NIR Moisture Analyzer KB-30

Similar documents
Wireless LAN Connecting Adapter [BRP072B42] Installation Manual

NIR Moisture Analyzer KB-230

FOR VISUAL CARD READER / WRITER. Installation Guide & Specifications

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

User Manual VIDEO DOOR PHONE

Users Manual STP-103II. Thermal Printer Rev

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

Optional add-on cassette Attachment Instruction manual

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

4P Wireless LAN Connecting Adapter <BRP069B41> <BRP069B42> <BRP069B43> <BRP069B44> <BRP069B45> Installation Manual

Digital Overhead Stirrer

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

User Manual DUO BEAM/RG

TOS-SN-1 Extended Panel Operation Manual

Motorized Curtain Tracks Progress 50 Motor Set

DOT MATRIX PRINTER SP6000 SERIES

A120 A W/240W PA Mixer-Amplifier 70V/100V

ELV12 Series. Instruction Manual

4P S. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual

Home Network. .in.ua. User Manual. Video Door Phone CDV-40N.

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

Infrared Moisture Determination Balance FD-610. Operating Manual

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

1 Channel Strobe Controller ORDERCODE 40226

4P S. Wireless LAN Connecting Adapter <BRP069A42> Installation Manual

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Promopar ORDERCODE 30120

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

4P R. Wireless LAN Connecting Adapter <BRP069A81> Installation Manual

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

UV Power Flood. User Manual. Order code: EQLED029

Large Police Light 100W ORDERCODE 80361

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

ITA100 MKII 100mW green DMX laser

S8VE (60/90/120/180/240-W Models)

Konica Minolta s industrial instruments. Safety Precautions

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual

ALO Duo Roll DMX LED barrel scanner with dual light source

Colour Star Sky I DMX ORDERCODE 40341

FT-20 Fire Training Fog Machine User Manual English

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

FT-20 Fire Training Fog Machine User Manual English

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

E2Q4 Square Proximity Sensor

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

SERVICE MANUAL Yhu#614 pzz lgkh{laz UG\SGYWX]

V 1.0 ISSUE DATE : Feb.17, 2011

POWER SUPPLY UNIT PSU-3

Gobo Projector XP 80W

Crossfire. User Manual. Order code: EQLED061

To Purchase This Game, Visit BMI Gaming Or Contact International Sales at (USA)

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

EZ864 UMTS Terminal Telit Cellular GSM Engine

EC Series. Safety Guide

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

LED Par 64 Short DMX ORDERCODE 42431

Thread length (overall length) material

PCT2000. User Manual. Precision current transducer 2000 A

Incubator Shaker with Cooling

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Package Contents. GP Options (Made by Digital)

User Manual. GUARD STATION(Gate View System) CDS-4GS

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

DF-780(B) Operation Guide

For Sales + Purchasing Info, Click Page To Visit BMI Gaming (800)

Model VC-SHIELD Shield Box

CS2 DMX Distribution Splitter

PF LED Profile. User Manual

PRECAUTIONS FOR USE. Be sure to use indoor wiring within the specified voltage requirements. For extension cord, use the specified rating or more.

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM E FR20/30 SERIES DSU-FR20/30 EMULATOR MB HARDWARE MANUAL

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Instruction Manual MINI CALIBRATOR MC-20

FengMi Wemax One Laser Projection TV

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

DS-1H05 Ethernet-over-Coax Extender. User Manual

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

ZF LED Zoom Fresnel. User Manual

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Blitzer Strobe. User Manual. Order code: EQLED366

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

MT8050iE series. Installation Instruction (1) (2)

USB Data Transfer Cable CA3-USBCB-01 Installation Guide

PV Module Installation Instructions

F1000 User's Manual. (Version: V1.01)

Universal AC Power Source + AC Power Analyzer

RZ2 BioAmp Processor. Operator s Manual

Transcription:

NIR Moisture Analyzer KB-30 Operation Manual

Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property due to fire, smoke and other problems. Furthermore, the infrared moisture tester has high temperature components which can cause burns if proper safety guidelines are not followed. Please observe the safety precautions. Please read the precautions noted in the operating manual. Do not use if broken. If you suspect a problem or malfunction in the unit, discontinue use and please contact to your dealer. Warning symbol explanation. In order to prevent damage resulting from erroneously operating the equipment, the following symbols are indicated in the operating manual and on the product. Please review the descriptions. Warning Failure to observe these items may lead to death or injury to the user. Caution Failure to observe these items may lead to injury to the user or damage to property. Note Items which the user should be aware of in order to safely use the unit. Warning Please do not use the product in the location where there is gas or liquid that have explosive or flammable. It may cause explosion, fire, or electric shock. This product should be used only with the applicable power supply voltage. Using this product with incorrect voltage may cause the product to be overheated, which may result in trouble or fire. Make sure to connect the ground of power cable to the protective earth. If do not have grounding, there is a risk of electric shock or fire. Please do not use if the power cable was damaged (such as disconnection). It may cause electric shock or fire. If you see fire coming from the unit or notice smoke, an odd smell, or any other sign of abnormal functioning, remove the power plug from its socket, and take whatever other steps would be appropriate to deal with the problem. Do not attempt to disassemble, modify or rebuild the NIR moisture analyzer. Doing so may result in an accident, electric shock, or other problems. If you have found any abnormality in the unit, please consult your dealer. Caution Please do not place heavy objects on the power cable. Please do not heating or hurting the power cable. It may cause electric shock or fire. If connect other devices, please power off both units at first. Please do not touch the power cable by wet hands. It may cause electric shock. When installing, detaching or maintenance the unit, please take off the power cable at first for your safety. Please do not pull out the power cable grabbing the cable part. Please do not look directly into the light source. It may an adverse effect on eyes.

Contents 1. Features... 4 1-1. Measurement Principle... 4 1-2. What's the Calibration Curve?... 4 2. Specifications... 5 3. How To Use... 6 3-1. Installation... 7 3-2. Measurement... 7 4. How to connect the main unit to cable and Communication Function... 8 4-1. Specification of main unit connector... 8 4-2. Specification of RS-232C Cable... 9 4-3. Communication Function... 9 5. Troubleshooting... 10

1. Features 1-1. Measurement Principle The absorption band of water has three wavelengths in the near-infrared spectrum area, 1.2, 1.45, 1.94 micrometers. When a sample is irradiated with light of those wavelengths, the sample will absorb light in an amount commensurate with its moisture content. The sample's moisture content determines how much light the sample will absorb. this moisture content can therefore be determined by measuring the light attenuation produced by the sample. However, when measured only absorption wavelength, it can not measured stably since influence of the surface state of the material, the size of the particles, the color, etc. Therefore, the KB-30 is using also reference wavelength which is hardly affected by water. Reflectance 1.5 2.0 [μm] wavelength λ water spectrum 1-2. What's the Calibration Curve? NIR moisture meter is measuring the moisture content by converts from the near-infrared absorption degree of the object. To do this be required the formula for converting. This conversion formula is the calibration curve. The calibration curve depend on absorption characteristics of the measurement object. Therefore, It must be created for per each object before measurement. * Please contact to your dealer, if you would like to know how to make calibration curve. * Please use proper calibration curve that is made for each sample correctly. Absorbance Sample A Sample B Sample D Sample C Moisture content (%) 4

2. Specification Measurement method : NIR reflectance / Absorbance Light source : Tungsten lamp Measurement distance : 260mm ± 30mm Measurement diameter : 25mm in diameter at 260mm distance Max. number of sensor heads : 30 Number of calibration curves : 50 Analog current output : 4-20mA DC External communications : RS-232C / RS-485 Ambient temperature / humidity : 5-35 C / 30-80% RH (without condensation) Power source : AC 100-240V (50 / 60Hz) consumption : 50W Dimensions / Weight : 268(W) 306(H) 140(D) mm, 7.0 kg (including the hood and cables) Accessories : Options : Reference plate, Power cable, RS-232C cable (2.9m), Bolts and washers set, Operation manual, PC software, PC software, Operation manual for PC software All stainless steel body, Special spec for high moisture object, Cooling box <Accessories> Reference plate Power cable RS-232C cable (2.9m) Bolts x4 pcs (M6x12mm) Spring washers x4 pcs Washers x4 pcs NIR Moisture Analyzer KB-30 Operation Manual Bolts and washers set Operation manual PC software Operation manual for PC software 5

3. How To Use Please read before use Calibration curve It is necessary to set the calibration curve to the unit before measurement. Please make the calibration curve by the supplied PC software, then set it to the unit. The ground of power cable There is a risk of fire or electric shock if the ground wire of the power cable is not grounded. When outlet is 2 pins, use the conversion plug for ground. When outlet is 3 pins and it is grounded, KB-30 will be ground automatically. Vibration in environment> KB-30 should be installed in a place where vibration is small as possible. If it will be installed in a place where there is vibration, should be suppress the vibration by separating the installation stand of KB-30 from the vibration source. Environmental temperature KB-30 must be used in 5 to 35 C ambient temperature. If your environment is not in this range, it is required the system to separate the ambient temperature from environment temperature, such as optional Cooling box which can be receive the cooling dry air to inside. Moisture KB-30 must be used in the place where has no condensation. In case that KB-30 is used in the place where has much moisture or high salinity, there is a risk of corrosion and oxidation of the connector part and so on. Please do regular checks and cleaning. Protection against dust The air purge hood is installed KB-30. If you would like to use it in the place where there is much dust, we recommend air purge. Please use external diameter 6mmφ tube to connect air source such as pump and compressor. (The tube is not attached. Please prepare by yourself.) The standard of amount used of air is 0.5-1.0 kg/cm2 (about 70-140NL/min). Please use clean dry air without water and oil when you use air purge. Sunlight Please use KB-30 after the light-blocking treatment, because the strong light as direct sunlight will disturb the measurement. Consumable goods We recommend the replacement of consumable goods (Filter Wheel Motor, Lamp) every two years to maintain the accuracy. Please don't replace them by yourself. Please contact to your dealer. Inspection when you do not use KB-30 for a long time (6 months or more), if you want to use it again, we recommend the inspection of KB-30. Please contact to your dealer. * If KB-30 is installed in a place where corrosive gas is generated, it may cause a malfunction. If you would like to install it in such a place, please contact to your dealer in advance. 6

3-1. Installation (1) The setting of height The height from the sample surface to the bottom of main unit must be 260mm (±20mm). Bolt hole (4 places) <Glossy sample> The bottom of main unit 460mm Measurement diameter about Φ25mm Belt conveyor 260mm (±20mm) Sample surface Measurement diameter about Φ25mm It is recommended that is at an angle of 10-15 C to sample surface. Belt conveyor (2) Fixation of bolt Fasten the instrument with 4 bolts between the surface that you install the instrument and the bolt hole of the upper surface of the main unit after adjusting the height. * Fasten sensor head tightly with 4 bolts, attached washers and spring washers. If you do not so, it may cause injury due to falling. The case that attached bolts is used. (M6 12mm) The thickness of the surface that you install the instrument must be from 2 to 4mm. Bolt hole (4 places) The case that the thickness of the surface you install the instrument is more than 4mm Considering the thickness of the surface you install the instrument, and then calculate the length of bolts. L = [ 5 + (1.5+1.6) + t ] ± 1 (mm) L : The length of bolt t : The length of angle (1.5+1.6) : (The thickness of spring washer+the thickness of washer) 3-2. Measurement Turn on the power to start the measurement. The channel number and the moisture value is displayed. The channel number and the moisture value is displayed. 7

4. How to connect the main unit to cable and Communication Function 4-1. Specification of main unit connector (1) AC connector (2) RS-232C/ RS-485 connector (3) 4-20mA connector Arrangement of connector and connector pin Connector kind Connector Type Pin arrangement (1) AC connector Connect power cable NJW203-RM (JP version) 1 L NJW203-RM-UL / CSA (US version) 2 N NEW203-RM (EN version) 3 F.G 1 RS-485 (+) 2 RS-485 ( ) 3 GND (2) RS-232C/RS-485 connector Connect the RS-232C cable or RS- 485 cable that is connected to PC. NJW168-RF 4 RS-232C (RXD) 5 RS-232C (TXD) 6 I/F_MODE (+) 7 I/F_MODE ( ) * * 8 F.G (3) 4-20mA connector connect the cable that pick out an output electric current that is NJW163-RF 1 4-20mA(+) 2 4-20mA( ) correspond to the moisture value of measurement sample. 3 F.G * When you use RS-232C communication, connect I/F_MODE (+) and (-). 8

4-2. Specification of RS-232C Cable <Main unit> <PC> NJW Plug (Pin) 1 NC 2 NC 3 GND 4 RS-232C (RXD) Main unit D sub 9 pin (female) 1 NC 2 RS-232C (RXD) 3 RS-232C (TXD) 4 NC 5 RS-232C (TXD) 6 I/F_MODE (+) 7 I/F_MODE ( ) 8 F. PC 5 GND 6 NC 7 RS-232C (RTS) 8 RS-232C (CTS) 9 NC 4-3. Communication Function KB-30 can do RS-232C/RS-485 communication with the PC by the serial port on the back of the main unit. It is possible to send measurement commands from the PC to the main unit and reply measurement data from the main unit to the PC (it is necessary to prepare the PC and communication software). Please contact to your dealer if you would like to know detailed communication specification. 9

5. Troubleshooting If there is an abnormality in the unit or use conditions, you receive the following error code. Please take appropriate action in follow the instructions. If occurred an error code which is not in the notation, please contact to your dealer. * If an error occurs, please disconnect the instrument and your system immediately. If you continue to use, that it may be an adverse effect on the system. Error code Description Action E01 The sample reflectance is too low. It is conceivable that the sample is too far, the lamp is burn out or has been degraded, or other trouble in the unit. 1. Confirm the distance to the sample. 2. Replace the lamp if it has been burn out. 3. Contact to your dealer. E02 Ambient temperature is too high. Confirm ambient temperature. E03 Ambient temperature is too low. Confirm ambient temperature. E04 Absorbance trouble Contact to your dealer. E05 Motor rotation speed trouble. Contact to your dealer. E07 Calibration curve coefficient in the measurement channel is not set yet. Set calibration curve coefficient from PC software. E08 It is abnormal at zero calibration coefficient or temperature compensation coefficient. Memory of the system constant has been destroyed. Contact to your dealer. E09 Memory of the channel constant has been destroyed. Contact to your dealer. E12 Can not read the analog signal. Contact to your dealer. 10