SEMI-ACTIVE CONTROL OF BUILDING STRUCTURES USING A NEURO-FUZZY CONTROLLER WITH ACCELERATION FEEDBACK

Similar documents
Hybrid Geno-Fuzzy Controller For Seismic Vibration Control

DEVELOPMENT OF SUBSTRUCTURED SHAKING TABLE TEST METHOD

European Journal of Science and Engineering Vol. 1, Issue 1, 2013 ADAPTIVE NEURO-FUZZY INFERENCE SYSTEM IDENTIFICATION OF AN INDUCTION MOTOR

A FIXED-BASE MODEL WITH CLASSICAL NORMAL MODES FOR SOIL- STRUCTURE INTERACTION SYSTEMS

Neuro Fuzzy Controller for Position Control of Robot Arm

SURFACE ROUGHNESS MONITORING IN CUTTING FORCE CONTROL SYSTEM

Bi-directional seismic vibration control of spatial structures using passive mass damper consisting of compliant mechanism

COMPLETE DECENTRALIZED DISPLACEMENT CONTROL ALGORITHM

Study Of Structural Control In Coupled Buildings

Development of Fuzzy Logic Controller by Particle Swarm Optimization Algorithm for Semi-active Suspension System using Magneto-rheological Damper

A NOUVELLE MOTION STATE-FEEDBACK CONTROL SCHEME FOR RIGID ROBOTIC MANIPULATORS

Neuro-fuzzy Learning of Strategies for Optimal Control Problems

Cancer Biology 2017;7(3) A New Method for Position Control of a 2-DOF Robot Arm Using Neuro Fuzzy Controller

Help Page for the Java-Powered Simulation for Experimental Structural Dynamics

STUDY ON MODEL REDUCTION OF LARGE STRUCTURAL SYSTEMS FOR ACTIVE VIBRATION CONTROL

Deciphering Data Fusion Rule by using Adaptive Neuro-Fuzzy Inference System

CONTROL OF A BENCHMARK STRUCTURE USING GA-OPTIMIZED FUZZY LOGIC CONTROL

MODELING FOR RESIDUAL STRESS, SURFACE ROUGHNESS AND TOOL WEAR USING AN ADAPTIVE NEURO FUZZY INFERENCE SYSTEM

Intelligent Control. 4^ Springer. A Hybrid Approach Based on Fuzzy Logic, Neural Networks and Genetic Algorithms. Nazmul Siddique.

SEISMIC TESTING OF LARGE SCALE STRUCTURES WITH DISSIPATOR DEVICES

Title. Author(s)P. LATCHAROTE; Y. KAI. Issue Date Doc URL. Type. Note. File Information

CU-NEES Instructional Shaking Table

Reference Variables Generation Using a Fuzzy Trajectory Controller for PM Tubular Linear Synchronous Motor Drive

Implementing Machine Learning in Earthquake Engineering

VIBRATION ISOLATION USING A MULTI-AXIS ROBOTIC PLATFORM G.

A building structural-performance monitoring system using RFID tag with sensors

REAL-TIME IDENTIFICATION OF MAGNETO-RHEOLOGICAL DAMPERS 1. Instituto de Ingeniería, Universidad Nacional Autónoma de México, Coyoacán DF, México

Methodology for Prediction of Sliding and Rocking of Rigid Bodies Using Fast Non-Linear Analysis (FNA) Formulation

Robust Pole Placement using Linear Quadratic Regulator Weight Selection Algorithm

Optimal Placement and Design of Passive Damper Connectors for Adjacent Structures

Analysis of Control of Inverted Pendulum using Adaptive Neuro Fuzzy system

Recent developments in Real-Time Hybrid Simulation (RTHS)

Verification and Validation for Seismic Wave Propagation Problems

The analysis of inverted pendulum control and its other applications

In the Name of God. Lecture 17: ANFIS Adaptive Network-Based Fuzzy Inference System

Fuzzy Based Decision System for Gate Limiter of Hydro Power Plant

Tutorial for Response Spectrum Analysis using CAEPIPE

Neural Network modeling of forward and inverse behavior of rotary MR damper

ANFIS: ADAPTIVE-NETWORK-BASED FUZZY INFERENCE SYSTEMS (J.S.R. Jang 1993,1995) bell x; a, b, c = 1 a

SEMI-ACTIVE VIBRATION CONTROL WITH ON-LINE IDENTIFICATION OF THE INVERSE MR DAMPER MODEL

PSO based Adaptive Force Controller for 6 DOF Robot Manipulators

NEW HYBRID LEARNING ALGORITHMS IN ADAPTIVE NEURO FUZZY INFERENCE SYSTEMS FOR CONTRACTION SCOUR MODELING

Transactions on Information and Communications Technologies vol 16, 1996 WIT Press, ISSN

NUMERICAL SIMULATION OF SHAKING TABLE TESTS ON DYNAMIC RESPONSE OF DRY SAND

Intelligent Methods in Modelling and Simulation of Complex Systems

Fuzzy based Excitation system for Synchronous Generator

Decentralized Control Strategies with Wireless Sensing and Actuation

MODELING AND SIMULATION METHODS FOR DESIGNING MECHATRONIC SYSTEMS

CHAPTER 8 ANFIS MODELING OF FLANK WEAR 8.1 AISI M2 HSS TOOLS

17. SEISMIC ANALYSIS MODELING TO SATISFY BUILDING CODES

Feasibility of real-time distributed structural control upon a wireless sensor network

CHAPTER 3 INTELLIGENT FUZZY LOGIC CONTROLLER

Liquefaction Analysis in 3D based on Neural Network Algorithm

Application of Wireless Sensors for Structural Health Monitoring And Control

FINE TUNING OF FUZZY CONTROLLERS FOR VIBRATION SUPPRESSION OF SMART PLATES USING PARTICLE SWARM OPTIMIZATION

Simulation and Modeling of 6-DOF Robot Manipulator Using Matlab Software

[Time : 3 Hours] [Max. Marks : 100] SECTION-I. What are their effects? [8]

ANFIS based HVDC control and fault identification of HVDC converter

1314. Estimation of mode shapes expanded from incomplete measurements

INCREMENTAL DISPLACEMENT ESTIMATION METHOD FOR VISUALLY SERVOED PARIED STRUCTURED LIGHT SYSTEM (ViSP)

Modal pushover-based scaling of records for nonlinear RHA of one-story unsymmetric-plan buildings

ROBOTICS 01PEEQW. Basilio Bona DAUIN Politecnico di Torino

Force control of redundant industrial robots with an approach for singularity avoidance using extended task space formulation (ETSF)

A Comparison between a Fuzzy and PID Controller for Universal Motor

EXPLICIT DYNAMIC ANALYSIS OF A REINFORCED CONCRETE FRAME UP TO COLLAPSE

A STUDY ON THE INFLUENCE OF BOUNDARY CONDITIONS ON THREE DIMENSIONAL DYNAMIC RESPONSES OF EMBANKMENTS

CHAPTER 4 FUZZY LOGIC, K-MEANS, FUZZY C-MEANS AND BAYESIAN METHODS

Seismic regionalization based on an artificial neural network

A Comparative Study of Prediction of Inverse Kinematics Solution of 2-DOF, 3-DOF and 5-DOF Redundant Manipulators by ANFIS

INTERACTIVE LEARNING FRAMEWORK FOR DYNAMIC SIMULATION AND CONTROL OF FLEXIBLE STRUCTURES. M. O. Tokhi and S. Z. Mohd. Hashim 1.

Tracking Error-Based Servohydraulic Actuator Adaptive Compensation for Real-Time Hybrid Simulation

ANALYTICAL STRUCTURES FOR FUZZY PID CONTROLLERS AND APPLICATIONS

A New Fuzzy Neural System with Applications

Simulation-Based Design of Robotic Systems

Introduction to Control Systems Design

FUZZY INFERENCE SYSTEMS

Rocking Component of Earthquake Induced by Horizontal Motion in Irregular Form Foundation

Design procedures of seismic-isolated container crane at port

Bathymetry estimation from multi-spectral satellite images using a neuro-fuzzy technique

New paradigm for MEMS+IC Co-development

Resolution of spherical parallel Manipulator (SPM) forward kinematic model (FKM) near the singularities

Adaptive Neuro Fuzzy Inference System (ANFIS) For Fault Classification in the Transmission Lines

Neuro-Fuzzy Inverse Forward Models

CHAPTER 5 RANDOM VIBRATION TESTS ON DIP-PCB ASSEMBLY

F2014-AHF-014 A HUMAN MODEL USING COMBINED FUNCTIONS OF OF UML, MATLAB/SIMULINK AND CODE-LIBRARY. TECHNOLOGIES LIMITED, Japan

CHAPTER 1 INTRODUCTION

Analysis of Pile Behaviour due to Damped Vibration by Finite Element Method (FEM)

Lab 2: Real-Time Automotive Suspension system Simulator

Design of Different Fuzzy Controllers for Delayed Systems

CHAPTER 3 FUZZY RULE BASED MODEL FOR FAULT DIAGNOSIS

Robotics: Science and Systems

A METHOD TO MODELIZE THE OVERALL STIFFNESS OF A BUILDING IN A STICK MODEL FITTED TO A 3D MODEL

A substructure based parallel dynamic solution of large systems on homogeneous PC clusters

Adaptive Neuro-Fuzzy Model with Fuzzy Clustering for Nonlinear Prediction and Control

Mechanics ISSN Transport issue 1, 2008 Communications article 0214

Prof. Fanny Ficuciello Robotics for Bioengineering Visual Servoing

Kinematics and dynamics analysis of micro-robot for surgical applications

Lab 2: Real-Time Automotive Suspension system Simulator

Vibration Analysis with SOLIDWORKS Simulation and SOLIDWORKS. Before you start 7

Simulation of a Dual Axis MEMS Seismometer for Building Monitoring System

Transcription:

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 PAPER REF: 5778 SEMI-ACTIVE CONTROL OF BUILDING STRUCTURES USING A NEURO-FUZZY CONTROLLER WITH ACCELERATION FEEDBACK M. Braz-César 1(*), K. Oliveira 2, Rui C. Barros 3 1 Department of Applied Mechanics (DMA), Polytechnic Institute of Bragança, Bragança, Portugal 2 Polytechnic Institute of Bragança, Bragança, Portugal 3 Department of Civil Engineering (DEC), University of Porto, Portugal (*) Email: brazcesar@ipb.pt ABSTRACT The present paper investigates the effectiveness of a neuro-fuzzy controller to reduce the response of building structures subjected to seismic excitations. The proposed controller was developed using an Adaptive Neuro-Fuzzy Inference System (ANFIS) to train a fuzzy logic system. In this case, floor acceleration measurements are used to compute the desired control signal to command a MR damper. A numerical example involving a three degrees of freedom building structure excited by the El Centro earthquake is presented to demonstrate the effectiveness of the proposed semi-active control system in reducing the response under seismic loading. A comparison between uncontrolled and controlled structural responses are used to validate the performance and efficiency of the proposed semi-active controller. Keywords: Structural control, semi-active control, neuro-fuzzy, MR dampers. INTRODUCTION The present paper investigates the effectiveness of a neuro-fuzzy controller to reduce the response of building structures subjected to seismic excitations. A numerical analysis was carried out comprising the structural control of a three-story structure under the El Centro earthquake excitation using a single MR damper located between the base and the first floor. In this case, the sensors and the actuator are placed in different locations and therefore the control system has a non-collocated configuration. The uncontrolled response under harmonic excitation and seismic loading were obtained, which will be used as reference values for the remaining numerical simulations. Then, the seismic responses of the structure with one MR damper installed in the first floor and operating in a passive and semi-active configurations are obtained and analyzed. The numerical analysis was conducted with the aim of verify the efficiency of a neuro-fuzzy controller with acceleration feedback in reducing the seismic response of the structure. NUMERICAL MODEL Consider a controlled system subjected to an earthquake excitation as illustrated in Fig. 1. In this case the actuator is a MR damper that can be used as a passive dissipation device or in a semi-active control mode. In this last approach, the damper force can be changed using a control system comprising a controller that monitors the system response and computes the required damping force that should be applied to improve the structural performance. An effective semi-active control involves an appropriate control algorithm that can take advantage of the dissipative properties of the control device (Dyke, 1997; Jansen, 2000). -1177-

Symposium_3 Dynamics, Stability and Control in Structural Engineering Fig. 1 - Schematic representation of a 3DOFs system under earthquake excitation. Semi-active control with a MR damper at the first floor. In this case the structure is equipped with a MR damper (Lord RD-1005-03 model) located between the ground floor and the first floor which can operate in two modes: as a passive energy dissipation device and as a semi-active actuator whose control action is being commanded by a neuro-fuzzy based controller. The modified Bouc-Wen model was selected to simulate the hysteretic behavior of the MR damper. The numerical formulation and the corresponding model parameters are presented in Table 1 (Braz-César, 2013). Besides, the first-order time lag involved in the current driver/electromagnet during a step command signal must be included in the numerical model of the device, which in this case is defined by a first order filter (η= 130 sec -1 ). Table 1 - Modified Bouc-Wen model - Parameters of the RD-1005-3 MR damper (Braz-César, 2013). Modified Bouc-Wen model y Bouc-Wen x c 1 k0 c0 F k1 Current independent parameters Current dependent parameters A [-] β [mm 1 ] γ [mm 1 ] k 0 [N/mm] f 0 [N] n 10.013 3.044 0.103 1.121 40 2 [N] [N.s/mm] [N.s/mm] -1178-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 In what follows, the results of the semi-active control system are compared with the uncontrolled, passive OFF and passive ON responses to evaluate the efficiency of each semiactive control scheme in reducing the structural response. The mass, damping and stiffness matrices of the model structure can be determined as (1) (2) (3) In this study, the structure will be subjected to the El-Centro ground motion (1940 N-S component with a peak acceleration of 3.42 m/s 2 ). Since the mechanical system seeks to represent a small-scale building, the earthquake signal needs to be decreased to represent the magnitude of displacements that would be observed in experiments tests. Thus, the time was scaled to 20% of the full-scale earthquake time history as shown in Fig. 2. Fig. 2 - Time-scale El-Centro NS earthquake ground motion (0.2t). The state space equation of motion is given by (4) where the column vector λ represents the location of the earthquake excitation (i.e., the seismic acceleration). Equation 4 can be written in a simplified form as where matrix A represent the system matrix (5) -1179-

Symposium_3 Dynamics, Stability and Control in Structural Engineering (6) and E is the disturbance locating vector given by (7) The response of the system can be computed using the state space output vector y(t) If the system displacements, velocities and accelerations are required, then (8) (9) The uncontrolled response is displayed in Fig. 3. Fig. 3 - Uncontrolled response of the 3DOFs system. -1180-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 It should be noted that the response was obtained with a high excitation level of the El Centro earthquake achieved by scaling up the amplitude of the earthquake signal in 150%. This modification in the excitation signal was used only to amplify the magnitude of the displacements making the system response more compatible with the operating range of the MR damper. The equation of motion of the controlled structure can be defined by a state space formulation as (10) where B c is an additional matrix accounting for the position of the control forces in the structure and f c is a column vector with the control forces. The location of the control forces is defined by a location matrix Γ within B c. In this case there is only one control force applied to the first mass and therefore, it follows that and then (11) (12) Equation 10 can be written in a more compact given that (13) and finally (14) The response of the system can be determined using the state space output vector (15) where C is the same matrix of Equation 9, D c comprising the control forces is (16) and the column vector F describing the location of the earthquake signal is given by As for the state space equation, ẍ g (t) represents the seismic excitation loading. (17) -1181-

Symposium_3 Dynamics, Stability and Control in Structural Engineering NEURO-FUZZY CONTROLLER Neuro-adaptive learning techniques represent a simple methodology for the fuzzy modeling procedure to learn information about a dataset in order to compute the membership function parameters that best allow the associated fuzzy inference system to track a given input/output data. ANFIS uses a hybrid learning algorithm that combines the backpropagation gradient descent and least squares methods to create a fuzzy inference system whose membership functions are iteratively adjusted according to a given set of input and output data (Jang, 1993; Schurter, 2001). The reasoning scheme of ANFIS architecture is shown in Fig. 4. Fig. 4 - Adaptive Neuro-Fuzzy Inference System or ANFIS. Soft computing methods represent a relatively recent optimization/modeling techniques that have been shown to be effective in representing the non-linear behavior of structural systems. The development of a neuro-fuzzy controller for MR dampers involve four main steps: 1. Definition of input variables and the corresponding FIS membership functions (the FIS output is the desired control signal); 2. Selection of experimental or artificial data sets to generate training and checking data; 3. Use of ANFIS optimization algorithm for training the FIS membership function parameters to model the set of input/output data by mapping the relationship between inputs and outputs in order to generate a neuro-fuzzy model controller; 4. Validation of the resulting fuzzy model. In what follows, a neuro-fuzzy controller was designed by using an ANFIS model to find the nonlinear map (fuzzy inference system) that best fits the expected response of the control system. The proposed controller was developed based on the numerical results of the LQG control system whose response is used to define the training data set for the neuro-fuzzy optimization procedure with ANFIS. In this case, floor accelerations constitute the responses of the controlled system used by the LQG controller to determine the desired control force. Subsequently, the required control signal is determined from the predicted control force using an inverse Bingham model of the MR damper. The data set for training and validation was obtained through numerical simulations by exposing the LQG controlled system to a set of amplitude-scaled versions of the El Centro NS earthquake excitation, i.e., 100gal (30%), 200gal (60%), 335gal (100%) and 335gal (150%) seismic accelerations. -1182-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 The system responses and the desired control signal were recorded and then used to train the neuro-fuzzy controller. In this case, floor accelerations are the FIS inputs while the command current represents the fuzzy outcome. An initial, increasing and decreasing step sizes of 0.12, 1.20 and 0.8, respectively during 200 epochs are the parameters involved in the ANFIS optimization procedure. The optimal number of membership functions (MFs) was defined through a trial-and-error process. In this case, three bell-shaped MFs were used to model each input variable. The universe of discourse of each fuzzy variable is not normalized displaying maximum and minimum values according with the results of the clipped-optimal LQG controller. The resultant fuzzy surfaces are shown in Fig. 5 to 7. Although these fuzzy surfaces do not allow a fully interpretation of the fuzzy controller since all input variables must be combined in accordance with the trained fuzzy inference system to obtain a signal output, they provide crucial information about the interaction between the inputs and the effect of these on the corresponding model output. Fig. 5 - Fuzzy surface of the inference system - I(acc1,acc2). Fig. 6 - Fuzzy surface of the inference system - I(acc2,acc3). -1183-

Symposium_3 Dynamics, Stability and Control in Structural Engineering Fig. 7 - Fuzzy surface of the inference system - I(acc1,acc3). One of the main problems that may arise is that ANFIS can determine an inference system whose output variable is outside the limits of the desired signal. This effect can be reduced selecting appropriate training data sets (e.g., remove sparse data points, extending and increasing the number of data points around the minimum and maximum values of the variable output, etc.) and also choosing the appropriate number and properties of the membership functions. This type of neuro-fuzzy systems can present high peaks near the corners of the surface. Depending on the fuzzy composition rules, these peaks can produce an incorrect output signal. If the surfaces are within the expected output range or if small peaks are visible only in very specific areas of the surface but the fuzzy system output has a small error, the fuzzy model can be easily tuned by adjusting the inputs and output variables. Otherwise, the optimization procedure of the fuzzy inference system should be reconsidered to improve the fuzzy system. The corresponding Simulink block of the neuro-fuzzy controller is represented in Fig. 8. As can be observed, saturation blocks are used after the scaling factors to ensure that the structural accelerations are always within the range of values of the corresponding fuzzy variable (K c =2.5). Likewise, a saturation block was used to limit the minimum and maximum values of the FIS output, i.e., the control current to the operating range of the MR damper (I min =0.0A and I max =0.5A). -K Saturation Ka1 1 Current Saturation3 Kc Fuzzy Logic Saturation1 -K- -K- Ka2 1 Floor accelerations -K- Saturation2 Ka3 Fig. 8 - Simulink block of the neuro-fuzzy controller. -1184-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 A new numerical simulation was carried out to obtain the response of the three DOF structure to the time-scale earthquake excitation (i.e., El Centro NS). The system response for the passive OFF case along with the maximum and minimum values of each output variable is displayed in Figure 9 and the damper behaviour is characterized in Figure 10. Fig. 9 - Results with the Modified Bouc-Wen model Passive OFF case. Fig. 10-3DOFs system - RD-1005-03 MR damper control force. Passive OFF case Modified Bouc-Wen model -1185-

Symposium_3 Dynamics, Stability and Control in Structural Engineering Likewise, a numerical simulation was carried out to obtain the response of the three DOF structure to the time-scale earthquake excitation for the passive ON mode. The corresponding system response along with the maximum and minimum values of each output variable is displayed in Figure 11 and the damper behaviour is characterized in Figure 12. Fig. 11 - Results with the Modified Bouc-Wen model Passive ON case. Fig. 12-3DOFs system - RD-1005-03 MR damper control force. Passive ON case Modified Bouc-Wen model -1186-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 The Simulink model of the semi-active control system based on the neuro-fuzzy controller is displayed in Figure 13. As can be observed in this figure, floor accelerations of the building structure constitute the responses of the controlled system used by the controller to determine the desired control signal. xc.mat Displacements Displacements Floor accelerations [t g] EarthQuake Signal -K- Amp x' = Ax+Bu y = Cx+Du State-Space vc.mat Velocities ac.mat Accelerations Velocities Accelerations 1st floor velocity 1st floor displacement MR damper RD-1005-3 Response selection (Fuzzy - Fuzzy) Displacement Fc.mat Force Velocity Damper force Current i_eta.mat i_ctrol.mat Modified Bouc-Wen model Current_eta Current_ctrl Out In vo vi Current Floor accelerations filter(eta) Adjust FLC Fig. 13 - Simulink model of the neuro-fuzzy control system. The structural responses obtained with the neuro-fuzzy based control system along with the uncontrolled response of the third floor are displayed in Figure 14. The peak responses of the both uncontrolled and controlled systems are listed in Table 2. The results show the effectiveness of the proposed controller in reducing the response of the structure. Table 2 - Peak responses under the time-scaled El-Centro earthquake. Control strategy Passive OFF Uncontrolled Modified Bouc-Wen 0.695 1.251 1.587 0.518 0.907 1.191 27.09 45.78 54.02 20.02 34.51 42.79 1305 1736 2272 999 1358 1791 ---- 166.4 Passive ON Modified Bouc-Wen Neuro-fuzzy controller 0.171 0.423 0.560 0.164 (-4%) 0.410 (-3%) 0.529 (-6%) 7.77 19.36 25.58 7.07 (-9%) 17.59 (-9%) 23.68 (-8%) 613 1066 1366 739 (21%) 963 (-10%) 1285 (-6%) 1048.9 909.8-1187-

Symposium_3 Dynamics, Stability and Control in Structural Engineering Fig. 14 - Structural responses obtained with the neuro-fuzzy controller. As can be seen, the semi-active control system achieves a good performance in reducing the structural responses using floor accelerations as the reference signals to compute the control action. In fact, the main advantage of the proposed control system is that only acceleration responses are required to determine the control action. This means that the damping force generated during the control process does not need to be monitored, as happens in other controllers such as the clipped-optimal algorithm. Obviously, the main drawback regarding the implementation of the neuro-fuzzy controller is related with the optimization of the inference system. Fuzzy logic controllers are well known for its robustness against parameter variations or model uncertainties. In this context, an important characteristic of this type of controllers is their inherent ability to deal with possible sensor faults or measurement failures, thus enabling the deployment of a framework to design simple robust and reliable control systems with tolerance against sensor failures The damper force and the corresponding control signal are presented in Fig. 15. As can be observed, the control system uses a continuous control signal to command the MR damper. The hysteretic behavior of the MR damper during the numerical simulation is portrayed in the force-displacement and force-velocity plots presented in Fig. 16. The proposed control system is capable to explore the dissipative nature of this type of actuators. -1188-

Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 Fig. 15 - Damper force and corresponding operating current (neuro-fuzzy controller). Fig. 16 - RD-1005-03 MR damper control force (neuro-fuzzy controller). CONCLUSION The present paper presents a neuro-fuzzy controller with acceleration feedback for vibration control of building structures based on MR dampers. Comparing the controlled responses to those obtained in the uncontrolled and passive control systems, it is observed that both passive and semi-active control systems are effective in reducing the seismic responses. However, the semi-active controller allows a more efficient management of the control forces. It is verified that larger damping forces do not always produce better results (e.g., control forces achieved with the passive ON mode are larger than those obtained with the semi-active controller). It can be concluded that the proposed semi-active strategy is an efficient control approach outperforming the passive control modes. The proposed semi-active control system achieves a good performance in reducing the structural responses using only floor accelerations as the reference signals to compute the control action. Moreover, the proposed control system is capable to explore the dissipative nature of this type of actuators. -1189-

Symposium_3 Dynamics, Stability and Control in Structural Engineering REFERENCES [1]-Dyke S.J., Spencer Jr B.F. A comparison of semi-active control strategies for the MR damper, Proceedings of the IASTED International Conference, Intelligent information Systems, 1997, p. 580-584. [2]-Jansen L.M., Dyke S.J. Semi-active control strategies for MR dampers: comparative study, Journal of Engineering Mechanics, 2000, Vol. 125, No. 8, p. 795-803. [3]-Jang J.R. ANFIS: Adaptive-network-based fuzzy inference system, IEEE Transactions on Systems, Man and Cybernetics, 1993, 23(3), p. 665-685. [4]-Schurter K.C., Roschke P.N. Neuro-fuzzy control of structures using acceleration feedback, Smart Materials and Structures, 2001, 10, p. 770-779. -1190-