MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

Similar documents
TPE, TPED Series 2000

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

Technical Manual Room temperature controller

Installation and Maintenance Manual IM

Installation Guide. Expansion module 1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Installation, Start-up and Operating Instructions

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

Chore-Tronics IDM Board Instruction

I/O module (Expansion module)

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Digital Photo Frame With Alarm Clock Model DPF-363

WARNING ELECTRICAL SHOCK HAZARD

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

Operating instructions. Switching amplifier DN0210 DN / / 2015

AutoScan to MultiScan Replacement Kit

Semi flush-mounted room temperature controllers with LCD

Operating instructions IO-Link master CabinetLine AL19xx

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ

Page 1. Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL

Supplementary operating instructions for your air curtain system Controller TMC 500

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

TT /12b INSTALLATION INSTRUCTIONS. Introduction

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

WARNING ELECTRICAL SHOCK HAZARD

Semi flush-mounted room temperature controllers with LCD

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

Modular Room Control (MRC) Series Expansion Board

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

User Guide. Online.

FleetPhone. Installation guide. The mobile satellite company

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

P216. Condenser fan speed controller. Product bulletin. Features

Semi Flush-mount Room Temperature Controllers with LCD

MAKING MODERN LIVING POSSIBLE. Flashing Manual. CD302 and CDS302. Manual

/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500

Installation and Operation Manual SPC1

Installation Instructions

Installation and Operation Manual DPC1

FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

Installation manual plugs and connectors with screw connection (16/32 A)

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

F210A IP Camera. Hardware User Manual

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

hp uninterruptible power system r12000 xr models installation instructions

Operating instructions. Speed monitor D / / 2014

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Assembly and Operating Instructions Door Control

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL For authorized service personnel only.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Operating Manual FPGA-based High-Speed Micro-PLC

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Series 3000V Input/Output Board

FREQUENCY CONVERTER FC101 (QUICK GUIDE)

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Installation and Setting up Instructions for the Type 920 Auto Sequencer

P216 Series Condenser Fan Speed Controller

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating Instructions

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

Model 2380 Rack-Mount Kit

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Scanner 2000 Steam Mass Flow Transmitter

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

ECL Comfort V a.c. and 24 V a.c.

C9900-P223 and C9900-P224

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

4-step Chiller and Heat Pump Controller

Overview - Danfoss Link and Connect software versions

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

ALO Duo Roll DMX LED barrel scanner with dual light source

Intercom Installation The b-red. KIT audio entry control systems AKW200/201

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

Converter SINAMICS G150. Type 6SL37102G

Pre-installation Manual

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

11.2 Universal Ceiling Mount Monitor M MENU POWER E EXIT OWNER S MANUAL

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

INSTALLATION MANUAL SLI 50 INVERTER

Transcription:

MAKING MODERN LIVING POSSIBLE Installation Guide 086L70 www.heating.danfoss.com

Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 006/4/EC) Copyright Danfoss A/S

Table of Contents General... 4. Safety precautions... 4. Introduction... 4. Installation overview... 5.4 Positioning of components... 6 Preparations... 9. Installation of heat pump with control unit and outdoor unit (Master)... 9. Installation of additional outdoor unit (Slave)... 9. Installation of Expansion card and terminal block with cable harness... 0 Installation of Twin kit... 4 Start up... 5 Appendix System solution... 5 Danfoss Heating Solutions VMBQS0

General These instructions describe the installation. A unit means that an existing heat pump (Master), consisting of an external unit and an internal unit, can have an external unit (Slave) added. The installation includes the pipes and electrical installation, plus necessary settings in the control system. References to menu options in the control unit are in upper case, e.g. INFORMATION ->OPERAT. -> AUTO. References to other documents and figures are marked in italics, e.g. Installation Guide.. Safety precautions Danger Hazardous electrical voltage! The connectors are live and can be highly dangerous due to the risk of electric shock. All power supplies must be isolated before electrical installation is started. Warning Risk of personal injury! Children are not permitted to play with the product. Warning Electrical installation may only be carried out by an authorised electrician and must follow applicable local and national regulations. Warning The electrical installation must be carried out using permanently routed cables. It must be possible to isolate the power supply using a multi-pole circuit breaker with a minimum contact gap of mm. Caution This product is not intended for persons (including children) with reduced physical, sensory or psychological capacity, or who do not have knowledge or experience, unless supervised or they have received instructions on how the apparatus functions from a safety qualified person. Caution Scrapping must be carried out in accordance with applicable local rules and regulations.. Introduction When a is used in a heating system, two outdoor units (Master and Slave) are communicating with each other and sharing the same control unit (installed indoors). The software in the control unit is prepared for master/slave operation and is automatically activated during the commissioning and start up procedure. The power supply is connected individually to each outdoor unit. 4 VMBQS0 Danfoss Heating Solutions

. Installation overview An overview of the installation is shown in the figure below: 4 Pos. Description Heat pump Danfoss DHP-AQ Mini, DHP-AQ Midi Heat pump Danfoss DHP-AQ Maxi Outdoor unit (Master) 4 Outdoor unit (Slave) Danfoss Heating Solutions VMBQS0 5

.4 Positioning of components.4. Components in control unit The positions of the components in the control unit are shown in the figure below: 5 Fig. : Components in control unit 4 Pos. Description Expansion card HUB card Expansion block 4 X terminal block 5 Cover for cable duct 6 VMBQS0 Danfoss Heating Solutions

.4. Components in electrical cabinet The positions of the components in the electrical cabinet are shown in the figure below: 4 Fig. : Components in the electrical cabinet Pos. Description HP card EEV card Power terminal block 4 X Terminal block Danfoss Heating Solutions VMBQS0 7

Installation Guide.4. Delivery check The Twin kit accessory is shown in the figure below: 6 7 8 9 0 5 4 Accessories for the installation are supplied in an enclosed cardboard box. Check that the contents correspond to the following table: Pos. 4 5 6 7 8 9 0 8 Part No. 086U940 086L0766 086U9977 086U847 086U0086 086U9709 086U970 086U67 086L098 086L4 Quantity 4 Description Expansion card Cable harness, expansion card Block, expansion card RJ-45 communication cable,,000 mm Circuit board support Supply line sensor 0 Return line sensor System supply line sensor Installation instructions for expansion card and terminal block These installation instructions Rivets VMBQS0 Danfoss Heating Solutions

Preparations Before starting the Twin-Kit installation, the following steps must be taken:. Installation of control unit (, or ) and outdoor unit (Master) ().. Installation of additional outdoor unit (Slave) (4).. Installation of expansion card and terminal block, with cable harness. 4 Fig. : Twin-Kit installation with control unit and outdoor units. Installation of heat pump with control unit and outdoor unit (Master) Carry out the normal installation as outlined in the heat pump Installation guide.. Installation of additional outdoor unit (Slave) Position the additional outdoor unit in accordance with the Transport, unpacking and positioning chapter in the Installation guide. Connect the supply and return lines in accordance with System solutions appendix. Danfoss Heating Solutions VMBQS0 9

. Installation of Expansion card and terminal block with cable harness Install the expansion card and terminal block with cable harness in accordance with the attached Installation of expansion card and terminal block instructions. See position,, and. 0 VMBQS0 Danfoss Heating Solutions

Installation of Twin kit The installation consists of the following procedures:. Electrical Installation. Commissioning. Settings in the control system. Electrical Installation Electrical installation is carried out in accordance with the following activities:. Control unit. Outdoor unit s electrical cabinet (Slave). RJ-45 communication cable 4. Communication cable between control unit and outdoor units (Master and Slave) Control unit See Figure on page 6 for the location of the components in the control unit. Danfoss Heating Solutions VMBQS0

Electrical connections in control unit Circulation pump N Only applicable for control units with in-built circulation pump. That is for the Danfoss DHP-AQ Midi and DHP-AQ Maxi heat pump models.. Disconnect the circulation pump from the terminal block by loosening the contacts from the connections marked 0., N and PE. See position.. Peel off the cable sheath about 0 mm. See position.. Reconnect the circulation pump by connecting the wires as follows: Wires which were connected to the X terminal block, marked 0., are connected to the expansion board, marked 0.. See position. Wires which were connected to the X terminal block, marked N, are connected to the X terminal block, marked N, (same connection as before). See position. Wires which were connected to the X terminal block, marked PE, are connected to the expansion board, marked PE. See position. VMBQS0 Danfoss Heating Solutions

0-0V and alarm N Only applicable for control units with in-built circulation pump. That is for the Danfoss DHP-AQ Midi and DHP-AQ Maxi heat pumps models.. Disconnect the 0-0 V and alarm from the terminal block by loosening the wires from the connections marked 6., 6. and COM. See position.. Reconnect the 0-0 V and alarm to the expansion board by connecting the wires as follows: Wires which were connected to the X terminal block, marked 6., are connected to the expansion board, marked 06.. See position. Wires which were connected to the X terminal block, marked 6., are connected to the expansion board, marked 06.. See position. Wires which were connected to the X terminal block, marked COM, are connected to the expansion board, marked COM. See position. Danfoss Heating Solutions VMBQS0

Installation Guide Slave sensor N Not applicable for the Danfoss DHP-AQ Mini heat pump... Disconnect the supply line sensor s Molex contact on the HUB card from the connection marked 0. See position. For Danfoss DHP-AQ Maxi heat pump, the Molex contact which is connected to the connection, marked, must be disconnected. See position.. Loosen the cables by cutting away the cable tie so that the cables can be pulled back. Then run them to the lower corner of the assembly plate under the expansion board. See position. 4. Cut off the connector house and peel off the wire insulation. See position. 4 VMBQS0 Danfoss Heating Solutions

Installation Guide 5. Connect the supply line sensor wire to the expansion card connections as follows: Connect the red wire to the expansion board connection marked 08.4. See position. Connect the white wire to the expansion board connection marked COM. See position. 6. For the Danfoss DHP-AQ Maxi heat pump, the return line sensor wire must be connected to the expansion board connections marked 08.5 and COM. Master sensor N Not applicable for the Danfoss DHP-AQ Mini heat pump.. Remove the cover on the cable duct located above the HUB card. See position 5.. Take out the supply line cable (with the mounted Molex connector marked 0, and 0,) from the cable duct. See position. For the Danfoss DHP-AQ Maxi heat pumps, take out the return line cable (with mounted Molex connector marked, and,) from the cable duct. 5 4. Danfoss Heating Solutions VMBQS0 5

Installation Guide 4. 5. 6. 4 7. Connect the supplied supply line sensor as follows: Connect the red wire to the X terminal block connection marked 0. See position 4. Connect the white wire to the X terminal block X marked COM. See position. 8. Connect the supplied return line sensor as follows: Connect the red wire to the X terminal block connection marked. Connect the white wire to the X terminal block connection marked COM. 9. Pick up the enclosed system supply line sensor from the. Connect the supplied system supply line sensor as follows: Connect the red wire to the X terminal block connection marked 8.. Connect the white wire to the X terminal block connection marked COM. 0. 6 Connect the supply line cables (with mounted Molex connectors) to the HUB card connection marked 0. See position. For the Danfoss DHP-AQ Maxi heat pumps, the return line cables (with the mounted Molex connectors) must be connected to the HUB card connection marked. See position. Pick up the enclosed supply line sensor (marked 0) and the return line sensor (marked ) from the Twin Kit. VMBQS0 Danfoss Heating Solutions

Electrical cabinet for the outdoor unit (Slave) See figure on page 7 for the unit s position in the outdoor unit s electrical cabinet.. Remove the jumper from the EEV card. See position.. Move the dipswitch on the HP card from position to position. See position. Danfoss Heating Solutions VMBQS0 7

RJ-45 communication cable See Figure on page 6 for the positions in the control unit.. Connect the supplied RJ-45 communication cable to the expansion card output marked 09. See position.. Connect the other end of the RJ-45 communication cable to the HUB card s output marked. See position.. Communication cable between control unit and outdoor units N The communication cable is not supplied. The communication cable is connected as follows:. Between the control unit and outdoor unit (Master). Between the outdoor units (Master and Slave) Communication cable between control unit and outdoor unit (Master) See figure on page 6 for the positioning in the control unit. See figure on page7 for the positioning in the outdoor unit s electrical cabinet. 8 VMBQS0 Danfoss Heating Solutions

. Connect the communication cable to the terminal block (control unit) as follows: Connect a wire to the X terminal block connection marked BUS_A. See position. Connect a conductor to the X terminal block connection marked BUS_B. See position. Connect a conductor to the X terminal block connection marked COM. See position.. Connect the other end of the communication cable to the X block (outdoor unit s electrical cabinet) as follows: Connect a wire to the X block connection marked BUS_A. See position. Connect a wire to the X block connection marked BUS_B. See position. Connect a conductor to the X block connection marked COM. See position. Danfoss Heating Solutions VMBQS0 9

Communication cable between outdoor units, Master and Slave See figure on page 7 for the positioning in the outdoor unit s electrical cabinet.. Connect the communication cable to the X block (Master) as follows: Connect a wire to the X block (Master electrical cabinet) connection marked.5. See position. Connect a wire to the X block (Master electrical cabinet) connection marked.6. See position. Connect a conductor to the X block (Master electrical cabinet) connection marked COM. See position.. Connect the other end of the communication cable to the block X (Slave) as follows: Connect a wire to the X block (Slave electrical cabinet) connection marked.5. See position. Connect a wire to the X block (Slave electrical cabinet) connection marked.6. See position. Connect a wire to the X block (Slave electrical cabinet) connection marked COM. See position.. Commissioning Connect the external supply voltage..4 Settings in the control system The following symbols are used to control the menu selection in the control unit: Symbol Description + Arrow button + on control unit - Arrow button -" on control unit -> Right arrow button on control unit <- Left arrow button on control unit 0 VMBQS0 Danfoss Heating Solutions

Input the following settings on the control unit: Start-up, Settings for Master Start-up, Settings for Slave Basic settings for heat pump units 4 Settings for selection, Optimum 5 Settings for hot water 6 Settings for cooling 7 Settings for electric auxiliary heater 8 Check, Manual test 9 Operation Danfoss Heating Solutions VMBQS0

4 Start up 4. Settings for Master. Press and hold < for 5-0 seconds.» The SERVICE menu is shown.. Press to scroll down to INSTALLATION.. Press > to select INSTALLATION. 4. Press > to select SYSTEM. 5. Press to scroll down to MASTER/SLAV. 6. Press > to select MASTER/SLAV. The selection is selected. Then press + to activate.» Result: MASTER/SLAV = ON. 7. Press < to deselect the option. If an adjustable Class A circulation pump is to be used for the master unit, go to Step 8. Otherwise, continue to Step 0. 8. Press + to scroll up to OPTIMUM. Press > to select OPTI- MUM. The selection is selected. Then press + to activate.» Result: OPTIMUM = ON. 9. Press < to deselect the option. Continue to Step 0. 0. Press + to scroll up to HEAT SOURCE. Press > to select HEAT SOURCE.. Press > to select AIR.» DIRECT EVAP. is shown.. Press and hold > for approx 0 seconds.» HEAT PUMP OUTPUT is shown.. Press to select size. Press > when the correct size is selected.» An asterisk (*) is shown next to the selected heat pump output. 4. Press < repeatedly.» The start screen is shown. 4. Settings for Slave. Press and hold > for 5-0 seconds.» The SERVICE menu is shown.. Press to scroll down to INSTALLATION.. Press > to select INSTALLATION. 4. Press > to select SYSTEM. If an adjustable Class A circulation pump is to be used for the slave unit, go to Step 5. Otherwise, continue to Step 7. 5. Press to scroll down to OPTIMUM. Press > to select OPTI- MUM. The selection is selected. Then press + to activate.» Result: OPTIMUM = ON. 6. Press < to deselect the option. Press + to scroll up to HEAT SOURCE. Continue to Step 7. 7. Press > to select HEAT SOURCE. 8. Press > to select AIR.» DIRECT EVAP. is shown. 9. Press and hold > for approx 0 seconds.» HEAT PUMP OUTPUT is shown. 0. Press to select size. Press > when the correct size is selected.» An asterisk (*) is shown next to the selected heat pump output.. Press < repeatedly.» The start screen is shown. 4. Basic settings for heat pump units. Press and hold < for 5-0 seconds.» The SERVICE menu is shown.. Press to scroll down to INSTALLATION.. Press > to select INSTALLATION. 4. Press to scroll down to FACTORY SET. Press > to select FACTORY SET. 5. Press to scroll down to RADIATOR or FLOOR. Press > to select RADIATOR or FLOOR.» An asterisk (*) is shown next to the selected option. 6. Press < to exit FACTORY SET. Wait approx 0 seconds.» The settings is activated. 7. Press < repeatedly.» The start screen is shown. VMBQS0 Danfoss Heating Solutions

4.4 Settings for options Optimum. For Master: Press and hold < for 5-0 seconds. Continue to Step.» The SERVICE menu is shown.. For Slave: Press and hold > for 5-0 seconds. Continue to Step.» The SERVICE menu is shown.. Press to scroll down to OPTIMUM. Press > to select OPTI- MUM.» See the heat pump Installation instructions for the parameter meanings. 4. Press < repeatedly.» The start screen is shown. Settings for hot water. Press and hold < for 5-0 seconds.» The SERVICE menu is shown.. Press > to select HOT WATER.. Press > to select START. 4. Press + to set the desired start temperature for hot water.» The recommended start temperature is 40 C. 5. Press < repeatedly.» The start screen is shown. 6. Press <.» The INFORMATION menu is shown. 7. Press to scroll down to HOT WATER. 8. Press > to select HOT WATER. Then press > again to select HOT WATER. Then press + to activate HOT WATER.» Result: HOT WATER = ON. 9. Press < repeatedly.» The start screen is shown. Settings for cooling. For Master: Press and hold < for 5-0 seconds.» The SERVICE menu is shown.. For Slave: Press and hold > for 5-0 seconds.» The SERVICE menu is shown.. Press to scroll down to COOLING. Press > to select COOL- ING. 4. Press > to select COOLING. Press > again.» The settings menu opens. 5. Press to go to AKTIV COOLING. Press > to select AKTIV COOLING. 6. Press > to select INTEGRATED IN HP.» An asterisk (*) is shown. 7. Press < repeatedly.» Until the start screen is shown. 8. Press <.» The INFORMATION menu is shown. 9. Press to scroll down to COOLING. 0. Press > to select COOLING. Press > again to select the option COOLING. Press + to activate COOLING.» Result: COOLING = ON.. Press < repeatedly.» The start screen is shown. Settings for electrical auxiliary heater. Press and hold < for 5-0 seconds.» The SERVICE menu is shown.. Press to scroll down to AUX. HEATER. Press > to select AUX. HEATER.. Press > to select MAX STEP. Press + to set the desired stepped setting for the electric auxiliary heater. Press < to deselect. If an external auxiliary heater is to be configured, go to Step 4. Otherwise continue to Step 6.» 4. Press to scroll down to EXTERN AUX. HEATER 5. Press > to select EXTERN AUX. HEATER. Press > again to select the option. Press + to activate the option.» Result: EXT. AUX. HEATER = ON. 6. Press < repeatedly.» The start screen is shown. Danfoss Heating Solutions VMBQS0

4.5 Check Manual test. For Master: Press and hold < for 5-0 seconds. Go to Step.» The SERVICE menu is shown.. For Slave: Press and hold > for approx 5-0 seconds. Go to Step.» The SERVICE menu is shown.. Press to scroll down to MANUAL TEST. Press > to select MANUAL TEST. 4. Press > to select MANUAL TEST. 5. Press + to set the system to MANUAL TEST.» Result: MANUAL TEST =. 6. Test the various components: Scroll up and down using and +. Select and deselect using > and <. Activate and deactivate components to be tested by pressing + or respectively, when an option is selected. 7. Press + to scroll up to MANUAL TEST. End manual testing by pressing > to select MANUAL TEST. Press to end MANUAL TEST.» Result: MANUAL TEST = 0. 8. Press < repeatedly.» The start screen is shown. 4.6 Operation. Press <.» The INFORMATION menu is shown.. Press > to select OPERAT.. Press to scroll down to AUTO. 4. Press > to select AUTO.» An asterisk (*) is shown next to the selected option. 5. Press < repeatedly.» Until the start screen is shown. The outdoor units are now in operation. 4 VMBQS0 Danfoss Heating Solutions

5 Appendix System solution 7 6 49 0 0 07 08 09 0 0 79 8 80 8 80 8 80 0 0 60 0 5 50 6 40 04 77 5 85 55 87 8 80 6 6 A 5 00 00 8 4 5 96 9 5 B 5 9 5 96 Pos. Description A Master B Slave 5 Heat pump unit 0 Supply line Return line Cold water Hot water 8 Hot water tank 0 Circulation pump 6 Circ.pump (system) 40 Control unit 49 Supply line sensor system 50 Outdoor sensor 5 Supply line sensor (hp) 5 Return line sensor 5 Hot water sensor start (hp) 55 Hot water sensor top (hp) 60 Sensor pool 6 Room sensor 6 Shunt valve (nd shunt) 77 Reversing valve 79 Reversing valve cooling 80 Shut-off valve 8 Non-return valve 85 Venting valve 87 Safety valve (9 bar) 9 Strainer filter ball 96 Flexible hose 00 Safety valve (,0 bar) 0 Reversing valve pool 0 Heat exchanger pool 04 Expansion card 07 Shunt valve (shuntgrp ) 08 Supply line sensor (shuntgrp ) 09 Circ.pump (shuntgrp ) Expansion tank 4 Additional heater 7 Additional heater 0 Cooling unit (-s) Danfoss Heating Solutions VMBQS0 5

6 VMBQS0 Danfoss Heating Solutions

Danfoss Heating Solutions VMBQS0 7

Danfoss Heat Pumps Box 950 67 9 ARVIKA Phone +46 570 800 E-mail: dhpinfo@danfoss.com Internet: www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. VMBQS0 Produced by Danfoss Heating Solutions 0