Agilent 86121A WDM Channel Analyzer

Similar documents
Agilent Technologies E5385A 100-Pin Probe

87421/22A Power Supply. Operating and Service Manual

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Agilent OBSAI Protocol Tester

Agilent N1022A Active Probe Adapter User Guide

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Keysight 86120D and 86122C Multi-Wavelength Meters. User s Guide

Precise Fiber Couple Laser Light Source

HP 87050A Option H42 Multiport Test Set

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Installation and Quick Start Guide

Firmware Guide. Keysight PXIe Chassis Family

Agilent 855xxA Series CalPods and 85523A CalPod Controller

Agilent Technologies U3020AY03

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Agilent Gb/s Serial BERT

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Quick Start/Installation Guide

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Installation Guide. Agilent Technologies E8663B Analog Signal Generator

* * Agilent Power Distribution Unit (PDU) Installation Guide

Agilent 70612B K18 Switch Matrix

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

Agilent 86122C Multi-Wavelength Meter User's Guide

Agilent N4219B Packet Analysis Probe for Serial ATA. User s Guide

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

User s Manual. AQ6150/AQ6151 Optical Wavelength Meter IM AQ EN. 1st Edition

User's Guide. Model High Precision Quad Output DC Power Supply

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

MODEL 805 USER MANUAL

Agilent 86122B Multi-Wavelength Meter Getting Started Guide

Agilent X-Series E6607B Wireless Communications

1690-Series Logic Analyzers

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

High Precision Quad Output DC Power Supply

Installation Note. Agilent ESG and ESG-D Series Signal Generators Add Option 1E5 Upgrade Kit Kit Part Number E

Agilent 86122B Multi-Wavelength Meter User's Guide

1-36V, 0-3A DC Power Supply

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

HP E2485A. Installation Guide. Memory Expansion Interface. Copyright Hewlett-Packard Company 1997 All Rights Reserved

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

Agilent Softtouch 2.0 Midbus Probe

DVI Extender over single LC Fiber with TMDS video and EDID data.

Broadband Automatic Disconnect Switch. User Manual

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent N4880A. Reference Clock Multiplier. User s Guide

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information

burst laser

Line Impedance Stabilization Network (LISN)

1. PRODUCT INTRODUCTION Description 1-2. Feature...

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Cary 50. Pre-Installation Manual

E5504B E18 Phase Noise Measurement System

86100 Series Infiniium DCA Oscilloscope

Universal AC Power Source + AC Power Analyzer

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

GM8012 Optical Power Meter. User Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

FOOT CONTROLLER FCV100

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

DVI Extender over Fiber with EMI Shielding

Keysight N5102A Baseband Studio Digital Signal Interface Module

Agilent Technologies LogicWave

HV-CS kv Edge Mount Triaxial Jack

Master Oscillator Power Amplifier SLD System MOPA-SLD-850

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Installation and Quick Start Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

EOS-6000 Series Optical A/B Switch User Manual DC Version

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent OpenLAB Chromatography Data System (CDS)

About this Manual. Support for Your Product

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

RZ5/RZ5D/RZ6 Processor. Operator s Manual

Keysight PNA Series Network Analyzers. Installation and Quick Start Guide

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

9040/9040UK. Users Manual. Phase Rotation Indicator

Keysight Add Source and Receiver Attenuators Upgrade Kit

User s Guide. 600A AC Clamp Meter. Model 38387

Model 2380 Rack-Mount Kit

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

SCSI HP Administrator s. Vectra PCs Guide. Kayak PC

fax hp LaserJet 3330mfp

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP Software Revision Controller/XL Technical Addendum

User's Guide. Extech AM A AC Analog Clamp Meter

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Transcription:

Quick Reference Agilent 86121A At a Glance 2 WDM Channel Analyzer Display 3 Agilent 86121A Front Panel 7 Agilent 86121A Rear Panel 8 Measuring Wavelength and Power 9 Changing the Units and Measurement Rate 11 Defining Laser-Line Peaks 12 Measuring Laser Separation 13 Measuring Laser Drift 14 Measuring Signal-to-Noise with Averaging 14 Measuring Total Power Greater than 10 dbm 15 Calibrating Measurements 16 Setting the Date and Time 17 Saving and Printing the Measurement Results 18 Softkey Menus 19 Safety Information 23 Agilent 86121A WDM Channel Analyzer

Agilent 86121A At a Glance The Agilent 86121A WDM channel analyzer measures the wavelength and optical power of laser light in the 1270 1650 nm wavelength range. Because the Agilent 86121A WDM channel analyzer simultaneously measures multiple laser lines, you can characterize wavelength-division-multiplexed (WDM) systems. Laser Classification This product is classified FDA Laser Class I (IEC Laser Class 1) laser. Safety Considerations Please review all laser and other safety considerations in the Agilent 86121A User s Guide. Line Power Requirements Line Power Requirements Power: Voltage Frequency 115 VAC: 110 VA MAX. / 60 WATTS MAX. / 1.1 A MAX. 230 VAC: 150 VA MAX. / 70 WATTS MAX. / 0.6 A MAX. nominal: 115 VAC / 230 VAC range 115 VAC: 90 132 V range 230 VAC: 198 254 V nominals: 50 Hz / 60 Hz range: 47 63 Hz 2

WDM Channel Analyzer Display Display after the front-panel Run key is pressed. 3

Selected line Delta Annotation The Delta display. 4

The Drift display. 5

The S/N with Averaging display. 6

Agilent 86121A Front Panel Agilent 86121A WDM channel analyzer front panel. 7

Agilent 86121A Rear Panel Agilent 86121A WDM channel analyzer rear panel. 8

Measuring Wavelength and Power To limit the wavelength measurement range 1 Press the Setup key. 2 Press the WL LIM softkey. 3 Press the STARTWL softkey to adjust the start wavelength value and then press RETURN when you are done. 4 Press the STOP WL softkey to adjust the stop wavelength value and then press RETURN when you are done. To measure broadband devices and chirped lasers 1 Press the Setup key. 2 Press MORE twice, and then the DEVICE softkey. 3 Press the BROAD softkey.to return to measuring narrowband devices, press NARROW and then press RETURN. To see the graphical display 1 Press the GRAPH softkey. 2 To exit the graphical display, press any softkey. To save an instrument state 1 Press the Setup key. 2 Press the SAV/RCL softkey. 3 Press the SAVE softkey. 4 Press one of the four SAVE softkeys to save the instrument state. To recall an instrument state 1 Press the Setup key. 2 Press the SAV/RCL softkey. 9

3 Press the RECALL softkey. 4 Press one of the four RCL softkeys to recall an instrument state. To control the power bar 1 Press the Setup key. 2 Press MORE twice, and then PWR BAR. 3 Press BAR ON to display the power bar, and press BAR OFF to hide the power bar display. 10

Changing the Units and Measurement Rate To change the units of measure 1 Press Setup. 2 Press the MORE softkey. 3 Press the WL UNIT softkey. 4 Select one of the following units. Then, press RETURN to complete your selection: NM for nanometers THZ for terahertz To change the measurement speed 1 Press the Setup key. 2 Press the MORE softkey. 3 Press the UPDATE softkey. 4 Select either NORMAL or FAST. 11

Defining Laser-Line Peaks To define laser-line peaks 1 Press the Setup key. 2 Press the THRSHLD softkey. The peak excursion value can range from 1 to 30 db. The default value is 15 db. 3 Press PK EXC, and enter the peak excursion value. Use the softkey to select the digit that requires editing. Use the and softkeys to change the value. 4 Press RETURN. 5 Press PK THLD and then enter the peak threshold value. The peak threshold value can range from 0 to 40 db. Setting this value to 0 db ensures that only the peak wavelength is identified. The default value is 10 db. Pressing the green PRESET key changes the peak excursion and peak threshold values to their default settings. It also turns wavelength range limiting on. Cycling the power off and then on does not change these settings. 12

Measuring Laser Separation To measure delta channel separation 1 Press the front-panel Delta key. 2 Select the type of separation to observe: WL displays channel separation. PWR displays differences in power. WL / PWR displays both channel separation and differences in power. 3 Use the and softkeys to select the reference laser line. 4 Press SELECT. Press SELECT at any time to select a new reference. Press RESET at any time to turn off the delta calculation. To measure flatness 1 Press the front-panel Delta key. 2 Select PWR. 3 Use the and softkeys to select the laser line with the greatest power level. 4 Press SELECT. Since the largest power signal is the reference, the relative power measurements for the other responses shows system flatness. You can use relative power measurements to measure flatness (pre-emphasis) in a WDM system. Simply select one carrier as the reference and measure the remaining carriers relative to the reference level. The power differences represent the system flatness. Press RESET to turn off the delta calculations so that all responses are shown in absolute wavelength and powers. 13

Measuring Laser Drift To measure drift 1 Press the front-panel Drift key. Pressing DRIFT sets the current laser-line values as the reference from which to compare all drift. 2 Press MAX-MIN for the desired type of drift measurement. Measuring Signal-to-Noise with Averaging To measure signal-to-noise with averaging 1 Press the front-panel S/N key. 2 To change the number of averages, press NUM AVG. The default value is 100 averages. 3 To stop the measurement at the current number of averages shown, press the front-panel Stop key. Then press the front-panel Run key to continue the present measurement. 4 When the measurement is complete, the instrument will stop. 5 To make a new measurement, press the Run key. 6 To exit, press the EXIT softkey, then press the Run key to return to continuous measurement. 14

Measuring Total Power Greater than 10 dbm To measure total power exceeding 10 dbm 1 Connect an optical attenuator between the frontpanel OPTICAL INPUT connector and the fiber-optic cable. The attenuator must reduce the total input power to the 86121A so that it is below +10 dbm. 2 Press Setup, MORE, CAL, and then PWR OFS. Notice that the PWR OFS annotation appears on the screen to indicate an offset is applied. 3 Use the softkey to select the digit that requires editing. 4 Use the and softkeys to change the value. Power offset values are added to the display power readings. For example, if you placed a 10 db attenuator on the front-panel connector, enter a power offset value of +10 db. Negative values can also be entered if you connect an amplifier instead of an attenuator. 15

Calibrating Measurements To enter the elevation 1 Press the Setup key. 2 Press the MORE softkey. 3 Press the CAL softkey. 4 Press ELEV. 5 Use the and softkeys to enter the elevation in meters. Entries jump in 500 meter steps from 0 m to 5000 m. In order for the WDM channel analyzer to meet its published specifications, the elevation value selected with the softkeys must be within 250 meters of the actual elevation. 6 Press RETURN to complete the entry. Converting feet to meters If you know your elevation in feet, you can convert this value to meters by using the following equation: ft m = -------------- 3.281 16

Setting the Date and Time To set the date and time 1 Press the Setup key. 2 Press the MORE softkey. 3 Press the MORE softkey again. 4 Press the CLOCK softkey. 5 Press DATE to adjust the year, month and day. Press RETURN when you are done. 6 Press TIME to adjust the hour, minute and seconds. Press RETURN when you are done. 17

Saving and Printing the Measurement Results To save measurement results 1 Press the DISK hardkey. The softkeys that will appear are STORE and RETURN. 2 Press STORE to save the data to a file on the disk. Press RETURN to return to the previous state. To create a hardcopy on an external printer To print using an external printer, connect a compatible printer to the rear-panel PARALLEL PRINTER PORT connector. The output is ASCII text. An example of a compatible printer is an HP * LaserJet series printer. Be sure to use a parallel printer cable to connect the printer. 1 Press the PRINTER key. The softkeys that appear are INTERNL, EXTERNL, PRINT, and RETURN. 2 Select EXTERNL printer. The active printer will be in inverse video. 3 Press PRINT to begin printing. You can press ABORT to stop the print job in progress. *. HP is a U.S. registered trademark of Hewlett-Packard Company. 18

Softkey Menus The Startup menu These softkeys are visible when the instrument is started up. Signal-to-Noise measurement menu The Signal-to-Noise measurement softkeys are accessed by pressing the front-panel S/N key. Drift measurement menu The Drift measurement softkeys are accessed by pressing the front-panel Drift key. 19

Delta measurement menu The Delta measurement softkeys are accessed by pressing the front-panel Delta key. 20

Setup menu 21

Disk menu Printer menu 22

Safety Information This product has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. The instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition. Laser Classification This product is classified FDA Laser Class I (IEC Laser Class 1) laser. 23

WARNING WARNING If this instrument is not used as specified, the protection provided by the equipment could be impaired. This instrument must be used in a normal condition (in which all means for protection are intact) only. No operator serviceable parts inside. Refer servicing to qualified personnel. To prevent electrical shock, do not remove covers. Table 0-1. There is no output laser aperture The Agilent 86121A does not have an output laser aperture. However, light less than 1 nw escapes out of the front-panel OPTICAL INPUT connector. Operator maintenance or precautions are not necessary to maintain safety. No controls, adjustments, or performance of procedures result in hazardous radiation exposure. Input Connector 24

If you should ever need to clean the cabinet, use a damp cloth only. WARNING WARNING To prevent electrical shock, disconnect the Agilent 86121A from mains before cleaning. Use a dry cloth or one slightly dampened with water to clean the external case parts. Do not attempt to clean internally. This is a Safety Class I product (provided with a protective earthing ground incorporated in the power cord). The mains plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor inside or outside of the instrument is likely to make the instrument dangerous. Intentional interruption is prohibited. CAUTION This product has autoranging line voltage input. Be sure the supply voltage is within the specified range. CAUTION Ventilation Requirements. When installing the product in a cabinet, the convection into and out of the product must not be restricted. The ambient temperature (outside the cabinet) must be less than the maximum operating temperature of 25

the product by 4 C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be used. CAUTION This product is designed for use in INSTALLATION CATEGORY II and POLLUTION DEGREE 2, per IEC 1010 and 664 respectively. CAUTION The front panel LINE switch disconnects the mains circuits from the mains supply after the EMC filters and before other parts of the instrument. CAUTION Install the instrument so that the ON/OFF switch is readily identifiable and is easily reached by the operator. The ON/ OFF switch or the detachable power cord is the instrument disconnecting device. It disconnects the mains circuits from the mains supply before other parts of the instrument. Alternately, an externally installed switch or circuit breaker (which is readily identifiable and is easily reached by the operator) may be used as a disconnecting device. CAUTION Install the instrument according to the enclosure protection provided. This instrument does not protect against the ingress of water. This instrument protects against finger access to hazardous parts within the enclosure. 26

Copyright Agilent Technologies 2000 All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under copyright laws. Agilent Technologies Lightwave Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403-1799, USA (707) 577-1400 Notice. The information contained in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise noted. Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Restricted Rights Legend. Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies. 27

HP Part No. 86121-90005 Printed in USA February 2000 28