Medium Voltage Fuses. Medium Voltage Fuses 64. R Rated Medium Voltage Fuses E Rated Medium Voltage Fuses 69-73

Similar documents
MEDIUM VOLTAGE FUSES. POWR-GARD Fuse Datasheet. 2,400-38,000 VAC Current-Limiting

Section Overview. Table of Contents

JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B. R-Rated Fuses For Motor Circuit Protection Medium Voltage.

ECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less

TRADITIONAL HIGH-SPEED FUSES

R Rated Motor Fuses. DD mm. Dimensions - Standard. Dimensions - B bolt-in. Other Medium Voltage Products. Head Office

10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT

L50QS SERIES HIGH-SPEED ROUND BODY FUSES

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Installation Instructions

TeSys IEC Contactors and Overload Relays

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Ferrule fuse-links 10x38 gg 400 to 690VAC

AMP-TRAP Form 101 A15QS

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY

FLQ SERIES MIDGET (10x38mm) FUSES

ELSP current-limiting backup fuse

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC

H704-42(H)(E), H704-42/1(H)(E)

Metering Devices IQ 300

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

Figure 1. ELSP Current-Limiting Backup Fuse. INSTALLATION

Voltage Dip-Proofing Inverter

Bulletin 1489 Circuit Breakers. Selection Guide

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

ELSP current-limiting backup fuse

COOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)

WMS SUPPLEMENTARY PROTECTORS

Sensing and Control the Interactive Catalog.

K-Line Mini - Contactors, Overload Relays and Accessories

high RESISTANCE STOPLIGHT Instruction Manual C-101EM

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Digital I/O Modules. Installation Instructions. (Catalog Number 1746 Series)

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

170 ADI VDC - 16 Pt. Discrete Input Module Base

Applying branch circuit breakers and supplementary protectors in North America

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Voltage Dip-Proofing Inverter

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Specifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Miniature Circuit Breakers and Supplementary Protectors. Contents

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

170 ADO VDC - 32 Pt. Discrete Output Module Base

MINI-BEAM SM2A312CV and SM2A312CV2

Installation Instructions

UL 489 DIN Rail Miniature Circuit Breakers

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

8 Submersible Motors Standard

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

UL 489 DIN Rail Miniature Circuit Breakers

NETRONICS HS3500 CONTROLLER

4. CIRCUIT BREAKERS. Functional Emergency Switching

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

IELR Series

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Distributed Power System SA3100 Drive Configuration and Programming

DNP Points List and Implementation

Discrete Output Modules IC697MDL740

CERTIFIED TEST REPORT

802B Compact, Precision and Small Precision

EDR-3000 Eaton Distribution Relay

Supplement to Instruction Manual

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

Spring Test 5 due 4/26/2013

Instruction Manual HPH-8

60103 Circuit Breaker

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

ICS Regent. AC Guarded Digital Output Module 110 VAC (T3464) PD-6021

IC693PWR331 High Capacity Power Supply, 24 VDC Input

S66 Series Electronic Fan Speed Control

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

IELR Rail-Mount Series Magnetic Circuit Protectors

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

SECTION 12. Miscellaneous. AEMC Electro Industries EMM, Inc. Graphic Controls Osaki Yokogawa (YCA) Woertz

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

PACSystems* RX3i IC695PSA040

WiAutoLink Frequently Asked Questions

ELECTROSÓN. ZA Series. Features. Radial Lead Metal-Oxide Varistors for Low to Medium Voltage Operation. [ /Title (ZA Series) /Subject

SMALL GENERATOR INTERCONNECTION REQUEST. (Application Form)

Installation Instructions

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Product Guide. UL 489 DIN rail miniature circuit breakers

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

LDN Series Laser Diode Drivers

Electrical Plan Review

Transcription:

64 R Rated 65-68 Rated 69-73 Rated Potential Transformer Fuses 74 Live Parts 75

2,400-38,000 VAC General Information Current-limiting and R rated fuses are equipped with a mechanical indicator or striker pin that protrudes through the fuse cap upon operation of the fuse. This provides visual identification of a blown fuse and can be used as a trigger for external devices. Note: xtension distance 1 /2 min; extension force 2lb. min The terms Medium Voltage and High Voltage have been used interchangeably by many people to describe fuses operating above 600 volts. Technically speaking, medium voltage fuses are those intended for the voltage range from 2,400 to 38,000 VAC. High voltage fuses are for circuits carrying voltages greater than 38,000 VAC. rated fuses are considered to be general purpose fuses and can be used to protect against low and high values of fault current. R rated fuses are designed for back-up protection. They must be used in series with other devices such as motor overload relays in order to achieve both overload and short-circuit protection. Littelfuse now offers a complete selection of and R rated medium voltage fuses for the protection of trans formers, potential transformers, feeders, and motor circuits. Single, double, and triple barrel designs are available to cover a wide range of current, voltage, and interrupting ratings. Conventional ferrule type, clip lock, and bolt-in mounting configurations are now available for virtually any application. Hermetically sealed fuses for use in hazardous environments are also offered. Contact the factory or your local Littelfuse representative for additional fuse ratings or custom mounting configurations. Medium voltage fuses are not intended to provide overload protection in the same sense as fuses rated 600 volts or less. Medium voltage fuse current ratings do not have the same meanings as the ampere ratings of low voltage fuses. All medium voltage fuses are limited in their ability to interrupt low value overcurrents, especially those between 100% and 200% of the fuse s continuous current rating. They are designed to carry their rated current without exceeding the temperature rise permitted by NMA and ANSI standards. Additional application data can be found in the Fuse Application section of this catalog. 24 Hour mergency Service is available. Call 847 824 1188. Applications Power Transformer Protection Potential Transformer Protection Motor Controller Back-up Protection Fused Switches Feeder Circuits Bolt-in Mount Fuses 64

R Rated Features R rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large shortcircuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating. Characteristics Voltage Rating: Current Range: Options 2,400 volts 8,250 volts 2R 36R Hermitically sealed for use in hazardous locations (add S suffix to part number) Bolt-in mounting configurations NMA Standards for R rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes. Part System 130-4R-1C-5.5 Max Voltage (KV) Style (C-Cartridge) No. of Barrels Rating (size) Continuous Current Hookeye Feature* * For hookeye attachment; add W suffix to part number 3"DIA 6.38" 9.75" Clip Center D DD DDD 1 2 3 R Rated 2.75 KV Old Size Maximum Continuous Current @ 40 deg C. Dim. A Dim. B Min. Interrupting Rating RMS Amps Max Interrupting Rating RMS Asym 70-2R-1C-2.75 LCK 2R 2R 70 7" 10.875" 170 80,000 1 100-3R-1C-2.75 LCK 3R 3R 100 7" 10.875" 250 80,000 1 130-4R-1C-2.75 LCK 4R 4R 130 7" 10.875" 340 80,000 1 150-5R-1C-2.75 LCK 5R 5R 150 7" 10.875" 390 80,000 1 170-6R-1C-2.75 LCK 6R 6R 170 7" 10.875" 500 80,000 1 200-9R-1C-2.75 LCK 9R 9R 200 7" 10.875" 760 80,000 1 230-12R-1C-2.75 LCK 12R 12R 230 7" 10.875" 1000 80,000 1 390-18R-2C-2.75 LCK 18R 18R 390 7" 10.875" 1500 80,000 2 450-24R-2C-2.75 LCK 24R 24R 450 7" 10.875" 1950 80,000 2 Add w suffix to part number for hookeye attachment. 65

R Rated 3"DIA 6.38" 9.75" (Clip Center) 4 5 6 R Rated 5.5 KV 5.5 KV 14 Clip Centers Old Size Maximum Continuous Current @ 40 Degrees C Dim. A Dim. B Min. Interrupting Rating RMS Amps Max Interrupting 70-2R-1C-5.5 LCL 2R 2R 70 12" 15.875" 170 80,000 4 100-3R-1C-5.5 LCL 3R 3R 100 12" 15.875" 250 80,000 4 130-4R-1C-5.5 LCL 4R 4R 130 12" 15.875" 340 80,000 4 150-5R-1C-5.5 LCL 5R 5R 150 12" 15.875" 390 80,000 4 170-6R-1C-5.5 LCL 6R 6R 170 12" 15.875" 500 80,000 4 200-9R-1C-5.5 LCL 9R 9R 200 12" 15.875" 760 80,000 4 230-12R-1C-5.5 LCL 12R 12R 230 12" 15.875" 1000 80,000 4 390-18R-2C-5.5 LCL 18R 18R 390 12" 15.875" 1500 80,000 5 450-24R-2C-5.5 LCL 24R 24R 450 12" 15.875" 1950 80,000 5 480-26R-2C-5.5 26R 480 12" 15.875" 2100 80,000 5 550-30R-2C-5.5 30R 550 12" 15.875" 2400 80,000 5 600-32R-2C-5.5 32R 600 12" 15.875" 2600 80,000 5 650-36R-2C-5.5 36R 650 12" 15.875" 2900 80,000 5 550-30R-3C-5.5 30R 550 12" 15.875" 2400 80,000 6 600-32R-3C-5.5 32R 600 12" 15.875" 2600 80,000 6 650-36R-3C-5.5 LCL 36R 36R 650 12" 15.875" 2900 80,000 6 70-2R-1C-5.5X 2R 70 14" 17.875" 170 80,000 4 100-3R-1C-5.5X 3R 100 14" 17.875" 250 80,000 4 130-4R-1C-5.5X 4R 130 14" 17.875" 340 80,000 4 150-5R-1C-5.5X 5R 150 14" 17.875" 390 80,000 4 170-6R-1C-5.5X 6R 170 14" 17.875" 500 80,000 4 200-9R-1C-5.5X 9R 200 14" 17.875" 760 80,000 4 230-12R-1C-5.5X 12R 230 14" 17.875" 1000 80,000 4 390-18R-2C-5.5X 18R 390 14" 17.875" 1500 80,000 5 450-24R-2C-5.5X 24R 450 14" 17.875" 1950 80,000 5 550-30R-2C-5.5X 30R 550 14 17.875 2400 80,000 5 R Rated 8.25 KV Old Size Maximum Continuous Current @ 40 Degrees C Dim. A Dim. B Min. Interrupting Rating RMS Amps Max Interrupting 70-2R-1C-8.25 2R 70 12" 15.875" 190 80,000 4 100-3R-1C-8.25 3R 100 12" 15.875" 225 80,000 4 130-4R-1C-8.25 4R 130 12" 15.875" 330 80,000 4 150-5R-1C-8.25 5R 150 12" 15.875" 440 80,000 4 170-6R-1C-8.25 6R 170 12" 15.875" 500 80,000 4 200-9R-1C-8.25 9R 200 12" 15.875" 740 80,000 4 230-12R-1C-8.25 12R 230 12" 15.875" 955 80,000 4 390-18R-2C-8.25 18R 390 12" 15.875" 1440 80,000 5 450-24R-2C-8.25 24R 450 12" 15.875" 1910 80,000 5 Add w suffix to part number for hookeye attachment. 66

R Rated Littelfuse POWR-GARD medium voltage fuses are available in several bolt-in mounting configurations. Contact factory for custom configurations. B BI IB Bolt mount Bolt-In mount Inverted-Bolt mount Refer to illustrations for mounting dimensions. Indicator (2).34" X.660 Slots 1.38" Apart 3" Dia. Indicator Indicator 3" Dia. Indicator (2).34" Holes 1.38" Apart 7 8 9 10 Bolt Mount B Inverted-Bolt IB R Rated 2.75 KV Bolt Mount B 2.75 KV Inverted Bolt IB Old Size Maximum Continuous Current @ Degrees C Dim. A Dim. B Min. Interrupting Max Interrupting Rating RMS Amps 70-2R-1B-2.75 2R 70 4.6" 13" 170 80,000 7 00-3R-1B-2.75 3R 100 4.6" 13" 250 80,000 7 30-4R-1B-2.75 4R 130 4.6" 13" 240 80,000 7 150-5R-1B-2.75 5R 150 4.6" 13" 390 80,000 7 170-6R-1B-2.75 6R 170 4.6" 13" 500 80,000 7 200-9R-1B-2.75 9R 200 4.6" 13" 760 80,000 7 230-12R-1B-2.75 12R 230 4.6" 13" 1000 80,000 7 390-18R-2B-2.75 18R 390 7.4" 13" 1500 80,000 8 450-24R-2B-2.75 24R 450 7.4" 13" 1950 80,000 8 70-2R-1IB-2.75 2R 70 13" 170 80,000 9 100-3R-1IB-2.75 3R 100 13" 250 80,000 9 130-4R-1IB-2.75 4R 130 13" 340 80,000 9 150-5R-1IB-2.75 5R 150 13" 390 80,000 9 170-6R-1IB-2.75 6R 170 13" 500 80,000 9 200-9R-1IB-2.75 9R 200 13" 760 80,000 9 230-12R-1IB-2.75 12R 230 13" 1000 80,000 9 390-18R-2IB-2.75 18R 390 13" 1500 80,000 10 450-24R-2IB-2.75 24R 450 13" 1950 80,000 10 67

R Rated.44" X.91" Slots (1.53" c.t.c.) 3"Dia. Indicator Indicator Bolt-In Mount BI R Rated 5.5 KV Bolt In Mount BI 5.5 KV Bolt Mount B 5.5 KV Inverted Bolt IB 8.25 KV Bolt-In Mount BI Old Front View Size Maximum Continuous Current @ 40 C. Dim. A Dim. B Min. Interrupting Max Interrupting Rating RMS Amps 70-2R-1BI-5.5 2R 70 3.6 18" 170 80,000 11 100-3R-1BI-5.5 3R 100 3.6 18" 250 80,000 11 130-4R-1BI-5.5 4R 130 3.6 18" 340 80,000 11 150-5R-1BI-5.5 5R 150 3.6 18" 390 80,000 11 170-6R-1BI-5.5 6R 170 3.6 18" 500 80,000 11 200-9R-1BI-5.5 9R 200 3.6 18" 760 80,000 11 230-12R-1BI-5.5 12R 230 3.6 18" 1000 80,000 11 390-18R-2BI-5.5 18R 390 7.6 18" 1500 80,000 12 450-24R-2BI-5.5 24R 450 7.6 18" 1950 80,000 12 480-26R-2BI-5.5 26R 480 7.6 18" 2200 80,000 12 550-30R-2BI-5.5 30R 550 7.6 18" 2400 80,000 12 600-32R-2BI-5.5 32R 600 7.6 18" 2650 80,000 12 650-36R-2BI-5.5 36R 650 7.6 18" 2900 80,000 12 550-30R-3BI-5.5 30R 550 18" 80,000 13 600-32R-3BI-5.5 32R 600 18" 80,000 13 650-36R-3BI-5.5 36R 650 18" 80,000 13 700-38R-3BI-5.5 38R 700 18" 80,000 13 70-2R-1B-5.5 2R 70 4.6 18" 170 80,000 7 100-3R-1B-5.5 3R 100 4.6 18" 250 80,000 7 130-4R-1B-5.5 4R 130 4.6 18" 340 80,000 7 150-5R-1B-5.5 5R 150 4.6 18" 390 80,000 7 170-6R-1B-5.5 6R 170 4.6 18" 500 80,000 7 200-9R-1B-5.5 9R 200 4.6 18" 760 80,000 7 230-12R-1B-5.5 12R 230 4.6 18" 1000 80,000 7 390-18R-2B-5.5 18R 390 7.4 18" 1500 80,000 8 450-24R-2B-5.5 24R 450 7.4 18" 1950 80,000 8 550-30R-2B-5.5 30R 550 8.4 18" 2400 80,000 8 600-32R-2B-5.5 32R 600 8.4 18" 2650 80,000 8 650-36R-2B-5.5 36R 650 8.4 18" 2900 80,000 8 70-2R-1IB-5.5 2R 70 18" 170 80,000 9 100-3R-1IB-5.5 3R 100 18" 250 80,000 9 130-4R-1IB-5.5 4R 130 18" 340 80,000 9 150-5R-1IB-5.5 5R 150 18" 390 80,000 9 170-6R-1IB-5.5 6R 170 18" 500 80,000 9 200-9R-1IB-5.5 9R 200 18" 760 80,000 9 230-12R-1IB-5.5 12R 230 18" 1000 80,000 9 390-18R-2IB-5.5 18R 390 18" 1500 80,000 10 450-24R-2IB-5.5 24R 450 18" 1950 80,000 10 550-30R-2IB-5.5 30R 550 18" 2400 80,000 10 600-32R-2IB-5.5 32R 600 18" 2650 80,000 10 650-36R-2IB-5.5 36R 650 18" 2900 80,000 10 70-2R-1BI-8.25 2R 70 3.6 18" 190 80,000 11 100-3R-1BI-8.25 3R 100 3.6 18" 225 80,000 11 130-4R-1BI-8.25 4R 130 3.6 18" 330 80,000 11 150-5R-1BI-8.25 5R 150 3.6 18" 400 80,000 11 170-6R-1BI-8.25 6R 170 3.6 18" 500 80,000 11 200-9R-1BI-8.25 9R 200 3.6 18" 740 80,000 11 230-12R-1BI-8.25 12R 230 3.6 18" 955 80,000 11 390-18R-2BI-8.25 18R 390 7.6 18" 1440 80,000 12 450-24R-2BI-8.25 24R 450 7.6 18" 1910 80,000 12 11 12 13 68

Rated Rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. NMA Standards for rated medium voltage fuses require that fuses rated 100 or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an rating larger than 100 must open within 600 seconds (10 minutes) when subjected to an RMS current of 220-240% of the fuse s continuous current rating. These values establish one point on the time-current curve. Characteristics Voltage Rating: 2,400 volts 38,000 volts Current Range: 10 600 Options Hermetically sealed for use in hazardous locations (add S suffix to part number) Clip-lock (CL) and bolt-in styles available. Application Note: Since these fuses are used for the protection of general purpose circuits which may contain transformers, motors, and other equipment producing in-rush and/or overload currents, fuses should generally be rated at 140% of the normal full load current, and circuits should be analyzed to ensure that system load currents will not exceed the current rating of the fuse. (Clip Center) 3"DIA 6.38" 9.75" 14 15 16 Rated Old Size Dim. A Dim. B Max Interrupting 2.75 Max. KV 10-1C-2.75 LCX 10 10 7" 10.875" 80,000 14 15-1C-2.75 15 7" 10.875" 80,000 14 20-1C-2.75 20 7" 10.875" 80,000 14 25-1C-2.75 25 7" 10.875" 80,000 14 30-1C-2.75 LCX 30 30 7" 10.875" 80,000 14 40-1C-2.75 LCX 40 40 7" 10.875" 80,000 14 50-1C-2.75 LCX 50 50 7" 10.875" 80,000 14 65-1C-2.75 LCX 65 65 7" 10.875" 80,000 14 80-1C-2.75 LCX 80 80 7" 10.875" 80,000 14 100-1C-2.75 LCX 100 100 7" 10.875" 80,000 14 125-1C-2.75 125 7" 10.875" 80,000 14 150-1C-2.75 150 7" 10.875" 80,000 14 200-1C-2.75 200 7" 10.875" 80,000 14 125-2C-2.75 LCX 125 125 7" 10.875" 80,000 15 150-2C-2.75 LCX 150 150 7" 10.875" 80,000 15 175-2C-2.75 LCX 175 175 7" 10.875" 80,000 15 200-2C-2.75 LCX 200 200 7" 10.875" 80,000 15 225-2C-2.75 225 7" 10.875" 80,000 15 250-2C-2.75 LCX 250 250 7" 10.875" 80,000 15 300-2C-2.75 LCX 300 300 7" 10.875" 80,000 15 350-2C-2.75 350 7" 10.875" 80,000 15 400-2C-2.75 LCX 400 400 7" 10.875" 80,000 15 450-2C-2.75 450 7" 10.875" 80,000 15 69

Rated Rated Old Size Dim. A Dim. B Max Interrupting Diagram 10-1C-5.5 10 12" 15.875" 80,000 14 15-1C-5.5 15 12" 15.875" 80,000 14 20-1C-5.5 20 12" 15.875" 80,000 14 25-1C-5.5 25 12" 15.875" 80,000 14 30-1C-5.5 LCY 30 30 12" 15.875" 80,000 14 40-1C-5.5 LCY 40 40 12" 15.875" 80,000 14 50-1C-5.5 LCY 50 50 12" 15.875" 80,000 14 65-1C-5.5 LCY 60 65 12" 15.875" 80,000 14 80-1C-5.5 LCY 80 80 12" 15.875" 80,000 14 100-1C-5.5 LCY 100 100 12" 15.875" 80,000 14 125-1C-5.5 LCY 125 125 12" 15.875" 80,000 14 150-1C-5.5 LCY 150 150 12" 15.875" 80,000 14 175-1C-5.5 LCY 175 175 12" 15.875" 80,000 14 200-1C-5.5 LCY 200 200 12" 15.875" 80,000 14 125-2C-5.5 125 12" 15.875" 80,000 15 150-2C-5.5 150 12" 15.875" 80,000 15 175-2C-5.5 175 12" 15.875" 80,000 15 200-2C-5.5 200 12" 15.875" 80,000 15 250-2C-5.5 LCY 250 250 12" 15.875" 80,000 15 300-2C-5.5 LCY 300 300 12" 15.875" 80,000 15 350-2C-5.5 LCY 350 350 12" 15.875" 80,000 15 400-2C-5.5 LCY 400 400 12" 15.875" 80,000 15 450-2C-5.5 LCY 450 450 12" 15.875" 80,000 15 500-3C-5.5 500 12" 15.875" 80,000 16 550-3C-5.5 550 12" 15.875" 80,000 16 600-3C-5.5 600 12" 15.875" 80,000 16 5.5 Max. KV 5.5 Max. KV 5NL-10 10 14 17 7 8" 80,000 14 5NL-15 15 14 17 7 8" 80,000 14 5NL-20 20 14 17 7 8" 80,000 14 5NL-25 25 14 17 7 8" 80,000 14 5NL-30 LCU 30 30 14 17 7 8" 80,000 14 5NL-40 LCU 40 40 14 17 7 8" 80,000 14 5NL-50 LCU 50 50 14 17 7 8" 80,000 14 5NL-65 LCU 65 65 14 17 7 8" 80,000 14 5NL-80 LCU 80 80 14 17 7 8" 80,000 14 5NL-100 LCU 100 100 14 17 7 8" 80,000 14 5NL-125 LCU 125 125 14 17 7 8" 80,000 14 5NL-150 LCU 150 150 14 17 7 8" 80,000 14 5NL-175 LCU 175 175 14 17 7 8" 80,000 14 5NL-200 LCU 200 200 14 17 7 8" 80,000 14 5NL2-225 225 14 17 7 8" 80,000 15 5NL2-250 LCU 250 250 14 17 7 8" 80,000 15 5NL2-300 LCU 300 300 14 17 7 8" 80,000 15 5NL2-350 LCU 350 350 14 17 7 8" 80,000 15 5NL2-400 LCU 400 400 14 17 7 8" 80,000 15 5NL2-450 LCU 450 450 14 17 7 8" 80,000 15 70

Rated Rated Old Size Dim. A Dim. B Max Interrupting Diagram 10-1C-8.25 10 12" 15 7 8" 80,000, 14 15-1C-8.25 15 12" 15 7 8" 80,000 14 20-1C-8.25 20 12" 15 7 8" 80,000 14 25-1C-8.25 25 12" 15 7 8" 80,000 14 30-1C-8.25 LDZ 30 30 12" 15 7 8" 80,000 14 40-1C-8.25 LDZ 40 40 12" 15 7 8" 80,000 14 50-1C-8.25 LDZ 50 50 12" 15 7 8" 80,000 14 65-1C-8.25 LDZ 65 65 12" 15 7 8" 80,000 14 80-1C-8.25 LDZ 80 80 12" 15 7 8" 80,000 14 100-1C-8.25 LDZ 100 100 12" 15 7 8" 80,000 14 125-1C-8.25 LDZ 125 125 12" 15 7 8" 80,000 14 150-1C-8.25 LDZ 150 150 12" 15 7 8" 80,000 14 125-2C-8.25 LDZ 125 125 12" 15 7 8" 80,000 15 150-2C-8.25 LDZ 150 150 12" 15 7 8" 80,000 15 200-2C-8.25 LDZ 200 200 12" 15 7 8" 80,000 15 250-2C-8.25 LDZ 250 250 12" 15 7 8" 80,000 15 300-2C-8.25 LDZ 300 300 12" 15 7 8" 80,000 15 350-3C-8.25 LDZ 350Z 350 12" 15 7 8" 80,000 16 400-3C-8.25 400 12" 15 7 8" 80,000 16 8.25 Max. KV 8.25 Max. KV 8NL-10 10 14" 17 7 8" 80,000 14 8NL-15 15 14" 17 7 8" 80,000 14 8NL-20 20 14" 17 7 8" 80,000 14 8NL-25 25 14" 17 7 8" 80,000 14 8NL-30 LCZ 30 30 14" 17 7 8" 80,000 14 8NL-40 LCZ 40 40 14" 17 7 8" 80,000 14 8NL-50 LCZ 50 50 14" 17 7 8" 80,000 14 8NL-65 LCZ 65 65 14" 17 7 8" 80,000 14 8NL-80 LCZ 80 80 14" 17 7 8" 80,000 14 8NL-100 LCZ 100 100 14" 17 7 8" 80,000 14 8NL2-100 LCZ 100 100 14" 17 7 8" 80,000 14 8NL2-125 LCZ 125 125 14" 17 7 8" 80,000 15 8NL2-150 LCZ 150 150 14" 17 7 8" 80,000 15 8NL2-200 LCZ 200 200 14" 17 7 8" 80,000 15 8NL2-250 250 14" 17 7 8" 80,000 15 Rated Old Size Dim. A Dim. B Max Interrupting 10-1C-15.5 LDN 10 10 15" 18.875" 80,000 14 15-1C-15.5 LDN 15 15 15" 18.875" 80,000 14 20-1C-15.5 LDN 20 20 15" 18.875" 80,000 14 25-1C-15.5 LDN 25 25 15" 18.875" 80,000 14 30-1C-15.5 LDN 30 30 15" 18.875" 80,000 14 40-1C-15.5 LDN 40 40 15" 18.875" 80,000 14 50-1C-15.5 LDN 50 50 15" 18.875" 80,000 14 65-1C-15.5 LDN 65 65 15" 18.875" 80,000 14 80-1C-15.5 LDN 80 80 15" 18.875" 80,000 14 100-1C-15.5 LDN 100 100 15" 18.875" 80,000 14 65-2C-15.5 65 15" 18.875" 80,000 15 80-2C-15.5 80 15" 18.875" 80,000 15 100-2C-15.5 100 15" 18.875" 80,000 15 125-2C-15.5 125 15" 18.875" 80,000 15 150-2C-15.5 LDN 150 150 15" 18.875" 80,000 15 175-2C-15.5 LDN 175 175 15" 18.875" 80,000 15 200-2C-15.5 200 15" 18.875" 80,000 15 200-3C-15.5 200 15" 18.875" 80,000 16 250-3C-15.5 250 15" 18.875" 80,000 16 300-3C-15.5 300 15" 18.875" 80,000 16 15.5 Max. KV 71

Rated Rated Old Size Dim. A Dim. B Max Interrupting 15GS-65 65 18" 21 7 8" 60,000 14 15GS-80 80 18" 21 7 8" 60,000 14 15GS-100 100 18" 21 7 8" 60,000 14 15GS2-125 125 18" 21 7 8" 60,000 15 15GS2-150 150 18" 21 7 8" 60,000 15 15GS2-175 175 18" 21 7 8" 60,000 15 15GS2-200 200 18" 21 7 8" 60,000 15 15.5 Max. KV 15.5 Max. KV 15NL-10 10 20" 23 7 8" 60,000 14 15NL-15 15 20" 23 7 8" 60,000 14 15NL-20 20 20" 23 7 8" 60,000 14 15NL-25 25 20" 23 7 8" 60,000 14 15NL-30 LCN 30 30 20" 23 7 8" 60,000 14 15NL-40 LCN 40 40 20" 23 7 8" 60,000 14 15NL-50 LCN 50 50 20" 23 7 8" 60,000 14 15NL-65 LCN 65 65 20" 23 7 8" 60,000 14 15NL-80 LCN 80S 80 20" 23 7 8" 60,000 14 15NL-100 LCN 100S 100 20" 23 7 8" 60,000 14 15NL2-80 LCN 80 80 20" 23 7 8" 60,000 15 15NL2-100 LCN 100 100 20" 23 7 8" 60,000 15 15NL2-125 LCN 125X 125 20" 23 7 8" 60,000 15 15NL2-150 LCN 150 150 20" 23 7 8" 60,000 15 15NL2-175 175 20" 23 7 8" 60,000 15 15NL2-200 LCN 200D 200 20" 23 7 8" 60,000 15 15NL3-150 150 20" 23 7 8" 60,000 16 15NL3-175 175 20" 23 7 8" 60,000 16 15NL3-250 250 20" 23 7 8" 60,000 16 15NL3-300 300 20" 23 7 8" 60,000 16 Rated Old Size Dim. A Dim. B Max Interrupting 15-1C-25.8 15 21" 24 5 8" 40,000 14 20-1C-25.8 20 21" 24 5 8" 40,000 14 25-1C-25.8 25 21" 24 5 8" 40,000 14 30-1C-25.8 30 21" 24 5 8" 40,000 14 40-1C-25.8 40 21" 24 5 8" 40,000 14 50-1C-25.8 50 21" 24 5 8" 40,000 14 65-2C-25.8 65 21" 24 5 8" 40,000 14 80-2C-25.8 80 21" 24 5 8" 40,000 15 100-2C-25.8 100 21" 24 5 8" 40,000 15 25.8 Max. KV Rated Old Size Dim. A Dim. B Max Interrupting 3-1C-38.0 3 27" 30 5 8" 20,000 14 7-1C-38.0 7 27" 30 5 8" 20,000 14 10-1C-38.0 10 27" 30 5 8" 20,000 14 15-1C-38.0 15 27" 30 5 8" 20,000 14 20-1C-38.0 20 27" 30 5 8" 20,000 14 25-1C-38.0 25 27" 30 5 8" 20,000 14 30-1C-38.0 30 27" 30 5 8" 20,000 14 40-1C-38.0 40 27" 30 5 8" 20,000 14 50-2C-38.0 50 27" 30 5 8" 20,000 15 65-2C-38.0 65 27" 30 5 8" 20,000 15 80-2C-38.0 80 27" 30 5 8" 20,000 15 38 Max. KV 72

Rated 4.75 7.94 11.56 Clip Lock Design The clip lock type designs ensures a positive contact between the fuse and the connection cam. The fuse s clip lock tab slides in between the clip casting and the cam to prevent the fuse from slipping or blowing out of the holder. This positive contact improves heat dissipation and allows fuses to run cooler. Rated Old Size Dim. A Dim. B Max Interrupting 10-1CL-5.5 10 16.38" 15.13" 80,000 17 15-1CL-5.5 15 16.38" 15.13" 80,000 17 20-1C-5.5 20 16.38" 15.13" 80,000 17 25-1CL-5.5 25 16.38" 15.13" 80,000 17 30-1CL-5.5 30 16.38" 15.13" 80,000 17 40-1CL-5.5 40 16.38" 15.13" 80,000 17 50-1CL-5.5 50 16.38" 15.13" 80,000 17 65-1CL-5.5 65 16.38" 15.13" 80,000 17 80-1CL-5.5 80 16.38" 15.13" 80,000 17 100-1CL-5.5 100 16.38" 15.13" 80,000 17 125-1CL-5.5 125 16.38" 15.13" 80,000 17 150-1CL-5.5 150 16.38" 15.13" 80,000 17 225-2CL-5.5 225 17.38" 16.13" 80,000 18 250-2CL-5.5 250 17.38" 16.13" 80,000 18 300-2CL-5.5 300 17.38" 16.13" 80,000 18 350-2CL-5.5 350 17.38" 16.13" 80,000 18 400-2CL-5.5 400 17.38" 16.13" 80,000 18 450-2CL-5.5 450 17.38" 16.13" 80,000 18 500-3CL-5.5 500 17.38" 16.13" 80,000 19 550-3CL-5.5 550 17.38" 16.13" 80,000 19 600-3CL-5.5 600 17.38" 16.13" 80,000 19 5.5 Max. KV Clip Lock Rated Old Size Dim. A Dim. B Max Interrupting 10-1CL-8.25 10 17.38" 16.13" 80,000 17 15-1CL-8.25 15 17.38" 16.13" 80,000 17 20-1C-8.25 20 17.38" 16.13" 80,000 17 25-1CL-8.25 25 17.38" 16.13" 80,000 17 30-1CL-8.25 30 17.38" 16.13" 80,000 17 40-1CL-8.25 40 17.38" 16.13" 80,000 17 50-1CL-8.25 50 17.38" 16.13" 80,000 17 65-1CL-8.25 65 17.38" 16.13" 80,000 17 80-1CL-8.25 80 17.38" 16.13" 80,000 17 100-1CL-8.25 100 17.38" 16.13" 80,000 17 125-2CL-8.25 125 17.38" 16.13" 80,000 18 150-2CL-8.25 150 17.38" 16.13" 80,000 18 175-2CL-8.25 175 17.38" 16.13" 80,000 18 200-2CL-8.25 200 17.38" 16.13" 80,000 18 225-2CL-8.25 225 17.38" 16.13" 80,000 18 250-2CL-8.25 250 17.38" 16.13" 80,000 18 300-2CL-8.25 300 17.38" 16.13" 80,000 18 350-3CL-8.25 350 17.38" 16.13" 80,000 19 8.25 Max. KV Clip Lock Rated Old Size Dim. A Dim. B Max Interrupting 10-1CL-15.5 10 19.8" 18.1" 60,000 17 15-1CL-15.5 15 19.8" 18.1" 60,000 17 20-1CL-15.5 20 19.8" 18.1" 60,000 17 25-1CL-15.5 25 19.8" 18.1" 60,000 17 30-1CL-15.5 30 19.8" 18.1" 60,000 17 40-1CL-15.5 40 19.8" 18.1" 60,000 17 50-1CL-15.5 50 19.8" 18.1" 60,000 17 65-1CL-15.5 65 22.81" 21.13" 60,000 17 80-1CL-15.5 80 22.81" 21.13" 60,000 17 100-1CL-15.5 100 22.81" 21.13" 60,000 17 125-2CL-15.5 125 22.81" 19.1" 60,000 18 150-3CL-15.5 150 22.81" 19.1" 60,000 19 175-3CL-15.5 175 22.81" 19.1" 60,000 19 200-3CL-15.5 200 22.81" 19.1" 60,000 19 225-3CL-15.5 225 22.81" 19.1" 60,000 19 250-3CL-15.5 250 22.81" 19.1" 60,000 19 300-3CL-15.5 300 22.81" 19.1" 60,000 19 15.5 Max. KV Clip Lock A B 1.25 1.25 17 18 19 3.0.25 73

Rated Potential Transformer Fuses Potential Transformer (PT) fuses are current-limiting fuses with high interrupting ratings designed for the protection of potential transformers. Application Note: When applying fuses for the protection of transformers, the magnetizing current in-rush must be considered. The characteristics of the in-rush, which can be matched with a fuse time-current curve, should be available from the transformer manufacturer. Characteristics Voltage Rating: 600VAC 25,500 VAC Current Range: 1/2 10 B A Rated Old Size Length Dim. A Diameter Dim. B Max Interrupting Rating RMS (Sym) 3-4PT-6 3 4.6 0.8125 37,500 5-4PT-6 5 4.6 0.8125 37,500 7-4PT-6 7 4.6 0.8125 37,500 10-4PT-6 10 4.6 0.8125 37,500 600 Volt 2.75 Max. kv 2.75 Max.KV 500-4PT-2.4 1/2 4.6 0.8125 37,000 1-4PT-2.4 LCD 1-4 1 4.6 0.8125 37,000 2-4PT-2.4 LCD 2-4 2 4.6 0.8125 37,000 1-6PT-2.75 1 7.4 1.5625 37,500 2-6PT-2.75 2 7.4 1.5625 37,500 3-6PT-2.75 3 7.4 1.5625 37,500 1-8PT-2.75 1 9.5 1.5625 37,000 2-8PT-2.75 2 9.5 1.5625 37,000 3-8PT-2.75 3 9.5 1.5625 37,000 4.8 Max. kv 5.5 Max. kv 8.25 Max. kv 15.5 Max. kv 25.8 Max. kv 1-5PT-4.8 LC 1-4 1 5.6 0.8125 50,000 2-5PT-4.8 LC 2-4 2 5.6 0.8125 50,000 1/2-6PT-5.5 1/2 7.4 1.5625 50,000 1-6PT-5.5 1 7.4 1.5625 50,000 2-6PT-5.5 2 7.4 1.5625 50,000 3-6PT-5.5 3 7.4 1.5625 50,000 5-6PT-5.5 5 7.4 1.5625 50,000 1/2-8PT-5.5 LCQ.5 1/2 9.5 1.5625 50,000 1-8PT-5.5 LCQ 1 1 9.5 1.5625 50,000 2-8PT-5.5 LCQ 2 2 9.5 1.5625 50,000 3-8PT-5.5 LCQ 3 3 9.5 1.5625 50,000 5-8PT-5.5 LCQ 5 5 9.5 1.5625 50,000 10-8PT-5.5 LCQ 10 10 9.5 1.5625 50,000 1/2-8PT-8.25 1/2 9.5 1.5625 50,000 1-8PT-8.25 1 9.5 1.5625 50,000 2-8PT-8.25 2 9.5 1.5625 50,000 3-8PT-8.25 3 9.5 1.5625 50,000 1/2-11PT-15.5 LCT.5 1/2 12.8 1.5625 35,000 1-11PT-15.5 LCT 1 1 12.8 1.5625 35,000 2-11PT-15.5 LCT 2 2 12.8 1.5625 35,000 3-11PT-15.5 LCT 3 3 12.8 1.5625 35,000 3-16PT-15.5 3 17.5 1.5625 35,000 5-16PT-15.5 5 17.5 1.5625 35,000 1/2-16PT-25.5 LCJ 1-4 1/2 17.5 1.5625 43,500 1-16PT-25.5 LCJ 2-4 1 17.5 1.5625 43,500 74

Live Parts Live parts are available for mounting, R, and PT single, double, and triple barrel fuses. Mounting clips are available for ferrule type and clip lock style fuses. All clips are sold in pairs. Contact factory for additional live parts. Part : 700-156* System : 0700156.Z For use with 1-9 / 16" to 1-5 /8 (1.625 ) diameter PT fuses. Part : 700-300* System : 0700300.Z For use with 3" diameter fuses. 2.00 3.74 2.85 Part : 700-500* System : 0700500.Z For use with all 13 / 16" (.8125 ) diameter PT fuses..08 Part : 700-530* System : 0700530.Z For use with all 3" diameter fuses..31.78.71.30.08.038" HOLS 1.15.05 1.50 3.08 4.50 4.16.78.63 Part : 700-520-CL* System : 0700520.ZXCL Clip Lock Design (For CL-14) Mounting Details for Clip Lock 3.63 TRIPL BARRL 3.63 DOUBL BARRL Bottom Lever In Closed Position * One Pair. Dimensions for reference only. Blown Fuse Indicator 2.00 4.9 TOP VIW 4.85 3.75 2.00 Top Lever in Open Position SINGL BARRL 1.00 A 2.00 1.75.56 Dia. (2) Holes For Mounting Cable/Bus.44 DIA. (2) HOLS 75