Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Similar documents
SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

A low-cost, economical solution for distribution feeder protection

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

SEL Protection and Communications Capabilities Integral to Power System Upgrade at Alberta s Dynamic Northlands Park

Automation Services and Solutions

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Advanced distribution feeder solution with integrated protection, monitoring, and control

Lightweight and flexible recloser control for single-phase applications

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Utility Implements Communications- Assisted Special Protection and Control Schemes for Distribution Substations

SEL Real-Time Automation Controller (RTAC)

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Comprehensive protection for large, medium, and small generators

High-speed transformer differential protection for up to five terminals

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

2 ms arc-flash protection and feeder relay in one platform

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

750/760 Feeder Management Relay Instruction Manual

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SEL-400 Series TiDL Quick-Start Guide

Protect induction and synchronous motors with one relay.

2 ms arc-flash protection and feeder relay in one platform

CASE STUDY. Wind Farm in Mexico Completes First Successful IEC Application With Multivendor Interoperability

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Spectra RMS Circuit Breakers with microentelliguard Trip Units

Numerical Protective and Management Relays

SEL-587Z High-Impedance Differential and Overcurrent Relay

SEL Time-Domain Link (TiDL ) Technology

SEL-321 Data Sheet. Phase and Ground Distance Relay, Directional Overcurrent Relay, Fault Locator

Getting Started With SEL-3555 RTAC

OrionLX. An Overview of the OrionLX Product Line

Getting Started With the SEL-3505/SEL

Smart Distribution Technology

GE Multilin 350 Feeder Protection Relay Specifications

PRC System Protection Coordination Supplementary Reference

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power System Network Simulator (PSNsim)

IED (Intelligent Electronic Device)

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Bus Bar Protection Relay B-PRO 4000

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Maximize process uptime with the SEL-patented motor thermal model.

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

URC Utility Relay Company

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

IDM DATA ACQUISITION SYSTEM

DNP Points List and Implementation

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

DNP Points List and Implementation for Universal Controls

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

QUICK START GUIDE Generator Protection Unit GPU 300

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

SEL-551/SEL-551C Overcurrent and Reclosing Relay

UNITROL F Excitation systems for synchronous machines with and without rotating exciter

Source-Transfer Application Guide

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

Lecture 5 Substation Automation Systems. Course map

BE1-951 OVERCURRENT PROTECTION SYSTEM ADVANTAGES

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

SEL Products and Features Make Integration Easy

Distribution Substations Relaying

High-Speed Railroad Operations

SEL-387E Current Differential and Voltage Protection Relay

The Smart Utility Meets The Smart tgid Grid. The Smart. Bob Uluski. Technology Quanta Technology LLC

Powerful and flexible recloser control for many popular reclosers

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

Lecture 6 Substation Automation Systems

Synchrophasor Fact Sheet

Substation SCADA Monitoring

Designing a new IEC substation architecture

SCADA Training - T&D Automation

S Reclosers. Contents. Form 6 Microprocessor-Based Rack Mount Recloser Control Installation and Operation Instructions

SEL-2414 Transformer Monitor

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Airfield Lighting Control System

Sacramen Sacr t amen o t Municipal Utility Dis t Dis rict t SMUD May Ma 10,

SEL University. Power Through Knowledge. Dr. Héctor J. Altuve Ferrer Dean of SEL University

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

SECTION APPENDIX B SFC DOCUMENT SUBMITTAL SCHEDULE

Single-Phase Testing of the SEL-487E Differential Element Without State Simulation

Orion. An Overview of the Orion Automation Platform

The Power of Modern Relays Enables Fundamental Changes in Protection and Control System Design

Built for speed, security, and simplicity

1 Description of Methodology for Volt / Var Optimization

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

NPW800R RETROFITTING. Power and Volatge Protection Relay

NovaTech Orion I/O Overview

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

DNP Points List and Implementation

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER

Protect induction and synchronous motors with one relay

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Transcription:

SEL Distribution Substation Protection and Automation System Protection, Monitoring, and Control System for Distribution Substations Data Sheet SYSTEM ONE-LINE RELAY TARGETS ALARM HISTORY SYSTEM COMM. On-Line Documentation LOG ON LOG OFF 10:49:46 AM 10/19/99 SUBSTATION INFO RELAY FAILURE ENTRY ALARM 24 DC VOLTS PROTECTION OVERVIEW TRANSFORMER 12 MW 0 MVAR SUDDEN PRESS REMOTE HIGH SIDE BREAKER 65 63 65 OVER TEMP NITROGEN PRESS BUS VOLTS REMOTE MAIN BREAKER 24,939 AB 299 24,956 BC 24,958 CA 296 299 REMOTE R REMOTE R REMOTE R REMOTE R G G G G FEEDER 1 150 75 FEEDER 2 47 FEEDER 3 23 FEEDER 4 144 71 51 26 151 75 49 23 Date Time State Oper Cmt Val Oct 19 1999 10:48:21.168 UNACK Main Breaker VBAT Modbus Integer 0 Oct 19 1999 10:48:21.168 UNACK Main Breaker Breaker Operate Main Open Oct 19 1999 10:48:21.168 UNACK ACK DS-ES0001 GENERAL DESCRIPTION This pre-engineered system provides protection, monitoring, and control for typical distribution substations. This simple and affordable system uses SEL digital relays and communications processors along with a Human-Machine Interface (HMI) implemented with off-the-shelf, industry-recognized HMI software to provide full-featured protection and basic automation functions. Communications to a remote HMI or Supervisory Control and Data Acquisition (SCADA) system and dial-in/dial-out capability (manual or automatic) are also supported. SCHWEITZER ENGINEERING LABORATORIES 2350 NE Hopkins Court! Pullman, WA! 99163-5603! USA Phone: (509) 332-1890! Fax: (509) 332-7990 E-mail: info@selinc.com! Internet: www.selinc.com

DESIGN CONCEPT SEL has created standard designs for the protection scheme, relay settings, communications processor application, metering and monitoring functions, control functions, and HMI. These designs take advantage of the protection, monitoring, metering, and control capabilities built into SEL relays. By using proven designs, the individual system design effort and documentation costs are reduced. The designs can be scaled up or down, and tailored to meet specific substation and customer requirements. Contact SEL for solutions tailored to your requirements. FUNCTIONAL SUMMARY Protection The system includes fast bus tripping to clear distribution bus faults in cycles, complete backup relaying, and breaker failure protection in addition to transformer differential protection and feeder overcurrent protection. Lockout functions are implemented for breaker failure, bus faults, and transformer faults. Relay logic detects uncommanded changes, e.g., changes in circuit breaker position not initiated through the HMI or relay front-panel control. Monitoring and Metering Monitoring and metering are provided through the digital relays. The SEL-351 Relay meters bus voltage, real and reactive transformer power, and substation DC voltage, and collects discrete alarm indications. Control Control is implemented through the relays, with the local HMI providing the operator interface in the substation. HMI or SCADA systems can provide control from remote locations. Control switches can be placed in the substation as a means of manual control. Programmable logic controllers and RTUs are not required. Self-Checking The relays and communications processors continuously perform self-checks. If a problem is detected, an alarm will appear on the HMI. In addition, the health of each communications channel within the substation is continuously checked by the communications processor and reported to the HMI. Local and Remote Human-Machine Interface The local HMI is implemented on a personal computer with off-the-shelf, industry-recognized HMI software. Protection functions are not dependent on the availability of the PC. The local HMI continuously reports substation status and provides a control interface to the substation equipment. During maintenance periods, two levels of safety tagging are provided. Screens to aid the operator are built in. These include a protection one-line diagram, communications system screen, relay target emulation screen, and customizable help screens that can include customer documents. A remote HMI can also be provided. The remote HMI is similar to the local HMI but at a location remote from the substation. 2

SCADA Interface The system communicates with a SCADA system through a port on the SEL-2030 Communications Processor using Modbus RTU, Modbus Plus, or DNP 3.0 Level 2 protocols. SEL will work with you or your SCADA vendor to implement the communications interface. Please contact SEL if other protocols are involved. Event Reporting and Oscillography The operator can view an oscillographic display of the currents and, if available, voltages from any relay. The relays automatically collect and store the data whenever a fault occurs. The SEL-5601 Analytic Assistant Software displays the data on the substation PC. FEATURES LEGEND Power Circuit Instrument Transformer Circuit Communication Channel LINE DIAL IN/OUT TO REMOTE HMI/SCADA SEL-587 SEL-551 LOCAL HMI SEL-2030 SEL-351 SEL-551 SEL-551 SEL-551 SEL-551 DS-ES0002 Figure 1: One-Line Diagram Example System 3

Protection Two-Winding Transformer:!" Primary protection harmonically restrained percentage current differential and high-set unrestrained current differential!" Backup protection phase and ground SEL-551 Relay!" Backup protection phase and ground SEL-587 Relay Distribution Bus:!" Primary protection - Fast Bus Tripping!" Backup protection - phase and ground SEL-587 Relay!" Backup protection - phase and ground SEL-351 Relay!" Breaker failure detection that trips the high-side circuit breaker for a main circuit breaker failure Distribution Feeders:!" Primary protection - phase and ground nondirectional time overcurrent!" Backup protection - phase and ground SEL-351 Relay!" Automatic reclosing!" Breaker failure detection that trips the main circuit breaker for feeder circuit breaker failure Control Circuit Breaker (Trip/Close) Lockout for:!" Transformer faults!" Bus faults!" Breaker failure trips!" Uncommanded change of circuit breaker position (momentary change detection) Feeder Reclosing (On/Off) Feeder Ground Relaying (On/Off) Local/Remote Control Selection Relay Target Reset Caution Tag (Reclosing Off) Clearance Tag (Control Disabled) 4 Human-Machine Interface Desktop Substation PC with Microsoft Windows NT Workstation 4.0 Operating System Wonderware InTouch Software License Four Levels of Password Security Screens:!" System One-Line Diagram!" Relay Targets!" Alarm History!" System Communications!" On-Line Documentation (Including Customer Provided Documents)!" Simplified Protection One-Line Diagram!" Circuit Breaker Control (one per circuit breaker)!" Caution Tag (one per circuit breaker)!" Clearance Tag (one per circuit breaker) SEL-5010 Relay Assistant Software SEL-5020 Settings Assistant Software for SEL Communications Processor SEL-5601 Analytic Assistant Software HyperTerminal Software (comes with Microsoft Windows NT Workstation 4.0 Operating System, for transparent connections to relays) Metering and Monitoring Transformer Currents (high side and low side) Real and Reactive Transformer Power Feeder Currents Distribution Bus Voltages Transformer Alarms (discrete points) Substation Alarms (discrete points) Substation DC Voltage Relay Front-Panel Targets Major Equipment (Example System): Five SEL-551 Relays One SEL-587 Relay One SEL-351 Relay One SEL-2030 Communications Processor One Desktop Substation PC Services and Documentation Application of Customer Provided Relay Settings Using SEL Standard Relay Setting Templates

SEL-2030 Communications Processor Settings Telephone Support During Installation and Commissioning System Documentation Consisting of:!" Operator training manual!" Maintenance and troubleshooting manual!" System overview!" System installation and startup notes!" Written description of protection system operation!" Simplified substation one-line diagram including relays, communications processors, communications channels, and local HMI!" Simplified AC and DC schematic diagrams for the protection scheme!" Relay settings specification sheets!" Detailed communications block diagram!" HMI operating instructions!" Equipment instruction manuals!" HMI application on CD-ROM as installed on substation PC!" Relay settings in SEL-5010 files on CD- ROM, and in paper copy, as installed on substation PC!" Communications processor settings in SEL-5020 files on CD-ROM, and in paper copy, as installed on substation PC!" Bill of material!" Software licenses!" Software manuals!" Non-SEL equipment warranties Optional Features and Services Enhanced Distribution Bus Protection, Monitoring, and Control:!" Directional overcurrent relaying!" Over- and undervoltage relaying!" Over- and underfrequency relaying!" Voltage sag/swell monitoring!" Load shedding and restoration Enhanced Feeder Protection, Metering, Monitoring, and Control:!" Directional overcurrent relaying!" Over- and undervoltage relaying!" Over- and underfrequency relaying!" Voltage sag/swell monitoring!" Real and reactive power metering!" Demand metering!" Load shedding and restoration Three-Winding Transformer Protection Transmission Line Protection Pre-Wired Racks Pre-Fabricated Control Houses Fault Studies, Protection Design, and Relay Settings Remote Human Machine Interface Interface with SCADA via Modbus, Modbus Plus, or DNP 3.0 Level 2 Protocols SEL-351S Breaker Control Systems or SEL-351R Recloser Control Systems with Large Pushbutton Operator Interface FOR ADDITIONAL INFORMATION This system is one example of SEL s approach to providing practical, capable, and cost effective protection and automation. SEL would be pleased to tailor a Protection and Automation System to fit your needs. To discuss your particular application, including any additional or special features, please contact us through your local SEL representative, field application engineer, or the SEL Customer Service Representative. Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA USA 99163-5603 Tel: (509) 332-1890 Fax: (509) 332-7990 We are interested in any questions you may have about this or other SEL products and systems. We appreciate receiving any comments and suggestions about new products, product improvements, or system features that would help us make your job easier. 5

All brand or product names appearing in this document are the trademark or registered trademark of their respective holders. Schweitzer Engineering Laboratories, SELOGIC, Connectorized, and are registered trademarks of Schweitzer Engineering Laboratories. Copyright SEL 1999 (All rights reserved) Printed in USA. SEL Distribution Substation Protection and Automation System Date Code 991221