Copper Certification Testing Best Practices Pocket Guide

Similar documents
White Paper: Installing Data Networks Using LinkWare Live SaaS

Datasheet: DSX CableAnalyzer Series

The High Cost of a Low-Cost Cable Certification Tester

White Paper: Choosing the RIght OTDR for your Datacenter

Get ready to overachieve.

Provided by

ANSI/TIA-568-C Cat 6A Field Test Specifications

Datasheet: DSX-5000 CableAnalyzer

Datasheet: DSX CableAnalyzer Series

Datasheet: DSX CableAnalyzer Series

Datasheet: FI-7000 FiberInspector Pro

Optical Fiber Test and Troubleshooting Solutions

How new testing standards affect you Singapore, Nov 2009

Datasheet: DSX CableAnalyzer Series

DTX-PCU6S. Users Manual. Patch Cord Adapters

Datasheet: FI-7000 FiberInspector Pro

ANSI/TIA-568-C Cat 6 Field Test Specifications

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Datasheet: DSX-5000 CableAnalyzer

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

LANmark-6 10G LANmark-6 A

DTX-PCxxS. Users Manual. Patch Cord Test Adapters

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

OneTouch AT Network Assistant Configuration Guide

DTX CableAnalyzerTM Accessories Guide

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

Field-testing procedure. LANmark-6

Certifying Power over Ethernet to Ensure Service Success

OptiFiber Certifying OTDR Accessories Guide. See how Fluke Networks options and accessories can enhance your investment.

Certification for 10G copper cabling

Chapter 3 Certifying Twisted Pair Cabling

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Network SuperVision Solutions

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks

Schneider Electric Critical Power & Cooling Services. Services to keep your mission-critical applications operating at optimal performance

Ronald Tellas, Technology and Applications Manager, Enterprise Networking

Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.

Complimentary Reference Material

Datasheet: OptiView XG Network Analysis Tablet - Version 11 Software Release and OptiView Performance Test Remote

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

ROI CASE STUDIES. Case Study Forum. Credit Union Reduces Network Congestion, Improves Productivity, and Gains More than $800,000 in Benefits with

DTX Series. Technical Reference Handbook. CableAnalyzer

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

Capabilities Statement W. Catawba Ave Cornelius NC (704) Phone (800) Fax

DTX Series. Users Manual. CableAnalyzer

CERTIFICATION PLUS SM

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Softing PROFINET Diagnostic Tools

15 Ways Belden Helps Reduce Human Error to Improve Uptime

OptiView Series III. Wireless Suite. Technical Datasheet. As a network manager, it s your task to. support new users, new networks, new

DTX Series. Technical Reference Handbook. CableAnalyzer

DTX-NSM Network Service Module Getting Started Guide

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

Service Description: Solution Support for Service Provider Software - Preferred This document

Training Offer. Catalogue

Course Outline 11/6/ Santa Teresa Blvd Gilroy, CA COURSE: CSIS 274 DIVISION: 50 ALSO LISTED AS: SHORT TITLE: TELECOM/NETWK CABLE

Cisco SMARTnet Service

Copper Cabling Standards

TiR2, TiR3, TiR4. Getting Started Guide. IR FlexCam Thermal Imager

White Paper: Audio / Video (AV) Cabling Considerations

IBM s Integrated Data Management Solutions for the DBA

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

Largest Cat 6A Installation in Midwest Pushes Frontiers of Networking Technology

Maintain Your F5 Solution with Fast, Reliable Support

to your Pocket PC? 3. Click new to connect

HPE Proactive 24 Service

Power over Ethernet POEINJ100 POESPLT100. Instruction Manual. 10/100 POE Power over Ethernet Injector - 48V

XS, XST. IR InSight Thermal Imager. Getting Started Guide

PANGEN SYSTEM WARRANTY. Warranty Guide

Application Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

Service Description: Dell Same Business Day On-site Service ( Same Business Day )

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

EtherScope Series II Network Assistant

Capabilities Statement. Headquarters: Charlotte, NC Phone:

How to cable n Wireless Access Points

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales

The 5700A/5720A High Performance Multifunction Calibrators. Taking Accuracy to a Whole New Level

CHAPTER 7 Copper Cable Testing

A revolutionary visual security and analytics solution

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

Optical Certifier I. Tier-1 Fibre Certifier for Multimode and Single-mode Fibre Cabling. Proof of Performance

Introduction. Standards

CardBus USB 2.0 Card. 2 Port USB 2.0 CardBus USB Card CBUSB220. Instruction Manual. Actual product may vary from photo

Agilent Technologies VQT Phone Adapter J1996A

LEAVE THE TECH TO US

Link Analyzer. Supports 10/100 Mbps RJ-45 UTP or LX/SX/T Gigabit Ethernet using hotswappable

CONTENT PAGE. Giganet Company Overview... Giganet Category 5e UTP System... Giganet Category 5e UTP Patch Panel... Giganet Category 5e UTP Cable...

AppPulse Point of Presence (POP)

Network Adapter. 10/100/1000 Mbps PCI Ethernet Card. Installation Guide ST1000BT32. Actual product may vary from photo

Reasons to connect your tools

Professional Network Infrastructure Label Printer

Getting Started Guide

LANcat System 6 with C5e Performance Module. User Manual Addendum

HPE Hardware Support Exchange Service

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

Transcription:

Copper Certification Testing Best Practices Pocket Guide

Cabling certification is a best practice of world class installers because it shows the true quality of the installation and reduces the risk of expensive rework. Why are Copper Testing Best Practices so important? Installers save time by doing it right the first time and customers accept the work faster when the manufacturer systems warranty is issued promptly.

Cabling Certification lowers risk for network owners because it ensures that the installed system meets cabling industry standards and network requirements. Cabling Certification lowers risk for Architects, Consultants, and Engineers responsible for designing communications networks because it is the only way to prove that the system performance meets the intended purpose as designed. Cabling Manufacturers lower their risk by offering system warranties that require cabling certification. By certifying all their jobs, installers lower their own risk. Finger pointing and callbacks are every contractor s worst nightmare. Risk of liability far outweighs any excuses to avoid Cabling Infrastructure Certification. This Copper Certification Testing Best Practices pocket guide was designed by Fluke Networks to share important handling best practices, including: Assessing the correct normative requirements to ensure certification by industry standards. Performing the actual certification. Troubleshooting. Documentation. Whether you handle copper infrastructure on a regular basis or just occasionally, this pocket guide will serve as a useful tool to ensure you never miss a critical step during your copper testing or troubleshooting.

Best Practice #1: Assess Normative Requirements When should you do it? Prior to starting any job Why should you do it? Selecting the correct Test Limit ensures all required measurements are made in the required frequency range. If tests are performed against the wrong limit, the team may have to return to the site to redo the work. This can seriously impact profitability and cause the contractor to incur liability risks.

Ensure the tester is properly configured Contractual specifications will cover the testing of the copper cabling. The contractor should fully understand the field test requirements expected upon completion of the installation. In case of 500 MHz cabling being installed it may state: Every cabling link in the installation shall be tested in accordance with the field test specifications defined in ISO/IEC 11801:2010 Amd.2 Class E A Permanent Link or ANSI/TIA-568-C.2 Category 6A Permanent Link. It is recommended that a knowledgeable user configures the tester upfront using the ProjX TM Management system allowing the testing to be performed by an entry-level technician. The tester now can roam from project to project. Measurements will continue where left off, minimizing the chance for human error, guaranteeing time savings. Configuring can be done both in the field or remotely through a web browser (using LinkWare Live). Test Leads As indicated in the standard, crimping an RJ45 plug onto a patch cord to make a test lead results in unpredictable performance. The removable test plug referenced as an option in the TIA-568-C.2 and ISO/IEC 61935-1 is found on the end of the DSX-PLA004 Permanent Link Adapter. Every tip is fully compliant for NEXT, FEXT and Return Loss. DSX-PLA004 Permanent Link Adapter Example of a test plug using a PCB substrate

Best Practice #2: Certification Testing When should you do it? After any link installation or modification to ensure the job meets the cabling infrastructure standards specifications. Why should you do it? It is required by internationally recognized standards such as ISO/IEC 11801 and ANSI/TIA-568-C to ensure a quality installation.

What instruments should you use? A CableAnalyzer TM or cable tester that consists of a main unit and a remote unit. The main unit is typically used in the cabinet to connect to the patch panels and the remote units gets connected to the far end of the links. Before you begin testing, you should verify the basics: Are you using the most current version of the tester software? Is the tester within its operating temperature range and in calibration? Has the correct test standard been selected? Pay particular attention to the NVP as it plays a critical role when the tester reports length or distance to a defect. Has the correct link model (Permanent Link or Channel) been selected? Are you using the appropriate test adapter with a plug that matches the jack in the telecommunication outlet (TO) or the patch panel? Has the test reference recently been set? It is recommended to set the reference on a regular basis and at a time that is easy to remember (such as the start of each week). You are now ready to press TEST and the cable tester will display results as a Pass or Fail based on the outcome of the comparison of the measurements against the standards limits. By uploading test results the quality of the executed work can then be checked as the LinkWare Live Professional software provides instant notification about incorrect test setups and cable IDs. Fluke Networks Certification Testing Solutions DSX-5000 CableAnalyzer TM

Best Practice #3: Troubleshooting When should you do it? In case a Fail or Marginal Pass occurs while testing. Why should you do it? All links must Pass before a manufacturer will issue a warranty statement. Powerful troubleshooting capabilities in a tester allow technicians to quickly isolate and repair installation problems.

What instrument should you use? A CableAnalyzer TM or cable tester that produces diagnostic information for the cabling link that fails or marginally passes (a so called Pass* result). Troubleshooting Procedure If you prefer to leave the troubleshooting to your experts, use the FIX LATER feature when a Fail or Pass* occurs. FIX LATER creates a punch list of links that an experienced technician can troubleshoot and repair, allowing technicians to continue their regular certification testing without interruption. Look under DIAGNOSTICS for a schematic view of the location and cause of any faults. For in-depth insight, use the tester s ability to report the distance to a location along the link-under-test where crosstalk or Return Loss is excessive. The two parameters that provide this time domain information are HDTDX (High Definition Time Domain Crosstalk) and HDTDR (High Definition Time Domain Reflectometry). Once a link has been fixed, connect the CableAnalyzer to the fixed link and tap TEST again. The result for the passing link can then be stored, and the link identifier will be cleared from the punch list. Powerful DSX-5000 Troubleshooting Capabilities DSX-5000 uses patentpending technology to detect connector problems. DSX-5000 HDTDX Analyzer.

Best Practice #4: Documentation When should you do it? save results after completing a measurement. Why should you do it? Good record-keeping is a smart practice. It enforces installation accountability and integrity, helps to resolve disputes and facilitates more efficient troubleshooting.

What documentation software should you use? LinkWare PC Cable Test Management Software that lets you manage all the results from multiple testers and jobs using one application. Documentation Procedure After each measurement save the results. For troubleshooting purposes always consult results in their unabridged format in order to have the most complete and accurate troubleshooting data. Upon completion of the job or at any desired moment you can either upload the results from the tester via a direct connection to the PC or via LinkWare Live, a SaaS (Software as a Service) solution from Fluke Networks. Once test results are downloaded into the LinkWare PC Cable Test Management Software, you can deliver results in the complete LinkWare file format or generate professional reports in a common format (such as PDF). Fluke Networks Documentation Solutions LinkWare PC Report LinkWare Live SmartPhone Interface

Best Practice #5: Maintenance and Technical Support When should you consider it? From the day you acquire a tester and on a yearly basis to ensure equipment stays in top shape. Why should you worry about it? To ensure service and support is there when you need it, minimizing business downtime and ensuring a high return on your investment.

What kind maintenance and support agreement do you need? One that is like insurance. A comprehensive support and maintenance program that covers all products and accessories as well as access to technical specialists 24/7. Versiv Maintenance & Support Solutions Benefits Live technical support with exclusive phone number FREE Annual Calibration and Factory Refresh FREE Repair with first on bench turnaround service Standard Warranty Gold Support Loaner Equipment Service* FREE Accessory Replacements** Lifetime Buyback Guarantee Member Only Promotions Tech Support Response Time < 24 Hours < 2 Hours Support Phone and Email Working hours 24 x 7 x 365 Software and Firmware upgrades Online training video and Knowledge Base access LinkWare Live Professional *Available in certain geographies **Applies to accessories in the original product purchase Gold support provides similar benefits for other products contact your Fluke Networks representative for details.

LinkWare Live Test Results Management Service LinkWare Live is a SaaS (Software as a Service) that provides cable installation professionals with project and test result management capabilities to get unmatched job visibility and superior job control from anywhere at any time. Report generation via PC running LinkWare Cable Test Management Software With LinkWare Live, Professional Project Managers have an extremely powerful tool available to ensure jobs get done right first time: Real-time access to test results ensures issues are diagnosed in the early stages of the job eliminating expensive rework and Instant notification about incorrect test setups and cable IDs for uploaded test results ensures testing is completed to specification.

DSX-5000 CableAnalyzer The DSX-5000 improves the efficiency of copper certification with a 10 second CAT 6A test wile meeting the most stringent accuracy requirements. Endorsed by more than twenty five manufacturers worldwide. ProjX management system ensures jobs are done right the first time. The modular Versiv platform supports fiber testing and upgrades to future standards. Analyze test results and create professional test reports using LinkWare reporting software. Upload results and manage multiple jobs from any smart device through LinkWare Live. The Versiv tester has increased our technicians productivity in the field allowing for easy setup and faster testing of cables. The ease of which we can download stored test results and leave the tester in the field has also contributed to their productivity. Using the same unit for copper and fiber testing keeps everyone familiar with the setup and testing procedures Bill Quinn, Estimator/Project Manager, Global Security International, LLC

Ensure the network goes up and stays up! Visit www.flukenetworks.com/design for additional resources to help you establish Certification Testing Best Practices. Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. 2015 Fluke Corporation. All rights reserved. 04/2015 7000115