JVA SMS Gateway User Manual

Similar documents
JVA Z Series Integration Options and Methods

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

gridcomm GC1310 Master Light Controller Hardware Installation Guide

SMS ALERT 15 User Manual

JVA Z Series Keypad Bus Wiring Installation Manual

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

SMS TEXT DIALLER INSTALLATION AND OPERATION MANUAL

SMS Commander Manual

Connecting a Cisco Output Module

UP100-GSM. GSM based intercom and access control. Installation and user manual

MODEM for REMOTE SWITCH CONTROL V1.20

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

GPRS Pager 3 INSTALATION AND USER MANUAL

Installation Instructions

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Environdata FA ma Converter Guide

GSM TEMPERATURE ALARM DIALLER

Installation Manual & User Instructions. MultiCom 500

A1000 GSM ALARM DEVICE

GC 055. GSM Remote Monitoring. Operating and installation instructions

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

page A.0240 Full_Product_catalogue_ BM.indb 110

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

SMS Transceiver V3 User manual

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

GSM TEXT PAGER OPERATION AND INSTALLATION MANUAL 5 SIMPLE OPERATION TEST STEPS. Model: MTP4

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18

Installation advice / help

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

Installation Manual & User Instructions

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

EverPump Wireless Pump control system

GSM AUTO DIALER WITH IR BEAM DETECTOR

rev mobile device to remotly control your home 2010 Cybrotech Ltd

CA111x-series Arming Station

VOICE and/or DATA CELLULAR SYSTEM

Wireless Key fob, Key pad & Receiver Range

ProLine GSM. Installation manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Installation & User Manual For Cell Box Switch. GSM Cellular Gate opener and GSM alarm signalling device.

User Manual. PCKeypad Wireless Keypad

MODBUS MASTER ALERTING SMS MODEM V1.50

TOYOTA CANBUS GSM TEXT PAGER

CONTROL ANYTHING WITH YOUR CELLPHONE. Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100

CCTR-820 Mini Water-proof GPS Tracker Using Guide

Suprex RS-485 SPX-7500 Wired Reader-Extender

VOICE and/or DATA CELLULAR SYSTEM

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

GSM communicator GD-06 Allegro Complete manual

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

PRODUCT RANGE. Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button

Installation Manual & User Instructions. MultiCom 100 / 500

Rotator Genius Instruction Manual v1.3.3

NEOS3000A GSM Least Cost Wireless Router

USER MANUAL Mobeye CM-Guard CM2000

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

UP200-GSM Intercom and access control unit operating on mobile GSM network

Installation and Hardware Guide

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

Two Door Controller GEN-045

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

GSM-REMOTE CONTROL FOR PRE-HEATERS. Webasto/Eberspächer. GSMS-PH5 Manual

Digital Keypad Introduction

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

GSM SECURITY AND CONTROL SYSTEM ESIM021

Quick Start. Appearance and pin assignments

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Installation guide for PR302 v2.0 Rev. E

MONGOOSE VT606 GPS VEHICLE TRACKER

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed.

MANUAL 3G GATE OPENER

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

Cellcop Communicator CP72u-M

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

B-33. Hardware and Install Manual. (DC 12V / PoE)

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

EasyCon GSM. Installation manual

MANUAL PIN CODE KEYPAD February 2013

The device works in conjunction with standard alarm systems and is designed for the transmission of alarm messages by GSM network.

Universal GSM/GPRS Communicator gemino BUS

User Manual Revision 1.02

CCTR-829 GPS Tracker Using Guide

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

HydroGuard Expert Pool Manual

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Transcription:

www.jva-fence.com.au JVA SMS Gateway User Manual PTE0319

JVA SMS Gateway User Manual Introduction The PTE0319 JVA SMS Gateway enables a group of JVA Z Series energisers to be controlled and monitored by SMS from anywhere in the world. With a short SMS, users can obtain an up-to-date status report of all their energisers, turn on (arm) or off (disarm) all the energisers at once, as well as switch convenient output relays for custom applications. If an energiser goes into alarm, or one of two inputs are triggered, an SMS will be automatically generated and sent to up to 10 stored numbers. Designed with ease of use in mind, all configuration is via SMS to the unit. Commands are secured with a user definable PIN. The JVA SMS Gateway communicates on the widely supported and robust GSM or 3G mobile phone networks, and will work in any country. Simply insert a valid topped-up SIM card from your preferred carrier and you are ready to remotely control and monitor your energisers from anywhere in the world. Features Works with entire JVA Z range of energisers, including the ZM1, ZM20, ZM50 and ZLM4 monitors Can monitor and control up to 15 devices (linked via Keypad bus), as well as two dry contact inputs and two 30Vdc 8A relays Produces an up-to-date status report including arm state, alarms and primary voltages of each device, and input and output states Responds to status request by SMS Can store up to 10 phone numbers to be notified if a device goes into alarm, or one of two inputs are triggered All commands secured by user configurable PIN Easily configurable by SMS Compatible with the all types of JVA Keypad Works in conjunction with Perimeter Patrol Specifications Power supply Inputs Outputs SIM Antenna connector 12 V DC 1A Dry contact or active pull-down 30Vdc 8A SPDT Micro Female SMA 1

Contents JVA SMS Gateway User Manual Introduction... 1 Features... 1 Specifications... 1 Contents... 2 Overview... 3 LED Indicators... 3 Inputs... 3 Outputs... 3 Antenna... 4 Power and Keypad Bus... 4 SIM card... 4 Installation... 5 Energiser Configuration... 5 Operation... 6 SMS Commands... 6 PIN... 6 Querying the Status... 6 Querying the GSM signal... 7 Report List... 7 Controlling Energisers and Outputs... 7 Alerting users... 7 Basic Commands... 8 Command Summary... 9 Troubleshooting... 10 Support... 11 Factory Reset... 11 JVA Distributors... 11 2

JVA SMS Gateway User Manual Overview LED Indicators KPB GSM ERROR Blink when the unit is communicating with Z series devices Blinks when the processor is communicating with the GSM module Flashes when there is a problem with the SIM (faulty or PIN locked) Inputs Two dry contact inputs are provided. If the unit sees a short circuit between the input terminals it will register the input as being On. Just like the inputs on all JVA Z series devices, the input can also be triggered by PLC or alarm panels by connecting the right-hand terminal to 0V. Outputs Two SPDT relays are available as general purpose outputs. These relays can switch DC voltage up to 30V and 8A. The outputs can be switched on or off by SMS, and are ideal for connection to external lights, pumps, electric motors, gate openers, or interfacing to an existing alarm or control system. 3

Antenna JVA SMS Gateway User Manual A GSM antenna is supplied and must be connected to the unit for it to communicate on the mobile network. If mobile reception in the area is particularly weak, the antenna can be substituted for a more powerful one provided it has a compatible SMA connector. Ensure the antenna is mounted away from any high voltage cables or AC power cables which could cause interference. If the unit is mounted inside a metal enclosure, the antenna should be mounted externally and the cable entry hole be sealed against water ingress. Power and Keypad Bus The keypad bus enables digital communication between the SMS Gateway and connected devices. Connect the DATA and GND terminals to the respective terminals of all connected devices. The SMS Gateway requires 12V dc to operate. This power may be supplied from the keypad bus of a connected energiser, or for best results a separate 12V 1A power supply may be used. Do not connect the unit to a separate power supply and keypad bus +12V of an energiser at the same time. The SMS Gateway operates as a keypad with keypad ID 2. Keypad ID 3 is reserved. If other keypads or keypad devices such as the PAE212 or Perimeter Patrol are to be used with the group, they should be set to keypad ID 1, 4, or greater. SIM card The unit does not use data or voice calls, only SMS. A suitable pre-paid or post-paid plan should be chosen that offers cheap or unlimited SMS messages for sites requiring frequent status updates, or long credit expiry time for sites requiring infrequent updates. 4

JVA SMS Gateway User Manual Installation Detach the front of the case by gently lifting the side clips. Unclip the top of the circuit board to remove from the case back. Mount the case back using suitable screws. Be sure the screw head will not contact the PCB when it is re-installed. The unit must be mounted indoors or in a suitable enclosure to protect it from moisture. It is NOT water proof and damage due to moisture is not covered by the warranty. The SMS Gateway requires a micro SIM card. Activate it according to the instructions, either via the internet or by phone, and make sure it has credit available. The SIM card should first be tested in a phone to ensure it can send and receive text messages. Insert the SIM card into the unit, contact side down with the notched corner to the lower right. Clip the circuit board into the case back. Connect the antenna. Mount the antenna away from high voltage and mains power cables, vertically if possible. If the unit is housed in a metal enclosure, the antenna should be mounted outside the enclosure and the enclosure earthed. Connect 12V plus and minus to an external power supply. Connect Data and Ground wires from the unit to a JVA energiser. Power on the unit and the energiser(s). Confirm the KPB and GSM lights are flashing, and ERROR light is not flashing. Clip the case front back on. Your JVA SMS Gateway is ready to use. Energiser Configuration If the SMS Gateway is being used with a stand-alone energiser, the energiser may need to be reconfigured to operate correctly. If the energiser has firmware earlier than 8v20, it must be programmed to ID 1. This will require the use of a keypad. Refer to the energiser manual for more information. 5

Operation JVA SMS Gateway User Manual SMS Commands The unit is controlled and configured by SMS. All commands are of the format PIN command parameter with spaces separating each part. The commands and parameters are not case sensitive. Many commands may be replaced with only their first letter. A help message can be requested by issuing the help command. summarised list of available commands. The unit will reply with a PIN All commands are prefixed by a PIN number, to secure the unit against unauthorised changes. The PIN must be between 4 and 12 digits long. The default PIN is 1234. The PIN can be changed by issuing a changepin command, with the new PIN as the parameter. If successful the unit will reply and inform everyone on the report list of the new PIN. If you forget the PIN, a factory reset must be performed. See the section Factory Reset for more information. Querying the Status The SMS Gateway can be queried to return the status of the inputs, outputs and all Z series devices connected to it via the Keypad Bus by issuing a status command. The response will take the following format: Model(ID) <On (V1, V2, ) or Off> <Alarms> Model(ID) <On (V1, V2, ) or Off> <Alarms> In1 <on off> In2 <on off> Out1 <on off> Out2 <on off> Model Energiser model eg Z14, ZM20 ID Keypad bus device ID (1-15) V1, V2, Primary voltages, usually feed and return, in kv, V or A. Device dependent. ZM1: Feed, Return, Ground, Current ZM20: Feed, Ground, Current 1, Current 2 ZLM4: Zone Voltages 1-4 Z1x: Return, Feed Z2x: Return 1, Return 2 Alarms CommsFail OR FenceAlarm1 FenceAlarm2 AcFail LowBatt BadBatt Tamper Fault GateAlarm OR No Alarms 6

JVA SMS Gateway User Manual Querying the GSM signal The GSM status of the unit can be requested by issuing a gsm command. The unit will reply with signal strength from 1 to 30, and the firmware version. Report List The unit can store up to 10 phone numbers which it will SMS if a device goes into alarm or an input changes. This list is configured and maintained using the add and remove commands. You can retrieve the current list of numbers using the numbers command. Issuing an add command with no further parameters will add the sending number to the report list. Issuing an add command, followed by a valid number, will add the supplied number to the report list. Numbers can be in either the national format, eg 0412 345 6789, or international dialling format, eg +61 412 345 6789. International format is recommended, as this reduces the chance of adding duplicate numbers to the list. If this were to happen, that number would receive two messages each time an SMS is broadcast. After successfully adding a number the unit will reply with a confirmation message. Numbers can be removed by issuing the remove command. If no parameter is supplied, the sending number is removed. If the parameter is supplied it can be either the number you wish to remove, or the position of the number in the report list. If entering a number, it must be in the same format as it is stored in the list. After successfully removing a number the unit will issue a confirmation message. Controlling Energisers and Outputs The unit can turn all energisers on (arm) or off (disarm) by issuing the on or off commands. When arming, the unit will arm in high power only, and arm both channels of any dual channel energisers. When the unit has confirmed the new arm state it will reply to the sender with a confirmation message, or a message indicating it was unable to control all devices (in the case of a device being offline). The unit has two relays than can be turned on or off. Issue an output1 or output2 command with the parameter on or off. Note there is no space between output and the number 1 or 2. The unit will reply with a confirmation message. Alerting users The unit monitors the connected energisers and will send a SMS to everyone on the report list if the following things occur: A fence alarm occurs, usually due to a short on the fence An energiser stops communicating An input changes If multiple energisers report changes at the same time, the unit will send one SMS for each change. 7

Basic Commands JVA SMS Gateway User Manual The following is the minimum commands you will need to know to get your JVA SMS Gateway working. It assumes the PIN is still set to the default of 1234. When you have installed and powered on your unit for the first time, the connected energiser(s) are powered on, and the GSM light is flashing once every 2 seconds, issue a status command 1234 s The unit will reply with a summary of all connected energisers. Next, add your number to the report list. Send 1234 a The unit will reply with <your number> has been added to the report list Now try arming you energiser(s) by sending 1234 on You should see the energiser(s) arm, and receive an sms saying Energiser(s) are on. Now disarm the energiser(s) by sending 1234 off You will see the energiser(s) disarm and receive another confirmation message. For a complete list of commands, refer to the section Command Summary. 8

JVA SMS Gateway User Manual Command Summary The table below summarises all available SMS commands. The default PIN is used in examples but you should replace this with your own PIN if it has been changed. Command Description Example Response changepin <PIN> or c <PIN> add or a or add <number> or a <number> numbers or n remove or remove <index> or r <index> or remove <number> or r <number> gsm or g status or s or? help or h on or arm off or disarm output1 <on off> or out1 <on off> or 1 <on off> or aux <on off> output2<on off> or out2 <on off> or 2 <on off> or gate <on off> Changes the PIN 1234 changepin 4321 PIN is now 4321 4321 c 1234 PIN is now 1234 1234 c 123 Invalid PIN Adds your number, or the specified number, to the report list Requests the report list Removes your number, the number at the given index, or the specified number from the report list 1234 a +61412345678 has been 1234 a +61 41 234 5678 added to the report list 1234 a 555JVAROCKS Invalid phone number 1234 numbers 1234 n 1234 r 1234 remove 1 1234 r +61412345678 1234 r 2 1234 remove 041 234 5678 1.+61412345678 +61412345678 has been removed from the report list Number not found in report list Requests GSM status 1234 gsm Signal: 25 Fw: 2v00 Requests energiser/monitor primary voltages, arm and alarm state, and unit input and output state Requests a command summary 1234 status 1234 s 1234? 1234 help 1234 h 1234 Z14(1) On (6.8kV, 6.4kV) No alarms ZM20(2) Off LowBatt In1 Off In2 Off Out1 On Out2 Off This table, summarised Arms all devices 1234 on Energiser(s) are on Disarms all devices 1234 off Energiser(s) are off Controls relay 1 or 2 1234 output1 on Output 1 is now on 1234 1 off Output 1 is now off 1234 out2 on Output 2 is now on 1234 gate off Output 2 is now off 9

Troubleshooting JVA SMS Gateway User Manual The JVA SMS Gateway is designed to work straight out of the box with little set up or configuration. The only crucial step is to ensure the unit has good mobile reception and an activated SIM card with credit. Refer to the troubleshooting table below for more information. Fault Likely Cause Remedy No lights are on Power is not connected Power wires are reversed Check power connections Check voltage at power connections with a multimeter KPB light not flashing Keypad bus is not connected Check the keypad bus DATA and GND connections Error light flashing Unit does not respond to SMS Unit responds to SMS commands but does not reply Unit does not control energisers SIM card not inserted, not activated, or PIN locked Poor signal strength Insufficient or expired credit Another keypad or keypad device is connected with keypad ID 2 Energiser malfunction Group configured incorrectly Confirm SIM is activated by inserting into a mobile phone and sending and receiving texts Check antenna connection Move antenna mounting place Check the SIM card has credit available Disconnect the other keypad, or change its ID to 1, 4, or greater Confirm a JVA keypad can control the energiser using the same connections If there is more than one energiser, ensure one is configured as master (device ID 1) and the others have unique device IDs of 2 or more If the unit is still not working correctly, contact your nearest JVA distributor for technical support. 10

JVA SMS Gateway User Manual Support Factory Reset If the PIN has been changed from its default setting and has been forgotten, the unit will need to be factory reset. A factory reset will also clear the memory of seen devices, necessary if devices have been added or removed. To reset, remove power from the unit. Remove J4. Apply power to the unit, wait 5 seconds, then reapply J4. This will reset the PIN to default, clear the report list, and clear the memory of seen devices. JVA Distributors If you have any questions or need further assistance, please email us at sales@jva-fence.com.au or call Region Number Australia 07 3103 0582 South Africa 0861 782 349 World Wide +61 7 3103 0582 For more information on our complete range of electric fencing products please see the JVA website www.jva-fence.com.au JVA 2016. Manufactured for JVA by Pakton Technologies The JVA logo is a trademark of JVA Technologies Pty Ltd ST087 1v03 11