Chapter. In this Chapter... Safety Guidelines Introduction Panel Cutout Dimensions (all models) Wiring Guidelines...

Similar documents
Chapter. Getting Started. In this Chapter...

CHAPTER ACCESSORIES. In This Chapter...

Chapter. Accessories. In this Chapter...

Chapter. Accessories. In This Chapter...

Chapter. Maintenance. In this Chapter...

Chapter. Specifications. In this Chapter...

Chapter. Accessories. In this Chapter...

Installation and Wiring

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Chapter. Getting Started. In this Chapter...

2 In This Chapter...

CHAPTER MAINTENANCE. In This Chapter...

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

InView Marquee Message Display

PanelView Plus/VersaView CE Terminals and Display Modules

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

System Storage EXP3000 Rack Installation Instructions

Chapter. Troubleshooting. In this Chapter...

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Rack Installation Instructions

i 2 Index Communications Ports, 2 6 Conventions Used, 1 3 exclamation mark, 1 3 notepad, 1 3

PS/IO Circuit Board Retrofit

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Rack Installation Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

The information in this chapter will enable you to: Understand the product's basic functions & features

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Chapter. System Setup Screens. In this Chapter...

General Specifications. P2-SCM Serial Communications

Optional Accessories 6 2

MODEL BFD - BIG FLEXIBLE DISPLAY

Installation Guide. Direct

Rack Installation Instructions

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

PowerLogic High Density Metering System 1-Meter Enclosure

YASKAWA AC Drive-1000 Series Option Operator Mounting Kit NEMA Type 4X, IP66 Installation Manual Model No.: UUX or UUX000527

Kinetix 6000 Axis Module and Shunt Module

Chapter. Getting Started. In this Chapter...

Series 3700 Screw Terminal Assemblies Installation Instructions

Installing a Power over Ethernet injector

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Series Amp Pad Mount Quick Connect Input and Output Power Panels

InnoMedia Business VoIP ATA Models

IBM. Rack Installation Instructions

PanelView 600 Terminals

Replacing the Billboard Diagnostic Camera

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

hp uninterruptible power system r12000 xr models installation instructions

CHAPTER GETTING STARTED. In This Chapter...

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

* * Agilent Power Distribution Unit (PDU) Installation Guide

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

P/S Accessory Cabinet Installation Manual

Installing the DX LCD Display

Chapter. F0-04AD-2, 4-Channel Analog Voltage Input. In This Chapter...

PLC CommuniCations In This Chapter...

C-more Micro-Graphic Panel Accessories

Memory Expansion for DriveLogix Controller

INSTALLATION INSTRUCTIONS MODEL MRC44KP MRC44 KEYPAD

Marine User Guide. USBT202 Series High Power USB Charging Port

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Series Amp Quick Connect Input and Output Power Panels

Chapter. Troubleshooting

Installing the NEMA 4X Hatch

5 B&W Rear View System Camera

Rack Installation Instructions

Index EA-USER-M Hardware User Manual, 2nd Ed. Rev. H, 05/18 i-2

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter:

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

DIGITAL Server Rackmount Installation Guide

B&W RearView Camera Installation & Operation

GE Power Conversion T1930EN INSTRUCTION SHEET REV. 09 MV3000E DELTA MAINS VOLTAGE MONITOR UNIT MVC X 1. DESCRIPTION

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

MONITORING INTELLIRACK USER MANUAL

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Datapanel. Datapanel 40/45, 60/65 & 85. Operator Interface Products. User's Manual

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Power Supply (48Vdc, 2.5A)

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Chapter. Troubleshooting. In This Chapter...

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

User Operation Manual: Motorized Valve Controller for Valved Sources

Series 3000V Input/Output Board

Setup Guide. KD-CATHD250Lite KD-CATHD250POH. HDBT/HDMI Lite via Single CAT5e/6 (Tx/Rx) Extenders with Full Buffer System, IR

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

N3150 Installation and Setup Instructions

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Installing the Cisco MDS 9020 Fabric Switch

Bulletin 1494H Heavy Duty Safety Switches

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

2.1 MANAGEMENT UNIT INSTALLATION

1.4. Electronic Products. Contents Description E33 esm Keypad Multiplexed Switch Module Product Selection...

TDM To MiniMech conversion ProceDure

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Transcription:

Installation & Wiring hapter In this hapter... Safety Guidelines... - Introduction... - Panel utout imensions (all models)... - Wiring Guidelines... -

hapter : Installation and Wiring 0 Safety Guidelines NOTE: Products with E marks perform their required functions safely and adhere to relevant standards as specified by E directives provided they are used according to their intended purpose and that the instructions in this manual are adhered to. The protection provided by the equipment may be impaired if this equipment is used in a manner not specified in this manual. listing of our international affiliates is available on our Web site: http://www.automationdirect.com Warning: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and installation. utomation systems can fail and may result in situations that can cause serious injury to personnel or damage to equipment. o not rely on the automation system alone to provide a safe operating environment. You should use external electromechanical devices, such as relays or limit switches, that are independent of the PL application to provide protection for any part of the system that may cause personal injury or damage. Every automation application is different, so there may be special requirements for your particular application. Make sure you follow all national, state, and local government requirements for the proper installation and use of your equipment. Plan for Safety The best way to provide a safe operating environment is to make personnel and equipment safety part of the planning process. You should examine every aspect of the system to determine which areas are critical to operator or machine safety. If you are not familiar with control system installation practices, or your company does not have established installation guidelines, you should obtain additional information from the following sources. NEM The National Electrical Manufacturers ssociation, located in Washington,.. publishes many different documents that discuss standards for industrial control systems. You can order these publications directly from NEM. Some of these include: IS, General Standards for Industrial ontrol and Systems IS, Industrial Systems IS, Enclosures for Industrial ontrol Systems NE The National Electrical ode provides regulations concerning the installation and use of various types of electrical equipment. opies of the NE Handbook can often be obtained from your local electrical equipment distributor or your local library. Local and State gencies many local governments and state governments have additional requirements above and beyond those described in the NE Handbook. heck with your local Electrical Inspector or Fire Marshall office for information. - E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/

hapter : Installation and Wiring Introduction The installation and wiring of -more Micro-Graphic panels require selecting an appropriate location for the panel, laying out the cutout dimensions on the surface of the control cabinet that the panel will be mounted through, securing the panel with the provided mounting clips, tightening the screws to the appropriate torque rating to assure the gasket is sealing correctly, and finally connecting the appropriate power source to the panel. Note: Each -more Micro-Graphic panel is provided with a cutout template to make marking the proper cutout size on the surface of the control cabinet that the panel will be mounted through a simple task. The keypad bezels are also provided with an appropriate cutout template for mounting convenience. The -more Micro-Graphic panels include two mounting clips. The clip is a long metal bracket with two screws. It is fitted to the panel by inserting two tabs into mating slots on the panel and then sliding the clip into a narrower slot to secure it in place. If using the panel with either the -button or 0-button Keypad ezel, then install the panel into the keypad bezel and secure with the mounting clips that are provided with the panel. reate a cutout in the enclosure that the assembled panel and keypad bezel will be mounted through and secure the assembly with the mounting clips that are provided with the keypad bezel. See hapter : ccessories for additional details. This chapter only covers the proper mounting of the panel and connecting power. Once power is applied to the panel, read hapter, System Setup Screens, to check the information menu to make sure the panel has the latest version of firmware, become familiar with the panel test features, and check the memory usage. The next step will be to select the appropriate PL protocol and communications cable as described in hapter. Panel Mounting lips E-MG-SML-RK -utton Keypad ezel Mounting lips E-MG-Z-RK 0-utton Keypad ezel Mounting lips E-MG-Z-RK 0 E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/ -

hapter : Installation and Wiring 0 Panel utout imensions (all models) The -more panel is mounted into a cutout through the control cabinet and secured with two () mounting clips. The mounting clips are provided with the panel. There is a set of two () T shaped holes (slots) on each side of the panel s long dimension that the two tabs on each mounting clip will match. The mounting clips are held in place by inserting the tabs into the T shaped holes (slots) and then moving the mounting clip toward the rear of the panel to keep it in place. Next tighten the mounting clip screws to pull the rear of the panel s bezel to the control cabinet s mounting surface. The screws need to be tightened to the torque rating shown in the illustration below so that the gasket is compressed to form the proper seal between the panel and cabinet surface. 0. [.0]. +0.0 0.00 0.0 + 0 0. [.0] 0. [.0] R0. [R].0 +0.0 0.00 0.0 + 0 0. [.0] UTOUT MOUNTING LIP () places Enclosure Mounting Thickness Ranges and Mounting racket Screw Torque MOUNTING LIP () places ENLOSURE MOUNTING THIKNESS RNGE 0.0" 0." [ mm] NOTE: minimum clearance of. inches (0mm) must be maintained around and behind the panel to allow for proper cooling. Units: inches [mm] UTOUT OUTLINE EZEL OUTLINE MOUNTING LIP SREW TORQUE RNGE - oz-in [0.-0. Nm] - E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/

hapter : Installation and Wiring Wiring Guidelines Warning: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at -00--00 or 0--00. This publication is based on information that was available at the time it was printed. t utomationdirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without obligation. This publication may also discuss features that may not be available in certain revisions of the product. Providing Power to the Micro-Graphic Panel The -more Micro-Graphic panel is powered during programming from the P through the US to RS- Programming able ssembly, E-MG-PGM-L. uring operation, the -more Micro-Graphic panel can be powered from most utomationirect PL s RJ serial communications port by using a V-000L communications cable, or a V-000L communications cable with a F-H -pin H Sub/RJ dapter connected to a irectlogi PL s -pin H communications port (L0, -0- & -0) PLs. See hapter : PL ommunications for additional details. The panel can also be powered by installing either the E-MG-P Power dapter, or the E-MG-SP Serial Port with Power dapter to the back of the panel and supply the adapter from a mp @ - V power source. Panel Powered from utomationirect PL via ommunications able To PL RJ Port = Sig = + V = RX = TX = not used = Sig Power Supplied to Panel through able from utomationirect PL s, RS- (p/n V-000L) RJ -pin Phone Plug (P) TX RX + V 0 feet [.0 m] Maximum Wiring iagram NOTE: Maximum cable length when the panel is powered via the V-000L using an utomationirect PL is 0 feet. Wiring Guidelines continued at top of the next page. RX TX + V RJ -pin Phone Plug (P) To -more Micro-Graphic Serial Port = Sig = not used = RX = TX = + V = Sig 0 E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/ -

hapter : Installation and Wiring 0 Wiring Guidelines (cont d) Panel Powered from a Power dapter Wiring iagrams Recommended Supply Fuse 0 m fast acting, p/n G- + Equipment Ground Power dapter E-MG-P Supply to adapter: @ - V (0. -. V) Tightening Torque Power supply wire connection. lb-in (0. Nm) NOTE: Recommended power supply to power either Power dapter, utomationirect Part No. PS--0 or PS--00. NOTE: If either the E-MG-P Power dapter or the E-MG-SP Serial Port with Power dapter is installed on the Micro-Graphic panel, then the adapter must be powered. The error message below will be displayed on the panel if power is not applied. The RJ serial communications port (Port ) on the panel can still be used to communicate with a PL or control device while using one of the adapters, but the + V power through the serial cable from utomationirect PL s RJ serial comm port is not used. Wiring Guidelines continued at top of the next page. Recommended Supply Fuse 0 m fast acting, p/n G- + Equipment Ground R00: Option module detected without external power F F F F F Serial Port with Power dapter E-MG-SP Port Supply to adapter: @ - V (0. -. V) Required Wire Specif ication Supported temperature Over 0 Wire Material opper Wire Size - WG - E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/

hapter : Installation and Wiring Wiring Guidelines (cont d) Maximum communication cable length when powered from optional Power dapter is 0 ft. ( m) To PL Port onnector able wiring example when power is supplied to panel from either a Power dapter, E-MG-P, or a Serial Port w/ Power dapter, E-MG-SP RX TX 0 feet [.0 m] Maximum Wiring iagram RX TX RJ -pin Phone Plug (P) To -more Micro-Graphic Serial Port = Sig = do not use = RX = TX = + V = Sig 0 E-MG-USER-M Hardware User Manual, nd Ed. Rev. F, 0/ -