PACSystems RX3i IC695PSA140

Similar documents
PACSystems* RX3i IC695PSA140

PACSystems* RX3i IC695PSA040

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

IC693PWR331 High Capacity Power Supply, 24 VDC Input

PACSystems RX7i IC698CHS009/119

Power Supplies IC697PWR724/CE697PWR724

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

PLC Racks IC697CHS782/783

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PACSystems RX7i IC698CMX016-ED

Digital ac/dc (24V) Input Module

Installation Instructions

PACSystems RX3i IC695HSC304 and IC695HSC308

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

Redundancy unit CP-A RU

Installation and Wiring

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Programmable Controller IC697ACC721/724/744

IC693 PLC IC693ACC350, IC693ACC340/341

PV Rapid Shutdown device

Replacing the Power Supply

Rhino PSM Power Supplies. Operating Instructions

Voltage Dip-Proofing Inverter

Installation Instructions

Power Supply and Fan Module Installation

Power Supplies IC697PWR710/712

XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115

PACSystems* IC698ACC701C

Installation Instructions

Industrial Power Supplies

PACSystems* RX3i CEP IC695CEP001

PACSystems* RX3i IC695ACC650

PanelView Plus/VersaView CE Terminals and Display Modules

Voltage Dip-Proofing Inverter

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

MINI-PS AC/10-15DC/8

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

Power supply CP-C 24/5.0

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Power Supply Installation

Physical description of the safety modules

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

24 Input/8 Output AC Block I/O Module

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

PACSystems* RXi ICRXIBN0E000A and ICRXIBN0M000A

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

PACSystems* RX3i IC694ALG233

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

Installation Instructions

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

PACSystems* RX3i IC694ALG232

Power Supply (48Vdc, 2.5A)

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Installing the Cisco AS5400XM Universal Gateway

920 Remote Control (RC) Switches

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

Quick Start Guide TS A

QUINT-BUFFER/24DC/24DC/40

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

Series Specialty PLCs

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

GE Fanuc IC695CMM004. Rx3i PacSystem

Analog Voltage Combination Module

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

ASCO 920 Remote Control (RC) Switches

Power supply CP-E 24/0.75 Primary switch mode power supply

Transient Fault Location for Energized Dedicated Circuit Breakers. TFT100 User Manual. Toll Free:

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

RTU500 series Data Sheet Power Supply CP-E 24/2.5

BMX DDM Mixed Relay Input/Output module

Power supply CP-E 24/10.0 Primary switch mode power supply

STEP-PS/1AC/24DC/1.75

PM Series Power Meter

Transcription:

GFK2399A October 2005 PACSystems RX3i IC695PSA140 120/240VAC or 125VC, 40 Watts IC695PSA140 is a multipurpose 40Watt supply that operates from an input voltage source in the range of 85 to 264 VAC or 100 VDC to 300 VDC. This power supply provides three outputs: +5.1 VDC output, +24 VDC relay output that can be used to power circuits on Output Relay modules. +3.3 VDC. This output is used internally by RX3i modules with IC695 catalog numbers. POWER P/S FAULT OVERTEMP OVERLOAD 40W AC This is suitable for use in loadsharing and redundancy applications. Up to 4 Multipurpose power supplies (PSA140 and/or PSD140) can be used in a PACSystems RX3i (IC695 catalog number) Universal Backplane. Use these Supplies if the number of modules required exceeds the capacity of one. This occupies two backplane slots. Caution This cannot be used with RX3i IC695PSD040 or IC695PSA040 Supplies in redundant or increased capacity modes. Damage to equipment may result. Load Sharing When RX3i DC Supplies are combined into loadsharing applications following the installation guidelines given in this datasheet, they must be wired to the same power source in such a way that they all can be powered up or powered down simultaneously. The On/Off front panel switch on each of the power supplies must be left in the On position. PACSystems RX3i Caution In a loadsharing application, it is important to ensure that the loadsharing power supply modules On/Off switches cannot be inadventently used. The minimum number of power supplies needed to meet the system power requirements MUST have their switches always kept in the On position. Also, the loadsharing power supplies must be connected to the system power source through the same external switch. The system must be powered up and powered down only from the external switch. If individual power supplies are powered up or powered down using their On/Off switches or separate external switches, resulting in insufficient power capacity, equipment damage may result. It may be necessary to reload the PLC operating system to resume operation.

2 RX3i 120/240VAC or 125VC, 40 Watts GFK2399A The following information is for products bearing the UL marking for Hazardous Locations: WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2; WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NONHAZARDOUS LOCATIONS ONLY The tightening torque range for the control terminals is 9.611.5 in. lb. Use only wire rated for 90 C. Be sure to observe any additional ratings that are provided with the modules. Batteries: Replace Battery with Matsushita Part No. BR2477A Only. Use of another battery may present a risk of fire or explosion. Caution, Battery may explode if mistreated. Do Not recharge, disassemble or dispose of in fire. The correct battery type is available as Accessory Kit IC698ACC701. LEDs Four LEDs on the indicate: (Green/Amber). When this LED is green, it indicates power is being supplied to the backplane. When this LED is amber, power is applied to the but the switch is off. P/S Fault (Red). When this LED is lit, it indicates the has failed and is no longer supplying sufficient voltage to the backplane. Over Temperature (Amber). When this LED is lit, it indicates the is near or exceeding its maximum operating temperature. Overload (Amber). When this LED is lit, it indicates the is near or exceeding its maximum output capability on at least one of its outputs. The CPU Fault Table shows a fault if any Overtemperature, Overload, or P/S Fault occurs. Wiring Terminals Terminals for L1 and power, ground, and MOV Disconnect accept individual 14 to 22AWG wires. On/Off Switch The OOFF switch is located behind the door on the front of the module. The switch controls the operation of the outputs of the supply. It does NOT interrupt line power. A projecting tab next to the switch helps prevent accidentally turning it on or off. POWER P/S FAULT OVERTEMP OVERLOAD WARNING: EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. PSA040 ON OFF INPUT 120/240 VAC 125 VDC 50/60 HZ 70 W WIRE AWG# 1422 TORQUE 4.4 inlb (0.5 Nm) 75 DEG. C COPPER CONDUCTORS ONLY

RX3i 120/240VAC or 125VC, 40 Watts 3 Overcurrent Protection GFK239A9 The 5.1 VDC output is electronically limited to 7 Amps. The 3.3 VDC output is limited to 10 Amps. If an overload (including short circuits) occurs, it is sensed internally and the shuts down. Because it is designed for redundancy applications, this latches OFF in fault conditions and will not automatically try to restart. Input power must be cycled to clear a latched fault. However, if the is used in a nonredundant application where automatic restarting is required, a jumper plug can be installed. An internal fusable link in the input line is provided as a backup. The usually shuts down before the fusable link blows. The fusable link also protects against internal supply faults. The CPU Fault Table shows a fault if any Overtemperature, Overload, or P/S Fault occurs. There is no additional indication if the fusable link blows. Location for optional jumper plug In a nonredundancy application, where automatic restarting may be appropriate, a shunt can be installed on back of the module as shown at left. The shunt must have 0.100 inch spacing on center and accommodate 0.25 inch pins. Example parts are Radio Shack DIP Programming Shunt #2761512 and DIGIKey #59000 ND. The module must be removed from the backplane to install the shunt. Specifications: IC695PSA140 Nominal Rated Voltage Input Voltage Range AC DC 120/240 VAC or 125 VDC 85 to 264 VAC 100 to 300 VDC Input (Maximum with Full Load) 70 Watts maximum Inrush Current 4 Amps, 250 milliseconds maximum * Output 40 Watts maximum total 5.1 VDC = 30 Watts maximum 3.3 VDC = 30 Watts maximum The maximum total output power available depends on the ambient temperature, as shown. Output Voltage 24 VDC: 19.2 VDC to 28.8 VDC, 5.1 VDC: 5.0 VDC to 5.2 VDC (5.1 VDC nominal), 3.3 VDC: 3.1 VDC to 3.5 VDC (3.3 VDC nominal) Output Current 24 VDC: 0 to 1.6 Amps, 5.1 VDC: 0 to 6 Amps, 3.3 VDC: 0 to 9 Amps Isolation (input to backplane): Ripple (all outputs) Noise (all outputs) Ridethrough time Wiring Terminals Current per Terminal Number of DaisyChained PSA140 Supplies Number of PSA140 Supplies in Universal Backplane 250 VAC continuous; 1500 VAC for 1 minute 150 mv 150 mv 20 ms. This is the length of time the maintains valid outputs if the power source is interrupted Each terminal accepts one 14 AWG to 22 AWG wire. 6 Amps Up to 4 Up to 4 * The Inrush Current specification is given as a guide for sizing the external power source for the IC695PSA140. Peak inrush current may be higher for shorter durations. Warning The power supply s door must be closed. During normal operation with an AC power source either 120 VAC or 240 VAC is present on the AC. The door protects against accidental shock hazard that could cause severe or fatal injury to personnel.

4 RX3i 120/240VAC or 125VC, 40 Watts GFK2399A Thermal Deratings: PSA140 The maximum output power for PSA140 depends on the ambient temperature, as shown below. 5V fully Loaded 45 40 (W) 35 30 25 20 15 10 5 0 0 10 20 30 40 50 60 Temperaure (C) 5V 3.3V Total 3.3 V Fully loaded (W) 45 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 60 Temperature (C) 5V 3.3V Total

RX3i 120/240VAC or 125VC, 40 Watts 5 Field Wiring: IC695PSA140 GFK239A9 and Ground Connections The wires from the power source and ground connect to the terminals on the as shown at right. Each terminal accepts one AWG 14 to AWG 22 wire. Warning If the same external AC power source is used to provide power to two or more power supplies in the system, connection polarity must be identical at each RX3i power supply. A resulting difference in potential can injure personnel or cause damage to equipment. Also, each backplane must be connected to a common system ground. Input Overvoltage Protection The bottom terminal is normally connected to frame ground with a userinstalled jumper as shown at lower right. If overvoltage protection is not required or is supplied upstream, no jumper is required. To Hipot test this supply, overvoltage protection must be disabled during the test by removing the jumper. Reenable overvoltage protection after testing by reinstalling the jumper. Keep as short as possible. Connect directly to mounting panel. Jumper strap connects overvoltage protection devices to frame ground To additional units To additional units + / L1 / N / Screw Terminals Frame Ground Field WiringTerminals Yes No Each terminal accepts one AWG 14 to AWG 22 wire. The end of each wire should be stripped at least 3/8inch (9mm). The terminal can accept a wire that is stripped up to 11 mm (.433 in) while providing full seating of the insulator. The wire must be fully inserted as shown at left, so that the insulation meets the insulation stop position inside the terminal. Tightening the terminal screw pivots the clamp firmly against the stripped end of the wire, holding it in place. If the wire is not fully inserted as shown at right, tightening the terminal screw may push the wire upward so that it is not connected.

6 RX3i 120/240VAC or 125VC, 40 Watts GFK2399A Connections for Load Sharing In loadsharing installations, additional Supplies above the minimum required for the system load may be wired to the same power source, or a different source. A B External Switching Device Example: Supplies Needed to Meet Load Requreements Extra Optionally Connected to Different Connections for Redundancy redundancy can be provided by using one additional above the minimum required for the system power load. In this type of installation, all Supplies contribute a share of the backplane power and run at a correspondingly reduced load. This results in longer life for the individual power supplies. In addition, should one power supply module fail, system operation is not interrupted. The front panel switch can be used to remove a redundant unit. Note that this type of system does not provide protection against loss of the input power source. If more than power supply is switched off, the remaining power supplies may become overloaded and shut down. An External switching device must be used to remove power from more than 1 power supply at a time in the Redundancy mode. A Optional B Example: Three Supplies Needed to Meet Load Requirements This Extra Provides Module Redundancy Redundancy If the overall power needs of the system can be met using either one or two Supplies, then power source redundancy can be provided. This requires using twice the minimum number of Supplies required to meet the system load requirements. In this type of system, half of the Supplies must be connected to one power source and the other half must be connected to a separate source. This arrangement provides all the advantage of a Basic Redundancy system, as described above, plus power source redundancy. The front panel switch may be used to remove an individual power supply as long as the minimum number of units remain powered up. A B External Switching Device External Switching Device Example: Two LoadSharing Supplies Needed to Meet Load Requirements Two Extra LoadSharing Supplies Provide Redundancy