCP128 Dimming & Switching System

QuantumR Light Management Hub

EcoSystem to 0 10 V- Interface

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Industrial PoE Media Converter

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

HomeWorks QS Processor

HomeWorks Wired Signature Series Keypads

QSWS2-1BN- - QSWS2-1BI- - 1-Button Wallstation

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

GRAFIK Eye 3000 Series Control Unit

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

QuantumR Light Management Hub (QP2)

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Energi Savr Node with DALI for Quantum

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

HomeWorks B & O Keypads. Installation Instructions Please Read Before Installing. Overview. Important Notes

Installation Instructions

HomeWorks Wired seetouch Keypads (Domestic Models)

Hardened PoE Ethernet Switch

HomeWorks QS GRAFIK T QS Slider

HomeWorks QS Wired ArchitraveTM Keypads

H704-42(H)(E), H704-42/1(H)(E)

SCC5-RM. Coloronix, Inc West Jefferson Boulevard Los Angeles, California (323)

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Rev Cutler-Hammer Smart Breaker Panel Control Manual

EA500. Installation Instructions Transponder

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

MOTION NCOORDINATOR MC4N - ECAT Quick Connection Guide

IMPORTANT SAFETY INSTRUCTIONS

FL MC 2000E (SM40) LC

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

High Power over Ethernet Midspans PD Port Model PD Port Model

Zodiac FR100 TM INSTALLATION MANUAL

Product Data Sheet. BMS/Graphics Interface. Features

CONTROL PROTOCOL Motorized Projection Screens

HomeWorksR QS 1-Link Processor

KFC-200. Installation Guide

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Wallstation Installation Guide Please Read Low-Voltage PELV (Class 2: USA)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Solecis 8x1 HDMI Digital Switcher with DXLink Output SDX-810-DX (FG )

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

16-Port Chassis Media Converter System Manual

Solecis 4x1 HDMI Digital Switcher with DXLink Output SDX-410-DX (FG )

Temperature controller Ducted systems

LGate 120 Installation Guide - Appendix

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

GRAFIK Eye QS Wireless Control Unit (230 V Limited 434 MHz) Mechanical Dimensions. Preset Dimming Controls

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Quick Start Guide. Installation. User s Manual 1

10/100Base-TX Industrial Ethernet Extender

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

MIC-2 MKII, Multi-instrument DATA SHEET

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Eco Loop 1. Eco Loop 2. Wallstation.

applications. The TINJ-101-M12 PoE Injector is an advanced IEEE802.3at compliant device with Intelligent Detection that

Solecis 4x1 4K HDMI Digital Switcher with DXLink Output SDX-414-DX (FG )

HomeWorksR QS Dynamic Keypads

Industrial Media Converters

Power Boosters and 120 V Interfaces

Transcription:

Control Interface 369369 Rev. B 1 06.02.11 Description Integrates GRAFIK 5000TM, GRAFIK 6000, GRAFIK 7000TM, Softswitch128, and LCP128 systems with a touchscreen or other digital equipment that supports TCP/IP communication over Ethernet. Provides monitoring commands that allow a touchscreen to query lighting systems to: Determine which scene is selected. Keep track of buttons pressed. Provides control commands that allow a touchscreen or PC to operate lighting systems to: Select or sequence lighting scenes. Raise or Lower one or more zones. Activate panic mode (lights go to full on). Simulate button actions Disable or Enable timeclock(s)

Specifications 369369 Rev. B 2 06.02.11 Power IEC PELV/NEC Class 2 Operating Voltage: 12 V 125 ma 24 V 65 ma Uses OMX RS232 Command Set Monitoring: Scene selection and scene status updates. Control: Scene selection, scene lockout, sequencing, zone lockout, zone raise/lower. System Communications and Capacity IEC PELV/NEC Class 2 wiring connects Interface to Processor Panel. Standard CAT5 cable, 328 ft (100 m) maximum, connects Interface to PC or other Ethernet source. Supports MDI/MDIX auto-crossover (no crossover cable needed). Multiple may be used in a single system. Environment 32 to 104 F (0 to 40 C). Relative humidity less than 90% non-condensing. Dip 1 2 3 4 9 10 11 12 17 18 19 20 25 26 27 28 5 13 21 29 6 14 1 2 3 4 5 6 22 1 2 3 4 5 6 30 7 15 23 31 8 16 24 7 8 32 ing Up Down (On) (Off) Not used

369369 Rev. B 3 06.02.11 Dimensions 2.47 in (62.7 mm) Mounting Holes 3.75 in (95.3 mm) 4.26 in (108.2 mm) 5.26 in (133.6 mm) 1.06 in (26.9 mm) Mounting 1. Mount the control interface directly on a wall, as shown in the Mounting Diagram, using screws (not included). When mounting, provide sufficient space for connecting cables. The unit can also be placed in the LUT-19AV-1U AV rack using the screws provided with the unit. The LUT-19AV-1U will hold up to four units. If conduit is desired for wiring, the LUT-5x10-ENC can be used to mount one unit. 2. Strip 4 in (10 mm) of insulation from wires. Each data link terminal will accept up to two 18 AWG (1.0 mm 2 ) wires. 3. Connect wiring as shown in the Wiring Diagram (next page). LED 1 lights continuously (Power) and LED 7 blinks rapidly (Data Link RX) when the IEC PELV/NEC Class 2 Data Link is installed correctly. Mounting Diagram Control Interface Wall Mounting Hole Detail Dimensions: in (mm) 0.25 (6.4) #6 or #8 (M3 or M4) screw recommended (not included) Wire Strip Length 4 in (10 mm) 0.18 (4.6) 0.34 (8.6) 0.18 (4.6) LUT-5x10-ENC LUT-19AV-1U

Ethernet Link Wiring 369369 Rev. B 4 06.02.11 Standard CAT5 cable connects Interface to PC, router, or other Ethernet source. No crossover cable needed. Must be 328 ft (100 m) or less. Ethernet network and cable provided by others. IEC PELV/NEC Class 2 Wiring Daisy-chain the Interface to the IEC PELV/NEC Class 2 Wallstation Link that connects to the Processor Panel. Make daisy-chain connections to the IEC PELV/NEC Class 2 Data Link terminals on the front of Interface. Do not use T-taps. Run all wires in and out of terminal block. Each terminal accepts up to two 18 AWG (1.0 mm 2 ) wires. LED 1 lights when the IEC PELV/NEC Class 2 Data link is installed correctly. Consult Processor Panel Specification Submittal for more details. Ethernet link/ activity CAT5 Cable: maximum 328 ft (100 m) Ethernet speed To PC or AV Equipment. For Ethernet Link, use CAT5 cable provided to connect to auxiliary equipment. The Ethernet Link LED will light continuously when link is present and will flash when there is link activity. Additional Ethernet network equipment and cables provided by others. 7 RJ45 jack: Ethernet Link (to PC or A/V equipment) Data Link (to Control Units, processors, and wallstations) DIP Switches 12 or 24 V to outlet (with optional transformer). Do not wire terminal 2 on Data Link when using optional transformer. To power separately from the Data Link, order the following Lutron transformer model numbers: 120 V : T120-15DC-9-BL 240 V : TE240-15DC-9-BL 240 V (UK): TU240-15DC-9-BL LED 1: Power LED 2: Ethernet link LED 3, 4, 5: Unused LED 6: Data link TX LED 7: Data link RX

IEC PELV/NEC Class 2 Terminal Connections 369369 Rev. B 5 06.02.11 Two 12 AWG (2.5 mm 2 ) conductors for common (terminal 1) and 24 V (terminal 2). These will not fit in terminals. Connect as shown. Ensure that the terminal 2 connection is wired when not using optional transformer. One shielded, twisted pair 18 AWG (1.0 mm 2 ) for data link (terminals 3 and 4). Connect Drain/Shield as shown. Do not connect to Ground (Earth) or Wallstation/Control Interfaces. Connect the bare drain wires and cut off the outside shield. Data Link: (1) shielded, twisted pair 18 AWG (1.0 mm 2 ) 4: MUX 3: MUX Use Lutron Cable GRX-CBL-46L 4 3 2 1 D: Drain/Shield (2) 12 AWG (2.5 mm 2 ) Note: Do not connect Drain/Shield to Ground (Earth) or Wallstation/Control Interfaces. Connect the bare drain wires and cut off the outside shield. IEC PELV/NEC Class 2 Power wiring: 1: Common 2: 24 V Power (2) 18 AWG (1.0 mm 2 ) pigtails, 6 in (152 mm) maximum length (2) 12 AWG (2.5 mm 2 ) Note: 12 AWG (2.5 mm 2 ) conductors for Common (terminal 1) and 24 V Power (terminal 2) will not fit in terminals; use 18 AWG (1.0 mm 2 ) pigtails (< 6 in/152 mm).