Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

Similar documents
TOS-SN-1 Extended Panel Operation Manual

Optional add-on cassette Attachment Instruction manual

Installation, Operation and Maintenance Manual

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE

Communication & Networking

ASD-Multicom-X Expansion TB option unit Instruction manuall

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

TOSVERT VF-S11 built-in board option

Product Discontinuation Notices. Discontinuation Notice of Multi-function Compact Inverter 3G3MX Series

PIEZO FEEDER CONTROLLER

Easy To Use OEMS Take Note

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

INSTALLATION INSTRUCTIONS

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

ELV12 Series. Instruction Manual

Remote Keypad Instruction Manual RKP002Z

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Communications & Networking

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Inverter (VFD) Manual

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Mini Photoelectric Sensor

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

Compact Inductive Proximity Sensor

Table of Contents Product Overview Before using the product Installation Procedure... 5

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

SB200. VSV V/F Control Inverter. High-performance. Applications General pump & fan control HVAC Industrial motor control

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

InView Marquee Message Display

Suitable for detecting transparent films or transparent bottles

Installation Instructions

Voltage Current Front-mounting bracket

Siemens Industrial s

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Instruction Bulletin A August, 1995 Replaces dated 4/93 Price: $10.00

Model 2380 Rack-Mount Kit

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

EQ5 SERIES Quick Start Guide for Constant Torque Applications

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

S8VE (60/90/120/180/240-W Models)

Power Supply and Fan Module Installation

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Cylindrical Proximity Sensor

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Frequency Inverters WJ200 Series Compact Inverter

INSTALLATION MANUAL For authorized service personnel only.

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

VS mini J7 to J1000 Replacement Instructions

Thread length (overall length) material

E4PA. Ultrasonic Displacement Sensor. Ordering Information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Vane Type Photoelectric Switches with Self-contained Amplifier

Actuator Terminal Model

PowerLogic High Density Metering System 1-Meter Enclosure

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Manual FC 3500 DC Fan Control

Important Safety Notice

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

For additional PowerFlex 4M data and general drive information, refer to the following publications:

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction.

Chemical Resistant Inductive Prox

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

THE CTB08D LIGHT CONTOLLER

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

CDD Carbon Dioxide Transmitter

Switching Power Supply

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Inductive Proximity Sensor

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

MicroTech II TM Remote I/O Panel Installation Manual

The following conventions are used to indicate precautions in this manual.

Altivar 31C. Installation manual. Wall-fixing variable speed drives for asynchronous motors

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Transcription:

2 Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter TOSVERT VF-S11 Thank you for purchasing a Toshiba Totally-enclosed box type TOSVERT VF-S11 series inverter. This Manual gives a supplementary explanation of some items referred to in the instruction manual E6581158 included with the product. Please read this manual carefully along with the instruction manual E6581158. 1-phase 240V class 3-phase 240V class 3-phase 500V class 0.2 to 2.2kW 0.4 to 4.0kW 0.75 to 4.0kW - To set makers - Please see to it that this manual is supplied to the inverter s end user, along with the instruction manual E6581158.

Safety precautions Before reading this manual, please read the following instructions in addition to I. Safety Precautions, of the instruction manual E6581158. General Operation Danger Mandatory Circuit boards are exposed when the front cover is removed. So do not detach the front cover when the inverter is energized or within 10 minutes after power is turned off. Doing so could result in electric shock. Transportation Warning Mandatory When handling the inverter unit, hold it by both the sides firmly. If you hold it by the fins at the upper and lower parts, you could get injured. 1

Exterior Features (5) (4) (3) (1) TOSHIBA 0.0 Mode key (2) MODE CHARGE lamp ENT Enter key (6) Indicates that high voltage is still present within the inverter. Do not open the cover while this is lit. Down key Up key Side view (7) No. Devices Remarks (1) Operation panel Equipped with,, MODE and ENT keys used to set parameters, a 7-segment LED and a CHARGE lamp.(the inverter does not have a RUN key, a STOP key and a potentiometer control, which are provided for VF-S11 standard series inverters.) (2) Manual power ON-OFF switch Used to turn on and off power manually. Note 1: (3) Slots (x 2) reserved for optional devices Slots for optional contact input switches. Note 2: (4) Operation ON-OFF rotary switch Used to start and stop the inverter. (5) Potentiometer for frequency setting Used to set the operation frequency of the inverter. (6) Wiring port plate Steel plate with wiring portsthe effects of noise can be reduced to some degree by fixing shielded parts of cables with cable grounds or similar devices. See page 7. (7) Name plate Label on which the ratings of the inverter unit is printed. Note 1: The switch has the function of tripping (overcurrent tripping). If the switch is in the Trip position, inspect the inverter before turning back on the power switch, because the inverter itself may be faulty. Note 2: Recommended contact input switches: Harmony series (XB5 series) 2

Main circuit and control circuit terminal boards To front cover Control signal cable connector Internal cooling fan Control circuit terminal board Main circuit terminal board 1 Power supply : R/L1, S/L2, T/L3 (Single-phase : R/L1, S/L2) Main circuit terminal board 2 Motor output : U/T1, V/T2, W/T3, Internal DC section : P0, PA/+, PB, PC/- How to remove the front cover 1. Shut off the supply of electricity from the main power supply, and turn the manual power ON-OFF switch to the OFF position. 2. Ten minutes or more after turning off power, check to be sure that the CHARGE lamp is not lit. 3. Remove the 6 screws* (indicated by the arrows in the figure) around the front cover. (* 4 screws for single/three-phase 240V-0.75kW models and smaller) 4. Pull the front cover slowly toward you to remove it and detach the control signal cable connector. How to attach the front cover 1. Attach the control signal cable connector. 2. Attach the front cover. 3. Set and tighten the 6 screws* (indicated by the arrows in the figure) around the front cover. (* 4 screws for single/three-phase 240V-0.75kW models and smaller) Caution: Attach the front cover securely. Or else it does not serve as a protector compliant with IP54. On top of that, it may become impossible to operate the keys on the operation panel. About the built-in cooling fan The inverter has a built-in cooling fan. The cooling fan has a useful life of approximately 30,000 hours (2 to 3 years when operated continuously), so it needs to be replaced periodically. (Single/three-phase 240V-0.75kW models and smaller are not equipped with cooling fans.) If the cooling fan does not operate normally, the temperatures of the internal electrical components will rise high, and as a result their lives will be shortened. So inspect it periodically. About the useful life of the manual power ON-OFF switch The manual power ON-OFF switch has a useful life of approximately 5 years (if operated 12 hours per day at an average yearly ambient temperature of 30 C), so it needs to be replaced periodically. 3

Wiring diagram (7) (1) Input power cable (2) Output cable (3) Control cable (4) Control resistor (optional) cable (5) Wiring port plate (6) Grounding terminal (7) Optional communications device interconnect cable (Option) (6) (6) (5) (1) (4) (3) (2) Cautions Circuit boards are exposed when the front cover is removed. Since high voltages are applied to some parts of the circuit board, read Section 2.1, Cautions on wiring, of the instruction manual E6581158 carefully before wiring. When connecting cables, take care not to damage the circuit board with a screwdriver or a similar tool. To connect the power cable (to the manual power ON-OFF switch), torque the terminal screw to 1.7N m (recommended). (M4 screw) Never turn on the power ON-OFF switch before attaching the front cover. Or you could get a shock. The main circuit terminal board (input power cable) has terminals of a cable pinch type. Before connecting a cable, strip off its sheath to a length of 10mm or so. Torque: 1.7N m Approx. 10mm 4

Diagram of cables connected at the factory < WN type : Sink logic > < WP type : Source logic > P24 PP VIB CC PP VIB CC Red White Black F CC Red White Black F CC Potentiometer for frequency setting Blue Blue Potentiometer for frequency setting Blue 0 Fw Blue 0 Fw Operation ON-OFF rotary switch Operation ON-OFF rotary switch Note: The colors indicated in the above figure refer to the colors of cables. Installation environment 10cm or more VFS11 5cm or more 5cm or more 10cm or more Operate in areas where ambient temperature ranges from -10 C to +40 C. Install the inverter in a well-ventilated place and mount it on a flat metal plate in portrait orientation. Install the inverter so that it is not inclined more than ±10 from the vertical. Leave a space of 10cm or more on the upper and lower sides of the inverter, and a space of 5cm or more on each side. The inverter has a built-in cooling fan. The cooling fan has a useful life of approximately 30,000 hours (2 to 3 years when operated continuously), so it needs to be replaced periodically. The inverter has a built-in cooling fan. (Single/three-phase 240V-0.75kW models and smaller are not equipped with cooling fans.) If the cooling fan does not operate normally, the temperatures of the internal electrical components will rise high, and as a result their lives will be shortened. So inspect it periodically. 5

Outside dimensions Voltage class 1-phase 240V 3-phase 240V 3-phase 500V Applicable Outside dimensions (mm) Motor Inverter type (kw) W H D W1 H1 D1 0.2 VFS11S-2002PLE 0.4 VFS11S-2004PLE 210 240 177 192 218 14 0.75 VFS11S-2007PLE 1.5 VFS11S-2015PLE 215 297 206 197 277 14 2.2 VFS11S-2022PLE 230 340 222 212 320 14 0.4 VFS11-2004PME 0.75 VFS11-2007PME 210 240 177 192 218 14 1.5 VFS11-2015PME 2.2 VFS11-2022PME 215 297 206 197 277 14 4.0 VFS11-2037PME 230 340 222 212 320 14 0.75 VFS11-4007PLE 1.5 VFS11-4015PLE 215 297 206 197 277 14 2.2 VFS11-4022PLE 4.0 VFS11-4037PLE 230 340 222 212 320 14 Cable port φ19 3 φ21 1 φ19 1 φ23 3 φ19 3 φ21 1 φ19 1 φ23 3 φ19 1 φ23 3 H1 (Installation dimension) H 2-R2.75 W1 (Installation dimension) W 9 D 14 6

Model Rating Power supply E6581225 Specifications Item Specification Voltage class 1-phase 240V class/3-phase 240V class/3-phase 500V class Applicable motor (kw) 0.2 0.4 0.75 1.5 2.2 4.0 Voltage class Model number VFS11S-/VFS11-1-phase 240V class VFS11S- 2002PLE 2004PLE 2007PLE 2015PLE 2022PLE - 3-phase 240V class VFS11- - 2004PME 2007PME 2015PME 2022PME 2037PME 3-phase 500V class VFS11- - - 4007PLE 4015PLE 4022PLE 4037PLE Capacity (kva) Note 1: 0.6 1.3 1.8 3.0 /3.0 /3.1 4.2 6.7 /7.2 1-phase 240V 1.5 (1.5) 3.3 (3.3) 4.8 (4.4) 8.0 (7.9) 11.0 (10.0) - Output current (A) 3-phase 240V - 3.3 (3.3) 4.8 (4.4) 8.0 (7.9) 11.0 (10.0) 17.5 (16.4) Note 2: 3-phase 500V - - 2.3 (2.1) 4.1 (3.7) 5.5 (5.0) 9.5 (8.6) Output voltage Note 3: 240V class: 3-phase 200 to 240V, 500V class: 3-phase 380 to 500V Overload current rating 150%-1min., 200%-0.5 sec. (50%-reduction value) Voltage-frequency 240V class: 1-phase/3-phase 200 to 240V-50/60Hz, 500V class: 3-phase 380 to 500V-50/60Hz Allowable fluctuation Voltage+10%, -15% Note 4:, Frequency±5% Protective method Totally enclosed type (JEM1030) compliant with IP54/possible to bring into compliance with IP55 Note 5: Environments Cooling method Color Built-in filter Self-cooled (with a built-in cooling fan. 1-phase/3-phase 240V-0.75kW or smaller: Cooling fan not provided) Munsel 5Y-8/0.5 1-phase & 500V class: High-attenuation EMI filter, 3-phase 240V class: Standard filter Indoor type. Altitude: Not more than 1000m. Use environments Place free from corrosive and explosive gases Ambient temperature -10 to +40 Storage temperature -25 to +70 Relative humidity 20 to 93% Vibration 5.9m/s or less (10 to 55Hz) Note 1: Capacity is calculated at 220V for the 240V models and at 440V for the 500V models. Note 2: Indicates rated output current setting when the PWM carrier frequency (parameter F300) is 4kHz or less. The values between parentheses refer to output currents at PWM carrier frequencies of over 4kHz. They need to be reduced further at frequencies over 12kHz (If a motor cable over 30m in length is used, it is necessary to reduce them more. This means that the lives of the internal components will be shortened). When the input power voltage of the 500V class model exceeds 480V, it is necessary to further reduce the setting. The default setting of the PWM carrier frequency is 12kHz. Note 3: The maximum output voltage is equal to the input supply voltage. Note 4: ±10% when the inverter is operated continuously (under a load of 100%). Note 5: IP54-compliant structures refer to structures that protect the contents from dust and harmful effects of water that drops from every direction. The inverter can be brought into compliance with IP55 specifications by making the wiring port watertight. (IP55-compliant structures refer to structures that protect the contents from dust and harmful effects of water that comes in a jet from every direction.) To bring the inverter into compliance with IP-55, use PG screw type cable grounds. Among cable grounds available are skin-top grounds manufactured by LAPP (Germany). When using this type of grounds, use them in combination with lock nuts specified below. Cable port Cable ground Cable ground(emc-compliant) Lock nut φ19 hole MS11 MS-SC11 SM-11 φ21 hole MS13.5 MS-SC13.5 SM-13.5 φ23 hole MS16 MS-SC16 SM16 Note 6: For control specifications, parameters and functions, refer to the instruction manual E6581158. Note 7: The factory default settings of the following parameters are different from those of the VFS-11 standard type. Title Function Standard VF-S11 Totally enclosed type VF-S11 cmod Command mode selection 1 0 fmod Frequency setting mode selection 0 2 Note 8: The inverter has a built-in cooling fan. The cooling fan has a useful life of approximately 30,000 hours (2 to 3 years when operated continuously), so it needs to be replaced periodically. (Single/three-phase 240V-0.75kW models and smaller are not equipped with cooling fans.) If the cooling fan does not operate normally, the temperatures of the internal electrical components will rise high, and as a result their lives will be shortened. So inspect it periodically. Note 9: The manual power ON-OFF switch has a useful life of approximately 5 years (if operated 12 hours per day at an average yearly ambient temperature of 30 C), so it needs to be replaced periodically. 2 7