CPU Module IC200CPU005

Similar documents
CPU Modules CPU001 and CPU002

VersaMax* CPU Modules CPU001 and CPU002

CPU Module IC200CPU005

CPU Modules CPU001 and CPU002

Product Information. Firmware Version 3.00 Programmer Compatibility Expansion I/O Compatibility

Product Information. Firmware Version 3.10 Programmer Compatibility Expansion I/O Compatibility

CPU with Embedded Ethernet Interface

VersaMax* Serial Communications Module

VersaMax* PROFIBUS Network Interface Unit

GE Fanuc IC695CMM004. Rx3i PacSystem

VersaMax Genius Network Interface Unit

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC695CMM002 and IC695CMM004

VersaMax* DeviceNet Network Master/Slave

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

VersaMax* Analog Input, 16-Bit Thermocouple Module

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Analog Input, 16-Bit Thermocouple Module

IMPORTANT PRODUCT INFORMATION

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

PACSystems* RX3i IC694ALG233

GE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

PACSystems* RX3i IC694ALG232

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

PACSystems* RX3i CEP IC695CEP001

Important Product Information

PACSystems RX3i IC695CPU310. Features. Ordering Information. Central Processing Unit. GFK-2329T December 18, 2007

Shown with terminal block Supports diagnostic point fault contacts in the logic program

VersaMax* IC200PNS001, IC200PNS002

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

PAC BI-DP BIM and 8701-CA-BI Carrier

Accessories IC690ACC900

READ THIS INFORMATION FIRST. IC693CPU374 CPU Module with Ethernet Interface

PACSystems RX7i IC698CHS009/119

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

PACSystems RX3i IC695PSA140

IC693 PLC IC693ACC350, IC693ACC340/341

Instructions to printer DO NOT PRINT THIS PAGE

PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PBM300

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

PACSystems* RSTi-EP EPSCPE115 Standalone CPU Quick Start Guide GFK-3039 April 2018

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

MGate 5105-MB-EIP Quick Installation Guide

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

MGate 5111 Quick Installation Guide

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

GE Fanuc Automation. Programmable Control Products. VersaMax PLC. User's Manual. GFK-1503C March FANUC Replacements

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PM Series Power Meter

IMPORTANT PRODUCT INFORMATION

General Specifications. P2-SCM Serial Communications

This Datasheet for the IC693ACC301. Replacement Battery, CPU & PCM (qty 1)

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

EX-RC1 Remote I/O Adapter

PACSystems* RSTi-EP EPSCPE100 Standalone CPU Quick Start Guide GFK-3012C April 2018

RSTI-EP Slice I/O. Digital Output Module

This Datasheet is for the IC693ACC301. Backup Battery for RAM Memory.

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

P3-SCM. General Specifications

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

IMPORTANT PRODUCT INFORMATION

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Quick Start Installation Guide

A PACSystems RX3i Ethernet NIU I/O Station

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

GE Intelligent Platforms

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

PACSystems* RX3i IC695PSA140

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

EX-RC1 Remote I/O Adapter

F1000 User's Manual. (Version: V1.01)

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

P USB 2.0 (Type B) Port - Programming - Online monitoring

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

T1K MODBUS Base Controller Specifications

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PACSystems RX3i IC695HSC304 and IC695HSC308

Optional Accessories 6 2

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

VersaMax Micro and Nano Technical Product Presentation

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

EX-RC1 Remote I/O Adapter

GE Fanuc IC695ALG708. Rx3i PacSystem

Transcription:

December 0 GFK-0J PWR PORT PORT RS RS Features Supports up to 6 modules with up to 0 I/O points Can be either autoconfigured or configured from a programmer using configuration software KB of configurable memory for the application program, hardware configuration, registers (%R), analog inputs (%AI), and analog outputs (%AQ) Programming in Ladder Diagram and Instruction List Non-volatile flash memory for program storage Battery backup for program, data, and time of day clock Super capacitor provides power to memory for hour Over hour, backup battery protects memory contents up to 6 months. Backup battery has shelf life of years when not in use. Run/Stop switch Floating point (real) data functions Supports EZ Program Store device (IC00ACC00) 70mm height when mounted on DIN rail with power supply Specifications Size Program storage Backplane current consumption with no serial port converter or EZ Program Store device Backplane current consumption with serial port converter or EZ Program Store device Floating point Boolean execution speed Realtime clock accuracy (for timer functions) Time of day clock accuracy Embedded communications Configurable memory Width:.0 (06.7mm) along DIN rail Length:.0 (mm) Depth:.7: (69.mm) System flash, battery-backed RAM V output: ma.v output: 00mA V output: ma yes 0. ms/k (typical) 00ppm (0.0%) or +/- 9sec/day ppm (0.00%) or +/- sec/day @ 0C. 00ppm (0.0%) or +/- 9sec/day @ full temperature range RS-, RS- K bytes maximum Product Revision History Rev Date / Features CPU00-GG Dec. 0 Firmware revision.7 Hardware and firmware update to address component obsolescence issue. Also provides new features and resolves issues described on page. CPU00-FF CPU00-EF CPU00-DF April 0 Label change. No changes to compatibility, functions or performance. Mar. 00 Changed manufacturing location. No changes to compatibility, functions or performance. Oct. 00 Updated Power Supply signal circuit. CPU00-CF Jan. 006 Firmware revision. For details, refer to GFK-0E. CPU00-CE Jun. 00 Firmware revision. For details, refer to GFK-0D. CPU00-BD Jan. 00 ATEX approval for Class, category applications. CPU00-AD Mar. 00 Firmware revision. Support for Modbus RTU Master CPU00-AC Not released Firmware revision.0 CPU00-AB Mar. 00 Firmware revision.0 Added new serial I/O baud rates CPU00-AA Mar. 00 Firmware revision.0 Initial Product Release This release replaces all previous versions. If you need to determine the current firmware version of a CPU, see the steps below: With Machine Edition Logic Developer, go online to the CPU, then select Target > Online Commands > Show Status. The Device Information Software Revision shows the current firmware revision level. With a VersaPro or Control programmer, attach the CPU. Under the PLC menu (VersaPro) or the Comm menu (Control), select the Memory tab on the Status Information dialog. A firmware upgrade is optional. Upgrading of versions xe and earlier is recommended for applications requiring K bytes of configurable memory or -bit Modbus register data, or that use PID function blocks or serial communications. An upgrade can be ordered from the factory (A766-G06), or downloaded from www.ge-ip.com/support. The firmware resides in FLASH memory, and is upgraded by serial download from a Windows PC via CPU port. Port cannot be used for firmware upgrades. Compatibility Programmer Compatibility: Expansion I/O Compatibility: VersaPro software version.0 or later, and Machine Edition Logic Developer. All types of I/O and communications modules can be used in expansion racks. Some analog modules require specific module revisions in expansion racks, as listed below: Module Module Revision *ALG0 B or later *ALG B or later *ALG B or later *ALG0 C or later *ALG C or later *ALG B or later

December 0 GFK-0J Problems Resolved in Release.7 Port lockup during SNPX communication with radio modems Port lockup during the Modbus RTU communication with radio modems Problem with TOD clock, which caused acontroller CPU Hardware failure In SNPX protocol, while communicating through modems (dial-up modems, switched carrier radio modems and packet oriented radio modems) and VersaMax PLC is configured as Slave, if the communication between Master and Slave fails, the Slave will not respond to subsequent commands from the Master, even after communication is reestablished. A power cycle of the Slave PLC was required to restore the communication. This issue is resolved in release.7. In RTU communication, when any delay is introduced between two characters of a frame causing a break in frame, then the RTU Master port may lockup. This issue is resolved in release.7. Invalid month value input for Time of Day clock is accepted by PLC. This issue is resolved in release.7. New Features and Enhancements in Release.7 Configuration for Receive to Transmit delay in RTU Master Configuration COMMREQ Configuration for End of Frame timeout in RTU Slave Configuration COMMREQ Applies to RTU Master only. This configuration allows the user to select receive to transmit delay for Master. The device will force this delay after the last byte is received or last frame is transmitted out of current port. Receive to transmit delay configuration is not linked to End of Frame timeout. The user has to take care of inter-operability of these configurations. Receive to transmit delay can be configured in Word of the RTU Master Configuration COMMREQ. This is an -bit configuration with 0 millisecond units. The value range is 0 to. The default value is 0, which configures this delay as. character times at the current baud rate. Applies to RTU Slave only. This feature allows the user to configure end of frame timeout in RTU Slave configuration COMMREQ. This configuration can be set in Word 9 of the RTU Slave Configuration COMMREQ. This is a 6-bit configuration with unit of 00 microsecond and range from 0 to 6. The default value is 0, which configures this delay as. character times at the current baud rate. The minimum value for this configuration is -character times at the current baud rate. Smart recognition of End of Frame by calculating expected number of bytes Different Error Code for Incomplete Frame & CRC Error Applies to RTU Master & Slave. This feature allows the device operating as either RTU Master or Slave, to ignore spurious data appended to any valid RTU message. The RTU Master will compare the received bytes with the expected number of bytes. The expected number of bytes in the Master is calculated while the COMMREQ information is processed to create the query. The RTU Slave determines the message length by examining the Function code in the query message during reception. The Slave determines the expected query message length after receiving at least two characters and no more than seven characters of the message. Applies to RTU Master only. If the Master receives the incomplete frame and the CRC is invalid, the error code 0607H is returned as a status. Operating Notes/Restrictions. When a serial port is configured for either Modbus RTU (Slave or Master) or Serial I/O, and a parity, framing or over-run error occurs while a serial message is being received, the next message received is ignored.. When a serial port is configured for Modbus RTU Slave, an SNP Master device (for example, a serial programmer or HMI/SCADA device that uses the SNP protocol) may attach to the port. If the SNP device is disconnected and then an RTU query is sent to the port before 0 seconds have elapsed, the port is unable to receive any serial messages. To recover, power to the CPU must be turned off and then on.. When a serial port is configured for Serial I/O, and a new hardware configuration is stored that changes the port protocol to SNP, the port may not respond to SNP Attach messages until the CPU is powered off and then on.. In series 90-0 CPUs, the Shift Register Bit (SHIFR_BIT) instruction may be used to rotate a bit sequence around a range of discrete references by specifying the same reference for the output, Q, and the start reference, ST. However, in VersaMax CPUs, separate references must be used for ST and Q, and additional logic must be used to copy the output bit from the Q reference to the ST reference.. When the configured size of a reference table is changed after the table is stored to flash memory, and the user attempts to read Initial/Forced Values from flash memory, the table will be filled with zeros. 6. Using an older revision non-intelligent analog module in an expansion rack will cause a System Configuration Mismatch error to be logged. The faulted module must be replaced with a newer revision before it will be scanned. The allowed revisions are detailed under Compatibility, in the Product Information section, above. Changing an IND or ISA PID function block integral rate parameter value from (that is, from 0.00 repeats/sec.) to 0 or from 0 to causes a step change in both the integral term and the control variable (CV) output. This result is expected. A zero integral rate value specifies that the integral term contribution to CV is zero, while a non-zero value specifies a non-zero contribution.

December 0 GFK-0J. If the receiver in a local single rack is powered off while the CPU is powered on, erroneous Addition of rack faults may be logged by the CPU. It is recommended that both the CPU and the receiver be powered by a single source. 9. Occasionally, a "Backplane Communication Fault" may be logged on an intelligent I/O module after power-cycling the main or expansion rack. This is a diagnostic fault that can be cleared. 0. In very rare instances, when field power is lost on one module, non-intelligent modules in the same rack may also report faults.. In very rare instances, a module being hot inserted may not be added by the CPU. It will not generate an Addition of Module fault and the module will not be scanned. The situation can be corrected by extracting and re-inserting the module.. The SHIFR_BIT Instruction behaves differently in VersaMax and Series 90-0 CPUs. In series 90-0 CPUs, the Shift Register Bit (SHIFR_BIT) instruction may be used to rotate a bit sequence around a range of discrete references by specifying the same reference for the output, Q, and the start reference, ST. This capability may be used, for example, to control the repetition of a fixed sequence of actions. In this example, each of the discrete references in the range of the SHIFR_BIT instruction would be used as the permissive contact for one of the repeated actions. In VersaMax CPUs, the SHIFR_BIT instruction does not operate as expected when the same reference is used for both ST and Q. Instead, separate references must be used, and additional logic must be provided to copy the output bit from the Q reference to the ST reference.. When the configured size of a reference table is changed after the table is stored to flash memory, and the user attempts to read Initial/Forced Values from flash memory, the table will be filled with zeros. Module Installation This equipment may be mounted on a horizontal or vertical DIN rail. If mounted on a vertical DIN rail, the CPU module must be located at the bottom. Rated thermal specifications for the CPU module are based on a clearance of above and below the equipment and to the left of the CPU module.. Allow sufficient finger clearance for opening CPU door.. Allow adequate clearance for serial port cables.. Allow adequate space for power wiring. The CPU with power supply attached fits into a 70mm deep enclosure. Installation in Hazardous Areas EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS I, DIVISION, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION ; WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. Installing the CPU on the DIN Rail The CPU and connecting carriers must be installed on the same section of mm x 7.mm DIN rail, mm thick. Steel DIN rail is recommended. The DIN rail must be electrically grounded to provide EMC protection. The rail must have a conductive (unpainted) corrosionresistant finish. DIN rails compliant with DIN EN00 are preferred. For best stability, the DIN rail should be installed on a panel using screws spaced approximately 6 inches (.cm) apart. The CPU snaps easily onto the DIN rail. No tools are required for mounting or grounding to the DIN rail. Before joining module carriers to the CPU, remove the connector cover on the right-hand side of the CPU. Do not discard this cover, you will need to install it on the last carrier, to protect the connector pins from contamination and damage during use. Install each carrier close to the previously-installed carrier, then slide the properly-aligned carriers together, joining the mating connectors firmly. To avoid damaging the connector pins, do not force or slam carriers together. DIN-rail clamps should be installed at both ends of the station to lock the modules in position. Install the connector cover that was removed over the connector on the last carrier to protect the connector pins and to provide compliance with standards. Panel-Mounting If excessive vibration is a factor the CPU and carriers should also be screwed down to the mounting panel. Note. Tolerances are +/- 0.mm (0.00in) non-cumulative. Note..-.Nm (0- in/lbs) of torque should be applied to M. (#6- ) steel screw threaded into material containing internal threads and having a minimum thickness of.mm (0.09in)..mm 0.00in.mm 0.70in.mm 0.70in TAPPED HOLE IN PANEL SEE NOTE. M. (#6) SCREW SPLIT LOCK WASHER FLAT WASHER.9mm 0.6in REF CPU

December 0 GFK-0J Removing the CPU from the DIN Rail. Turn off power to the power supply.. (If the CPU is attached to the panel with a screw) remove the power supply module. Remove the panel-mount screw.. Slide the CPU away from the other modules until the connector on the right side disengages from the next carrier.. With a small flathead screwdriver, pull the DIN rail latch outward while tilting the other end of the module down to disengage it from the DIN rail. Activating or Replacing the Backup Battery The CPU is shipped with a battery already installed. The battery holder is located in the top side of the CPU module. Before the first use, activate the battery by pulling and removing the insulator tab. To replace the battery, use a small screwdriver to gently pry open the battery holder. Replace battery only with*acc00 from your PLC supplier, or with Panasonic battery: BR0. Use of another battery may present a risk of fire or explosion. Caution Battery may explode if mistreated. Do not recharge, disassemble, heat above 00 deg. C ( deg. F) or incinerate. Observing the Module LEDs PWR PORT POWE R PORT The LEDs in the upper left corner indicate the presence of power and show the operating mode and status of the CPU. ON when the CPU is receiving V power from the power supply. Does not indicate the status of the.v power output. ON indicates the CPU has passed its powerup diagnostics and is functioning properly. OFF indicates a CPU problem. Fast blinking indicates that the CPU is running its powerup diagnostics. Slow blinking indicates the CPU is configuring I/O modules. (Simultaneous blinking of this LED and the green Run LED indicates that the CPU is in boot mode and is waiting for a firmware update through port.) Green when the CPU is in Run mode. Amber when the CPU is in Stop/IO Scan mode. If this LED is OFF but is ON, the CPU is in Stop/No IO Scan mode. If this LED is flashing green and the Fault LED is ON, the module switch was moved from Stop to Run mode while a fatal fault existed. Toggling the switch will continue to Run mode. ON if the CPU is in Stop/Faulted mode because a fatal fault has occurred. To turn off the Fault LED, clear both the I/O Fault Table and the PLC Fault Table. If this LED is blinking and the LED is OFF a fatal fault was detected during PLC powerup diagnostics. Contact Technical Support. ON if an override is active on a bit reference. Blinking indicates activity on that port. Switching the PLC Operating Mode The CPU Run/Stop mode switch is located behind the module door. This switch can be used to place the CPU in Stop or Run mode. It can also be used to block accidental writing to CPU memory and forcing or overriding discrete data. Use of this feature is configurable. The default configuration enables Run/Stop mode selection and disables memory protection. /ON STOP/OFF If Run/Stop mode switch operation is enabled, the switch can be used to place the CPU in Run mode. If the CPU has non-fatal faults and is not in Stop/Fault mode, placing the switch in Run position causes the CPU to go to Run mode. Faults are NOT cleared. If the CPU has fatal faults and is in Stop/Fault mode, placing the switch in Run position causes the Run LED to blink for seconds. While the Run LED is blinking, the CPU switch can be used to clear the fault table and put the CPU in Run mode. After the switch has been in Run position for at least ½ second, move it to Stop position for at least ½ second. Then move it back to Run position. The faults are cleared and the CPU goes to Run mode. The LED stops blinking and stays on. This can be repeated if necessary. If the switch is not toggled, after seconds the Run LED goes off and the CPU remains in Stop/Fault mode. Faults stay in the fault table. Using the CPU Serial Ports The CPU s two serial ports are software-configurable for SNP Slave, RTU Slave or Serial I/O operation. If a port is being used for RTU, it automatically switches to SNP Slave mode if necessary. Both ports default configuration is SNP Slave mode. If configured for Serial I/O, a port automatically reverts to SNP Slave when the CPU is in Stop mode. When the port reverts back to SNP Slave, the same serial communications parameters as the currently-active Serial I/O protocol are used. Therefore the programmer must use the same parameters for it to be recognized. If any parameter values associated with Serial I/O protocol are not supported by SNP Slave protocol, the programmer will not be able to communicate with the PLC via that port. An external device can obtain power from Port if it requires 00mA or less at VDC. PORT RS RS Port is an RS- port with a 9-pin female D-sub connector. The pinout of port allows a simple, straightthrough cable to connect with a standard AT-style RS- port. Cable shielding attaches to the shell. Port screw locks are threaded #-0. Port is an RS- port with a -pin female D-sub connector. This can be attached directly to an RS- to RS- adapter (IC690ACC90). Port can be used for program, configuration, and table updates with the EZ Program Store module. Port screw locks are threaded (metric) Mx0.).

December 0 GFK-0J Pin Assignments for Port Pin Signal Direction Function n/c TXD Output Transmit Data output RXD Input Receive Data input n/c GND 0V/GND signal reference 6 n/c 7 CTS Input Clear to Send input RTS Output Request to Send output 9 n/c Shell SHLD Cable Shield wire connection / 00% (Continuous) shielding cable shield connection Cable Diagram for Attachment to a PC 6 7 9 6 7 9 PC 9-Pin CPU Serial Port Port 9-pin female 9-pin male () RXD () TXD () TXD () RXD () GND () GND (7) RTS (7) CTS () CTS () RTS The shield must attach to shell of connectors on both ends of the cable. and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden 960 9 Pin Male : Shell: Computer cable, overall braid over foil shield conductor 0 Volt / 0C (76F) AWG tinned copper, 7x stranding Type: Crimp Solder Vendor: Plug: DEA9PK7F0 00- ZDE9P 7790- Pin: 00-7-07 6606-9 Kit* ITT Cannon DE07- [9-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 0 cable exit design to maintain low-profile installation Plus ITT Cannon 0-0-00 [Extended Jackscrew]: Threaded with #-0 for secure attachment to port Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. * Use of this kit maintains the 70mm installed depth. Pin Assignments for Port Pin Signal Direction Function SHLD Cable Shield Drain wire connection,, n/c PV Output +.VDC to power external level converters (00mA max.) 6 RTSA Output Request to Send (A) output 7 GND 0V/GND reference signal CTSB Input Clear to Send (B) input 9 RT Resistor Termination (0 ohm) for RDA 0 RDA Input Receive Data (A) input RDB Input Receive Data (B) input SDA Output Transmit Data (A) output SDB Output Transmit Data (B) output RTSB Output Request to Send (B) output CTSA Input Clear to Send (A) input Shell SHLD Cable Shield wire connection / 00% (Continuous) shielding cable shield connection and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden 0 Pin Male : Shell: Low Capacitance Computer cable, overall braid over foil shield Twisted-pairs Shield Drain Wire 0 Volt / 0C (76F) AWG tinned copper, 7x stranding Velocity of Propagation = 7% Nominal Impedance = 00 Type: Crimp Solder Vendor: Plug: DAAPK7F0 006- ZDAP 7790- Pin: 00-7-07 6606-9 Kit* ITT Cannon DA07-0 [-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 0 cable exit design to maintain low-profile installation Plus ITT Cannon 0-0-009 [Extended Jackscrew]: Threaded with (metric) Mx0. for secure attachment Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. * Use of this kit maintains the 70mm installed depth. Cable Lengths Maximum cable lengths the total number of feet from the CPU to the last device attached to the cable are: Port (RS-) = meters (0 ft.) Port (RS-) = 00 meters (000 ft.) Serial Port Baud Rates RTU protocol 00, 00, 00, 9600, 9.K,.*K, 7.6*K Serial I/O protocol 00, 00, 00, 9600, 9.K,.K*, 7.6K* Port Port 00, 00, 00, 9600, 9.K,.*K, 7.6*K 00, 00, 00, 9600, 9.K,.K*, 7.6K* SNP protocol 00, 9600, 9.K,.K* 00, 9600, 9.K,.K* Only available on one port at a time.