Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Similar documents
Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Complete UL/CSA Disconnect Switch Kits

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

Non-Fusible Disconnect Switches

194E FA 32 E P11 P11 6

Non-Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches

The safest way to switch power on and off in your industrial control panels.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Disconnect Switches. Safe Switching and Disconnecting

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

194E FA 32 E P11 P11 6

Allen-Bradley 1492-RCDA4A40

Allen-Bradley Drives

ALLEN BRADLEY RELAY Bulletin 700-HF

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Bulletin 1489 Circuit Breakers. Selection Guide

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

1492-SP Supplementary Protectors

60103 Circuit Breaker

Bulletin 700-HA Tube Base Relay

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

the Santon FCS-type switch Disconnect Superior Switch Solutions

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

140M C 2 E A63 KN CC GJ

DeltaV Bulk Power Supplies

TeSys IEC Contactors and Overload Relays

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Allen-Bradley 700-K40E-DJ

DeltaV Bulk Power Supplies

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

920 Remote Control (RC) Switches

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

194E FA 32 E P11 P11 6

140M C 2 N A63 KN CC GJ

Bulletin 817 Thermistor Protection Relay

Selection Guide. Control Circuit and Load Protection

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Section 4 Ground-Fault Protection Devices

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Manual Motor Control Switches and Disconnects

ASCO 920 Remote Control (RC) Switches

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Contents. Volume 5 Motor Control and Protection CA E December

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Motor protection relays

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Bulletin 700-HL 2-Pole Terminal Block Relay

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Miniature Circuit Breakers and Supplementary Protectors. Contents

Supplemental Protectors

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Control Circuit and Load Protection Products

MSR178DP. Description. Features. Specifications

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Selection Guide. Control Circuit and Load Protection

Magnetic and Hydraulic-Magnetic Circuit Breaker

Cat. No. (Spring Clamp. Input Voltage

K1B004TLH cam switch - 1 pole A - screw mounting

C 2 5 D N A A A

Circuit Breakers Type CTI 25M, CTI 45MB

K1D012ULH cam changeover switch - 2-pole A - screw mounting

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

IEC Contactor Specifications

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

Essential Components Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

SECTION DISCONNECT SWITCHES

Large Frame IEC Contactors

Miniature Circuit-Breaker IEC Series 8562

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Product Guide. UL 1077 DIN Rail Supplementary Protectors

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

CS7 Industrial Control Relays

Installation Instructions

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

WMS SUPPLEMENTARY PROTECTORS

Allen-Bradley Bulletin 100 Contactors

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

Transcription:

Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class CC and CSA HRCI-MISC s 0 7. 1 0 0 A CC, HRCI-Misc A1 194R-0-NC UL Class J and CSA HRCI-J s 0 7. 1 0 0 A J, HRCI-J A1 194R-0-NJ 60 1 0 0 60 A J, HRCI-J B1 194R-60-NJ CSA HRCII-C s 0 7. 1 0 0A HRCII-C B1 194R-0-NH 60 1 0 0 60A HRCII-C B1 194R-60-NH Time delay fuses may be required to utilize the disconnect at its maximum horsepower rating. 0 A UL, 40 A IEC 60 A UL, 80 A IEC BS88 s Ratings (AC) With Links -Phase Maximum kw (0 Hz) Load Rating I e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 0. 11 1 BS88 A1 A1 194R-0-NB 9 18. 0 BS88 A1 A1 194R--NB 6 18. 0 BS88 A B1 194R-6-NB DIN s Ratings (AC) With Links -Phase Maximum kw (0 Hz) Load Rating I e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 9 18. 0 NH 000 B1 194R--ND 6 18. 0 NH 000 B1 194R-6-ND NFC s Ratings (AC) With Links -Phase Maximum kw (0 Hz) Load Rating I e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 7. 11 NFC 14 x 1 mm A1 194R--NF 9 18. 0 NFC 14 x 1 mm A1 194R--NF 6 18. 0 NFC x 8 mm B1 194R-6-NF For fuse status indication add S to catalog number, example: 194R-0-NN becomes 194R-0-NNS. classes BS88, DIN, and NFC are not suitable for use in North American applications Replacement Hardware Description For Use With Pkg. Qty. Cat. No. M4 x.7 screws 194R BS88 Types 194R-BS88-M4 M x.6 screws 194R BS88 Types 194R-BS88-M Publication 194R-SG00D-EN-P 11

Overview Bulletin 194R Global 0 A 10 A Sizes d switch versions: - BS88 - DIN - CSA HRCII-C - CSA HRCI-MISC - HRC-L - UL Class J - UL Class CC - UL Class L - NFC Operating handle ingress ratings: - IP4 (Type 1) - IP66 (Type R,, 1, 4, 4X) Handle with or without test mode Padlockable handle for up to three padlocks 6 auxiliary contacts can be added Suitable as service entrance disconnecting means (UL 98) Suitable as at-motor disconnecting means (UL 08) Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 4746, Guide WHTY) CSA Certified (File No. LR14) CE Table of Contents Product Selection... NFPA 79 Internal Operating Handle with Shaft... 1 Specifications... 18 Proper Selection of Disconnect Switches 48 Description... 49 Standards Compliance IEC 60947/EN60947- BS EN60947- VDE 0660 CSA. No. 4 NEMA KS-1 UL 98 UL 08 The Bulletin 194R line of fused and non-fused global disconnect switches provides the flexibility to meet worldwide applications. The disconnect switches are UL Listed and CSA Certified and are designed to meet IEC 60947-, VDE, DIN, BS and applicable NEMA requirements. Publication 194R-SG00D-EN-P

Cat. No. Explanation Catalog Number Explanation Cat. No. 194R-J0-17 Cat. No. 194R-NE160-17 Code C J H B D F L N NE NU a Type Description UL Class CC, CSA Type HRCI-MISC UL Class J, CSA Type HRCI-J CSA Type HRCII-C BS88 DIN NFC UL Class L, CSA Type HRC-L Non-fused (0 6 A) Non-fused, IEC (0 10 A) Non-fused, UL (0 100 A) 194R J 0 17 S Code a b b Load Size Description 0 0 A (BS88) A (NFC) 0 0 A (CC, J, HRCI-J) 0 A (non-fused) 0 A (HRCII-C) A (BS88, NFC) A (DIN) 60 60 A (J, HRCI-J, HRCII-C) 60 A (non-fused) 6 6 A (BS88, DIN, NFC) 0 0 A (BS88, DIN, NFC, J, HRCI-J, HRCII-C) 1 1 A (BS88, DIN, NFC, Non-fused) 160 160 A (BS88, DIN, NFC, Non-fused) 00 0 400 c 00 A (BS88, DIN, NFC, J, HRCI-J, HRCII-C, non-fused) 0 A (BS88, DIN, NFC, J, HRCI-J, HRCII-C, non-fused) 400 A (BS88, DIN, NFC, J, HRCI-J, HRCII-C, non-fused) A (BS88, DIN, NFC, J, HRCI-J, HRCII-C, non-fused) 60 60 A (BS88, DIN, NFC, non-fused) 800 800 A (BS88, DIN, NFC, L, HRCI-L, nonfused) 100 100 A (Non-fused) 10 10 A (BS88, DIN, non-fused) d No. of Poles Code Description 17 -pole switch 174 c 4-pole switch (non-fused:0 10 A; fused: 0 6 A) Indication Code Configuration Blank No fuse status indication S status indication (0 6 A) d See page 9 for dimensional reference data. Non-fused disconnect switches must use separately installed fuses for upstream shortcircuit protection Does not carry UL Certification classes BS88, DIN, and NFC are not suitable for use in North American applications Fourth pole (0 6 A), additional auxiliary contacts, and handle options available in accessory section. 4 Publication 194R-SG00D-EN-P

Product Selection IEC d Disconnect Switches Cat. No. 194R-F-17 Cat. No. 194R-F6-17 Cat. No. 194R-D160-17 BS88 d Disconnect Switches Ratings (AC) With Links Load Rating I -Phase Maximum kw (0 Hz) e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 0. 11 1 BS88 A1 A1 194R-B0-17 9 18. 0 BS88 A A1 194R-B-17 6 18. 0 BS88 A B1 194R-B6-17 0 7 90 BS88, size A4 F1 194R-B0-17 160 80 1 BS88, size A4 F14 194R-B160-17 00 0 BS88, size B1-B F1 194R-B00-17 0 1 0 BS88, size B1-B F1 194R-B0-17 400 0 0 BS88, size B1- B4 F16 194R-B400-17 60 9 BS88, size C1- C F17 194R-B60-17 800 40 400 BS88, size C1-C F17 194R-B800-17 10 60 400 BS88, size D1 F18 194R-B10-17 DIN d Disconnect Switches Ratings (AC) With Links -Phase Maximum kw (0 Hz) Load Rating I e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 9 18. 0 NH 000 B1 194R-D-17 6 18. 0 NH 000 B1 194R-D6-17 1 6 90 DIN, size T00 F1 194R-D1-17 160 80 1 DIN, size T00 F1 194R-D160-17 0 1 0 DIN, size T1 F1 194R-D0-17 400 0 0 DIN, size T F16 194R-D400-17 60 9 DIN, size T F17 194R-D60-17 800 40 400 DIN, size T F17 194R-D800-17 10 60 400 DIN, size T4 F18 194R-D10-17 NFC d Disconnect Switches Ratings (AC) With Links -Phase Maximum kw (0 Hz) Load Rating I e [A] 00/0V 80/400/41V 660/690V Ref. Cat. No. 7. 11 NFC 14x1 mm A1 194R-F-17 9 18. 0 NFC 14x1 mm A1 194R-F-17 6 18. 0 NFC x8 mm B1 194R-F6-17 classes BS88, DIN, and NFC are not suitable for use in North American applications Note: Your order must include 1) Cat. No. of disconenct switch, ) shaft, ) handle, and 4) any accessories. Publication 194R-SG00D-EN-P 7

Accessories Lug Kits order separately Description Wire Size Dimension Reference For Use With Pkg. Quantity Cat. No. Multi-Tap Terminal Lugs Load side only Terminal Lug Kit () 14 4 AWG A1 (194R-C0, -J0), () 0.7 mm A (194R-N0) () 14 4 AWG B1 (194R-J60, -H0, - () 0.7 mm H60), B (194R-N60) (1) 00 MCM (1) 00 MCM (1) MCM (1) MCM () 0 MCM () 0 MCM () MCM () MCM () MCM () MCM 1 194R-0-MTL 1 194R-60-MTL switches: 0 00 A UL d switches: 00 A switches: 0 00 A UL d and nonfused switches: 400 A switches: 400 A UL d and nonfused switches: 400 A switches: 400 A switches: A UL d switches: 800 A switches: A switches: 800 100 A switches: 800 100 A 194R-TL1 4 194R-TL 194R-TL 4 194R-TL4 194R-TL 194R-TL6 194R-TL7 4 194R-TL8 6 194R-TL9 8 194R-TL Other Accessories Description Cone guide for shafts longer than 0 mm (1.6 in.) For Use With Cat. No. 194R-HM4-L, - HM4E-L, -HM4-N-L, and - HME-N-L handles Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. 1 194R-HSG Shaft Guard Provides extra protection against contact with shaft Cat. No. 194R-R1 and -R shafts A1, A, B1, B 1 194R-R1G Operating Shaft Coupler Used to extend shaft length an additional 4.7 in. Cat. No. 194R-R1 and -R shafts A1, A, B1, B 1 194R-SC1 Operating Handle Instruction Label 0 00 A disconnect switches 00 A UL d disconnect switches ALL 194R-L1 Publication 194R-SG00D-EN-P 17

Specifications d Disconnect Switches for UL Class s and CSA HRCI-J Electrical Ratings Cat. No. 194R-C0-17 194R-J0-17 194R-J60-17 CSA Type/UL Type Class CC/HRCI-MISC Class J/HRCI-J Class J/HRCI-J Maximum Cartridge Size [A] 0 0 60 Maximum Voltage AC DC [V] [V] Ampere Rating [A] 0 0 60 Maximum Short Circuit Prospective Fault Current [ka] 00 00 00 Operating Characteristics Time Delay Non-Time Non-Time Time Delay Delay Delay Time Delay Maximum Hp, -Phase AC 00V, 60 Hz 40V, 60 Hz 480V, 60 Hz V, 60 Hz Maximum Hp, 1-Phase AC 10V, 60 Hz 40V, 60 Hz Maximum Hp, DC 1V DC 0V DC Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C. No. 4, IEC 60947- and UL 98. 0.7 0 7. 0. 1. 7. 7. 1 0 0 7. 0. 1. 1 1 0 0 0 Non-Time Delay 7. 7. 1 1 1. Electrical Ratings Cat. No. 194R-J0-17 194R-J00-17 194R-J400-17 194R-J-17 194R-J800-17 CSA Type/UL Type Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Maximum Cartridge Size [A] 0 00 400 800 Maximum Voltage AC DC [V] [V] 0 Ampere Rating [A] 0 00 400 800 Maximum Short Circuit Prospective Fault Current [ka] 00 00 00 00 00 poles in series 800 0 0 0 0 18 Publication 194R-SG00D-EN-P

Specifications Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Carriers Mechanical Data Cat. No. 194R-N0-17 194R-N60-17 194R-NU0-17, 194R-NU0-174 194R-NU00-17, 194R-NU00-174 Mechanical Endurance Operations 000 000 000 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm AWG mm AWG.. #14 #8. #14 #8.. #14 #4. #14 #4 88. 00 MCM #6 88. 00 MCM #6 Maximum Number of Auxiliary Circuits 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings) kg lbs Height Width Depth 0.81 1.78 48 (9-/4) 171 (6-/4) 111 (4-/8) Non-fused disconnect switches must be used with separately installed fuses. 1.14. 48 (9-/4) 197 (7-/4) 111 (4-/8) 1.67/.1.7/4. 1.67/.1.7/4. A B F1 F1 Mechanical Data Cat. No. 194R-NU400-17, 194R-NU400-174 194R-NU-17, 194R-NU-174 194R-NU800-17, 194R-NU800-174 194R-NU100-17, 194R-NU100-174 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Carriers Mechanical Endurance Operations 6 000 6 000 00 00 Operating Torque (Maximum) Terminal Capacity Power Terminals N m lb in mm AWG 14. 18. MCM # 7 7. x MCM x # 0 44 4 x MCM 4 x # 0 44 4 x MCM 4 x # Auxiliary Contact Terminals mm AWG Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings) kg lbs Height Width Depth /.8 6.6/8.4 Non-fused disconnect switches must be used with separately installed fuses. 8./. 18.1/.7 11.6/14..6/ 11.6/14..6/ F F F4 F4 Publication 194R-SG00D-EN-P 1

Specifications Mechanical Data Cat. No. 194R-B0-17 194R-B-17 194R-B6-17 194R-B0-17 194R-B160-17 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Carriers Mechanical Endurance Operations 000 000 000 000 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm mm AWG.. #14 #8.. #14 #8.. #14 #4 Maximum Number of Auxiliary Circuits 6 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 0.8 1.84 48 (9-/4) 171 (6-/4) 148 (-1/16) 0.8 1.84 48 (9-/4) 171 (6-/4) 148 (-1/16) 1.18.60 48 (9-/4) 197 (7-/4) 148 (-1/16) 8. 9 1.88 4.7 8. 9 A1 A1 B1 F1 F14 Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-..7. Mechanical Data Cat. No. 194R-B00-17 194R-B0-17 194R-B400-17 194R-B60-17 194R-B800-17 194R-B10-17 Degree of Protection (per IEC 60947- ) Switch Only Switch with Terminal Shield & Carriers Mechanical Endurance Operations 000 000 000 8 000 000 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) N m lb in 0 0 0 mm 40 40 40 40 40 40 mm AWG kg lbs Height Width Depth 40 40 40 4 8 8 8 8 8.77 8.7.77 8.7 4.8.7 17.77 9 19.77 4.6 7 87.7 F1 F1 F16 F17 F17 F18 Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-. Publication 194R-SG00D-EN-P

Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. H M Z J Ø 0.1 Ø 1 Y X AC N1 N AA.1 80 F Cat. No. 194R-N Disconnect Switch Dimension Reference F Approximate Dimensions mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (-pole) F (4-pole) H J (-pole) J (4-pole) 460 (18.1) 80 (11) 60 (14.17) 140 (.) 17. () 167. (6.9) M (-pole) (.0) M (4-pole) N N1 AA Z (1.19) 17(6.88) 9. (.4) 0 (1.6) 47 (1.8) H Z 0.78 0 1.7 40 Ø 0.4 Ø 11 J M Y X N1 8.8 AC N N 0.78 0 4.7 10 F Cat. No. 194R-N 800 100 Disconnect Switch Dimension Reference F4 Approximate Dimensions mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (-pole) F (4-pole) H 460 (18.1) 460 (18.1) 7 (14.64) 7 (14.64) 49 (19.7) 49 (19.7) 140 (.) 140 (.) J1 (- pole) 17. (6.8) 17. (6.8) J1 (4- pole). (9.19). (9.19) M (- pole) 47 (1.66) 47 (1.66) M (4- pole) N N1 AA Z 467 (18.8) 467 (18.8) 17 (6.88) 17 (6.88) 9. (.4) 9. (.4) 8 (1.) 47 (1.8) 0 (1) 47 (1.8) Publication 194R-SG00D-EN-P 1

Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 7.08 180 4.7 111.1.19 (P) - 1.79 (4P) 9 (P) - (4P).98 1. 7.97 0. 1. 90 9.44 40.98 1..9 7 0.98 4.9.9 7.6 8 Cat. No. 194R-J400 Frame Size F7.9 66.9 66 min.4 min 6 9.84 0 6. 1.1 79..6 8. 0.4 11 fix 11.18 (P) - fix 14.88 (4P) fix 84 (P) - fix 78 (4P).6 1.4 6 4 0.7 7.4 90 0.7 7 11.81 00. 60 fix 9.84 fix 0 16. 18.4 471 14.96 80 0.7 7. 9 11.81 00.6 8. Ø 0.1 Ø1 1.7.7 94 94 14. (P) - 18.0 (4P) 64 (P) - 48 (4P) 0. 9 Cat. No. 194R-J, -J800 Frame Size F8 Publication 194R-SG00D-EN-P

Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. IP66 (Type /4/4X/1) Corrosion-Resistant, Non-Metallic Enclosure K A 6.0 (1/64) H D C K.0 (/16) A H D C F B J F B J.0 (1-1/4) G Four Slot Mounting Holes 8 x 1 (0.1 x 0.0) Cat. No. 194R-K_0P, -K60P 0 and 60 A switch.0 (1-1/4) G Four Slot Mounting Holes 8 x 1 (0.1 x 0.0) Cat. No. 194R-K_0P 0 A switch Switch Size [A] A B C D F G J K 0/60 6 (8-9/64) 67 (-1/) 16 (6-7/64) 0 (7-61/64) 78 (-61/64) 1 (6) 0 (1) 6 (1/64) Publication 194R-SG00D-EN-P 47

Description DIN s (0 A shown) Dimensions in millimeters only. Dimensions are not intended to be used for manufacturing purposes. IEC fuse type: -link with blade contacts Voltage rating: 660/690V AC Interrupting rating: 10,000 A Standard cartridge sizes: 00, 0, 1 and Typical ampere ratings: 400 A Construction: Blade type Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194RND07P, ND18P, ND0P, ND00P Where used: Europe, South America, Middle East and India Max. Rated b 1 4 Size Current [A] 1 4 (min.) d (max.) (max.) ±0. f 00 0 78. ± 1. 4 ± 1. 49 ±1. 1 ±0. 48 0 0 ± 6 1. 0 160 1 ±. 67 6 + 1. 68 +1. 1 +1. 0. 48 40 0 ± 6 11. 1 0 1 ±. 71 6 ±. 68 ±. 0. +1. 0. 0 + 6 400 ±. 7 6 ±. 68 ±.. +1. 0. 61 60 0 + 6 With Bulletin 194R d Disconnect Switches, Continued CSA HRCI and UL Class s ( A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. UL fuse type: Class CC CSA fuse type: HRCI-MISC Voltage rating: V AC Interrupting rating: 00 000 A Standard cartridge sizes: 0 A Typical ampere ratings: 1 0 A Construction: Ferrule type Can be installed on Bulletin 194R disconnect switch Cat. No: 194R-NC00P Where used: North America CSA HRCI and UL Class s (0 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCI-J UL fuse type: Class J Voltage rating: V AC Interrupting rating: 00 000 A Standard cartridge sizes: 0, 60, 0, 00, and 400 A Typical ampere ratings: 1 A; Blade type for bolted connection Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NJ00P, NJ060P, NJ0P, NJ00P, NJ400P Where used: North America 7 0 Publication 194R-SG00D-EN-P