SANnet II Manual Firmware Upgrade and Controller Recovery Step Guide - From 3.2x to 4.1x Guide

Similar documents
Sun StorEdge 3510 FC Array and 3511 SATA Array Controller Module Replacement Guide

July , Revision C. SANnet II 200 FC and SATA Array Best Practices Manual

RAID Incorporated. Generic Operation Manual

Upgrading R/Evolution Storage Systems

Configuring Host Router and Cisco Analog Video Gateway Module Interfaces

User Guide. Storage Executive Command Line Interface. Introduction. Storage Executive Command Line Interface User Guide Introduction

March , Revision F. SANnet II Family FRU Installation Guide

WLM1200-RMTS User s Guide

Storage Profiles. Storage Profiles. Storage Profiles, page 12

DtS Data Migration to the MSA1000

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

3ware Release Notes Supporting 9690SA and 9650SE controllers

Release Notes for (Supporting 3ware 9690SA and 9650SE controllers)

HP Supporting the HP ProLiant Storage Server Product Family.

This option lets you reset the password that you use to log in if you do not remember it. To change the password,

Maintaining the System Software

Serial Number Information for SANnet II 200 SCSI Field Replaceable Units (FRU s)

Supported RAID Controllers and Required Cables

Installing the IBM ServeRAID Cluster Solution

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Product Release Notes

Web Console Setup & User Guide. Version 7.1

IT Systems / Enterprise Storage Solutions EonStor A24F R2224

Auto Upgrade. Auto upgrade - Network Method

iscsi Storage Appliance Getting Started Guide

Entering the RAID Management Command Environment

Troubleshooting Cisco APIC-EM Single and Multi-Host

SmartGUI Configuration Guide. Revision V1.40. February

American Dynamics RAID Storage System iscsi Software User s Manual

ActiveAdmin CLI. Reference Guide. Revision 0.8

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

Sun StorEdge 3320 SCSI Array Controller Module Replacement Guide

Configuring Storage Profiles

AssuredSAN Event Descriptions Reference Guide

Configuring High Availability (HA)

RAIDCare 2.3 User Manual. NOTE: RAIDCare Client 2.3 will only work properly with RAIDCare Server 2.3

3.1. Storage. Direct Attached Storage (DAS)

HP Scalable File Share G3 MSA2000fc How To

Cisco UCS S3260 System Storage Management

HP SureStore E Disk Array 12H

NETWORK ATTACHED STORAGE

Firmware Download Guide (DSRD Dos Samsung Re-Drive)

HP-UX System Administration

Critical Analysis and last hour guide for RHCSA/RHCE Enterprise 7

Contents at a Glance COPYRIGHTED MATERIAL. Introduction...1 Part I: Becoming Familiar with Enterprise Linux...7

Lionstracs Groove X-R

SOFTWARE GUIDE VT-100. imageraid Series Storage System. (Text-based User Interface)

HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

the easy-to-use NAS-Solution NAS Series Network Hard Disk Drive Array Operation Manual

Toll Free: Tel: Fax:

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

SuperLumin Nemesis. Getting Started Guide. February 2011

Managing Network Adapters

High Availability and MetroCluster Configuration Guide For 7-Mode

Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training.

Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M

Managing RAID. Entering the RAID Management Command Environment CHAPTER

Maintenance Tasks CHAPTER

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Performing Administrative Tasks

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

User Guide. Storage Executive. Introduction. Storage Executive User Guide. Introduction

SAS to SATA II RAID Subsystem

LSISAS6160 SAS Switch r Firmware

At course completion. Overview. Audience profile. Course Outline. : 55187B: Linux System Administration. Course Outline :: 55187B::

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Cisco UCS S3260 System Storage Management

Maintenance Tasks. About A/B Partition CHAPTER

Maintaining the System Software

Janus SA-6643S Software User Manual

VTRAK E-Class/J-Class Quick Start Guide

"Charting the Course... MOC B: Linux System Administration. Course Summary

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Upgrading the MSA1000 for Enhanced Features

FlexFlash SD Card Support

Using the Offline Diagnostic Monitor Menu

This option lets you reset the password that you use to log in if you do not remember it. To change the password,

How to Restore Windows Server 2008 Domain Controller System State

IT Systems / Enterprise Storage Solutions EonStor A16U G2421

Southern Maine Community College Information Technology Professor Howard Burpee. Installing Windows Server 2012

ATTO Technology, Inc. ATTO AccelWare

Chassis Display Tasks

10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks:

2 Bay 3.5 HDD SATA NAS Media Server Setting...20 Bonjour...21 TorrentFlux Maintenance...25 Disk Utility...25 RAID Setting...

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

StorNext M330 Metadata Appliance Release Notes

Course 55187B Linux System Administration

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

Cisco UCS S3260 System Storage Management

Configuring and Using Redundant Disks with Cisco MCS

Table of Contents. Cisco The no service password recovery Command for Secure ROMMON Configuration Example

March , Revision B. SANnet II 200 SATA SE Array Quick Installation Guide

iscsi Gigabit Ethernet to SATA II External RAID System

Exam Name: Implementing HP StorageWorks Virtual

Cisco Videoscape Distribution Suite Transparent Caching Troubleshooting Guide

ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL. Version 2.2

SafeTANK GR5630-SB3. User Manual. v.1.0 (April, 2011)

Transcription:

SANnet II Manual Firmware Upgrade and Controller Recovery Step Guide - From 3.2x to 4.1x Guide Page 1 of 7

Please read this document in its entirety before proceeding with the firmware upgrade or Controller Recovery Steps. Prerequisites for Upgrading Firmware The prerequisites for installing the new firmware are: SANscape Command-Line Interface (CLI) version 2.1.1 or higher is required. If you do not have this package installed, or if you have an older version, download and install the latest version from the Dot Hill Customer Resource Center at http://crc.dothill.com. Upgrade script saves time. If the script is not an option go to Manually Upgrading Firmware. Using the script to perform the controller firmware upgrade saves time and reduces the probability of error. If possible, use the script to perform the controller firmware upgrade. The controller firmware script restores the following configuration settings: controller-name controller-id logical drive controller assignment (Primary/Secondary) host-wwn-name cache-parameters: write-back, write-through, random, sequential disk-array: normal-verify, rebuild-verify, init-verify, rebuild-priority drive-parameters: spin-up, disk-access-delay, scsi-io-timeout, queue-depth, polling-interval, enclosure-polling-interval, auto-detect-swap-interval, smart, auto-global-spare host-parameters: queue-depth, max-luns-per-id, fibre-connection-mode channels - This option restores the channel type, (disk or host), and target IDs. maps - This option restores the LUN mappings. All other settings will be set to the 4.11 default setting. Ethernet connections required for out-of-band firmware upgrades. For RAID controller firmware upgrades, an Ethernet connection (or two Ethernet connections for dual-controller configurations) is required for out-of-band firmware upgrades, if the array to be upgraded is not connected to the host on which the upgrades are to be performed. In order to use the Ethernet connection(s), the controller must have an IP address assigned. A Fibre Channel connection to the array is required when no network connection to the array is available. Stop all I/O to the array before beginning the controller firmware upgrade. Unmount all SANnet II 200 FC and SATA logical drives/luns from any hosts connected to the array, for the duration of the install procedure. For example, filesystems mounted from the SANnet II 200 FC device should be unmounted, and databases accessing raw devices on the array must be shut down. Do not exceed 32 partitions per logical drive. If your configuration has more than 32 partitions per logical drive (firmware 3.2x), you must back up the data on the affected logical drives, reconfigure the partitions per logical drive to less than 32, redistribute the data across the logical drives, and then upgrade the firmware. Page 2 of 7

You must reconfigure controller and network parameters after upgrading the controller firmware. For example, the controller password is not restored if you perform a manual upgrade or an inband upgrade using the script. The password is set to null when the upgrade completes. The controller password is restored if you perform an out-ofband upgrade using the script. You must have a serial connection to restore the IP address, netmask, and default gateway settings for your array when the upgrade completes. The serial connection must be set to 38400. Note the IP address, netmask, and default gateway settings for your array before you begin the upgrade. Using the RS-232 interface, note the filter map and sector/head/cylinder parameters, and record these settings. The RS-232 serial interface allows additional filter map and sector/head/cylinder parameters beyond what CLI allows. After the firmware is upgraded, there is no way to recover this information. For details, see Preparing to Update Controller Firmware on page 34. If you will be using the script to perform the upgrade: You must currently have controller firmware version 3.27R or later. If performing an in-band upgrade using the script, the controller password is not restored. The password is set to null when the upgrade completes. Be sure to specify a more secure controller password. Be aware that if the array controller is power-cycled at the wrong time during programming of the PLD firmware, the array controller may be rendered inoperable and require replacement. Due to important data integrity improvements in this release, the performance for RAID1 has been impacted. Random write operations are impacted the most -- performance is reduced by 10-20%. Stop any SANscape agent that may be running on a host connected to the array controller. The SANscape agent may interfere with the download of SES code and the script upgrade process. To stop the agent, issue the shell command: /etc/init.d/ssagent stop as root on any system where SANscape is installed. If the agent is running on a Microsoft Windows system connected to the array, use the Services application (Start->Run->services.msc) to stop the SANscape Agent service. Stop any optional software that monitors the array, such as the StorADE agent software, following the procedures described in the documentation for that application. StorADE, or any other application which monitors the status of the enclosure, may also interfere with controller or SES firmware downloads and the controller firmware script upgrade. Unpack the update into any convenient directory (for example, /var/tmp). To Determine the Current Controller Firmware Version To determine the current controller firmware version, use one of the following methods: Using the RAID controller serial or telnet interface, choose the view system Information firmware menu option. The current firmware version is displayed as Firmware Version. In the SANscape program, highlight any component of the desired array, choose View View Controller, and then check the FW Rev checkbox. Using SANscape CLI, enter the show inquiry command. Page 3 of 7

To Determine the Current SES and PLD Firmware Versions To determine your current SES and PLD firmware versions, using SANscape CLI enter the show ses command. The SES version of each controller is displayed in the Rev column. The PLD version is displayed in the PLD column. See Table 20 in the section Downloading and Installing Firmware on page 26 for the latest SES and PLD version information. To Determine the Current SATA Router and MUX Firmware Versions To determine your current SATA multiplexer (MUX) board firmware version, using SANscape CLI enter the show sata-mux command. The MUX version of each board is displayed in the PC150/Rev column. To determine your current SATA router firmware version, using SANscape CLI enter the show sata-router command. The router version is displayed in the Rev column. Manually Upgrading Firmware As always backup the data on the array. Dot Hill Systems will not be responsible for lost data if the data was not backed up prior to doing any upgrade. With doing a manual upgrade please have patience with the process and don t do anything until you get a message on the screen. You must use SCCLI 2.1.1 or higher to perform this upgrade. If upgrading from 3.2x to 4.1x there are some steps that MUST be taken in order for the firmware upgrade to be complete. After completing your backup the upgrade process can start. Page 4 of 7

Upgrading from 3.2x to 4.1x Preparation for the upgrade 1. You must currently have controller firmware version 3.27R or later. 2. Ethernet connections required for out-of-band firmware upgrades. For RAID controller firmware upgrades, an Ethernet connection (or two Ethernet connections for dualcontroller configurations) is required for out-of-band firmware upgrades, if the array to be upgraded is not connected to the host on which the upgrades are to be performed. In order to use the Ethernet connection(s), the controller must have an IP address assigned. 3. The tool that will be used for doing the upgrade is SANscape SCCLI 2.1.1. 4. Using the SCCLI capture the show config output to a file and print it out. 5. To get to the array oob the IP address of the array must be known prior to the following command: sccli <ip address> and press return. This will connect you to the array. 6. Using the SCCLI command, capture the show config output to a file and print it out. Example: sscli> show config filename.txt. The file will be output in the directory in which you ran the sccli executable. So it may be wise to but the path where the file can be found easily. 7. Stop all I/O to the array before beginning the controller firmware upgrade. Unmount all SANnet II 200 FC and SATA logical drives/luns from any hosts connected to the array, for the duration of the install procedure. For example, filesystems mounted from the SANnet II 200 FC device should be unmounted, and databases accessing raw devices on the array must be shut down. 8. Copy the firmware that is going to be used for the upgrade to a directory where it is easy to find and remember. Copying to a directory where the sccli command is run is a good place because the path does not need to be added to the command when doing the upgrades. Performing the Upgrade 1. Start up sccli on a machine that is direcdtly attached to the array or via the Ethernet network. For Ethernet Command: sccli <ip address> and press return and if directly connected the command is sccli. 2. To upgrade both controllers type the following command: download controller-firmware r filename.ext This process will take up to 10 minutes. Please be patient. 3. The sccli command line will change and at one point it will state resetting controller. Once the command line comes back to the sccli> prompt do the following. 4. Type the command reset nvram. Once this process is completed and the sccli> prompt is back do the following. 5. Power off the array for 10 seconds and power it back on. If there are JBOD s attached please power down all and bring back up in the proper order. Powering Down RAID unit first then JBOD s. Powering UP JBOD s first wait 30 seconds and then power on the RAID unit. If power cycling is not possible please issue this command: reset controller at the sccli> prompt. Once the prompt is back do the following, 6. Once these steps have been completed check the system using the sccli command: show inq and make sure that the output states the new firmware revision. Page 5 of 7

Performing the Upgrade if upgrade did not complete properly Prerequisite for doing the following upgrade steps: Prior to doing the following steps you must complete the steps that are now going to be outlined. 1. Remove one controller and power cycle. If the system comes up fine with one controller then power down and pull the one controller out and insert the other controller. If the system comes up fine then follow the next step. If at this point the system does not come up properly, with either controller, then contact Dot Hill support before going any further. 2. Power down the system and insert both controllers. Power the system back on. If the system does not come up or one controller keeps failing during boot up then the following steps can be tried. 3. Prior to following the controller recovery steps please contact Dot Hill support to verify the issue. Controller Recovery Steps To do the controller recovery steps each controller will be upgraded one at a time. This means that only one controller will be inserted at a time. Complete the following steps on each controller. Once completed power down the array and insert both controllers and power the array back on. 1. Start up sccli on a machine that is direcdtly attached to the array or via the Ethernet network. For Ethernet Command: sccli <ip address> and press return and if directly connected the command is sccli. 2. To upgrade one controller at a time type the following command: download controller-firmware filename.ext This process will take up to less than 10 minutes. Please be patient. 3. Once the command line comes back to the sccli> prompt do the following. Type the command reset nvram. Once this process is completed and the sccli> prompt is back do the following. 4. Power off the array for 10 seconds and power it back on. If there are JBOD s attached please power down all and bring back up in the proper order. Powering Down RAID unit first then JBOD s. Powering UP JBOD s first wait 30 seconds and then power on the RAID unit. If power cycling is not possible please issue this command: reset controller at the sccli> prompt. Once the prompt is back do the following. 5. Use a serial terminal application if you did this upgrade out-of-band and add the IP address back in so you can run sccli oob. 6. Once these steps have been completed check the system using the sccli command: show inq and make sure that the output states the new firmware revision. 7. If all comes back fine. Power down the array pull the upgraded controller out and insert the other controller. Now please follow steps 1 through 6 again under controller recovery steps for the second controller. Page 6 of 7

8. Once both controllers have been upgraded and steps 1 through 6 have been completed on each controller power down the array and insert both controllers. 9. Power on the array. 10. Verify the array comes up properly. If so, then complete the upgrade by adding all the pertinent information regarding your configuration, WWN, LUN mappings, and any other configuration parameters that need to be changed. Once that is completed start bringing your hosts back online one at a time. Do not use the Restore NVRAM in the serial terminal application. This will cause problems and the previous steps will have to be done over again. Page 7 of 7