CMM 900-3W USER GUIDE

Similar documents
Cellular modem and Transceiver

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

ARC Modem Low Power Modem LP9624

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

AT Commands - Trust 56K PCI Modem - Executing commands

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

Sender Receiver Sender

RTU-COM PSTN AT. User Guide

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

Telenetics dial modems are based upon Rockwell chipsets. These chipsets contain Rockwell's "AT" command set.

Remote Maintenance of Controllers via Serial Port

LandCell 819 GPRS Modem. GSM GPRS Serial Cellular Data Modem

Bluetooth RS232 Serial Adapter

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

DIN Rail Mounted Dial-up Modem Users Manual

Bluetooth TO Serial CONVERTER E-P132-B

User Manual for VE GSM Modem

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

User s Manual CDMA Cellular Model CDM819s Serial Modem CDMA Cellular Model CDM819u USB Modem

LM058 Bluetooth Serial Adapter

edbox-100 SmartStack Box for PSTN

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Manual Reference. Modem Commands. S35i, C35i, M35i

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

ICP PANEL-TEC PEX3000 II

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

Bluetooth RS-232 Adapter

ATL20 ATL30 Automatic transfer switch controller

Operation Manual GSM modem irz TG42-232

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

USER MANUAL FOR GS100/GS1003G

Bluetooth V4.1 BLE RS-232 Serial Adapter Model: BLE-232B Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232C

8051SERIAL PORT PROGRAMMING

Instruction Manual Communications Software for iseries and C Series Instruments Part number Apr2014

4.3 Digital Communication

Application Note CTAN #131

Modem AT Command Set

LandCell 819 1XRT Modem. CDMA 1xRTT Serial Cellular Data Modem

Sutron Voice Modem Operation Manual

Select a Data Communication Interface

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AN_2901_005 JULY The Teridian 73M2901CE single chip modem implements the V.23 standard according the ITU V.23 recommendation.

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

Circuit-Switched Configuration for the AirLink Raven Application Note - How To

User Module. AT Modem Emulator APPLICATION NOTE

TELTONIKA ModemCOM (TMC-10x) User Manual V

Universal communications device Metcom T A..

PCL Port RS-232 Interface Card

Chapter 5 AT Commands

irz MC55iT GPRS class 10 GSM modem USER MANUAL

How to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect

APPLICATION NOTE. Using the SUTRON RADAR LEVEL CONTROLLER (RLR ) with a MULTIMODEM GPRS (Wireless Modem MTCBA-G-F4)

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

The Wireless Connectivity Expert

RM024 DVK USER GUIDE VERSION 1.2

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

CTI CALL INFORMATION INTERFACE

EZ864 UMTS Terminal Telit Cellular GSM Engine

GmbH, Stettiner Str. 38, D Paderborn. M-Bus Modem

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

QUICK START GUIDE. M40 Series Cellular modem. Version 1.0

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

TRYMUS. 1. Overview. V.22bis/V.32bis/V.34/V.90/V.92 Modem Module with ISOmodem TM. and Global DAA. TRYMUS Corporation. Feature.

Gemalto EHS6T-USB Terminal Starter Kit. Getting Started Guide

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

3.1 I-7560 Pin Assignment and Specifications: Introduction

Serial Interfacing. Asynchronous Frame

User s Manual. CDMA Cellular Model CDM-820s Intelligent Serial Modem CDMA Cellular Model CDM-820se Intelligent Ethernet Modem

DS Series Manual DATA SWITCH. DS62-MD4 Host-Modem Module QUICK START. BayTech Manual Publication

ISDN OEM1. DesignGuide V1.2

Cytron USB to UART Converter UC00A

RS-232 Serial to Bluetooth Adapter Quick Installation Guide

Dual Serial Shield User Manual

S2C Link Accessory Kit Datasheet

Manual Industry Interfaces

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Section 1 Introduction

RS-422 Code-Operated Switches

WiFi to RS-232 adapter user manual

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

GUIDEBOOK FOR NORBAR DATA TRANSMISSION

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

ISOLATED RS-232 TO RS-422/485 CONVERTER

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Transcription:

CMM 900-3W USER GUIDE AMPS Cellular Modem Module (3W) Page 1 of 1

Table of Contents 1. PRODUCT OVERVIEW...3 1.1 Features:... 3 1.2 Serial Port Pins:... 5 1.3 Applications:... 5 1.4 Your package includes:... 5 2. SPECIFICATIONS...6 3.0 MODEM SETUP AND REGISTRATION...6 3.1 What you need to provide:... 6 3.2 Registering the Cellular Modem Unit:... 6 4. STARTING AND CONFIGURING THE MODEM...7 4.1 DIP Switch Settings:... 7 4.2 Initializing the Cellular Modem:... 7 4.3 Activating the Cellular Modem:... 8 4.4 Using the Cellular Modem to Communicate... 8 5. THEORY OF OPERATION...9 5.1 Command State:... 9 5.1.1 Command guidelines... 9 5.1.2 Result Codes... 11 5.2 On-line State:... 12 5.3 Transitioning Online State Command State:... 12 6. SUPPORTED AT COMMANDS...13 6.1 AT Commands common to all modes:... 13 7. TROUBLESHOOTING...15 8. FREQUENTLY ASKED QUESTIONS (FAQ)...16 9. WARRANTY...18 Page 2 of 2

1. PRODUCT OVERVIEW The Cellular Modem Module, CMM 900-3W, uses the Advanced Mobile Phone System (AMPS) cellular network for data transmission. AMPS is the cellular system used in North America, Latin America, Australia, New Zealand and parts of Africa. AMPS system is not compatible with the digital systems, such as GSM (Global System for Mobile Communications). CMM 900-3W has RS232 interface and supports the popular AT command set normally associated with modems. Optionally TTL interface is also available. Power Supply DIP Switch RS 232 Port Figure 1. CMM 900-3W 1.1 Features: Uses AMPS Circuit Switched Cellular network for data transmission User friendly modem AT command set Choice of TTL or RS 232 serial interface Choice of Hardware or Software Flow Control Incorporates Quiet Mode (Section 6.1) thereby enabling communication with non-intelligent systems Page 3 of 3

Requires 5 Volts DC @ 1500 ma Page 4 of 4

1.2 Serial Port Pins: (RS 232 interface) Figure 2. DB9 Female RS-232 DCE Interface Pin No. Signal Name Input/Output 1 DCD Output 2 RXD Output 3 TXD Input 4 DTR Input 5 GND 6 DSR Output 7 RTS Input 8 CTS Output 9 RI Output 1.3 Applications: Example applications for data communications with CMM 900-3W include: Packet Data Radio SCADA and Telemetry Systems Remote gas/water/electric meter readings. Factory Automation systems Vending Machines 1.4 Your package includes: CMM 900-3W unit (Power supply and antenna are optional) RS 232 Cable (DB9, M-F) This USER GUIDE Page 5 of 5

2. SPECIFICATIONS Air Speed Up to 9600 bps DTE Rate 300, 1200, 2400, 9600, 19200, 57600 bps (DIP switch selectable) Data Compression & Error Detection MNP2-5, V42, V42bis, MNP 10 Transmit Power 3 W Power Supply 5 volts DC @ 1500 ma Interface RS 232 Asynchronous Signals supported TXD, RXD, CD, DSR, RTS, CTS, RI, DTR Operating Temperature Range -10 C to +70 C Custom Configurations Yes 3.0 MODEM SETUP AND REGISTRATION 3.1 What you need to provide: 5 Volts, 1500 ma regulated DC Power Supply Host PC with a terminal program, such as Hyper terminal, ProComm etc. Mobile Identification Number (MIN) provided by your Cellular service provider. MIN is your cellular phone number. System ID (SID) information (from your cellular service provider) SID uniquely identifies your cellular service provider. 3.2 Registering the Cellular Modem Unit: To register your cellular modem unit, do the following: Contact your cellular service provider Provide the cellular operator with the ESN (Electronic Serial Number) number located on the label at the top of your unit. Inform the cellular operator that the unit is an AMPS ONLY ANALOG unit with a power rating of Class 1 (power 3 W). The cellular operator will register your unit and provide you the following information: o MIN (Mobile Number) Number o System preference: A or B o SID (System ID) Page 6 of 6

It is recommended that the MIN and SID information be stored in an easy to access location. 4. STARTING AND CONFIGURING THE MODEM The Cellular Modem is configured as a DCE (e.g. modem). It communicates with a PC through the serial (RS 232) port. 4.1 DIP Switch Settings: DIP Switch Position Note 1 DTE speed 1 ON 300 baud 2 ON 1200 baud 3 ON 2400 baud 4 ON 9600 baud 5 ON 19200 baud 6 ON 57600 baud 7 ON Hardware Handshake 8 ON Software Handshake Note 1: ON = Down position 4.2 Initializing the Cellular Modem: To start the CMM 900-3W unit, perform the following steps: Step 1: Connect the 5V DC power supply. Please take precaution that the polarity of the applied voltage is correct. Step 2: Connect the Cellular Modem to the PC using the RS 232 cable provided. Step 3: Connect the Antenna to Cellular Modem. Step 4: Click the HyperTerminal icon on the PC, or select Start>Programs>Accessories>Hyper Terminal>Hyperterm.exe The Connection Description Dialog Box opens. Step 5: In the name field, enter Cellular Modem and click OK. The Connect To dialog box is now active. Step 6: Select Connect Using and then choose the COM Port that is connected to the Cellular Modem. For example, if the Cellular Modem is on COM 2, choose Direct to Com2 and click OK. Step 7: The COM2 Properties dialog box now opens. Select the following (see section 4.1 for details): bps to match the DIP switch settings on the CMM 900 Data Bits: 8 Page 7 of 7

Parity: None Stop Bits: 1 Flow Control based on the CMM 900-3W switch settings Click OK. Step 8: Select Call>Disconnect Step 9: Select Call>Connect Step 10: Select File>Properties>Settings>ASCII setup Step 11: Check the following: In the ASCII Sending field, check Echo typed characters locally. In the ASCII receiving field, check Append line feeds to incoming line ends and Wrap lines that exceed terminal width. Step 12: Click OK twice. Step 13: Select Call>Disconnect Step 14: Select Call>Connect Step 15: Select File>Save Step 16: Hit <CR> on the keyboard. The Cellular Modem will return OK. This is the indication that the entire hardware setup and configuration is OK. 4.3 Activating the Cellular Modem: To activate, perform the following steps: Step 1: Enter AT+TEST<CR>. The unit responds OK. Step 2: Enter AT+MIN=<Allocated_MIN ><CR> The unit responds OK. Step 3: Enter AT+SID=<Allocated_SID ><CR> The unit responds OK Step 4: Enter AT+SYS=00 <CR> (will select system B only), or =01 <CR> (will select system A only), or =02 <CR> (SID will determine preferred system, however roaming charges may apply). The Cellular Modem does NOT have to be configured every-time. The above information is stored in the Non-volatile memory built in the CMM 900-3W. Step 5: Enter AT+MODE=02<CR> The unit is now set for data mode. Step 6: Enter AT+SER <CR> The unit responds with SERVICE AVAILABLE. 4.4 Using the Cellular Modem to Communicate To use the Cellular Modem to communicate with a modem, perform the following steps: Page 8 of 8

Step 1: Enter ATDT XXXX <CR> XXXX is the phone number of the modem you are calling. After approximately 30 seconds, the Cellular Modem responds with CONNECT message. Step 2: Type Hello The party you called should see the message on their terminal screen. Step 3: Ask the called party to type a message and you should see that message on your terminal screen. Step 4: Enter the Escape sequence +++. The modem responds OK. Step 5: Enter ATH0<CR> The Cellular Modem responds No Carrier indicating that the connection is terminated. Step 6: Ask the called party to dial your MIN number. Cellular Modem responds with CONNECT message after approximately 30 seconds. Step 7: Repeat steps 2 to 5. 5. THEORY OF OPERATION The cellular modem is always in one of the following two states: Command state, or Online state 5.1 Command State: The Cellular Modem assumes the Command state when it is turned ON. In this state, you can configure the unit for a particular application. In the Command State, all inputs from the PC are treated as commands. 5.1.1 Command guidelines Command line is a string of characters sent from the DTE (example - PC) when the unit is in the Command state. All commands must conform to the following guidelines. Command lines must have a prefix, a body and a terminator Command lines must begin with a character sequence AT Command Lines must end with Carriage return (CR) Either all upper case or all lower case characters must be used Each command must be entered separately. Command buffer has 40 characters. Page 9 of 9

Note: Commands entered incorrectly or with out-of-range parameters will result in an ERROR message. Commands entered correctly will result in OK message. Page 10 of 10

5.1.2 Result Codes Result Codes refer to the responses of the cellular modem unit to a command. Unless the cellular modem has been programmed to be in the Quiet mode (Section 6.1), the unit will respond each time a command is issued. The default mode of the cellular modem is the verbose mode. The responses in the verbose mode are characters. Using AT commands, the modem can be put into terse (non-verbose) mode. The responses in non-verbose mode are numerical digits. Various modem responses are shown below: Terse Mode Verbose Mode Description 0 OK Command executed without errors. 1 Connect Connection at 300 bps 2 Ring Ringing signal detected 3 No Carrier Carrier lost or never present 4 Error Invalid command 5 Connect 1200 Connection at 1200 bps 6 No Dial tone Cellular service not available 7 Busy Called party on-line 8 No Answer 9 Connect 0600 10 Connect 2400 11 Connect 4800 12 Connect 9600 13 Connect 7200 66 Compression class 5 Connection established MNP- 5 67 Compression V42bis 68 Not used 69 Compression none 76 Protocol: none 77 Protocol: LAPM 99 Service Unavailable Cellular Service not available 100 Service Available Unit ready for communication Page 11 of 11

5.2 On-line State: In Online state, input(s) from the PC is treated as data to be transmitted over the airwaves, and input(s) from the airwaves is treated as received data from the remote end. The cellular modem is in online state in one of the two conditions: Cellular modem dials out and a successful connection is established. Cellular modem answers an incoming call and a successful connection is established. When the cellular modem is in Online state. All serial data presented to the radio is transmitted over the air. DO NOT change communication parameters (e.g. baud rate) in this mode. To go back to Command State, Escape Sequence (described below) is required. 5.3 Transitioning Online State Command State: The sequence of characters to transition from Online State to the Command State is called the escape sequence. For cellular modem, the escape sequence is +++. The timing interval between the + signs must be between 250 msecs and 750 msecs. When the cellular modem receives a valid escape sequence, the modem will enter Command State and respond with OK. Page 12 of 12

6. SUPPORTED AT COMMANDS This section describes the basic AT commands used to configure the cellular modem. These commands are a subset of the commands used in typical high-speed modems. A command line is a string of characters sent from the DTE (e.g. a PC) while the modem is in Command State. A command line has a prefix, a body and a terminator. Each command line must begin with a character sequence AT and must terminate with a carriage return. The Radio starts the processing of commands only after AT string sequence is received. Commands entered with out of range parameters will result in ERROR message. Correct commands will result in OK message in verbose mode, and 0 in terse mode. 6.1 AT Commands common to all modes: Command Action ATZ<CR> Resets the modem. The unit responds with OK message ATO<CR> Go on-line. This is done after the state of the unit is changed from on-line to command state. ATO then puts the unit back into online state. ATDT XXXX <CR> Cell modem dials out. XXXX is the phone number AT+TEST <CR> Puts the unit in test mode. Note: The commands AT+SYS, AT+MIN, AT+SID and AT+ID can be entered only when the unit is in the Test Mode. AT+SYS=xx<CR> Sets system preference. SYS =00 sets the unit for system B only SYS =01 sets the unit for system A only SYS =02 is for normal mode. SID determines preferred system SYS =03 is for home use only AT+RSSI<CR> Indicates the Received signal strength. Should be > - 100 dbm for reliable communication. AT+SER <CR> Indicates if service is available. AT+MIN=XXXXX<CR> Sets the MIN number. The modem responds OK AT+SID=XXXX<CR> Sets SID. Modem responds OK Command Action AT+ID?<CR> Displays ESN, MIN, SID, System Preference Page 13 of 13

information. Note: MIN, ESN, SID information are stored in the Non-volatile memory of the cell-modem and do not need to be entered on every Powerup. To exit Test mode, enter AT+MODE=02<CR> ATQ1<CR> Unit does not respond with OK or non-verbose messages. This is ideal for in situations where the Data Link is connected to a non-intelligent host. This mode is also called Quiet Mode. ATQ1&W&W1 Q1 instruction stored in non-volatile memory. AT&V<CR> Displays settings of the cell modem ATI3<CR> Displays Software Revision # ATH0 Modem disconnects and initializes. ATV0 Unit responds in terse mode. Results code is displayed as digits ATV0&W&W1 Above command stored in non-volatile memory. On power-up, the modem will be in terse mode. ATV1 Unit responds in verbose mode. Results codes are displayed as messages. ATV1&W&W1 Above command stored in non-volatile memory. On power-up, the modem will be in verbose mode. ATS0 Default is 0. If 0, then the unit will not answer incoming call. Please use ATS0=1&W&W1 to have the unit answer incoming calls. +++ Escape Sequence. The Radio will respond with OK on detection of valid escape sequence. When the modem is on-line state, it is possible to break the data transmission/reception. This is achieved by sending a sequence of three ASCII characters. For ease of use, the default character is +. Page 14 of 14

7. TROUBLESHOOTING 1. If the unit draws too much power. Please ensure that the correct power supply is used and correctly wired. 2. If dialing out is repeatedly unsuccessful and the modem gives NO DIAL TONE message, please check that the mobile service is available. 3. If the unit never connects on dialing out, please ensure that the ESN (Electronic Serial Number) and the MIN numbers are correct. 4. Please check RSSI level. If it is low (< -95 dbm), positioning the antenna vertically should improve it. 5. If remote landline modem connection drops frequently, please have the calling party set S7=60 & S10 register to 200. This will make the modem more tolerant of the noise hits. This can be done as follows: ATS0=1S7=60S10=200&W&W1<CR> If for some reason, the CMM 900-3W unit is not responding, please try the command: AT&F&W&W1 <CR> Whenever the command AT&F&W&W1 is issued, then you must do the following ATS0=1\N2+MS=11,1,1200,2400X3&W&W1 <CR> AT-SEC=1,15&W&W1 <CR> If that also fails, power down the unit and power it up again. Also see next section on FAQ. Page 15 of 15

8. FREQUENTLY ASKED QUESTIONS (FAQ) Q1: What is the flow control method recommended? A1: If the host is a PC, Hardware flow control is recommended. However, in most control instrumentation, either software or no flow control is called for. Q2: How do I disable any flow control? A2: Simply disable both the Hardware and software control switch settings. This is not recommended for large file transfers. Q3: I need to connect the Cellular Data Link to a machine, which does not understand your messages. All it needs is data. Which configuration is recommended? A3: Please use the ATQ1&w&w1<CR> command. Q4: Have you experienced unreliable communication with certain modems? A4: Yes. Several generic brands tend to throw hot signals (i.e. strong signal levels) on the line. This causes the cellular service to over-modulate, which leads to distortions and results in unreliable connections. Q5: What is the solution? A5: We recommend that you use modems that support MNP-10 and also allow transmit level to be reduced to between 15 dbm 20 dbm. Rockwell based modem designs generally meet these requirements. For Rockwell based modems, please try the following commands on the land line modem: AT-SEC=1,18 <CR>. This will enable MNP 10 and set transmits level to 18 dbm. AT+MS=11,1,1200,2400X3&W&W1<CR>. Sets the modem to communicate between 1200 and 2400 bps. Q6: Is there any simple way to avoid frequent loss of connection? A6: Please program the CMM 900-3W as follows AT+MS=11,1,1200,1200&W&W1<CR> This will force the CMM 900-3W to connect only at 1200 bps. Q7: What initialization string is recommended to communicate with non-mnp modems? A7: Connection with non-mnp landline modems is not recommended. Page 16 of 16

Q8: Is there any recommended init string for various land line mode. A8: The following have been tried with excellent results. a) For US Robotics / 3 Com modems: ATS10=200&A3&B1&N2&U2&W&W1 <CR> b) For Rockwell chip set based land-line modems 33600 and lower AT%E2\N2S7=60S10=200+MS=11,1,1200,2400&w&w1 <CR> c) For most other brands: ATN0S37=6S10=200&w&w1 <CR> d) For Rockwell chip set based land-line modems 56K V90 models AT%E2\N2S10=200S7=60+MS=V34,1,1200,2400,1200,2400 <CR> Q9: My requirement(s) are totally unique. Do you offer custom solutions? A9: Yes. Page 17 of 17