Advanced materials research using the Real-Time 3D Analytical FIB-SEM 'NX9000'

Similar documents
JSM-7900F. Scientific / Metrology Instruments. Schottky Field Emission Scanning Electron Microscope. Ultimate Analytical tool

Introduction of Hitachi SU1510

SEM topography. Live quantitative surface topography in SEM

ZEISS Launches New High-resolution 3D X-ray Imaging Solutions for Advanced Semiconductor Packaging Failure Analysis

QUANTAX EDS SYSTEM SOP

Non-destructive, High-resolution Fault Imaging for Package Failure Analysis. with 3D X-ray Microscopy. Application Note

Fuel Cell Preparation. The anode supported SOFC studied was Ni-YSZ/YSZ/LSM-

STEM electron tomography in the Scanning Electron Microscope

Scanned by CamScanner

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

HKL Flamenco EBSD Data Acquisition Flow

Image Acquisition Systems

QUANTITATIVE PHASE IMAGING OF BIOLOGICAL CELLS USING OFF-AXIS METHOD OF WIDE FIELD DIGITAL INTERFERENCE MICROSCOPY (WFDIM)

Layout Analysis I/O. Analysis from an HD Video/Audio SoC

Layout Analysis Embedded Memory

The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct

Evex NanoAnalysis EDS Acquisition

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

JSM-IT100 Series. InTouchScope. Scientific/Metrology Instruments. Scanning Electron Microscope

Natural Viewing 3D Display

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

A SUPER-RESOLUTION MICROSCOPY WITH STANDING EVANESCENT LIGHT AND IMAGE RECONSTRUCTION METHOD

FEI Helios NanoLab 600 TEM specimen prep recipe Nicholas G. Rudawski (352) (office) (805) (cell) Last updated: 07/16/18

ENVISION A NEW WAY OF COMBINED COMPETENCIES

ZEISS Software Module Catalog Extend the Functionality and Performance of Your Microscope

Digital Image Processing

Guide to operate the FEI Scios FIB/SEM equipped with EDAX EDS/EBSD --- Elemental and texture analysis using EDS/EBSD

SUPPLEMENTARY INFORMATION

Crystal Quality Analysis Group

MATERIALS CHARACTERIZATION FACILITY

The same X-ray transparent in situ pouch cell design and sample holder plates were used for both 2D

diffraction patterns obtained with convergent electron beams yield more information than patterns obtained with parallel electron beams:

Confocal Raman Imaging with WITec Sensitivity - Resolution - Speed. Always - Provable - Routinely

XRADIA microxct Manual

Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

Development of Reflector for HR-TFTs

12/7/2012. Biomolecular structure. Diffraction, X-ray crystallography, light- and electron microscopy. CD spectroscopy, mass spectrometry

Optical Ptychography Imaging

Delayline Detectors. Imaging Detection of Electrons, Ions & Photons with Picosecond Time Resolution. e - I +

Marco Cantoni, Pierre Burdet

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

Introduction to Biomedical Imaging

UNIVERSITY OF PLYMOUTH

Direct acquisition of interferogram by stage scanning in electron interferometry

Digital Volume Correlation for Materials Characterization

BME I5000: Biomedical Imaging

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

3D Energy Dispersive Spectroscopy Elemental Tomography in the Scanning Transmission Electron Microscope

Cover Page. The handle holds various files of this Leiden University dissertation

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

Supporting Information: FIB-SEM Tomography Probes the Meso-Scale Pore Space of an Individual Catalytic Cracking Particle

Microscope and visualization equipment. Studentská 1402/ Liberec 1 tel.: cxi.tul.cz

INCAGSR. Gun Shot Residue

Inspection System for High-Yield Production of VLSI Wafers

Single-particle electron microscopy (cryo-electron microscopy) CS/CME/BioE/Biophys/BMI 279 Nov. 16 and 28, 2017 Ron Dror

SmartSoft AES Operator s Guide

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Continuous Imaging Fluid Particle Analysis: A Primer

Supporting Information

Versatile laser Raman Spectrometer. RMP-500 series

Quality control phantoms and protocol for a tomography system

X-ray thin-film measurement techniques

CHEM-E5225 :Electron Microscopy Imaging I

SCDI for EUV photomask metrology RESCAN - Reflective EUV Mask Scanning Lensless Imaging Tool

Supporting Information for Critical Factors of the 3D Microstructural Formation. in Hybrid Conductive Adhesive Materials by X-ray Nano-tomography

Scanning Capacitance Microscopy Investigations of Focused Ion Beam Damage in Silicon

[HALL PROBE GRADIOMETRY ]

3. Image formation, Fourier analysis and CTF theory. Paula da Fonseca

JEOL CarryScope SEM Revision /07/17 Page 1 of 7. JEOL CarryScope SEM

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy

Endcap Modules for the ATLAS SemiConductor Tracker

Fast Reconstruction of CFRP X-ray Images based on a Neural Network Filtered Backprojection Approach

6-1 LECTURE #6: OPTICAL PROPERTIES OF SOLIDS. Basic question: How do solids interact with light? The answers are linked to:

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

An Inspection and Measurement Technology Platform Leading the Way to More Advanced Manufacturing

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

Packaging Technology for Image-Processing LSI

Chapter 3. Experimental Procedure

Exam Microscopic Measurement Techniques 4T th of April, 2008

COMPARISON BETWEEN CONVENTIONAL AND TWO-DIMENSIONAL XRD

FlexAirConnecT Dust Insensitive Multi-Fiber Connector with Low Loss and Low Mating Force

Focused Ion Beam Micro Machining and Micro Assembly

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Product Information Version 1.1. ZEISS Xradia 510 Versa Submicron X-ray Imaging: Maintain High Resolution Even at Large Working Distances

The Determination of Inner Surfaces in Composites by X-Ray Refraction

Plane Wave Imaging Using Phased Array Arno Volker 1

NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes

CCD Image Acquisition Tutorial

Simulation of Internal Backscatter Effects on MTF and SNR of Pixelated Photon-counting Detectors

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Structural Information obtained

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

3. Scanning BRILLOUIN microscopy

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

LUSI SUB-SYSTEM XCS Physics Requirements for the LUSI Large Offset Monochromator. Doc. No. SP R0

Transcription:

SCIENTIFIC INSTRUMENT NEWS 2017 Vol. 9 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Advanced materials research using the Real-Time 3D Analytical FIB-SEM 'NX9000' Yo Yamamoto 1. Introduction Hybrid instruments that combine focused ion beam (FIB) methods with scanning electron microscopy (SEM) are valuable sample-fabrication tools that offer capabilities such as cross-sectional observation, transmission electron microscopy (TEM), and atom-scale probes of materials. They are used in a wide range of fields for structural analysis of materials such as metals, semiconductors, hybrid materials, and soft materials. In recent years, methods of 2D analysis including observations of sample surfaces and analysis of local regions via TEM and other methods have become insufficient for analyzing the structure of materials, which increasingly requires 3D analysis of mesoscale regions. For this reason, there is a growing need for 3D structural analysis based on continuous cross-sectional observation methods using FIB-SEM. To address this, Hitachi High-Tech has developed high-performance FIB-SEM instruments and the Cut&See method for continuous cross-sectional observations. This method continuously alternates FIB processing of evenly-spaced sample slices with in-situ SEM observations. The continuous SEM images thus obtained are then superposed on a computer at the intervals used for the FIB slicing step, yielding a 3D reconstruction of the structure. Moreover, because this method uses continuous cross-sectional SEM images, the spatial resolution of the 3D reconstruction is not affected by the thickness of the observed sample an issue that is problematic for TEM analysis offering the advantage of allowing high-resolution 3D analysis independent of sample thickness. In addition, this may be also utilized for the 3D elemental mapping or 3D crystal orientation mapping, by combined with analyzing method, such as energy-dispersive X-ray spectroscopy (EDS) or electron back-scattering diffraction (EBSD). However, in general-purpose FIB-SEM systems, the FIB and SEM instruments are aligned at an angle to each other (this angle is 54 for Hitachi High-Tech instruments) to accommodate samples of various sizes., Therefore the direction of SEM observations is tilted with respect to the sample cross section. This can give rise to shifts in position during continuous cross-sectional processing, and differences in the horizontal-to-vertical aspect ratio of captured images, in which case the reconstructed structure does not necessarily match that of the original sample. In addition, the structure of FIB-SEM systems forces some unavoidable sacrifice of imaging performance compared to what is possible with a single SEM system, thus leaving some room for improvement. Also, the layout of conventional FIB and SEM systems ensures that the various detectors are not positioned optimally with respect to the sample, which places a variety of limitations on the system s ability to capture in-situ continuous cross-sectional images (i.e.. real-time 3D analysis). At Hitachi High-Tech we have transcended these traditional approaches to FIB-SEM system design by developing the NX9000 FIB-SEM Real-Time 3D Analyzer, an instrument boasting an orthogonal layout in which the FIB and SEM systems are aligned at a 90 angle to each other, and the positions of the lens barrel, the sample stage, the detectors, and other elements are optimized to solve all of the problems mentioned above. In this report, we discuss the key features of the NX9000 for 3D analysis and present sample applications involving analysis of semiconductor devices and batteries. Hitachi High-Technologies Corporation All rights reserved. 2017[42]

2. Design of the NX9000 Figures 1 and 2 show a photograph of the NX9000 and a schematic diagram of its internal structure, respectively. The instrument is equipped with a newly developed cold-cathode field-emission scanning electron microscopy (cold FE-SEM) lens barrel. In addition, to fully extract the SEM performance in observing FIB-processed cross sections, the FIB lens barrel is aligned perpendicular to the SEM at an optimized working distance (WD) of 4 mm. This improves the image resolution of SEM observations at the beam crossing point (CP) compared to tilted FIB-SEM systems, and also allows real-time SEM observations via vertical irradiation of the sample cross section. This eliminates the artifacts of conventional tilted FIB-SEM noted above position shifts during continuous cross-sectional processing and horizontal-to-vertical aspect-ratio variations due to the tilted observation allowing faithful reconstruction of the 3D structure of the sample. In addition, the instrument includes a miniature sample stage equipped with a high-precision scale, allowing a significant reduction in system drift. This allows high-stability, high-precision continuous FIB cross-sectional processing with continuous SEM cross-sectional observations, enabling high-quality 3D structure observation using the Cut&See method. Also, miniaturizing the sample holder allows the system to enter a low-drift state immediately after sample placement, improving throughput for 3D observations. Finally, by optimizing the relative positions of the sample, lens barrels and the various detectors including the SEM electron detector and the EDS and EBSD detectors we have made it possible to obtain signals from various detector systems at the CP, allowing not only the structure of the sample but also 3D information on properties such as material composition and crystal structure to be gathered simultaneously. Fig. 1 The NX9000 Fig. 2 Schematic diagram of the internal structure of the instrument Hitachi High-Technologies Corporation All rights reserved. 2017[43]

3. Features and functions of the NX9000 In what follows we present the key features and functionality of the NX9000. 3.1 Optimized real-time observation of SEM images FIB-processed sample cross sections may be observed in-situ via SEM images captured vertically, offering even higher resolution and contrast. In addition, vertical irradiation by the electron beam improves the horizontal-to-vertical aspect ratio of the resulting images, allowing information on the dimensions of samples to be obtained with greater accuracy than with conventional approaches. Using a commercial 2X NAND flash-memory sample, we compared SEM cross-sectional images captured by the NX9000 and by a conventional tilted FIB-SEM system. The results are shown in Figure 3. Figures 3(a) and 3(b) are secondary-electron images obtained at the location of the CP under identical beam conditions using the conventional system and the NX9000, respectively. Because the orthogonal alignment of the lens barrel allows the internal design of the NX9000 to be optimally arranged, cross-sectional images observed in-situ exhibit accurate horizontal-to-vertical aspect ratios and improved resolution and contrast compared to those obtained by conventional methods. (a) (b) Fig. 3 Cross-sectional SEM images of a flash-memory sample (a)image observed with a conventional tilted system (b)image observed via vertical irradiation using the NX9000 Hitachi High-Technologies Corporation All rights reserved. 2017[44]

3.2 Highly reproducible automated continuous slicing In addition to the high-performance sample processing made possible by the FIB lens barrel, the inclusion of a lowdrift miniature sample stage allows the NX9000 to achieve highly reproducible slice processing. This enables Cut&See automated continuous operation with intervals on the order of nanometers for long periods of time in a stable state. Figure 4 shows the results of tests to verify the reproducibility of slice processing using a commercial 2X NAND flash-memory sample. We set the step size for continuous slice processing to 1 nm and considered 6 processing patterns involving repeated STI/Si steps, simultaneously observing SEM images. We used the continuous SEM images thus obtained to reconstruct an image of the YZ cross section and measured the number of processing slices produced by the repeated pattern. The results indicate an average of 48 slices per pitch with fluctuations (σ) of 1 slice or less. This demonstrates the extremely high precision and reproducibility of the continuous slice processing capability of the NX9000. (a) (b) Pattern No. Slice number #1 49 #2 49 #3 49 #4 47 #5 48 #1 #2 #3 #4 #5 #6 #6 48 Average 48 σ 0.8 Fig. 4 Reproducibility of slice processing (a)continuous cross-sectional SEM images (b)reconstructed image of YZ cross section and number of processed slices for the repeating patterns Hitachi High-Technologies Corporation All rights reserved. 2017[45]

3.3 Real-time observations using a variety of detector systems The standard NX9000 comes equipped with one secondary-electron detector in the sample chamber (lower SED), In-column secondary-electron detector (upper SED), and In-column backscattered-electron detector (BSD), and images can be captured by these detectors simultaneously. Figure 5 shows an example in which the surface of a lithium-ion battery material was observed by the various detectors. Images captured by the lower SED, the upper SED, and the BSD are shown in Figures 5(a), 5(b), and 5(c), respectively. Each image exhibits characteristic features: the lower-sed image highlights surface roughness, the upper-sed image highlights the state of the surface including the fine-grained surface structure and the electrostatic potential and the BSD image highlights the material composition. The simultaneous capture of all three images demonstrates the ability of the NX9000 to obtain multiple types of information including surface morphology, finegrained structure, and material composition simultaneously. In 3D FIB-SEM observations, cross-sectional FIB processing and cross-sectional SEM observations are performed continuously; because these are destructive processes, it is important to obtain multiple types of information simultaneously during the measurement. Figure 6 shows examples of 3D observations of a fuel-cell electrode material as captured using the simultaneous three-detector capture capabilities of the NX9000. This sample has a three-phase structure consisting of YSZ, Ni, and voids (filled with resin). For structural analysis, these three phases must be separated and analyzed. This would be difficult to do using images from just a single detector, but here it is readily accomplished thanks to the ability of the NX9000 to capture images from three detectors simultaneously. Thus, by exploiting simultaneous image capture from three detectors each offering distinct features, all available information is captured from the sample and an accurate 3D structure is obtained. Conductive reinforcer (carbon black), binders, etc. LiCoO active material Fig. 5 Imaging the surface of a lithium-ion battery material (a) Lower SED image (b) Upper SED image (c) BSD image Hitachi High-Technologies Corporation All rights reserved. 2017[46]

Upper SED BSD Lower SED Ni + YSZ YSZ Void YSZ Ni Void Fig. 6 Example of a 3D observation of fuel-cell electrode material using simultaneous image capture by multiple detectors 3.4 Using Multi-Cut&See for high-resolution 3D structural analysis with wide field of view In materials analysis, acquiring knowledge about the fine-grained structure of a material requires high-resolution observations. High-resolution observations are achieved by using high magnification factors in SEM observations; however, this reduces the area of the observed region. For materials or biological samples that exhibit random structures, not only high-resolution observations of localized regions are required, but also observations over wide sample areas, in order to elucidate the relationship between these regions and their surroundings. However, high-resolution observations over wide fields of view require large image-acquisition times and produce large volumes of data. For example, if we wish to obtain an image with a field of view of 100 100 μm and a resolution of 5 nm, the number of data points acquired that is, the number of pixels in the image is 20,000 20,000, and the measurement will require enormous amounts of time and data storage capacity. To alleviate this difficulty, Hitachi High-Tech has developed Multi-Cut&See as a tool for high-resolution 3D analysis with wide fields of view. With this capability, the position and spatial extent of the image acquired for each cross-sectional surface during continuous cross-sectional observations may be chosen arbitrarily, and multiple images may be acquired. This allows not only acquisition of high-resolution images of a sample region at high magnification, but also wide field-of-view observations of the surrounding region at low magnification. Hitachi High-Technologies Corporation All rights reserved. 2017[47]

Figure 7 shows an example in which Multi-Cut&See was used to observe mouse brain cell tissue. In this example, the number of pixels per image is 1,000 1,000, and images were acquired with fields of view of 5, 10, and 100 μm. This allows acquisition of continuous images at a high resolution of 5nm and continuous images spanning a wide area of 100 μm in the same region. In this case, the total number of pixels is 1,000 1,000 3. Compared to acquiring an image with a 100 μm field of view at 5 nm resolution, this method reduces both time and data volume by more than a factor of 100, yielding an extremely efficient data-acquisition technique. Field of view: 100 μm (Pixel resolution: 100 nm) Field of view: 10 μm (Pixel resolution: 10 nm) Field of view: 5 μm (Pixel resolution: 5 nm) Fig. 7 High-resolution, wide field-of-view image of mouse brain cell tissue obtained using Multi-Cut & See 3.5 3D-EDS/3D-EBSD analysis In combination with Cut&See, continuous EDS elemental mapping (3D-EDS) and continuous EBSD crystalorientation mapping (3D-EBSD) data may be acquired automatically with no need to move the sample stage. This allows stable acquisition of 3D structural, composition, and crystal-orientation data, leading to a system for producing a thorough portfolio of 3D data for materials analysis. Figure 8 shows an example of a 3D-EDS analysis involving a fuel-cell electrode material (Ni-YSZ). EDS mapping allows accurate separation of elements in the various phases within the sample interior (Zr, O, Ni, and voids), enabling analysis of their 3D distribution. Figure 9 shows an example of a 3D-EBSD analysis involving a Ni-based metallic material. By optimizing the alignment of EBSD, FIB, and SEM, there is no need to move the sample stage between the continuous cross-sectional processing and measurement phases, allowing acquisition of stable, continuous maps of crystal orientation. Hitachi High-Technologies Corporation All rights reserved. 2017[48]

C O 5μm Ni Zr Fig. 8 Example of a 3D-EDS analysis Sample: Fuel-cell electrode material (Ni-YSZ) Mapping acquisition interval: 100 nm Number of mappings: 212 Fig. 9 Example of a 3D-EBSD analysis Sample: Ni SEM accelerating voltage: 20 kv Mapping acquisition interval: 150 nm Number of mappings: 150 Hitachi High-Technologies Corporation All rights reserved. 2017[49]

4. Summary In this report we have presented the key features and functions of the Real-Time 3D Analytical FIB-SEM 'NX9000', a new instrument developed by Hitachi High-Tech to meet the growing need for FIB-SEM-enabled analysis systems for collecting 3D information on mesoscale material regions. Through a series of practical case studies, we demonstrated that the NX9000 paired with our Cut&See package is an extremely powerful tool for 3D structural analysis of materials, and is expected to be widely adopted for various fields. Acknowledgements Fuel-cell electrode samples (Ni-YSZ) were provided by Professor Naoki Shikazono of the Institute of Industrial Science, the University of Tokyo. Mouse nerve-tissue samples were provided by Associate Professor Yoshiyuki Kubota of the Division of Cerebral Circuitry, National Institute for Physiological Sciences. To both we extent our deepest gratitude. Publication data Published in the monthly journal Engineering Materials (September issue 2017) Authors Yo Yamamoto Beam Technology Systems Design Department Hitachi High-Tech Science Corporation Hitachi High-Technologies Corporation All rights reserved. 2017[50]