INTEGRATED VOICE EVACUATION SYSTEM

Similar documents
INTEGRATED VOICE EVACUATION SYSTEM

INTEGRATED VOICE EVACUATION SYSTEM

EN60849/IEC60849 compliant

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series

VM VX SX-2000 Integrated Voice Alarm Management & Evacuation Systems

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

AUDIO MANAGEMENT SYSTEM

INTEGRATED VOICE EVACUATION SYSTEM VX-2000 series

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

TOA Net Price List PROFESSIONAL USER

N-8000 SERIES IP INTERCOM SYSTEM

Digital Mixing System D-2000 Series

Contents. Appearance of AC Plug and Voltage CU 314L US UL 120 L V AC

ex 800A Series ematrix System

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Automated Remote Messaging ARM-911A RM-911D RM-911W

INFRARED WIRELESS CONFERENCE SYSTEMS

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

D-901 ALL-IN-ONE MODULAR DIGITAL MIXER

VIPEDIA-12. Cameo specification sheet. Product Description

N-8000 Series IP Intercom System

SOUND REPEATER EV-20R

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

TOA ELECTRIC CO., LTD.

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

IDA8C. Networkable PAVA system Controller Unit. IDA8 System

9000M2 SERIES MODULAR DIGITAL MATRIX MIXER AND MIXER/AMPLIFIERS H IGHLIGHTS

IP Intercom System. N-8000 Series. Sounding bells, stamping feet, screaming children yet still be notified clearly and in good time of every danger.

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

MX X 250W AMPLIFIED MASTER UNIT

CLOUD CX261 Single Zone Mixer

PRODUCT LINEUP CATALOG

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

OPERATING INSTRUCTIONS PA AMPLIFIER A-1706 A-1712 A-1724

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

DIGITAL VIDEO RECORDING SYSTEM Single-Channel Digital Video Recorders and Multiplexers

MPS01. Paging and Emergency Microphone

VM SERIES Rackmount 100V mixer-amplifiers

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

8 x 8 Audio Matrix with Local Control PX (With RM-8000/LM-8000)

AMP20. User Manual.

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier

M-1264 M-1212E STEREO MIXERS. TOA Corporation OPERATING INSTRUCTIONS. TOA 1000 series CAUTION

USB MP3 MIXING AMPLIFIER MA-206U/212U/224U

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

MU 9186R MASTER UNIT WITH ROUTER

MPS10 - MPS50. Modular Paging and Emergency Microphones

Infrared Wireless Conference System

Sound-over-Ethernet. User Guide. Linked via Cat5 cable Up to 1000m! 11/09

PAGING HORN SPEAKERS SC-630/SC-630M. Both high-impedance (70V/100V lines) models and lowimpedance (8Ω) models available.

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

CLOUD , MEDIA, T, TMEDIA 4-ZONE INTEGRATED MIXER AMPLIFIERS

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

PXR 1506 / WATT MIXER AMPLIFIER

User's Manual. DADS-MB701 In Vehicle Automatic Announcement System. Version 1.1, Revised 19, January Doc

SMART Audio classroom amplification systems Model CAS-340

IP-9000 IP Network Audio System. Features:

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

The Music Lovers Line. Integrated Amplifier Receiver NEW PRODUCT BULLETIN

Emergency Voice Evacuation and Mass Notification Systems COOKBOOK

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

ASP-MG2240. Amplified Sound Masking System

AMP100 AMP102 AMP110 AMP210 AMP310

UHF WIRELESS MICROPHONE SYSTEMS

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

W W. Public Address & Voice Evacuation System. Flexible and scalable configuration Fully digitalised audio transmission

MIC-2 MKII, Multi-instrument DATA SHEET

Overview. Digital Audio Matrix System NPX System

ProMatrix TM. PM3180 Digitally Matrixed Amplifier

QM-AE1. QuickMedia Audio Extractor

1073N. Channel Amplifier. User Manual Issue 1.3

HORECA140BK. Plug & Play Audio Set ECLER TECHNICAL DATA SHEET AUDIO SETS

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

The Music Lovers Line. Integrated Amplifier Receiver NEW PRODUCT BULLETIN

PRE116/126. User Manual.

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

V-9908 MESSAGE/PAGE PANEL

T-60FP/T-120FP Mixer Amplifier

Multimedia digital audio mixer

MCS 50. Discussion Control Unit. 1 of 7

DCN23 Digital Crossover with 2 inputs and 3 outputs

PREMIUMAUDIOVIDEOANDPOWERPRODUCTS V-RVC-PRO. Owners Manual

SL Interpreter Compact

WIDE-DISPERSION SPEAKER SYSTEM F-1000/F-2000 SERIES

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

A-2060D/ DD SERIES A-2120D/ DD/ DT SERIES A-2240D/ DD/ DT SERIES

TELIKOU Intercom System

Installation & Operation Guide

PAM-60/PAM-120 Public Address Amplifier. Copyright 2004 Inter-M Corporation

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

IMPORTANT SAFETY INSTRUCTIONS

Simply Communicate. Analog Partyline Systems

EMS10 - EMS50. Cameo specification sheet. Product Description

FLP-MA-120U / MA-240U

TitanONE Smart Mainframe Power Amplifier

Transcription:

INTEGRATED VOICE EVACUATION SYSTEM VX-2000 SERIES DESCRIPTION The TOA VX-2000 Series broadcast system is designed for both generalpurpose and emergency broadcasts. It is comprised of the System Manager, Surveillance Frame, Power Amplifiers, Power Supply unit, Emergency Power Supply, and a user-specified number of Remote Microphones. The system complies with the EN60849 Standard and its failure detection circuitry operates continuously to check components and speaker lines for any irregularities. If detected, failure warnings are provided by way of an LED indicator and a buzzer. FEATURES Microprocessor-controlled 4 audio signal bus matrix system comprising System Manager VX-2000 for the input signal matrix and Surveillance Frame for the output signal matrix. Max. 18 inputs {8 input slots, 8 Remote Microphones including Fireman s Mic, 2 EVs (Voice Announcement Board) and Chime} and 50 output zones (max. 5 Surveillance Frames) available. Two different emergency messages (Alert and Evacuation) simultaneously available if 2 EV-200 cards are installed. Surveillance function for the critical speech path from the microphone element of Fireman s Microphone(s) to each speaker line fully complies with the IEC (EN) 60849 standard. Speaker line surveillance method can be independently selected for each speaker line (Pilot tone detection or impedance check) Any surveillance function will not interrupt BGM distribution and paging announcements. PC software available for easy system configuring and parameter setting. Weekly program timer function for scheduled events. (10-Day Programs of 32 events each, 40 Holiday Programs, setting daylight saving time and adjusting time setting) Monitor bus system allows Remote Monitoring of the audio signal on output zones. Standard configuration of 16 control inputs and 16 control outputs can be expanded up to 128 inputs and outputs. A standby amplifier can be reserved for each Surveillance Frame. All-call function still available at Fireman s Microphone(s) even with CPU failure. All Remote Microphone (Fireman s Microphone) switches are assignable function switches. LEDs on the Remote Microphone (Fireman s Microphone) can be set as Fault Indicators. Remote Microphone (Fireman's Microphone) function switches with 2 LEDs can be expanded up to 105 per unit (with RM-210 Remote Microphone Extension Units). Software-driven logging function records the last 2000 events and downloads data to a PC. Printable software-driven Setting list and Block Diagram of Project System configuration and connection check function available during system installation. 9-band Graphic EQ card available for each output zone. DC power supply for whole system excluding BGM sources minimizes use of AC cables. System failures are automatically detected such as general power amplifier failures and faults as well as DC fuse failures and power amplifier thermal faults. Power amplifier standby function maximizes battery-powered operation time. Inspection mode can be activated on setting software for emergency operation without requiring actual broadcasting. Automatically cuts power consumption when using the battery power supply.

VX-2000 System Manager The VX-2000 System Manager is an input matrix unit that assigns input signals to 4 audio buses, and functions as the VX-2000 system's main controller. A total of up to 8 units of the VX-200XI, VX-200XR, and 900 Series input modules can be mounted in a System Manager. The VX-2000 can control audio signal routing, priorities, and peripheral equipment, while input and output control settings are performed by way of a PC. Up to 2,000 system events and failures can also be recorded, and the log can be viewed from a PC. Rear Panel APPEARANCE AND DIMENSIONAL DIAGRAM 482 465 420 Front view without front panel 337 320 Side View 57.2 4 6 10 Current consumption Input Audio Link Output Monitor Output S/N Ratio Distortion Cross Talk Control Input Control Output Chime Tone Communication System Operating Temperature Option * 0 db = 1 V Note: LONWORKS is a trademark of Echelon Corporation. VX-2000 System Manager 24V DC (operating range: 20 40V DC) M3.5 screw terminal, distance between barriers: 8.8m Under 650mA (20V DC) 20dB*, unbalanced, Number of module slots: 8 Usable module: VX-200XR, VX-200XI, 900 series plug-in modules (M-01F, M-01M, M-01P, M-01S, M-03P, M-51F, M-51S, M-61F, M-61S, U-01F, U-01P, U-01R, U-01S, M-03R, U-03S, U-61S) Number of audio buses: 4 0dB*, electronically balanced, RJ45 female connector 0dB*, electronically balanced, XLR receptacle (3 pins) 20 20,000Hz Over 60dB Under 0.5% Under 60dB (1kHz, 0dB*) 16 inputs, no-voltage make contact, open voltage: 17V DC, Short circuit current: Under 5mA, RJ45 connector x 2 16 outputs, open collector output, withstand voltage: 30V DC, Control current: Under 5mA, RJ45 connector x 2 Built-in chime: 4-tone chime (up)/4-tone chime (down)/2-tone chime/gong PC (Setting software to be installed): D-sub connector (9 pins), cross cable, RS-232C : RJ45 female connector, Twisted-pair straight cable (TIA/EIA-568A standard), LONWORKS RS-485 0 C to +40 C Panel: Surface-treated steel plate, black, 30% gloss, paint 482 (W) x (H) x 337 (D)mm 6.4kg Rack mounting bracket (preinstalled on the unit) x 2, Rack mounting screw x 4, Fiber washer x 4, Blank panel x 7, Blank panel mounting screw x 14, Setting software installation CD x 1, Fuse (T1.6A L) x 1/(T6.3A L) x 1 Voice announcement board: EV-200, Isolation transformer: IT-450 (audio link output)

Surveillance Frame The Surveillance Frame is the output matrix section of the VX-2000 system that assigns audio signals to individual zones from 4 audio buses. It can be extended to up to 5 units. A total of 10 units of output modules and control modules can be installed per. The following 4 types of modules can be used: the VX-200SP Pilot Tone Detection module, the VX-200SZ Impedance Detection module, the VX-200SI Control Input module, and the VX-200SO Control Output module. Rear Panel APPEARANCE AND DIMENSIONAL DIAGRAM 482 465 420 4 6 10 Front view without front panel 337 57.2 Number of Slot S/N Ratio Distortion Cross Talk Audio Link Input/Output Standby Amplifier Link Communication System Operating Temperature Option Surveillance Frame 24V DC (operating range: 20 40V DC) M3.5 screw terminal, distance between barriers: 8.8m Under 2A (40V DC) 10, usable modules: VX-200SZ, VX-200SP, VX-200SI, VX-200SO 20 20,000Hz (when use VX-200SZ: 120 20,000Hz) Over 60dB Under 0.5% Under 60dB (1kHz, 0dB*) Number of audio busses: 4 0dB*, electronically balanced, RJ45 female connector Twisted-pair straight cable (TIA/EIA-586A standard) RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Twisted-pair straight cable (TIA/EIA-586A standard) VX-2000, : RJ45 female connector x 2, LONWORKS RS-485 VX-2000DS: RJ45 female connector x 2, Twisted-pair straight cable (TIA/EIA-586A standard) 0 C to +40 C Panel: Surface-treated steel plate, black, 30% gloss, paint 482 (W) x (H) x 337 (D)mm 5.6kg Rack mounting bracket (preinstalled on the unit) x 2, Rack mounting screw x 4, Fiber washer x 4, Blank panel x 9, Blank panel mounting screw x 18, Standby amp. cable (3m) x 1 Isolation transformer: IT-450 (audio link output) * 0 db = 1 V Note: LONWORKS is a trademark of Echelon Corporation. Side View

RM-200XF Fireman s Microphone RM-200X Remote Microphone A dedicated microphone for the VX-2000 system, the RM-200XF is designed to be exclusively used for emergency broadcast, however it can be used for general-purpose broadcast applications as well. The RM-200X is a dedicated unit for the VX-2000 system, and permits emergency broadcast as well as general-purpose broadcast. 200 82.5 215 76.5 100 46 Wall mounting 5 ø4.5 bracket (accessory) ø60 (opening for cable entry) 293 215 Audio Output Hand-Held Microphone Distortion S/N Ratio Internal Monitor Speaker Volume Control Number of Function Keys Key Extension Number of Connectable Units Communication System Connection Cable and Connector Communication Distance Applicable Box *0 db = 1 V Note: LONWORKS is a trademark of Echelon Corporation. 83.5 3 4.5 6 Plug-in screw terminal (accessory) RM-200XF Wall mounting bracket (accessory) RM-200XF Fireman's Microphone 24V DC (operating range: 16 40V DC) Under 200mA (RM-200XF), 850mA (with 10 RM-210s connected) 0dB*, 600Ω, balanced Dynamic microphone, Function switch (default: Press-to-talk), Microphone element fault detection Under 1% 200 15,000Hz Over 55dB 200mW Microphone volume control, Monitor speaker volume control 5 (including Hand-held microphone's switch), extendable up to 105 (with 10 RM-210s connected) 10 keys extension per RM-210, EXTENSION connector 4 LONWORKS twisted pair free topology transceiver Category 5 STP cable, plug-in screw connector 500m (Free topology wiring) ABS resin, blueish gray (PANTONE 538 or its equivalent) 200 (W) x 215 (H) x 82.5 (D)mm (excluding the coiled cord) 1.2kg Plug-in screw terminal x 1, Wall mounting bracket x 1, Wall mounting screw x 2, Box mounting screw x 2 YC-301, YS-11A 190 Audio Output Gooseneck Microphone External Microphone Input Distortion S/N Ratio Internal Monitor Speaker Volume Control Number of Function Keys Key Extension Number of Connectable Units Communication System Connection Cable and Connector Communication Distance *0 db = 1 V Note: LONWORKS is a trademark of Echelon Corporation. RM-200X Remote Microphone 24V DC (operating range: 16 40V DC), supplied from RJ45 connector or power input jack (non-polarity type) Usable power input plug: 5.5mm outer diameter, 2.1mm inner diameter, and 9.5mm long. Under 200mA (RM-200X), 750mA (with 9 RM-210s connected) 0dB*, 600Ω, balanced, RJ45 connector Unidirectional electret condenser microphone 40dB*, 2.2kΩ, unbalanced, mini jack, phantom powering Under 1% 100 20,000Hz Over 60dB 200mW Microphone volume control, Monitor speaker volume control 15, extendable up to 105 (with 9 RM-210s connected) 10 keys extension per RM-210, EXTENSION connector 8 (include RM-200XF) LONWORKS twisted pair free topology transceiver Category 5 STP cable, RJ45 connector 500m (Free topology wiring) ABS resin, blueish gray (PANTONE 538 or its equivalent) 190 (W) x 76.5 (H) x 215 (D)mm (gooseneck microphone excluded) 850g

RM-210 Remote Microhone Extension S-20S Sound Repeater The RM-210 is an extension unit for increasing the number of function keys of TOA's RM-200M, RM-200XF and RM-200X Remote Microphones. The S-20S is EV module to be used in conjunction with VX-2000. Up to 4 types of music and messages (3 minites total time) can be recorded and played back. The USB port facilitiates recording by transferring the supplied sound sources from a PC to the unit. 110 76.5 215 35 9.5 88 78 Connection Number of Function Keys Function WB-RM200 Wall Mounting Bracket The WB-RM200 is to mount RM-200X, RM-200M and RM-210 on the wall. : Surface-treated steel plate, black paint : 100g RM-210 Remote Microphone Extension 20mA max. (in terms of RM-200M's DC power input) 75mA max. (interms of DC power inputs of RM-200X and RM-200XF) Connection to RM-200M, RM-200X or RM-200XF by way of dedicated cable 10 When used to expand the RM-200M: Selects and activates the Voice Announcement Board messages. When used to expand the RM-200X and RM-200XF (PC software setting): Emergency activation, emergency reset, BGM pattern selection, EV message activation, broadcast zone selection, monitor zone selection, chime activation, Talk switch activation, control output activation, input volume adjustment, zone volume adjustment, and failure output indication and reset. ABS resin, blueish gray (PANTONE 538 or its equivalent) 110 (W) x 76.5 (H) x 215 (D)mm 350g Extension cable x 1, Linkage bracket A x 2, Linkage bracket B x 1, Screw for linkage bracket x 12 Output Wave Format Distortion Recording System Control Input Maximum No. of Messages Maximum Recording Time Playback Interval Time Operating Temperature USB Data Transfer Software Operation Environment Personal Computer Main Specifications OS S-20S Sound Repeater 24V DC Under 40mA 0dB* 44.1kHz sampling frequency, 16-bit PCM (monaural) 50 to 20,000Hz, ±3dB (1kHz) Under 1% (1kHz) USB data transfer Play 1-4, stop: Non-voltage make contact input, pulse make length: 200 ms, open voltage: 24V DC, short-circuit current: 2mA, removable terminal block ( 6 pins) 4 3 min, 0s, 5s, 10s, 30s, 1 min, 5 min, 10 min, 30 min or 1h (selectable) 0 C to +50 C Panel: Aluminum, hairline 35 (W) x 78 (H) x 88 (D)mm 65g CD-ROM (USB data transfer software and sample chimes recorded) x 1, USB cable (1m) x 1, Removable terminal plug (6 pins) x 1, Mounting screw x 2 IBM-AT compatible type (equipped with the USB terminal) CPU: Pentium compatible CPU of 133MHz or more/ Memory: Over 64MB (recommended: 128MB or more)/ Free disk space: Over 10MB (space for message storage excluded) Windows 2000/XP *0dB = 1V Note: Pentium is a trademake of Intel Corporation. Windows is a trademake of Microsoft Corporation. Other company names and products are also trademakes of individual companies.

VX-200XI Audio Input with Control Input VX-200XR Remote Microphone Input The VX-200XI module is designed to be used in conjunction with the VX-2000 System Manager, and comes with control input terminals, low-cut and high-cut filters, and gain controls. The VX-200XR module is designed to be used with the RM-200X Remote Microphone or RM-200XF Fireman's Microphone. Insert one of these modules into the VX-2000's input module slot for each Remote or Fire Microphone used in the system. 35 88 78.5 35 88 78.5 78 78 Input Sensitivity (Rated Output 20dB) Low Cut Filter (100Hz) High Cut Filter (10kHz) Distortion Phantom Power Control Input Input Connector Option * 0 db = 1 V VX-200XI Audio Input with Control Input Supplied from VX-2000 Under 30mA MIC: 70 to 42.5dB* (adjustable) LINE: 20 to +7.5dB* (adjustable) MIC or LINE selectable by the built-in switch 9 to 15dB attenuation (adjustable) 8 to 14dB attenuation (adjustable) Under 0.5% 50 20,000Hz 15V (open), 6V (current consumption: 3.3mA) No-voltage make contact, open voltage: 17V DC, short-circuit current: Under 5mA RJ45 female connector Panel: Aluminum, hairline 35 (W) x 78 (H) x 88 (D)mm 70g Mounting screw x 2 Isolation transformer: IT-450 VX-2000 Connectable Remote Microphone Input Connector VX-200XR Remote Microphone Input Supplied from VX-2000 Under 17mA RM-200X and RM-200XF RJ45 female connector Panel: Aluminum, hairline 35 (W) x 78 (H) x 88 (D)mm 70g Mounting screw x 2 VX-2000

VX-200SZ Impedance Detection VX-200SZ-2 Impedance Detection The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault. The VX-200SZ-2 is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault. Since the mosule is equipped with 2 speaker outputs (A and B), broadcasts can be maintained even if one of the two outputs fails. Failures are indicated by the LED on the panel. 30.5 290.3 280.9 30.5 290.3 280.9 75 75 Power Amplifier Link External Attenuator Control Output Speaker Output Power Amplifier Input Fault Detection System Option VX-200SZ Impedance Detection Supplied from Under 150mA RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Plug-in screw connector, relay, no-voltage make contact output, transfer type, withstand voltage: 30V DC, 250V AC, contact current: Under 7A (DC), under 7A (AC) Applicable cable diameter: AWG24 AWG 22 Plug-in screw connector Applicable cable diameter: AWG24 AWG 22 Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Applicable cable diameter: AWG24 AWG 22 Short circuit, open circuit (impedance detection method), ground fault Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 320g Plug-in screw terminal x 1 Equaliser card: VX-200SE Power Amplifier Link External Attenuator Control Output Speaker Output Power Amplifier Input Fault Detection System Option VX-200SZ-2 Impedance Detection Supplied from Under 170mA RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Plug-in screw connector, relay, no-voltage make contact output, transfer type, withstand voltage: 30V DC, 250V AC, contact current: Under 7A (DC), under 7A (AC) Applicable cable diameter: AWG 24 AWG 16 2 outputs (A, B), plug-in screw connector Applicable cable diameter: AWG 24 AWG 16 Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Applicable cable diameter: AWG 24 AWG 16 Short circuit, open circuit (impedance detection method), ground fault Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 335g Plug-in screw terminal x 1 Equaliser card: VX-200SE

VX-200SP Pilot Tone Detection VX-200SP-2 Pilot Tone Detection The VX-200SP is an audio signal output module of the VX-2000 system with speaker line pilot tone detection. This module is to be mounted in the Surveillance Frame and detects speaker line short circuits, open circuits by monitoring for the presence of a pilot signal, and ground fault. The VX-200SP-2 is an audio signal output module of the VX-2000 system with speaker line pilot tone detection. This module is to be mounted in the Surveillance Frame and detects speaker line short circuits, open circuits by monitoring for the presence of a pilot signal, and ground fault. Connecting the supplied line to the end of the speaker line eliminates the necessity of using the speaker line for line monitoring. However, the shielded cable must be used for the speaker line. 30.5 290.3 280.9 30.5 75 290.3 280.9 75 End of line unit (accessory) 70 60 35 45 4 ø4 Power Amplifier Link Line Monitor External Attenuator Control Output Speaker Output Power Amplifier Input Fault Detection System Option VX-200SP Pilot Tone Detection Supplied from Under 100mA RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Plug-in screw connector Applicable cable diameter: AWG 24 AWG 22 Plug-in screw connector, relay, no-voltage make contact output, transfer type, withstand voltage: 30V DC, 250V AC, contact current: Under 7A (DC), under 7A (AC) Applicable cable diameter: AWG24 AWG 22 Plug-in screw connector Applicable cable diameter: AWG 24 AWG 22 Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Applicable cable diameter: AWG 24 AWG 22 Short circuit, open circuit (pilot tone detection method), ground fault Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 240g Plug-in screw terminal x 1 Equaliser card: VX-200SE Power Amplifier Link Line Monitor* External Attenuator Control Output Speaker Output Power Amplifier Input Fault Detection System Option VX-200SP-2 Pilot Tone Detection Supplied from Under 100mA RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Plug-in screw connector Applicable cable diameter: AWG 24 AWG 16 Plug-in screw connector, relay, no-voltage make contact output, transfer type, withstand voltage: 30V DC, 250V AC, contact current: Under 7A (DC), under 7A (AC) Applicable cable diameter: AWG 24 AWG 16 Plug-in screw connector Applicable cable diameter: AWG 24 AWG 16 Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241, VP-2421 Power Amplifier. Applicable cable diameter: AWG 24 AWG 16 Short circuit, open circuit (pilot tone detection method), ground fault Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 235g Plug-in screw terminal x 1, End of line unit x 1 Equaliser card: VX-200SE End of line unit (accessory) Supplied from the VX-200SP-2 (Generated by 40Hz sine wave) Speaker Line Connections Plug-in connector In Case of Normal Terminated by 470kΩ between the speaker line and the shield In Case of Open Opened between the speaker line and shield 22g * Connect to Speaker Output.

VX-200SO Control Output VX-200SI Control Input TOA's VX-200SO Control Output is used to increase the number of control outputs to be used in the VX-2000 system. It features 16 control outputs and is mounted in the Surveillance Frame. TOA's VX-200SI Control Input is used to increase the number of control inputs to be used in the VX-2000 system. It features 16 control inputs and is mounted in the Surveillance Frame. 30.5 290.3 280.9 30.5 290.3 280.9 112 112 Control Output VX-200SO Control Output Supplied from Under 150mA 16 outputs, no-voltage make contact, contact capacity: 28V DC, 1A, RJ45 connector Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 250g Control Input VX-200SI Control Input Supplied from Under 100mA 16 inputs, no-voltage make contact, open voltage: 24V DC, short circuit current: under 10mA, RJ45 connector Panel: Surface-treated steel plate 30.5 (W) x (H) x 290.3 (D)mm 200g

VX-200SE Equaliser Card EV-200 Voice Announcement Board The VX-200SE Equaliser is a 9-band, 1-channel equaliser to be mounted on the circuit board of the VX-200SP Pilot Tone Detection module or VX-200SZ Impedance Detection module. The EV-200 is a playback-only Voice Announcing board to play back the messages recorded on TOA's EV-350R. The EV-200 is designed to built in the VX-2000. 110 21.4 90 120 18.6 MAX.15 121 Equaliser Centre Frequency Gain Range VX-200SE Equaliser Card Supplied from VX-200SZ, VX-200SP Under 50mA 80Hz, 125Hz, 250Hz, 500Hz, 1kHz, 2kHz, 4kHz, 8kHz, 12kHz ±12dB, adjustable in 2dB steps 110 (W) x 90 (H) x 11.7 (D)mm 50g VX-200SZ, VX-200SP Power Consumption Output Distortion Memory Card Playback Mode No. of Playback Program Operating Temperature Operating Humidity EV-200 Voice Announcement Board 24 V DC, 0.2 A 5 W 0 db* 1 20 20,000 Hz (44.1 khz sampling) 20 14,000 Hz (32 khz sampling) Under 0.3% (44.1 khz, recording method: Extremely High) SanDisk* 2 CompactFlash* 2 card is optionally required. Number of mountable card: 1 Single source playback 8 programs 0 C to +50 C Less than 90% (must be free from dew condensation) 120 (W) x 18.6 (H) x 121 (D) mm 110 g Mounting screw 2 * 1 0 db = 1 V * 2 Trademark of SanDisk Corporation. Note: Use the CompactFlash card adapter on the market for recording by the EV-350R.

Power Amplifiers VP-2064 (VP-2421) Power Amplifier uses the VP-200VX Power Amplifier Input per channel. 482 465 4 6 10 76.2 88.4 CHARACTERISTIC DIAGRAMS EXAMPLE 340.5 320 Deviation (dbr A) +10 +8 +6 +4 +2 +0-2 -4-6 -8-10 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) Product Name = VP-2064 Normalized to 0dB at 1kHz Deviation (dbr A) +10 +8 +6 +4 +2 +0-2 -4-6 -8 (MONITOR OUTPUT) -10 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) Product Name = VP-2064 Normalized to 0dB at 1kHz VP-2122 T.H.D. (%) 10 5 2 1 0.5 0.2 0.1 0.05 0.02 T.H.D vs Power Output 0.01 1µ 2µ 5µ 20µ 100µ 1m 10m 100m 1 2 5 10 20 50 200 1k Product Name = VP-2064 Input frequency = 100Hz Filters = 22Hz 20kHz Power Output (W) Output 1 Output 2 Output 3 Output 4 T.H.D. (%) T.H.D vs Power Output 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 1µ 2µ 5µ 20µ 100µ 1m 10m 100m 1 2 5 10 20 50 200 1k Power Output (W) Output 1 Product Name = VP-2064 Output 2 Input frequency = 1kHz Output 3 Filters = 22Hz 20kHz Output 4 VP-2241 T.H.D. (%) 10 5 2 1 0.5 0.2 0.1 0.05 0.02 T.H.D vs Power Output 0.01 1µ 2µ 5µ 20µ 100µ 1m 10m 100m 1 2 5 10 20 50 200 1k Product Name = VP-2064 Input frequency = 10kHz Filters = 22Hz 20kHz Power Output (W) Output 1 Output 2 Output 3 Output 4 VP-2421 (EN60065) Rated Output Power Output Voltage/Impedance Number of Channels Input Number of Slots Output Distortion S/N Ratio Panel Indicator Operating temperature VP-2064 Power Amplifier 4 60W 4.8A in total 60W x 4 100V/167Ω, 70V/83Ω, 50V/41Ω (selectable by the internal wiring change) 4 4, usable module: VP-200VX Channel power indicator: 4 channels, dual colour LED Overheat indicator: Yellow LED 11.2kg VP-2122 Power Amplifier 2 120W VP-2241 Power Amplifier 1 240W VP-2421 Power Amplifier 1 420W 28V DC (operating range: 20 40V DC) M4 screw terminal, distance between barriers: 12mm 120W x 2 100V/83Ω, 70V/41Ω, 50V/21Ω (selectable by the internal wiring change) 4.8A 240W 100V/41Ω, 70V/21Ω, 50V/10Ω (selectable by the internal wiring change) 7.6A 420W 100V/24Ω, 70V/12Ω, 50V/6Ω (selectable by the internal wiring change) 2 1 Specified by input module VP-200VX 2, usable module: VP-200VX 1, usable module: VP-200VX Power amplifier output (speaker line): M3.5 screw terminal, distance between barriers: 8.8mm 40 16,000Hz, ±3dB (at 1/3 rated output) Under 1% (at rated output, 1kHz) Over 80dB Channel power indicator: 2 channels, dual colour LED Overheat indicator: Yellow LED Channel power indicator: 1 channels, dual colour LED Overheat indicator: Yellow LED 0 to +40 C Panel: Surface-treated steel plate, black, 30% gloss, paint 482 (W) x 88.4 (H) x 340.5 (D)mm 9.1kg 8.1kg 9.5kg Rack mounting screw x 4, Fiber washer x 4

VP-200VX Power Amplifier Input VX-2000DS Emergency Power Supply The VP-200VX Power Amplifier Input is designed to be used in conjunction with thevp-2064, VP-2122, VP-2241 or VP-2421 power amplifier. The VX-2000DS Emergency Power Supply unit supplies the DC power to each equipment in the VX-2000 system by connecting the VX-200PS Power Supply Unit. It keeps the battery unit that contains 2 12 V sealed lead batteries charged compensating for the temperature of the battery charging voltage. When the DC power supply from the VX-200PS stops, the VX-2000DS is automatically switched to the backup battery. APPEARANCE AND DIMENTIONAL DIAGRAM APPEARANCE AND DIMENTIONAL DIAGRAM 482 465 76.2 88.4 88 73.2 71.5 2.6 377.6 320 25.8 Power Amplifier Link VP-200VX Power Amplifire Input Supplied from VP-2064, VP-2122, VP-2241 or VP-2421 Under 30 ma RJ45 female connector for connecting the VX-200SP or VX-200SZ Audio Output module. Panel: Surface-treated steel plate 88 (W) x 25.8 (H) x 73.2 (D) mm 50g VP-2064, VP-2122, VP-2241, VP-2421 Power Consumption Applicable Battery Charging Method Charging Current Charging Output Voltage Power Supply Input DC Power Output Control Connector Battery Connection Operating Temperature VX-2000DS Emergency Power Supply 230V AC, 50/60Hz 240W max. YUASA NP series (12V x 2 or 4) Trickle charging 5A max 27.3V ±0.3V (at 25 C) Temperature correction coefficient: 40mV/ C 6 M4 screw terminal, distance between barriers: 11mm 6 (25A max. each) M4 screw terminal, distance between barriers: 11mm RJ45 female connector for connecting the Surveillance Frame. Type of control signal: Battery check, AC power status, DC power status, charging circuit failure, and battery failure 1 pair of positive and negative terminals Applicable cable diameter: AWG 6 AWG 1/0 0 to +40 C Panel: Surface-treated steel plate, black, 30% gloss, paint 482 (W) x 88.4 (H) x 377.6 (D)mm 10.5kg Rack mounting screw x 4, Fiber washer x 4, Blade fuse (40A) x 3, Fuse (T3.15A L) x 1, Power cable x 1

VX-200PS Power Supply Unit VX-2000PF Power Supply Frame The VX-200PS Power Supply Unit is mounted in the VX-2000PF Power Supply Frame when in use. There are 2 DC output channels per unit. Use the VX-200PS in the number suited to the required total system power. The VX-2000PF permits the VX-200PS Power Supply Unit to be mounted in an equipment rack. Up to 3 VX-200PS units can be installed in the unit. VX-200PS 135 333.8 483 465 420 4 6 10 118.2 57.2 324.8 Power Consumption PS OUT Operating Temperature Applicable Frame VX-200PS Power Supply Unit 230V AC, 50/60Hz 580W Rated output: 210W (29V, 7.25A) x 2 Peak output: 400W x 2 M4 screw terminal, distance between barriers: 11mm 0 to +40 C VX-2000PF Surface-treated steel plate 135 (W) x 118.2 (H) x 333.8 (D)mm 13.2kg Fuse (T3.15A L) x 1, Power cable x 1 Product Composition Usable Unit VX-2000PF Power Supply Frame Panel: Surface-treated steel plate, black, 30% gloss, paint 483 (W) x (H) x 324.8 (D)mm 5.5kg Side panel x 2, Chassis x 1, Front panel x 1 Rack mounting screw x 4, Fiber washer x 4 VX-200PS (up to 3)

VX-2000 SERIES BLOCK DIAGRAM RM-200XF + RM-210 s RM-200XF VX-200XR slot 1 VX-200XR slot 2 VX-200XR slot 3 RM-200X + RM-210 s U-01R slot 4 8 Control input (opt-isolated) U-01R slot 5 8 Control input (opt-isolated) RM-200X VX-200XI slot 6 slot 7 8 Control output (opt-isolated) slot 8 8 Control output (opt-isolated) BGM Sources EV-200 Chime EV slot 1 EV slot 2 Monitor speaker (8ohms) Monitor output PM-660U VX-2000 Standby amplifier VP-2241 or VP-2421 + VP-200VX VP-2064 + 4* VP-200VX 100V Speaker lines slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 Optional EQ card VX-200SZ Impedance monitor Optional EQ card VX-200SZ Impedance monitor Optional EQ card VX-200SZ Impedance monitor Optional EQ card VX-200SZ Impedance monitor Optional EQ card VX-200SP Pilot tone monitor Optional EQ card VX-200SP Pilot tone monitor Optional EQ card VX-200SP Pilot tone monitor VP-2122 + 2* VP-200VX slot 8 None or VX-200SE (9-band GEQ card ) slot 9 slot 10 VX-200SI VX-200SO 8 Control input (opt-isolated) 8 Control input (opt-isolated) 8 Control output (dry contact) 8 Control output (dry contact) VP-2241 or VP-2421 + VP-200VX To the next (5 Surveillance frames in total)

VX-2000 SERIES Installation Example of the Hotel INSTALLATION EXAMPLE The location is a hotel where Building A is linked with Building B. Building A was built earlier, and Building B added later. The original public address system was expanded by adding a to cover Building B. Building A Building B Building A 6F Corridor Staff area Stairs 6F Guest rooms 5F Corridor 5F Guest rooms 4F Corridor 4F Guest rooms 3F Corridor Building B 3F Corridor 3F Guest rooms Staff area Stairs 3F Guest rooms 2F Corridor 2F Corridor 2F Guest rooms 2F Guest rooms 1F Conference room 1F Hallway VM Amp. 1F Conference room 1F Hallway Security room VX-2000 Amp. Bar Restaurant Fireman's Microphone GF Lobby Reception Entrance GF Staff area Staff area Amp. GF Lobby Installation Example of the School School Gymnasium Work shop School 2F Corridor Football field 2F Class rooms Stairs PA room Gymnasium Work shop 1F Corridor Fireman's microphone VX-2000 Amplifier Teachers' room Entrance 1F Class rooms VM-2120 The EV-200 can be set to broadcast chimes, programmed announcements, etc. at regular daily intervals using the software timer. Output from the local powered mixer used in the gymnasium can be interrupted by broadcasts from the VX-2000 when an urgent call is made. The Remote Microphones installed in the teachers room and the Staff area can make individual zone calls to other buildings. System failure modes can also be indicated on RM-200X + RM-210 x 2. In the gymnasium, the local VM-2120 amplifier is installed. Broadcast is switched from the local VM-2120 amplifier operation to the central VX-2000 system operation by the VX-200SZ s external attenuator control signals. Football field

VX-2000 SERIES Installation Example of the Department Store INSTALLATION EXAMPLE The key factor in this system application is simultaneous broadcast. BGM sound is broadcast from CD player. Pre-recorded messages are played back to any zones you had set, when software timer activates the EV-200. 3F 2F 1F GF Staff area 3F Escalator Escalator Staff area 2F Escalator Escalator Staff area 1F Escalator Escalator Security room VX-2000 Amplifier Escalator Reception Escalator Fireman's Microphone GF OPTIONS EV-350R Digital Announcer LCD-displayed operation guides and handy selection dial facilitate recording and playback. Holds up to two memory cards. The combination of two sampling frequencies (32 khz and 44.1 khz) and four recording grades ("Long", "Normal", "High" and "Extremely High") permits selection of up to eight levels of recording sound quality to best suit a given situation. Recorded sentences can be combined into complete messages and played back as a program. Up to 256 programs can be played back. Up to 256 or 1,024 sentences (changeable) can be recorded (when two memory cards are installed). Two different messages can be simultaneously output to two different locations. In emergency situations, emergency messages can be set to override current programs. (Emergency messages must be pre-recorded.) Recording, playback, erasure, and stop can be remotely controlled by external equipment. Detachable front cover protects the memory cards from tampering. IT-450 Line Transformer Required by an audio line signal when the distance between the VX-2000 and needs to be extended. Each input requires one IT-450 transformer to be installed in order for it to be isolated. Impedance: 600Ω ±10% : 200 10,000Hz * Optional adapter required for CompactFlash* card recording/playback using the EV-350R. TOA Corporation URL : http://www.toa.jp/ Specifications are subject to change without notice. Printed in Japan (0412) 833-52-291-9B U