EL-ST100 KEYPAD CONTROLLER

Similar documents
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Waterproof. Keypad/Reader/Controller

Digital Keypad Introduction

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

W3-M. Metal waterproof standalone access control/reader. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Single Door Standalone Access Control User Manual

DOLXFD1000B. Waterproof Access Control/Reader

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

W3-H Waterproof Keypad/Reader/Controller

User Manual. PCKeypad Wireless Keypad

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Fingerprint Access Control F1. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

REX F-0-9 Standalone or Access Controller

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

VIDI-AC-2CS Access Controller/ Reader

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

BC Digital Keypad. User Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Stand-alone Proximity Access Control

VIS-3200 / VIS-3201 User Manual

RBR-SB-KTZ001 LAR 2. User Manual

Fingerprint Identification Proximity Reader. Quick Installation Guide

Specifications: Features:

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

User Manual. Split access control with intelligent secured power supply.

Installation and User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

UC-2000 Installation Manual Unicorn Computers Technology Limited

CV-945 Stand-Alone Biometric Reader. Installation Instructions

FTK5 PROXIMITY KEYPAD

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

MS-5000: MiniStar Reader

GV-Card Reader. User s Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

MS-7000: SuperStar Reader

1. Product Specification

Installation & User Manual V1.0

Installation Instructions

ACCESS CONTROL SYSTEM

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

7612 Programming Instructions

IBA-7612 Programming Instructions

ACTsmart2 Product Range Operating and Installation Instructions

HSY-S209 EM Metal waterproof access control system User Manual

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

PR602LCD v1.0 Installer Manual Rev. A

CP150B Vandal & Weather Resistant Keypad Security Systems

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

MS-3000 MicroStar Reader

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Key Switch. Document version: 1.5 (Updated 02 May 2017)

EX8. User Manual. Ver 1.0

AS Keypad User Manual

Installing Keypad and Backplate

Pyramid Series Proximity Readers

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Standalone Access Control

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

B100-SA Standalone Biometric Reader

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

KP2000E/EM Series Style Keypad

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

GV-RK1352 and GV-R1352 Card Reader

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

GV-AS Controller. Installation Guide

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Two Door Controller GEN-045

DG Series. Access Control Proximity Readers DG-160 DG-800

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

CM-500 SK 500 USER CODES KEYPAD

Connecting a Cisco Reader Module

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

2000 Series e/em Style Keypad Installation and Programming Manual

MS-4000: ShootingStar Reader

Fast operation of IP Villa System V 1.0

232iLM Keypad Installation and Programming Instructions

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Installers & User guide Smart Mortise.

Installation guide for PR602LCD type access controller

Installers & User guide Smart Mortise.

CC Series metal access control Manual

Transcription:

WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6 To prevent this device damaged by back EMF, connect 1N4004 or similar diode in parallel to power terminals of the lock as close as possible.

QUICK REFERENCE 1) Change Access Setting a) * # 333333 [short beep], 01 ( Card + Pin ) [long beep], * b) * # 333333 [short beep], 02 ( Card or Pin ) [long beep], * c) * # 333333 [short beep], 03 ( Card only ) [long beep], * d) * # 333333 [short beep], 04 ( Pin only ) [long beep], * 2) Add New Card * # 333333 [short beep], 06 [ short beep ], show card [long beep], * 3) Delete Card * # 333333 [short beep], 07 [ short beep ], show card [long beep], * 4) Delete card & user ( all code ) * # 333333 [short beep], 08 [ long beep ], * 5) Electric Magnetic Lock Time Setting * # 333333 [short beep], 09 [ short beep ], ( 00~60) [long beep ], * 6) Door Open Time Setting * # 333333 [short beep], 10 [ short beep ], ( 00~99) [long beep ], * 7) Security Setting a) * # 333333 [short beep], 11 [short beep ], 0 [long beep], * DISABLE b) * # 333333 [short beep], 11 [short beep ], 1 [long beep], * ENABLE 8) Change Master Code * # 333333 [short beep], 12 [ short beep ], New code, New code [long beep] * 9) User Pin Code - 10 user code * # 333333 [short beep], 13 ~ 22 [ short beep ], 4 New code [long beep] * 10) Delete User Pin Code - 10 user code * # 333333 [short beep], 13 ~ 22 [ short beep ], 0000 [long beep] * 11) Reset to Factory Mode Step1) Turn Off Power, Press & hold * # Step2) Turn On Power, release * # after 5 second. DESCRIPTION Standalone device - Ideal for single door system, controlling electric lock, security system Verify via password and/or card - Four types of verification mode for greater security Weatherproof design - Water resists ability, suitable for indoor or outdoor Anti-card collision function - Free from double read situation LEDs and electronic buzzer - Provides positives audio-visual feedback to user operations EM Proximity card compatible Exceptional level of detection capability, high reliability, consistent readrange and stability SPECIFICATION Reading range Up to 2 (50mm) Input voltage 9 ~ 16VDC, 12VDC (Recommended) Current consumption 65 ~ 115mA Data format Wiegand 26 bits Carrier frequency 125KHz LED indicator Red and green Relays 2 x 12VDC, 2A ; N.C or N.O Dimension 135 x 28 x 72 mm Unit weight 0.20KG Operating temperature 0 C ~ 66 C NOTE : The specifications are subjected to change without prior notice. APPLICATIONS Single door access control system Personal identification Parking system Security system Terminal system DATA CONNECTION Color Code Name Description Shielded lead-out Gnd1 (-)12VDC Red 12V (+)12VDC Brown Gnd2 Exit Button COM Orange PBt Exit Button N.O Black Gnd3 Door Sensor COM White DrSs Door Sensor N.C Green DrCOM Door Control Relay COM Yellow DrNC Door Control Relay N.C

Blue DrNO Door Control Relay N.O Gray AlmNC Anti-tamper N.C PINk AlmCOM Anti-tamper COM Purple AlmNO Anti-tamper N.O POWER light (Red) STATUS light (Green) FEATURES Mounting : Unobtrusive design for easy installation; can be mounted directly onto metallic or wooden door frame. Audiovisual Indication : Red and Green LED for status indication. Beeper will sound when card presents or the access is granted. Safety : Built in power circuit protection and watchdog function. Indoor / Outdoor design : Sealed with water resistance, weatherized polycarbonate enclosure designed to withstand harsh environments, providing reliable performance and a high degree of vandal resistance. 4 types of door operation mode : Card and PIN mode, Card or PIN mode, Card mode and PIN mode. Proximity card : Support most of the ISO 125KHz proximity card, thin card with 0.8mm, thick card with 1.8mm or keyfob. User PIN : Provided 10 sets of door opening password when user sets the operation mode to Card and/or PIN mode or PIN mode. Maximum card storage : 1,000 cards can be stored or erased from the controller nonvolatile memory. Security Lockout : When security lockout function enabled under Card and PIN mode, user will be blocked if keys-in password wrongly for three times. FRONT PANEL 1. Indicator lights : STATUS light (Green) Door access granted or under programming mode POWER light (Red) Flashing during system operating 2. Ten enter keys, two functional keys : # key Master password starting key. * key Clear or escape key. Clear or escape NOTE: The receiving antenna is hidden behind the keypad. Therefore, the best reading range for the proximity card is located at the center of keypad. MODES & FUNCTIONS SETTING To enter programming mode, press master password #333333 (default master password). A beep sound will be heard and STATUS light turns on once the user enters programming mode successfully. User can leave programming mode by pressing a * key. Else, the device will stay in programming mode after each setting. If user does not press any key for 10 seconds, the device will leave programming mode automatically. 1. Operating Mode Setting Master password starting key By default, the device is set to operate under Card or PIN mode, which is 02. To change the operating mode, press master password and follow by pressing 01 : Operating under Card and PIN mode. 02 : Operating under Card or PIN mode. 03 : Operating under Card mode. 04 : Operating under PIN mode.

2. Lockout function Setting To enter lockout function setting, press master password and follow by 05. Press 0 to disable lockout function and press 1 to enable the function. When lockout function is enabled and operation mode set to Card and PIN mode, user who keys-in password wrongly for three times will be blocked. In order to reuse the same identity, user has to delete the card and reinstall it again. For batch registration, user can register multiple cards in series by keypad entry. First, key-in 6-digits proximity card number, then follow by 4-digits quantities number. Example: To install 10pcs proximity cards, user has to press master password, then follow by pressing 06. Next, key-in 6-digits proximity card number, eg.081433 and follow by 0010 (for 10pcs) or 0100 (for 100pcs). The device will register 10pcs proximity cards automatically after a long beep sound. Batch registration does not supported by card scanning method. 4. Card deleting function To delete a proximity card, press master password and follow by pressing 07, a beep sound will be heard once enter the function. User will hear long beep sound after key-in card number or after card scanning. 3. Card registering function To register a proximity card, press master password and follow by pressing 06. User can either register the card by card scanning or keypad entry. A. Card scanning After master password granted and enter card registering function, present the proximity card within the reading range. To add another card, just present another new card without exit this function. 5. User database clearing function To clear the whole user database, press master password and follow by pressing 08. After a long beep sound, the user database has been deleted successfully. B. Keypad entry After master password granted and enter card registering function, key-in 6-digits proximity card number, follow by card quantity of 1pc, 0001. 6. Door Parameter Setting By default, the lock release time is 5 seconds and the door open time is 10 seconds.

A. Lock Release Time Press master password and follow by pressing 09. User has to key-in a value from 00 to 60 for lock release time 9. User PIN setting B. Door Open Time Press master password and follow by pressing 10. User has to key-in a value from 00 to 99 for door open time. There are 10 sets of user PINs, start from location 13 to 22. To set the user PIN, press master password and follow by pressing 13 for the first set. After a short beep sound, user has to key-in a new 4-digits user PIN. While press 14 for second user PIN, and so for the rest of the user PIN. 7. Security function This function is to release the electric locking for permanently during certain occasion. To enable/disable the security function, press master password and follow by pressing 11. After a short beep sound and the STATUS light turns on, press 1 to enable or press 0 to disable the security function. The lock releases and the STATUS light turns on infinitely until user disables it. 10. User PIN deletion To delete the user PIN, press master password and follow by pressing 13 for the first set, 14 for second set and so on. After a short beep sound, key-in 0000. 0000 11. Cold Start 8. Master password setting To change the master password, press master password and follow by pressing 12. After a short beep sound, user has to key-in the new password. After a long beep sound, user has to key-in that password again for verification. It will be a long beep sound again to indicate the password changed successfully. Cold Start is a process to clear database, reset or refresh the program/parameter to initial state. To perform a Cold Start, user need to hold down * and # together, switch off and on the power supply. Releases both button after user hears the continuous beep sound and switch off the unit again. NOTE: Cold Start will erase the whole data entry in the EEPROM! Please be aware when perform it. It is advised to perform this when system is crashed.

INSTALLATION INSTRUCTION B A C 1. Using a screwdriver towards the bottom of the reader s case as shown at A. Then push the screwdriver lightly upward. 2. After loosing the reader s case, pull the upper case up to release as shown at B. 3. Please select an appropriate position to fit the unit. Then use two screws (C) to tighten the unit to the position drilled. 4. Mount the upper cover back to the unit by pushing the cover toward the unit.