USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

Similar documents
10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

24-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Electromagnetic Compatibility Guidelines

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI R Series. Contents. Software CALIBRATION PROCEDURE

Foundation Fieldbus Hardware and NI-FBUS Software

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

NI PXI-5650/5651/5652

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI PXIe-4080/4081/4082

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

GETTING STARTED GUIDE

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

NI WSN-9791 Ethernet Gateway

Bracket and Mounting Dimensions

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

Electromagnetic Compatibility Guidelines

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

6 GHz Reconfigurable RF Vector Signal Transceiver with 200 MHz Bandwidth

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

NI CMS-9068 and NI MMS-9068

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

NI ELVIS RIO Control Module

NI PXI Contents GETTING STARTED GUIDE

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

System Overview and Terms

NI PXIe-6544/6545/6547/6548

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

LabVIEW DataFinder Toolkit

NI PCIe Hardware Overview. Functional Overview USER MANUAL. Base, Medium, Full, and Extended Configuration Camera Link Frame Grabber

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

LabVIEW FPGA Module Version 2013

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

SH Cable Specifications

NOTE TO USERS NI 65xx Pinout Labels for the SCB-100 Digital I/O Modules/Devices Using the 100-Pin Shielded Connector Block

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

Electrical. SPECIFICATIONS SH Cable

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Thermal Kit for NI sbrio-9607/9627/9637

Introduction... 1 System Diagram... 2 Hardware... 2 Powering the Hardware... 3 Wiring Harness... 5

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

INSTALLATION INSTRUCTIONS Data Management Software Suite

Single-Channel Precision System Source Measure Unit (SMU)

NI PXIe Contents GETTING STARTED GUIDE. 6 GHz T/R Two-Port Vector Network Analyzer

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

This document includes instructions for installing and configuring your NI PXIe-8880 embedded controller.

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

Where to Start with NI ELVIS

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

Transcription:

GETTING STARTED GUIDE USRP-2974 USRP Software Defined Radio Stand-Alone Device This document explains how to install, configure, and test the USRP-2974 Software Defined Radio Stand-Alone Device. The USRP-2974 can send and/or receive signals for use in various communications applications. The device ships with the NI-USRP instrument driver, which you can use to program the device. Contents Verifying the System Requirements...1 Unpacking the Kit... 2 Verifying the Kit Contents... 2 Preparing the Environment... 3 Installing the Software... 3 Connecting to a Computer... 3 Powering on the Device... 4 Programming the Device... 4 NI-USRP Instrument Driver... 4 NI-USRP Sample Projects... 5 Using Your Device with LabVIEW Communications System Design Suite...5 Troubleshooting... 6 Device Troubleshooting... 6 Network Troubleshooting... 7 Front Panel, Back Panel, and Connectors... 9 Direct Connections to the USRP-2974... 9 USRP-2974 Front Panel, Back Panel, and LEDs...10 Where to Go Next... 16 Worldwide Support and Services... 16 Verifying the System Requirements To use the NI-USRP instrument driver, your system must meet certain requirements. Refer to the product readme, which is available on the driver software media or online at ni.com/manuals, for more information about minimum system requirements, recommended system, and supported application development environments (ADEs).

NI USRP-2974 10 MHz 6 GHz, GPS-Disciplined Clock (160 MHz BW) RF 0 RF 1 AUX I/O 3.3 VDC MAX 1G/10G ETH SFP+ Ports Unpacking the Kit Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the device from the package and inspect the device for loose components or any other sign of damage. Notice Never touch the exposed pins of connectors. Note Do not install a device if it appears damaged in any way. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. Verifying the Kit Contents Figure 1. Kit Contents 1 2 3 4 5 1. USRP-2974 2. Getting Started Guide (This Document) 3. 30 db SMA Attenuator 4. SMA (m)-to-sma (m) Cable 5. Power Supply Notice If you directly connect or cable a signal generator to your device, or if you connect multiple devices together, you must connect a 30 db attenuator to the RF input (RX1 or RX2) of each receiving USRP-2974. 2 ni.com USRP-2974 Getting Started Guide

Optional Items Additional SMA (m)-to-sma (m) cables to use the REF IN and PPS IN signals 1 G or 10 G Ethernet cable CDA-2990 Clock Distribution Device for synchronizing multiple devices GPS antenna 10 G Ethernet card for desktop Tip Ettus 10 Gigabit Ethernet Card for Desktop, available at www.ettus.com Preparing the Environment Ensure that the environment you are using the USRP-2974 in meets the following specifications. Operating temperature range 0 C to 50 C Operating humidity Pollution Degree 2 Maximum altitude Indoor use only. 10% to 90% relative humidity, noncondensing 2,000 m Installing the Software You must install LabVIEW Communications System Design Suite before installing NI-USRP software. 1. Visit ni.com/info and enter the Info Code usrpdriver to access the driver download page for the latest NI-USRP software. 2. Download the NI-USRP driver software. 3. Follow the instructions in the installation prompts. Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 4. When the installer completes, select Shut Down in the dialog box that prompts you to restart, shut down, or restart later. Connecting to a Computer For most applications, the USRP-2974 must be connected either to a desktop computer or a laptop computer. Install any software you plan to use on the desktop computer or laptop computer before you connect the hardware. USRP-2974 Getting Started Guide National Instruments 3

1. (Optional) Connect any additional attachments required for your project to the front panel or back panel terminals of the USRP-2974. 2. Connect the USRP-2974 to an Ethernet port on the local subnet or directly to the computer using an Ethernet cable. Connection Action 1G ETH 10G ETH Connect the RJ45 connector of the USRP-2974 front panel to the Ethernet port of the computer. Connect the SFP+ Port 0 connector of the USRP-2974 front panel to the Ethernet port of the computer. Note The USRP-2974 automatically attempts to connect to the network using dynamic host configuration protocol (DHCP). If DHCP is not available, the USRP-2974 connects to the network with a link-local IP address with the form 169.254.x.x. Tip Use an Ethernet router to connect multiple USRP-2974 devices to the computer. Related Information How Do I Change My IP Address Using My Computer? on page 8 Powering on the Device 1. Connect the power supply to the USRP-2974. 2. Plug the power supply into a wall outlet. Press the power button. 3. Power on the computer or laptop. Programming the Device You can use the NI-USRP instrument driver to create communications applications for the USRP-2974. The USRP-2974 contains a controller that runs NI Linux Real-Time. It also contains a LabVIEW FPGA target, which supports the creation of custom FPGAs and configuration of the device using Instrument Design Libraries (IDLs). NI-USRP Instrument Driver The NI-USRP instrument driver features a set of functions and properties that exercise the capabilities of the USRP-2974, including configuration, control, and other device-specific functions. Refer to the LabVIEW Communications System Design Suite Manual for information about using the instrument driver in your applications. 4 ni.com USRP-2974 Getting Started Guide

Software Options You must use the USRP RIO IDL when programming the USRP-2974. Note The NI-USRP API is not supported when programming the USRP-2974. Description: Allows you to interface with the FPGA of your USRP-2974 for advanced programming and digital signal processing (DSP). Uses the USRP RIO Sample Projects, which allow you to take common measurements with your device. USRP RIO Sample Projects are included in the installation. Use Case: Use with LabVIEW Communications System Design Suite to customize the behavior of the device FPGA to create application-specific instrument designs. Location: On the Diagram tab, select Hardware Interfaces»USRP RIO from the palette. NI-USRP Sample Projects The NI-USRP software contains sample projects that are a starting point for application development. Sample projects are only available with the USRP RIO IDL software option. Open the projects in LabVIEW NXG or LabVIEW Communications System Design Suite by selecting the Projects tab and choosing an applicable sample project for your device and setup. Using Your Device with LabVIEW Communications System Design Suite Registering the Device You must register your USRP-2974 with LabVIEW Communications System Design Suite before you can use it to run code. 1. Open LabVIEW Communications System Design Suite and select the Hardware tab. 2. Select Network Systems to display USRP-2974 devices that you can reserve to use in projects on the computer. The device and the computer must be connected to the same local network. 3. In the Unregistered Systems category, select the icon of the USRP-2974 you want to register. 4. Click Register. Note If your USRP-2974 does not appear in the Unregistered Systems category, type the IP address or hostname in the Register by IP or Hostname field. 5. Add or verify the Hostname or IP Address, User name, and Password. By default, the user name is root, and the password is blank. USRP-2974 Getting Started Guide National Instruments 5

6. Click Register. Related Information What is the IP Address of My Device? on page 7 Adding Your Device to a Project Register your device with LabVIEW Communications System Design Suite before adding it to a project. 1. In LabVIEW Communications System Design Suite, create a new project or open an existing or sample project. 2. In the SystemDesigner palette, navigate to Software Defined Radio»USRP RIO»NI USRP-2974. 3. Select the USRP-2974 target and place it on the diagram. 4. In the Configuration pane, select NI USRP-2974 from the Mapped To dropdown menu. Note If there is an external USRP RIO device connected to the PCIe x4 port of the USRP-2974 back panel, you must repeat steps 2 through 4 to map to the corresponding USRP RIO device in the Configuration pane. Verifying the Device Connection Run Tx and Rx Streaming (Host).gvi to confirm that the device transmits and receives signals and is connected correctly to the host computer. 1. In LabVIEW Communications System Design Suite, navigate to Projects. 2. Select USRP-2974 Single-Device Streaming. Click Create. 3. Map to the registered USRP-2974 device to the project as described in Adding Your Device to a Project. 4. Run Tx and Rx Streaming (Host).gvi. If the device is transmitting and receiving signals, the front panel graphs display waveform data. 5. Click STOP to conclude the test. Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. Device Troubleshooting Should I Update Device Firmware and FPGA Images? Your device ships with firmware and FPGA images compatible with the NI-USRP driver software. You may need to update the device for compatibility with the latest version of the software. 6 ni.com USRP-2974 Getting Started Guide

Why Doesn't the Device Power On? Verify that the power supply is functional by substituting a different adapter. Network Troubleshooting Why Doesn't the Device Respond to a Ping (ICMP Echo Request)? The device should reply to an internet control message protocol (ICMP) echo request. To ping the device, open a Windows command prompt and enter ping <IP address>, where <IP address> is the IP address for your USRP device. If you do not receive a response, verify that the host network interface card is set to a static IP address corresponding to the same subnet as the IP address of the corresponding device. Also verify that the device IP address is set properly. Why Doesn't LabVIEW Communications System Design Suite Detect the USRP-2974? Ensure that the device is powered on and has a valid IP address. Refer to the NI-USRP Readme to verify that your version of the NI-USRP instrument driver supports the USRP-2974. What is the IP Address of My Device? The device acquires an IP address when connected to the network for the first time. You can discover this IP address by using Linux commands while connected to the device. 1. Connect the USRP-2974 to a monitor, keyboard, and mouse. 2. Enter your login credentials. 3. Use the Linux command ifconfig to view the IP address for the following Ethernet ports: Table 1. Ethernet Port Addressing Ethernet Port Addressing Port Description eth0 eth1 1G ETH RJ45 Internal 10G ETH eth2 External SFP+ 1G/10G ETH 0 Note The external SFP+ 1G/10G ETH 1 port does not have access to the system on module (SoM). Tip You can limit the results by adding the Ethernet port after the Linux command ifconfig. For example, the Linux command ifconfig eth0 provides the IP address for the 1G ETH RJ45 port. USRP-2974 Getting Started Guide National Instruments 7

How Do I Change My IP Address Using My Computer? 1. Open or create a project including the USRP-2974 as described in Adding Your Device to a Project. Note If the device cannot be connected in SystemDesigner due to an incorrect or unknown IP address, set up a temporary IP address for the device as described in How Do I Change My IP Address without Using My Computer?. 2. Select Network Adapters on the target in SystemDesigner. 3. Select Configure Network Settings on the Configuration pane. 4. Select the network adapter that you want to change the settings for using the addresses defined in the following table. Ethernet Port Addressing Table 2. Ethernet Port Addressing Port Description eth0 eth1 1G ETH RJ45 Internal 10G ETH eth2 External SFP+ 1G/10G ETH 0 5. Set the mode. 6. Set the address if the mode is static. 7. Click Apply. Note The external SFP+ 1G/10G ETH 1 port does not have access to the system on module (SoM). How Do I Change My IP Address without Using My Computer? 1. Connect the USRP-2974 to a monitor, keyboard, and mouse. 2. Enter your login credentials. 3. Use the Linux command ifconfig <Port> <IP Address>, where <Port> is one of the following Ethernet ports, and <IP Address> is the new IP address. 8 ni.com USRP-2974 Getting Started Guide

Ethernet Port Addressing Table 3. Ethernet Port Addressing Port Description eth0 eth1 1G ETH RJ45 Internal 10G ETH eth2 External SFP+ 1G/10G ETH 0 Note The external SFP+ 1G/10G ETH 1 port does not have access to the system on module (SoM). For example, if you would like to change the IP address of the 1G ETH RJ45 port, use the Linux command ifconfig eth0 <IP Address>. Notice This change is lost once the device is turned off. Once the device is accessible from your computer, change the IP address using your computer as described in How Do I Change My IP Address Using My Computer? to ensure the IP address is set indefinitely. Why Does the Device Not Connect to the Host Interface? Ensure the connection between the host network interface card and the device cable connection is valid and both the device and computer are powered on. A lit green LED in the upper left corner of the gigabit Ethernet connection port on the device front panel indicates a gigabit Ethernet connection. Front Panel, Back Panel, and Connectors Direct Connections to the USRP-2974 The USRP-2974 is an RF instrument that is sensitive to ESD and transients. Ensure you take the following precautions when making direct connections to the USRP-2974 to avoid damaging the device. Notice Apply external signals only while the USRP-2974 is powered on. Applying external signals while the device is powered off may cause damage. Ensure you are properly grounded when manipulating cables or antennas connected to the USRP-2974 TX 1 RX 1 or RX 2 connector. If you are using nonisolated devices, such as a nonisolated RF antenna, ensure the devices are maintained in a static-free environment. If you are using an active device, such as a preamplifier or switch routed to the USRP-2974 TX 1 RX 1 or RX 2 connector, ensure that the device cannot generate signal transients greater than the RF and DC specifications of the USRP-2974 TX 1 RX 1 or RX 2 connector. USRP-2974 Getting Started Guide National Instruments 9

ACT/ LINK 10GbE ACT/ LINK 10GbE USRP-2974 Front Panel, Back Panel, and LEDs Front Panel RF 0 NI USRP-2974 10 MHz 6 GHz, GPS-Disciplined Clock (160 MHz BW) AUX I/O 3.3 VDC MAX RF 1 TX1 RX1 RX2 REF PPS GPS TX1 RX1 RX2 TX OUTPUT MAX +20 dbm, RX INPUT MAX -15 dbm, ALL RF PORTS 50 Ω RESET STATUS PWR USER 2 USER 1 10/100/ 1000 ACT/ LINK 1 0 1G/10G ETH SFP+ Ports Table 4. Connector Descriptions Connector Use RF 0 TX1 RX1 Input and output terminal for the RF signal. TX1 RX1 is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input or output channel. AUX I/O RX2 Input terminal for the RF signal. RX2 is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input channel. General-purpose I/O (GPIO) port. AUX I/O is controlled by the FPGA. RF 1 TX1 RX1 Input and output terminal for the RF signal. TX1 RX1 is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input or output channel. RX2 Input terminal for the RF signal. RX2 is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input channel. DP USB2.0 USB3.0 1G ETH μusb DisplayPort connector to connect one monitor for your controller. USB ports that support common USB peripheral devices such as flash drives, hard drives, keyboards, and mice. USB ports that support common USB peripheral devices such as flash drives, hard drives, keyboards, and mice. RJ45 port used for 1G ETH connectivity to other ethernet devices. USB port used for UART connectivity to the controller. 10 ni.com USRP-2974 Getting Started Guide

Table 4. Connector Descriptions (Continued) Connector 1G/10G ETH 0 1G/10G ETH 1 Use SFP+ port used for 10G ETH connectivity to other ethernet devices. Connects to the embedded Linux computer for communication with LabVIEW RT. SFP+ port used for 1G/10G ETH connectivity to other ethernet devices. Connects to the FPGA. Not currently supported in LabVIEW Communications System Design Suite. Table 5. LEDs LED Description Color State Indication RF 0 TX1 RX1 Indicates the transmit status of the device. OFF The device is not active. Red Solid The device is transmitting data. Green Solid The device is receiving data. RX2 Indicates the receive status of the device. OFF The device is not receiving data. Green Solid The device is receiving data. REF Indicates the status of the reference signal. OFF There is no reference signal, or the device is not locked to the reference signal. Green Blinking The device is not locked to the reference signal. Solid The device is locked to the reference signal. USRP-2974 Getting Started Guide National Instruments 11

Table 5. LEDs (Continued) LED Description Color State Indication PPS Indicates the pulse per second (PPS). OFF There is no PPS timing reference signal, or the device is not locked to the reference signal. Green Blinking The device is locked to the PPS timing reference signal. GPS Indicates whether the GPSDO is locked. OFF There is no GPSDO or the GPSDO is not locked. Green Solid The GPSDO is locked. RF 1 TX1 RX1 Indicates the transmit status of the device. OFF The device is not active. Red Solid The device is transmitting data. Green Solid The device is receiving data. RX2 Indicates the receive status of the device. OFF The device is not receiving data. Green Solid The device is receiving data. 12 ni.com USRP-2974 Getting Started Guide

Table 5. LEDs (Continued) LED Description Color State Indication STATUS Indicates the status of the device. OFF The device initialized successfully and is ready for use. Red Blinking Hardware error. An internal power supply has failed. Check front-panel I/O connections for shorts. Remove any shorts and cycle power to the USRP-2974. Contact NI if the problem persists. PWR Indicates the power status of the device. OFF The device is powered off. Green Solid The device is powered on. 10/100/1000 Indicates the speed of the Gigabit Ethernet link. OFF No link, or 10 Mbps link. Green Solid 100 Mbps link. Amber Solid 1,000 Mbps link. ACT/LINK Indicates the Gigabit Ethernet link activity or status. OFF No link has been established. Green Solid A link has been negotiated. Blinking Activity on the link. USRP-2974 Getting Started Guide National Instruments 13

Table 5. LEDs (Continued) LED Description Color State Indication 1G/10G ETH 0 ACT/ LINK 10GbE 1G/10G ETH 1 10GbE Indicates the status of the SFP+ port. Indicates the status of the 10G ETH link. Indicates the status of the 10G ETH link. OFF The link is down. Green Solid The link is up. Blinking The link is active (transmitting and receiving). OFF The 10G ETH link is down. Green Solid The 10G ETH link is up. OFF The 10G ETH link is down. Green Solid The 10G ETH link is up. Back Panel REF OUT 3.3 V REF IN +15 dbm MAX PPS TRIG OUT 3.3 V PPS TRIG IN 5 V MAX GPS ANT -15 dbm MAX 5 V PCIe x4 Vin Vin GND GND SYSTEM POWER IN 13 16V 150W MAX 14 ni.com USRP-2974 Getting Started Guide

Table 6. Connector Descriptions Connector REF OUT REF IN PPS TRIG OUT PPS TRIG IN GPS ANT Use Output terminal for an external reference signal for the LO on the device. REF OUT is an SMA (f) connector with an impedance of 50 Ω, and it is a single-ended reference output. The output signal at this connector is 10 MHz at 3.3 V. Input terminal for an external reference signal for the LO on the device. REF IN is an SMA (f) connector with an impedance of 50 Ω, and it is a single-ended reference input. REF IN accepts a 10 MHz signal with a minimum input power of 0 dbm (0.632 V pk-pk ) and a maximum input power of 15 dbm (3.56 V pk-pk ) for a square wave or sine wave. Output terminal for the PPS timing reference. PPS TRIG OUT is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input. The output signal is 0 V to 3.3 V TTL. You can also use this port as a triggered output (TRIG OUT) that you program with the PPS Trig Out I/O signal. Input terminal for PPS timing reference. PPS TRIG IN is an SMA (f) connector with an impedance of 50 Ω and is a single-ended input channel. PPS TRIG IN accepts 0 V to 3.3 V TTL and 0 V to 5 V TTL signals. You can also use this port as a triggered input (TRIG IN) that you control using NI-USRP software. Input terminal for the GPS antenna signal. GPS ANT is an SMA (f) connector with a maximum input power of -15 dbm and an output of DC 5 V to power an active antenna. Notice Do not terminate the GPS ANT port if you do not use it. PCIe x4 SYSTEM POWER IN Port for a PCI Express Generation 2, x4 bus connection through an MXI Express four-lane cable. Can be used to connect an external USRP device or external chassis. Input that accepts a 15 V ± 5%, 10 A external DC power connector. USRP-2974 Getting Started Guide National Instruments 15

Designed by E tus Research RF 0 RF 1 AUX I/O 3.3 VDC MAX Where to Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks. EXPLORE LEARN CREATE the application development environment (ADE) for your application. about hardware features or review device specifications. custom applications with an application programming interface (API). LabVIEW Communications SystemDesign Suite Manual USRP-2974 Specifications USRP Software Defined Radio Stand-Alone Device Manual NI-USRP Instrument Driver NI-USRP Sample Projects* LabVIEW Communications System Design Suite Manual RF Solutions ni.com/rf DISCOVER more about your products through ni.com. Services ni.com/services Updates ni.com/updates *This item is also installed with the driver software. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for information about the services NI offers. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information. 16 ni.com USRP-2974 Getting Started Guide

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2018 National Instruments. All rights reserved. 377416A-01 May 25, 2018