Product and functional description

Similar documents
Product and functional description

Product and functional description

Product and functional description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Push Button Interface UP 220D31

Product and functional description

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Product and Application Description

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and Applications Description

Operating and mounting instructions

Push button UP 287, 4 - fold

252F 5WG FB_1 DELTA

DELTA i-system wall switch single UP 221/2 5WG AB_2

584 5WG AB_1 DELTA

Product and Application Description

Product and Function Description

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Weather station GPS AP 257/61 Weather station AP 257/51

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Weather station AP 257/51

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

1-channel shutter actuator 6A UP Installation Instructions

Power supply module, bus connection module

The LED display (1) turns green when the load is switched on.

Operating voltage Maximum

picture 1: Device components

Product and function description

Digital input modules

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

MINI-PS AC/10-15DC/8

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Operating Instructions. DALI-Gateway

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

KNX DALI Gateway Plus - User Manual

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

Miniature Circuit Breakers for Railway Applications

CC COMPACT DIP SWITCH

is then retained absolutely without interruption.

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

TXM1.8RB. TX-I/O Blinds module

SITOP in the SIMATIC Design

ABB i-bus KNX Binary Inputs BE/S Product Manual

Use of the application program

Installation and User Guide

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Extension module for lighting control

Electronic timer CT-ERD.12

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Power Supply HARTING pcon

Solid State Remote Power Controller E /627

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

DALI Professional Controller-4. Control unit Operating instructions

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Operating instructions Evaluation system for flow sensors VS / / 2013

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Signal Doublers. VariTrans A 20300

LED Driver Linear / area dimming

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Operating instructions. Speed monitor D / / 2014

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Operating instructions. Switching amplifier DN0210 DN / / 2015

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Transcription:

Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control, i.e. for switching and dimming resistive, inductive or capacitive loads from 20 to 300 A at 230 AC, 50-60 Hz. The bus is connected via a bus terminal and the power supply for the electronics is provided by an integrated 230 AC power supply unit. Connecting universal dimmer submodules You can connect a universal dimmer submodule N 528/41 (dimmable load 20-300 A), a universal dimmer submodule N 527/41 (dimmable load 20-500 A) or a universal dimmer submodule N 527/51 (dimmable load 20-1,000 A) with the 2-pin interface T+, T- (see, for example, device B in figure 1) using a twisted pair of wires. Up to 5 universal dimmer submodules can be connected to a universal dimmer main module, in which the twisted pair T+, T- is also to be looped from interface to interface. In this way, a main module can be extended if required from a KNX dimmer with one output to a KNX dimmer with up to 6 outputs. When connecting a new universal dimmer submodule to a universal dimmer main module, it is essential that you connect their 2-pin interfaces T+/T- first before applying the mains voltage to the submodule(s). This is the only way to guarantee that the communication between main module and submodule(s) takes place correctly. The lines T+ and T- are to be installed safely isolated from the 230 potential. The maximum permitted line length between the main module and the submodule furthest away is 2 m. Figure 1. Connection example Device address You set to which dimming channel (B...F) of the main module the relevant submodule is to be assigned with a rotary switch on the underside of the housing (see A1 in figure 2). A universal dimmer main module must always be set on channel A. If two or more devices are set incorrectly to the same address, then the light emitting diodes (LED) for the relevant channels will flash. Siemens AG N 528/31, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 2.5.1.17/1

Figure 2. Rotary switch for device address Dimming loads from 40 to 2,000 A The outputs from two N 527/51 universal dimmer submodules (dimmable load each 20-1,000 A) can be connected in parallel, in order to be able to dim a load in the range from 40-2,000 A (see devices E and F in figure 1). A1 You must not connect the outputs of more than two N 527/51 devices in parallel. Parallel operation of the outputs from universal dimmer main modules with each other or with a submodule, as well as of all other universal dimmer submodules, is not permitted! LED indications 6 bi-color (red/green illuminating) light emitting diodes (LED) on the top of the main module (see figure 3, B8) indicate which module was selected (LED illuminates green if the output is switched off and illuminates red if the output is switched on). If any of the LED A...F flashes, then an error has been detected on this module. This is the case, for example, if more modules are configured than are actually connected, the configured module type is incompatible with the module type actually connected, the same device address has been set more than once or if a module was detected as defective. Switching between bus mode and direct mode You use the "Direct mode" pushbutton (see figure 3, B6) to switch between "Bus mode" and "Direct mode". If this button is held down for at least 3 seconds, then the yellow LED (see figure 3, B7) comes on permanently to indicate direct mode. In direct mode, you select a module (channel) and switch and dim it with the two pushbuttons (see figure 3, B5) on the top of the main module. A module (channel) is selected if the "Direct mode" pushbutton (see figure 3, B6) is tapped several times until the LED for the wanted module A...F flashes (red or green according to the current switching status). Modules in which an error is indicated in bus mode by a green flashing LED A...F cannot be switched or dimmed in direct mode. The corresponding LED goes out when switching on the direct mode. You use a parameter to set whether direct mode can be switched on permanently or for a limited time. At the factory, direct mode is set to a timed on-time of 15 minutes. Each time the pushbutton is operated in direct mode, the timer for on-time limiting is restarted. After the on-time has elapsed without a further press of the pushbutton, direct mode switches off automatically and thus "Bus mode" is re-enabled (if communication over the bus is possible). Alternatively, direct mode can be ended at any time by pressing the "Direct mode" pushbutton again for at least 3 seconds. The yellow LED for indicating direct mode then goes out and the actuator is again in bus mode. In bus mode, pressing the pushbutton to switch an output on or off directly has no effect. When direct mode is switched on, switching, dimming value and scene recall commands received via the bus are buffered and will be executed automatically after the return to bus mode, i.e. the last received switch-/ dimming command received is then executed and the scenes are recalled in the received sequence. Pushbutton inputs E1, E2 A conventional pushbutton can be connected each to the E1 and E2 inputs of the main module for direct switching and dimming of the output A. Tapping the pushbutton on the E1 input leads to switching on, holding it down to dimming brighter, tapping the pushbutton on the E2 input leads to switching off, holding it down to dimming darker. You use a parameter to set whether pressing one of the buttons is also to lead to sending switching and dimming telegrams via the bus to other actuators. On electrical safety reasons, both pushbuttons must be connected to the same phase conductor as the dimmer module in question. Application program The universal dimmer main module N 528/31 needs the application program "07B0 A6 Universal dimmer 982101", which is configured and loaded with the Engineering Tool Software (ETS) from ersion ETS 3.0 f onwards. This controls the outputs both from the main module and all connected sub-modules. Inter alia, it includes monitoring of each channel for short circuit, overload and overheating, switching and dimming status reporting, a warning before switching off, time functions, blocking and releasing a channel, a configurable behaviour at bus voltage failure and recovery, as well as at mains voltage recovery, and an integrated 8-bit scene control in which each channel can be integrated in up to 8 scenes. Behaviour at voltage failure / recovery Because the power for the main module's electronics is generated via an integrated 230 AC power supply unit, a mains voltage failure means that the affected module also fails. In the event of a mains voltage failure at the Technical Manual N 528/31, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Electrical Installation Technology 2.5.1.17/2

main module, night mode is ended if it is active and the current switching states and dimming values of all modules (channels) are stored permanently, in order that they can be regenerated automatically after mains voltage recovery. You use a parameter to configure the behaviour after mains voltage recovery: switching on all channels, switching off all channels, restoring the switching / dimming states of all channels at mains voltage failure. However, if night mode was active before mains voltage failure, this will not be re-enabled. A mains voltage failure exclusively at a submodule results as well in switching off this channel as in the complete failure of this module. The submodule will remain switched off after mains voltage recovery if the main module didn t receive any switching or dimming commands for this module during mains voltage failure at it. Otherwise the main module will transmit the last meanwhile received switching / dimming command to the submodule after mains voltage recovery at this module. In contrast, a bus voltage failure results only in a communication failure via the KNX bus. But communication between the main module and all connected submodules via the interface T+ / T- is unaffected by this. Each module retains its current status. If pushbuttons for direct switching and dimming are connected to a module's pushbutton inputs E1, E2, you can use these connected buttons to switch and dim this module. You can also select each module (i.e. each channel) with the pushbuttons on the top of the universal dimmer main module and switch and dim in direct mode. Parameters are used to set the behaviour in each case on bus voltage failure and on bus voltage recovery. Technical specifications Power supply Bus voltage: provided via the bus line Bus current: typically 7 ma, max. 10 ma. Electronics: - integrated power supply for 230 AC, + 10 % / - 15 %, 50-60 Hz Mains supply Rated voltage: 230 AC, +10% / -15%, 50-60 Hz Rated current: 1.3 A Power loss if output A = OFF: 1.3 W, maximum power loss at trailing edge dimming: 2.0 W, maximum power loss at leading edge dimming: 4.6 W. Pushbutton inputs 2 inputs Rated voltage: 230 AC, 50-60 Hz Maximum length of the connecting cable: 100 m Load output Rated voltage: 230 AC, 50-60 Hz Rated current: 1.3A Connection output at 45 C ambient temperature: - Incandescent lamps: 20...300 W - High voltage halogen lamps: 20...300 W - Low voltage halogen lamps with electronic transformers: 40...300 A - Low voltage halogen lamps with magnetic transformers: 20 300 A - Osram dimmable energy-saving lamps: 1...5 units 15 A resp. 20 A Short circuit / overload protection Electronic protection, i.e. the universal dimmer cuts off if there is a short circuit or overload. After resolving the short circuit / overload, the universal dimmer can be reconnected by switching off and on again or by interrupting the mains voltage until a period of at least 2 minutes has elapsed. Temperature rise protection Electronic protection, i.e. the universal dimmer dims to the minimum dimming value if the maximum permitted temperature is exceeded. When the excess temperature has fallen to below the maximum permitted value, the universal dimmer reverts to the previous dimming value after 2 minutes. Connecting mixed loads to the same output (both inductive and capacitive loads, e.g. a group of low voltage halogen lamps with magnetic transformer, together with a group of low voltage halogen lamps with electronic transformer or together with dimmable energy-saving lamps) is not permitted. Low voltage halogen lamps with an electronic transformer may only be used in mixed operation together with incandescent lamps and high voltage halogen lamps. Magnetic transformers may only be used if they comply with the relevant standards and contain a thermal fuse. Low voltage halogen lamps with a magnetic transformer may only be used at the same output together with incandescent lamps and dimmable energy-saving lamps from Osram if the parameter "Load matching" has been set from "Automatic load matching" to "Leading edge mode". With Osram's dimmable energy-saving lamps, the parameter "Load matching" must be set from "Automatic load matching" to "Leading edge mode and the parameter "Minimum dimming value" to a value > 20%. Siemens AG N 528/31, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 2.5.1.17/3

Operating elements 1 commissioning pushbutton: for toggling between normal / addressing mode 1 pushbutton: for toggling between bus / direct mode 2 pushbuttons: for switching and dimming the selected channel in direct mode Display elements 1 red LED: for checking the bus voltage and for displaying normal mode / addressing mode 1 yellow LED: for displaying direct mode / bus mode 6 bicolor LED (red and green): for status indication of the 6 channels A F Connections Mains, load and pushbuttons connections: Screw-type terminals, insulation strip length 7... 9 mm. The following conductor cross-sections are permitted: - 0,5... 4.0 mm² single core, - 0,5... 2.5 mm² finely stranded, without / with connector sleeve KNX bus line: Bus terminal block, screwless, conductor cross-section 0.6 0.8 mm Ø single core, insulation strip length 5 mm Submodule: Low voltage terminal block, screwless, conductor cross-section 0.6 0.8 mm Ø single core, insulation strip length 5 mm, maximum length of cable between modules A and F: 2 m Mechanical data Housing: plastic Dimensions: device for DIN-rail mounting with N-system dimensions, width 3 MU (1 Module Unit = 18 mm) Weight: approx. 130 g Fire load: approx. 2470 kj Installation: Snap-on mounting on DIN rail EN 60715-TH35-7.50 Electrical safety Degree of pollution (according to IEC 60664-1): 2 Protection type (according to EN 60529): IP 20 Overvoltage category (according to IEC 60664-1): III Bus: safety extra-low voltage SEL DC 24 Device complies with: EN 50428 EMC requirements complies with EN 50428 Reliability Failure rate: 893 fit at 40 C Markings KNX EIB CE mark In accordance with the EMC guideline (residential and functional buildings), low voltage guideline Environmental conditions Climatic withstand capability: EN 50090-2-2 Ambient operating temperature: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (not condensing): 5 % to 93 % Technical Manual N 528/31, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Electrical Installation Technology 2.5.1.17/4

Position and function of the display and operating elements Mounting and wiring Installation notes The device can be used for permanent installation in dry interior rooms and for insertion in control cabinets or small distribution boards. Mounting and dismounting the device: see figure 4 and figure 5 B2 B1 Figure 3. Display- / operating elements B1 Plug for bus connection terminal block B2 Plug for low voltage terminal block for connecting universal dimmer submodules B3 Pushbutton for switching between normal mode and addressing mode for transferring the physical address. B4 LED for indicating normal mode (LED Off) or addressing mode (LED On); it turns off automatically after transferring the physical address B5 Pushbuttons for switching and dimming the selected device (output) in direct mode B6 Pushbutton for selecting a device (output) and for toggling between bus and direct mode B7 LED (yellow) for indicating direct mode = On B8 LEDs (bicolor) for indicating via a steady light whether the selected device (output) is switched on (red) or off (green) or is defective (flashing light) B9 Screw terminals for connecting / looping the N-conductor B10 Screw terminals for connecting / looping the L-conductor B11 Screw terminals for connecting the load B12 Screw terminals for connecting in each case a pushbutton for direct switching and dimming of the load connected to the output Figure 4. Mounting on a DIN-rail C1 C2 Figure 5. Dismounting from a DIN-rail Connecting and disconnecting the bus line: see Figure 6 D2 D2.1 D2.2 D2 D2.3 D2 D2.4 5mm D2 D2.4 D1 Figure 6. Attaching / removing the bus terminal Siemens AG N 528/31, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 2.5.1.17/5

Connecting a universal dimmer submodule: see figure 7 Snap the universal dimmer submodule on to the DIN-rail and interconnect the T+ and T- connections from the universal dimmer main module and the universal dimmer submodule via a twisted pair of wires. After this connect the AC power line and switch the mains voltage on. Connecting the twisted pair T+ / T-: see figure 6 (commensurate with the bus line) This device contains a varistor. Due to a disruption of the neutral conductor, overvoltage or conventional transformers running at no load, damage may arise which can lead to the failure of the device at a later date. The conductors (outer and neutral conductor) are to be connected with each other for dielectric tests. For dielectric tests of cables, which measure core against core contrary to the current valid norm DIN DE 0100 T. 610, the device must be disconnected, because otherwise it may be damaged. When connecting the device, it should be ensured that the device can be isolated. The device must not be opened. For planning and construction of electrical installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Dimension drawing Dimensions in mm Figure 7. Connecting universal dimmer submodules The system may only be installed and commissioned by an authorized electrician. If the phase conductor connected to the device is to be looped to one or more submodules, then the phase conductor is to be fused with a miniature circuit breaker with B or C characteristic for a rated current of 16A, in order that the maximum permissible terminal current is not exceeded. If the main module and the submodules connected to it are to be used on more than one phase, then the third harmonics of the load currents are summed in the jointly fed neutral conductor. In this way, the neutral conductor can be loaded more heavily than the phase conductors. The neutral conductor in this case is to be rated adequately or protected against excessive current, as there may otherwise be a fire risk. Running magnetic transformers at no load is prohibited both on start-up and in operation, because this may lead to damage to the device (even when the dimmer has cut off). This is to be ensured by connecting at least two lamps or transformers in parallel to an output. Failed lamps are to be replaced immediately. The device may only be operated vertically with the ventilation slots at the top and at the bottom. The device must be well ventilated. Heat dissipation must be ensured. b b = 3 MU 90 General notes 44 55 45 1 Module Unit (MU) = 18 mm The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office to: Siemens AG, Siemensstr. 10, D-93055 Regensburg If you have further questions concerning the product, please contact our Technical Support: +49 (0) 180 50 50-222 (0,14 /min. from the German landline network, deviating mobile communications prices are possible) +49 (0) 180 50 50-223 E-Mail: support.automation@siemens.com Internet: www.siemens.com/automation/service&support Technical Manual N 528/31, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Electrical Installation Technology 2.5.1.17/6