This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Similar documents
Type VRLTC tap changer

Central Power Research Institute, Medipally PO, Uppal, Hyderabad, Telangana. Discipline Electrical Testing Issue Date

Relion 611 series. 611 series Type Test Certificate

CompactBlock Guard I/O EtherNet/IP Safety Modules

Universal Power Supplies

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Features. Applications and Benefits TRC ELECTRONICS, INC

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Gelo LED Driver 100W, Single output RGLD100-24

Autodaptive Capacitor Control M 2501B

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

RT12-240V/2.4kW Rectifier Specification

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Arc protection relay. Features Three-phase overcurrent function. Application

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

FL MC 2000E (SM40) LC

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Safety Standards. Model Number:

Contact protection relay

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

TU531, TU532 Terminal Unit

Output Voltage* (nom.)(adjustable)

Safety Standards. Model Number: Unit Weight:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Scout-S Station Controller

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

InteliPro. Protection Relay for Parallel Applications. Technical Specification

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

MINER-S Station Controller

AO523 Analog Input Module

IEC/EN/UL60950 & CE certified, EN55032 Class B

Safety Standards. Model Number:

SAMSUNG ELECTRO-MECHANICS CO., LTD

Safety Standards. Model Number:

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Safety Standards. Model Number:

Safety Standards. Model Number:

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Thermistor motor protection relay CM-MSS.11

Universal input VAC <150mW No load power consumption

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Thermistor motor protection relay CM-MSS.21

Safety Standards. Model Number:

National Standard of The People s Republic of China

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

EH-RIO IP67 Profibus-DP I/O modules

Enclosed Power Supplies

ControlNet-to-DeviceNet Linking Device

RT4B-110V/12A RECTIFIER

TF501, TF521 Terminal Bases

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

RT7-48V/6kW Specification

Power supply CP-E 24/10.0 Primary switch mode power supply

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

CD522 Encoder, Counter and PWM Module

Power supply CP-E 48/1.25 Primary switch mode power supply

RT4F-48V/50A-WAC RECTIFIER

PJ Open Frame Power Supply 24V 50W 1 Phase / PJ-24V50W NA

Solid-State Contactors

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Switching relay CT-IRE with 1 c/o (SPDT) contact

Communication Gateway COM 610. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide

RT4F-120V/20A-WAC RECTIFIER

Power supply CP-E 24/0.75 Primary switch mode power supply

Feeder protection relay SPAA 121 C. Product Guide

MINI-PS AC/10-15DC/8

C B. Models. Operating up to 5000m altitude 5 year product warranty

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Safety Standards. Model Number:

ArmorPoint I/O Field Potential Distributor, Series A

DC532-XC, digital input/output module,

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

RT4F-110V/25A RECTIFIER

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

030AAC Highlights & Features

Output Voltage* (nom.)(adjustable)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

LPS. ME20 20W Single Output External Power Medical Series. Features

Safety Standards. Model Number:

RT9-48V/1.4kW Rectifier Specification

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

PDD-300 pulsed diode driver

Transcription:

Location(s) where activities are performed under accreditation Head Office Utrechtseweg 310, Building no. R11 6812 AR Arnhem The Netherlands Location Abbreviation/ location code Utrechtseweg 310, Building no. R11 6812 AR Arnhem The Netherlands Type activity 1 1 Coils and / or windings rotating electrical machines IEC 60034 1 If there is a referral to a code starting with NAW, NAP, EA IAF, this constitutes a scheme for which RvA-BR010 applies. The accepted version is mentioned on the list schemes for which accreditation can be granted by the RvA. This annex has been approved by the Board the Dutch Accreditation Council, on its behalf, J.A.W.M. de Haas Director Operations Dutch Accreditation Council RvA Page 1 9

Type activity 1 2 Power transformers Power measurement Sound level measurement SFRA measurement Verification voltage ratio and phase displacement Low ambient test on dry-type transformer Thermal shock test on dry type transformer Condensation test on dry-type transformer Humidity penetration test on dry-type transformer Inspection the active part IEC 60076-1, -2, -3, -10, -11, -13, -15, -16, -18 CISPR 18.2 EN 50541-1 IEEE Std. C57.12.00 IEEE Std. C57.12.90 IEEE Std. C57.12.91 3 AC Metal-enclosed switchgear and controlgear above 1 kv and 52 kv and prefabricated substations Verification degree protection IEC 62271-200 IEC 62271-202 IEEE C37.20.2 IEEE C37.21 ANSI C37.54 ANSI C37.55 IEC 60529 4 AC Solid Insulationenclosed switchgear and controlgear above 1 kv and 52 kv Verification degree protection IEC 62271-201 IEC 60529 Dutch Accreditation Council RvA Page 2 9

Type activity 1 5 Gas-insulated metal-enclosed switchgear for rated voltages above 52 kv IEC 62271-203 IEEE Std C37.122 6 High-voltage AC circuit breakers IEC 62271-100 IEEE Std C37.09 IEEE Std C37.013 EN 50152-1 7 High-voltage AC disconnectors and earthing switches IEC 62271-102 IEEE Std C37.34 IEEE Std C37.41 8 High-voltage AC switches Verification degree protection IEC 62271-103 IEC 62271-104 IEEE Std C37.74 9 High-voltage AC contactors Verification degree protection IEC 62271-106 Dutch Accreditation Council RvA Page 3 9

Type activity 1 10 Automatic circuit reclosers and fault interrupters Verification degree protection IEC 62271-111/ IEEE Std C37.60 11 Busducts Verification degree protection IEEE Std C37.23 12 High-voltage AC switch-fuse combinations and high-voltage AC fuses Verification degree protection IEC 62271-105 IEEE Std C37.41 IEEE Std C37.74 IEC 60282-1 IEC 60282-2 13 Insulators and insulated bushings Thermal-mechanical performance test Electro-mechanical failing load test Pollution tests Visible corona test Steep front wave flashover test Porosity test Visual and dimensional test Galvanizing test Thermal shock test Thermal cycle test Water absorption test Impact test Test housing: tracking and erosion tests IEC 60137 IEEE Std C57.19.00 IEEE Std C57.19.01 IEC 60168 IEC 60383 IEC 60507 IEC 60660 IEC 61109 IEC 62217 IEC 62730 ANSI C29.1, -6, -7, -12 ANSI/NEMA C29.2, -13 CAN/CSA C411.1 Dutch Accreditation Council RvA Page 4 9

Type activity 1 14 Cables DC voltage test Lightning impulse test Heat cycle voltage test Insulation resistance measurement Condition test XLPE cable Water penetration test Bending test 15 Cable accessories DC voltage test Heat cycle voltage test Insulation resistance measurement Pollution tests Water penetration test Impact test IEC 60055 IEC 60141 IEC 60502 IEC 60840 IEC 62067 HD 620 HD 632 NEN 3619 BS 6622 BS 7835 BS 7870 BS 7912 BS 7970 IEC 60502-4 IEC 60055 IEC 60840 IEC 62067 HD 629-1 HD 629-2 HD 632 IEEE Std 48 IEEE Std 404 16 Current transformers Accuracy test Inspection active part IEC 60044-8 IEC 61869-2 IEC 61869-1 Dutch Accreditation Council RvA Page 5 9

Type activity 1 17 Voltage transformers Accuracy test Leakage test Inspection active part IEC 61869-1 IEC 61869-3 IEC 61869-5 IEC 60044-7 18 Capacitors Thermal stability test Short-circuit discharge test Endurance test Sealing test Self-healing test Destruction test Ageing test 19 Surge arresters Current impulse test Pollution tests Ageing test 20 Reactors Impedance measurement AC resistance measurement Power measurement Acoustic sound level measurement Verification voltage ratio and phase displacement check IEC 60358 IEC 60831 IEC 60871 IEC 60099 IEEE Std C62.11 IEC 60076-6 IEEE Std C57.21 Dutch Accreditation Council RvA Page 6 9

Type activity 1 21 Compression and mechanical connectors Mechanical tests IEC 61238-1 22 Protection relays & substation automation equipment Functional requirements IEC 60255-1 IEC 60255-149 IEC 60255-12 IEC 60255-13 IEC 60255-121 IEC 60255-127 IEC 60255-151 IEEE C37.112 Product safety requirements IEC 60255-1 IEC 60255-27 EMC requirements 1) IEC 60255-1 IEEE C37.90 Energizing quantities IEC 60255-1 Climatic environmental tests IEC 60255-1 IEC 60068-2-2 tests Bd, Bb IEC 60068-2-1 tests Ad, Ab IEC 60068-2-14 test Nb IEC 60068-2-78 test Cab IEC 60068-2-30 test Db Mechanical environmental tests IEC 60255-1 IEC 60255-21 series 23 Electrical Energy Meters Metrological Characteristics and Functionalities Accuracy Tests for disturbances long duration Tests for electrical requirements Insulation tests EMC requirements1) Overload test Climate tests Mechanical tests In accordance with Directive 2014/32/EU annex I, annex III MI-003 IEC 62052-11, IEC 62053-11/21/22/23 and EN 50470-1/2/3 Remark in accordance with is applicable for all standards. 1) The EMC tests needed for this scheme that are covered by the accreditation are specified below. Dutch Accreditation Council RvA Page 7 9

This part the scope contains the new approach for the specification EMC tests based on a source scope. The tests needed for the above mentioned schemes 22) and 23) are specified below. Type activity 2 Internal reference number Location EMC.I EMC Immunity tests EMC.I.21 As specified in the scheme 22 and 23 Electrostatic discharge immunity (ESD) Contact discharge up to 30 kv Air discharge up to 30 kv IEC 62052-11 EN 50470-1 IEEE C37.90.3 IEC 61000-4-2 EMC.I.22 Electrical fast transient / burst immunity (EFT) 1 and 3 phase 0,25 4 kv up to 1 MHz IEC 62052-11 EN 501470-1 IEEE C37.90.1 IEC 61000-4-4 EMC.I.23 Surge immunity 1 and 3 phase 0,25 8 kv IEC 62052-11 EN 50470-1 IEC 61000-4-5 EMC.I.07 Immunity to conducted disturbances, induced by radio-frequency fields 150 khz 80 MHz 3 V, 10 V IEC 62052-11 IEC 61000-4-6 EMC.I.09 Power frequency magnetic field immunity, 50/60 Hz up to 100 A/m (continuous) up to 1000 A/m (3 s) EN 50470-1 IEC 61000-4-8 EMC.I.26 AC Voltage dips, short interruptions immunity 1 and 3 phase Dips; up to 280 Vac/16 A, 50/60 Hz Variations; up to 280 Vac/5 A, 50/60 Hz EN 50470-1 IEC 61000-4-11 2 If there is a referral to a code starting with NAW, NAP, EA IAF, this constitutes a scheme for which RvA-BR012 applies. The accepted version is mentioned on the list schemes for which accreditation can be granted by the RvA. Dutch Accreditation Council RvA Page 8 9

Type activity 2 Internal reference number Location EMC.I.06 As specified in the scheme 22 and 23 Immunity to conducted common mode disturbances, DC, 16 2/3, 50 and 60 Hz 1 30 V (continues) 10 300 V (short duration) IEC 61000-4-16 15 Hz to 150 Hz 0,1 30 V EMC.I.30 DC voltage ripple Immunity 0 20%, 100/120 Hz 0 300 Vdc IEC 61000-4-17 EMC.I.33 Damped oscillatory wave 100 khz, 1 MHz; 0,25 2,5 kv 3 MHz, 10 MHz, 30 MHz; 0,5 kv 4,0 kv IEEE C37.90.1 IEC 61000-4-18 EMC.I.30 DC Voltage dips, short interruptions, and voltage variations immunity 20 300 Vdc Up to 10 A IEC 61000-4-29 EMC.I.25 Pulsed magnetic field immunity 100 1000 A/m IEC 61000-4-9 EMC.I.33 Damped oscillatory magnetic field immunity 10 100 A/m (100 khz) 10 100 A/m (1 MHz) IEC 61000-4-10 Dutch Accreditation Council RvA Page 9 9