EH-RIO IP67 Profibus-DP I/O modules

Similar documents
PROFIBUS 1732 ArmorBlock I/O, Series A

ArmorPoint I/O Field Potential Distributor, Series A

DeviceNet ArmorBlock Network Powered 16-input Module, Series A

DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module

DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A

ArmorPoint 24V dc Input Modules, Series A

DeviceNet ArmorBlock Network Powered 16-input Module

Embedded I/O Expansion Board with 10 Outputs

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

Digital ac/dc (24V) Input Module

ControlNet-to-DeviceNet Linking Device

USB-to-DeviceNet Cable

ArmorBlock 2-Port EtherNet/IP Module

CompactLogix Power Supplies Specifications

POINT I/O PROFIBUS Adapter

CompactBlock Guard I/O EtherNet/IP Safety Modules

ArmorBlock Guard I/O DeviceNet Safety Modules

Isolated 24V dc Output Module

ArmorPoint 24V dc Analog Input Modules, Series A

1756 ControlLogix Chassis Specifications

16 Input/16 Output Digital Embedded I/O Boards

Installation Instructions

ArmorPOINT I/O 5V DC Encoder/Counter Module, Series A

ArmorBlock 16-Point EtherNet/IP Module

Installation Instructions

About the PCMK/B Card

ArmorPoint 4-Channel 24V dc Analog Input Module, Series A

Installation Instructions

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Thermocouple and RTD Input Modules

Allen-Bradley 1786-RPFRXL

Installation Instructions

XM Monitoring Modules Specifications

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

P3-SCM. General Specifications

User Manual Digital Input Module

GuardPLC Digital Input/Output Module

TF501, TF521 Terminal Bases

1756 ControlLogix Chassis Specifications

TU531, TU532 Terminal Unit

POINT I/O 24V DC 4-channel Discrete Input Module with Diagnostics

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

CompactBlock LDX I/O for the DeviceNet Network

Installation Instructions

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

VersaView Industrial Non-display Computers

SLC 500 System Overview

Digital ac/dc (24V) Input Module

CM592 PROFIBUS Communication Module

SLC 500 System Overview

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

PanelView 600 Terminals

GuardPLC 1600 Controllers

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

Output Voltage* (nom.)(adjustable)

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

AO523 Analog Input Module

Differential Liquid/Gas Pressure Transmitter

Kinetix 6000 Axis Module and Shunt Module

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

Stratix 5700 Ethernet Managed Switches

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

VIBRATION MONITOR CX-RLY

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Installation Instructions

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Safety Standards. Model Number: Unit Weight:

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

Universal Power Supplies

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Kinetix 300 Memory Module Programmer

Allen-Bradley 1790D-0B16

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

CompactBlock I/O for DeviceNet Modules Series D

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

AI531 Analog Input Module

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

SLC 500 System Overview

Output Voltage* (nom.)(adjustable)

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

MGate 4101-MB-PBS Series

CI542 PROFIBUS Communication Interface Module

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Safety Standards. Model Number:

Transcription:

Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP I/O modules are stand-alone 24VDC I/O modules which are communicating via the PROFIBUS network. The sealed IP67 housing of these modules requires no enclosure. (Note that environmental requirements other than IP67 may require an additional appropriate enclosure.) I/O connectors are sealed M8 (pico) or M12 (micro) styles while the network and auxiliary power connectors are sealed M12 style. Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Hitachi Europe be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Hitachi Europe cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Hitachi Europe with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Hitachi Europe is prohibited. Throughout this manual we use notes to make you aware of safety considerations. 1

2 EH-RIO IP67 Profibus-DP I/O modules Important User Information WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION IMPORTANT Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you: identify a hazard avoid a hazard recognize the consequence Identifies information that is critical for successful application and understanding of the product. SHOCK HAZARD Labels may be located on or inside the module to alert people that dangerous voltage may be present. ATTENTION Environment and Enclosure This equipment is intended for use in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is supplied as "enclosed" equipment. It should not require additional system enclosure when used in locations consistent with the enclosure type ratings stated in the Specifications section of this publication. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings, beyond what this product provides, that are required to comply with certain product safety certifications. NOTE: See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Also, see the appropriate sections in this publication.

EH-RIO IP67 Profibus-DP I/O modules 3 ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. If available, use a static-safe workstation. When not in use, store the equipment in appropriate static-safe packaging. Install Your EH-RIO IP67 I/O Module Set the Station Address To install the module: Set the station address Mount the module Connect the cord sets Attach the network cables Communicate with the module To set the station address, adjust the switches on the front of the module. The two switches are most significant digit (MSD) and least significant digit (LSD). The switches can be set from 00 and 99. The module reads the switches at power-up only. Set Station Address This example shows the station address set at 63. 43822

4 EH-RIO IP67 Profibus-DP I/O modules Mount the Module Use the mounting holes on the module to mount the module directly to a panel or machine. Mounting holes accommodate M3 pan-head screws. The torque specification is 0.6 Nm. We recommend that you do not use the side mounting holes with this module because there is no means to ground the module. PROFIBUS Ground Bushing 37mm 17mm 179mm 168.6mm 43.3mm 32mm 43817 Front Mounting

EH-RIO IP67 Profibus-DP I/O modules 5 Mount the Module in High Vibration Areas If you will mount the module in an area that is subject to shock or vibration, we recommend that you use a flat and lock washer to mount the module. Mount the flat and lock washer as shown in the following illustration. Torque the mounting screws to 0.6 Nm. Lock Flat 43619 Connect the Input/Output Cord Sets to the EH-RIO IP67 Module The IP67 family offers 5-pin micro-style PCB mounting connectors or 3-pin pico-style PCB mounting connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cord sets you selected for your module to the appropriate ports.

6 EH-RIO IP67 Profibus-DP I/O modules Pinout diagrams for the connectors are shown below. Input Connector RIO-PBXDP8M12 5-Pin Micro-Style (12mm) Female Output Connector RIO-PBYTP8M12 Pin 1 Sensor Source Voltage Pin 2 Input B Pin 3 Return Pin 4 Input A Pin 5 Not used Input Connector RIO-PBXDP8M8 41452 3-Pin Pico-Style (8mm) Female Pin 1 Not Used Pin 2 Output B Pin 3 Return Pin 4 Output A Pin 5 Not Used Output Connector RIO-PBYTP8M8 Pin 1 Sensor Source voltage Pin 3 Return Pin 4 Input Self-configuring Connector RIO-PBXYP8M12 43583 Self-configuring Female Connectors Pin 1 Not Used Pin 3 Return Pin 4 Output Self-configuring Connector RIO-PBXYP8M8 41452 Pin 1 Sensor Source Voltage Pin 2 Input or Output B Pin 3 Return Pin 4 Input or Output A Pin 5 Not Used 43583 Pin 1 Sensor Source Voltage Pin 3 Return Pin 4 Input or Output The self-configuring modules (RIO-PBXYP8M12 and RIO-PBXYP8M8) contain both input and output functionality. If an I/O point is to be an output, dedicate that point as an output with a wired load and energize it through a control program. Energized outputs will show an associated active input, which can be used as a feedback mechanism to ensure that the output is turned on. If an I/O point is to be an input, wire the input device as normal and leave the associated output un-energized at all times. I/O Self-configuring Circuitry Turn Output On Output Circuit Scan List Device Input is on (or output is on) Input Circuit Connection Pin 43601

EH-RIO IP67 Profibus-DP I/O modules 7 Refer to the illustration below for configuration operations. PROFIBUS Node Address 4-12mm or 8-8mm I/O Connectors Status LED All I/O are 24V dc sink in/source out - 8 input - 8 output - 8 input or output points - any mix of 8 (e.g., 7 + 1; 3 + 5) Output short circuit protected Output monitoring in self-configuring style Sensor and Actuator Power 43816 IMPORTANT If the devices (sensors) connected to the input connections require Class 2 power to operate, the auxiliary power connections of this equipment must be powered by a Class 2 source. ATTENTION Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements.

8 EH-RIO IP67 Profibus-DP I/O modules Attach PROFIBUS Cables Attach the 5-pin (12mm) PROFIBUS-style connectors as shown below. PROFIBUS Input Male Connector Pin 1 +5V dc Pin 2 A Signal Pin 3 GND Pin 4 B Signal Pin 5 Shield 43584 PROFIBUS Output Female Connector 41452 Pin 1 +5V dc Pin 2 A Signal Pin 3 GND Pin 4 B Signal Pin 5 Shield To terminate the module, use the second PROFIBUS connector and a PROFIBUS terminator resistor. NOTE: Do not use PROFIBUS T connectors with these modules. Attach Auxiliary Power Cable Attach the 4-pin (12mm) micro-style connector as shown below. Pin 1 24V dc Pin 2 24V dc Pin 3 Return Pin 4 Return 43587 Input and output devices are powered through the module s I/O connectors. Removing auxiliary power will deactivate all sensors and actuators unless they are powered from a separate source. If a separate source is used, devices may still be active, even if auxiliary power is removed. To ensure that auxiliary power controls the activation/deactivation of sensors and actuators, always wire input sensors and output actuators directly to the I/O connectors. Communicate With Your EH-RIO IP67 PROFIBUS Module The EH-RIO IP67 PROFIBUS module has the following baud rates. Baud Rate Cable Length 9.6KBPS 1000m 19.2KBPS 1000m 45.45KBPS 1000m 93.75KBPS 1000m 187.5KBPS 1000m

EH-RIO IP67 Profibus-DP I/O modules 9 Baud Rate 500KBPS 1.5MBPS 3MBPS 6MBPS 12MBPS Cable Length 400m 200m 100m 100m 100m RIO-PBXYP8M12 and RIO-PBXYP8M8 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Produced 0 I7 I6 I5 I4 I3 I2 I1 I0 Consumes 0 O7 O6 O5 O4 O3 O2 O1 O0 Where: I=Input O=Output Note that the RIO-PBXYP8M12 and RIO-PBXYP8M8 self-assigning modules contain both input and output functionality. These modules do not need to be configured. If an I/O point is to be an output, dedicate that point as an output with a wired load and energize it through a control program. If an I/O point is to be an input, wire the input device as normal and leave the associated output un-energized at all times. RIO-PBXDP8M12 and RIO-PBXDP8M8 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Produced 0 I7 I6 I5 I4 I3 I2 I1 I0 Where: I=Input RIO-PBYTP8M12 and RIO-PBYTP8M8 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Consumes 0 O7 O6 O5 O4 O3 O2 O1 O0 Where: O=Output

10 EH-RIO IP67 Profibus-DP I/O modules Troubleshoot With the Indicators This module has the following indicators: Network and Module status indicator for PROFIBUS Auxiliary Power indicator Individual I/O status indicators for inputs and outputs M8 Style Connectors Module Indicator Network Indicator I/O Status Indicators 43818 Auxiliary Power Indicator M12 Style Connectors Module Indicator Network Indicator I/O Status Indicators 43816 Auxiliary Power Indicator

EH-RIO IP67 Profibus-DP I/O modules 11 The following table describes network status and module indicators. LED Is Module LED Network LED (Watchdog (WD) State & DP State) Off No module power Power Off or WD_State Flashing Green Baud rate search mode Not used WD_State Baud rate search complete and DP_State No Data Exchange mode Solid Green Module operating normal DP_State Data Exchange mode Flashing Red Minor fault: Unknown Ident_Number Solid Red Unrecoverable fault: - DPC31 ASIC fault - EEPROM Read/Write fault Auxiliary Power Indication Status None No Auxiliary Power Solid Green Auxiliary Power Present Not used Not used The following table describes the auxiliary power indicator. The following table describes individual I/O status indicators. I/O Status Indicators Function Point Indicator Status Outputs Inputs None Yellow None Yellow Output not energized Output energized No valid input Valid input Specifications Following are specifications for the EH-RIO IP67 I/O modules. PROFIBUS EH-RIO IP67 I/O modules Input Specifications Inputs Sensor Source Current, Maximum (per input) Sensor Source Current, Maximum (per module) Sensor Source Voltage (auxiliary power=12-30v dc) Maximum Minimum On-state Voltage Maximum Minimum 61131-2 Type 3 Compatible 50mA 400mA 30V 11V 30V dc 11V dc

12 EH-RIO IP67 Profibus-DP I/O modules On-state Current, Maximum 5mA PROFIBUS EH-RIO IP67 I/O modules Off-state Voltage, Maximum 5V dc Off-state Current, Maximum 1.5mA Output Specifications Outputs 61131-2 Compatible Off-state Peak Blocking Voltage, Minimum 30V On-state Voltage Drop, Maximum 0.5V On-state Current, Maximum 0.5A Off-state Leakage, Maximum 50µA Module Current, Maximum (all outputs) 4.0A Surge Current - for 10ms, repeatable every 2s, 1.2A Maximum PROFIBUS Specifications Network Protocol Redundancy Repeater Control Signal Implementation Type Freeze Mode Sync Mode Auto Baud Rate Fail Safe Mode Station Type FMS Support Number of Stations Network Length/ Communication Rate General Specifications Isolation PROFIBUS-DP (EN50170) Communication with a Class 1/Class 2 master Not supported RS485 DPC31 Supported Supported Supported Supported DP Slave Not Supported 100 maximum 9.6KBPS @ 1000m 19.2KBPS @ 1000m 45.45KBPS @ 1000m 93.75KBPS @ 1000m 187.5KBPS @ 1000m 500KBPS @ 400m 1.5MBPS @ 200m 3MBPS @ 100m 6MBPS @ 100m 12MBPS @ 100m Dimensions (Millimeters) 179H x 37W x 43.3D Indicators Module Status - red/green Network Status - red/green Auxiliary Power - green Point LED - yellow Auxiliary Voltage Maximum Minimum Auxiliary Current -RIO-PBXDP8, Maximum -RIO-PBYTP8, Maximum -RIO-PBXYP8, Maximum Operating Temperature Type tested to 500V ac for 60 seconds between auxiliary power and network (I/O to logic) 30V dc 11V dc 550mA 4A 4A IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20 to 60 C (-4 to 140 F)

EH-RIO IP67 Profibus-DP I/O modules 13 General Specifications (continued) Storage Temperature Relative Humidity Shock Vibration IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock): -45 to 85 C (-49 to 185 F) IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat): 5-95% non-condensing IEC60068-2-27 (Test Ea, Unpackaged Shock): Operating 30g Non-operating 50g IEC60068-2-6 (Test Fc, Operating): 5g @ 10-500Hz Conductor Category 2 ESD Immunity IEC 61000-4-2: 6kV contact discharges 8kV air discharges Radiated RF Immunity IEC 61000-4-3: 10V/m with 1kHz sine-wave 80%AM from 30MHz to 2000MHz 10V/m with 200Hz 50% Pulse 100%AM at 900Mhz 10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz EFT/B Immunity IEC 61000-4-4: ±2kV at 5kHz on signal ports ±2kV at 5kHz on communications ports ±4kV at 5.0kHz on power ports Surge Transient Immunity IEC 61000-4-5: ±1kV line-line(dm) and ±2kV line-earth(cm) on signal ports ±1kV line-line(dm) and ±2kV line-earth(cm) on power ports ±2kV line-earth(cm) on shielded ports Conducted RF Immunity IEC 61000-4-6: 10Vrms with 1kHz sine-wave 80%AM from 150kHz to 80MHz Emissions CSPR 11: Group 1, Class A Enclosure Meets IP65/66/67 (when marked) Weight 0.216 kg Certifications: (when product is marked) c-ul-us CE C-Tick UL Listed Industrial Control Equipment, certified for US and Canada European Union 89/336/EEC EMC Directive, compliant with: EN 61000-6-4; Industrial Emissions EN 50082-2; Industrial Immunity EN 61326; Meas./Control/Lab. Industrial Requirements EN 61000-6-2; Industrial Immunity Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions

14 EH-RIO IP67 Profibus-DP I/O modules Copyright 2005 Hitachi Europe. All rights reserved.