LED Driver DC-String

Similar documents
LED Driver DC-String

LED Driver DC-String

LED Driver DC-String

LED Driver Linear / area dimming

LED Driver Linear / area dimming

LED Driver Linear / area dimming

PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

LED Driver Linear / area dimming

LED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series

LED Driver Linear / area dimming

LED Driver Constant voltage. Driver LC 35W 24V SC SNC essence series

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED converter Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

LED Driver Compact dimming

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

net4more IP connected lighting system net4more Driver net4more driver DC 30W mA un:c LED Driver for net4more systems

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Constant voltage. Udriver LCU 100/96W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Constant voltage. Udriver LCU 180W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED power supplies Constant voltage. Uconverter LCU 180W 12/24V IP67 TOP Outdoor IP67 series

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED light engines ready2apply

PHASED OUT. LED light engines ready2apply. Engine SLA ready2apply phase-cut SNC Engine SLA ESSENCE

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics

FL ballasts Electronic fixed output. PC T5 PRO-M lp, W PC PRO-M (T5) Ø 4.1. Ordering data

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

Product data sheet: OTi DALI 25/ /700 LT2 G2

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics

Engineered for Best Fixture Performance. Product features. Certificates and standards. 5 year warranty. Classifications. Engineered for Performance

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

LED Driver LCA PRE, LC EXC Product Manual

Withstands max. 320 VAC (max. 1 hour) *) Low frequency, LED load: Cree XP-G L LEDs. 350 ma 600 ma Fixed output 850 ma P Rated

basicdim Wireless Wireless module for basicdim

LEDlight 20W Universal dimmable series

LED Driver LCA PRE OTD Product Manual

AC modules LED linear / area. Engine LLE AC G1 24mm SNC Module LLE ESSENCE

OTi DALI 75/ /700 D LT2 UF L

L05025 LED Driver 30W, DALI, 7-43 Vdc, mA L05040 LED Driver 40W, DALI, 7-55 Vdc, mA L1A1MID100S-30E L1A1MID100S-40E

LEDLight 20 W Wide voltage series

AC modules LED compact

LC35SE-CC LOOP

LC51SE-CC LOOP

CC COMPACT DIP SWITCH

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

Emergency lighting units PC COMBO

LEDlight 12 W Mini series

LEDLight 20 W Wide voltage series

L CV1050 Constant Voltage LED Driver, 24Vdc, 25W L1K1MID024V-25E

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE. uengine STARK DLE PREMIUM system

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

L LED Driver 40W, 60Vdc, 1050mA, Dimmable L1M1MLT105S-40E L ND LED Driver 40W, 60Vdc, 1050mA L1MLT105S-40E

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

Xitanium LED drivers spot- and downlight SELV Xitanium 17W LH 0.3-1A 24V I 230V

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

L05065 LED Driver 150W, 24-60Vdc, mA L1M1MLT400S-150E

LED DRIVERS. CLi10/CLi15 (10/15 watt) DALI/Touch/Corridor Dimmable

COMPACT LED CONVERTERS 48 V

CV Power supplies with DALI

LED light engine / OLED LED compact

Transcription:

Driver LCU 150W DC-STR DIM SR Dimming Product description Independent dimmable constant voltage LED Driver Compatible with other components Integrated DALI to DC powerline communication bridge (PLC) one4all interface (corridorfunction, switchdim, DALI, DSI) Max. output power 150 W Up to 93 % efficiency Nominal life-time up to 50,000 h For luminaires of protection class I and protection class II 5-year guarantee Housing properties Casing: polycarbonate, white Type of protection IP20 Functions compatible Intelligent Temperature Guard (overtemperature protection) Short-circuit protection Overload protection È Standards, page 3 www.tridonic.com 1

Driver LCU 150W DC-STR DIM SR Dimming Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V DC voltage range 176 280 V Mains frequency 0 / 50 / 60 Hz Typ. current (at 230 V, 50 Hz, full load) 710 ma Typ. current (220 V, 0 Hz, full load) 740 ma Leakage current (at 230 V, 50 Hz, full load) < 500 µa Max. power 162 W Typ. efficiency (at 230 V / 50 Hz / full load) 92.9 % λ (at 230 V, 50 Hz, full load) 0.99 Typ. current in no-load operation 56.3 ma Typ. power in no-load operation 4.3 W In-rush current (peak / duration) 67.1 A / 173 μs THD (at 230 V, 50 Hz, full load) < 5 % Output voltage tolerance -1... +5 % Output LF current ripple (< 120 Hz) ± 1 % Max. output voltage (no-load voltage) 50.5 V Max. cable length secondary See section 3.5 Mains surge capability (between L N) 1 kv Mains surge capability (between L/N PE) 2 kv Surge voltage at output side (against PE) < 450 V Ambient temperature ta -25... +50 C Max. casing temperature tc 80 C Dimensions L x W x H 235 x 100 x 31 mm Ordering data Type 164 235 tc Article number 31 Ø4.2 5 70 100 Packaging carton Packaging pallet Weight per pc. LCU 150W DC-STR DIM SR 28001044 10 pc(s). 300 pc(s). 0.369 kg We recommended using following LMI LED Drivers together with this LCU DC power supply: Type Article number Packaging box Packaging carton Packaging (contains 10 boxes) pallet Ø104 Weight per pc. LMI G2 350-700mA 3-20V DIM slim 28000731 5 pc(s). 50 pc(s). 3,000 pc(s). 0.013 kg LMI G2 700-1050mA 3-20V DIM slim 28001583 5 pc(s). 50 pc(s). 3,000 pc(s). 0.016 kg LMI G2 350-700mA 20-42V DIM regular 28001584 5 pc(s). 50 pc(s). 3,000 pc(s). 0.012 kg LMI G2 350-700mA 20-42V DIM slim 28001585 5 pc(s). 50 pc(s). 3,000 pc(s). 0.013 kg www.tridonic.com 2

1. Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 62384 EN 61547 EN 62386-101 (according to DALI standard V2) 2. Thermal details and life-time 2.1 Expected life-time Expected life-time ta 40 C 50 C 55 C Type tc 70 C 75 C 80 C Load 95,000 h 70,000 h 55,000 h 100 % LCU 150W DC-STR DIM SR Life-time 180,000 h 140,000 h 100,000 h 75 % 300,000 h 230,000 h 170,000 h 50 % 450,000 h 340,000 h 250,000 h 25 % The LED control gear is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. The relation of tc to ta temperature depends also on the luminaire design. If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request. 3. Installation / wiring 3.1 Circuit diagram 220 240 V 0/50/60 Hz L N 3.2 Mains supply wiring Stranded wire or solid wire up to 2.5 mm 2 may be used for wiring. Strip 10 11 mm of insulation from the cables to ensure perfect operation of the push terminals. Use one wire for each terminal connector only. Use each strain relief channel for one cable only. DALI/DSI + DA/N LCU DC-STR DIM DA/L PRI 48 V max. = 9 mm min. = 4,5 mm 10,5 10,5 0,5 2,5 220 240 V 0/50/60 Hz L N 3.3 Output wiring (48 V bus) The output wiring can be done with a cross section of 0.2 2.5 mm². Strip 9 10 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. N L switchdim 220 240 V 50/60 Hz DA/N DA/L PRI 48 V + LCU DC-STR DIM wire preparation: 0.2 2.5 mm² 9 10 mm Use one wire for each terminal connector only. Use each strain relief channel for one cable only. www.tridonic.com 3

3.4 Loose wiring Input terminal Output terminal 4. Electrical values 4.1 Efficiency vs. load 95 90 Efficiency [%] 85 80 3.5 Wiring guidelines The 48 V cables should be run separately from the mains connections and mains cables to ensure good EMC conditions. The 48 V DC output wiring should be kept as short as possible to ensure good EMC. The max. secondary cable length is 30 m (60 m circuit) till beginning of a grounded metal track light. If track light is not grounded or made of plastic, cable length including track light is 30 m. Inside the track light cable length is limited by voltage drop that last in the track light is still supplied with minimum 46 V. Secondary switching is not permitted. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). 3.6 Hot plug-in Hot plug-in during operation is supported for one DC/DC-LED Driver (LMI). It is only allowed to connect or disconnet one DC/DC-LED Driver (LMI) at the same moment onto the 48 V bus. Configured parameters of DC/DC-LED Driver (LMI DIM) are not saved if they are unplugged. For saving parameters a mains reset of the DC power supply is necessary. 75 70 Load [W] 4.2 Power factor vs. Load 1,00 0,95 0,90 Power factor 0,85 0,80 0,75 0,70 0,65 0,60 Load [W] 4.3 Input power vs. Load 3.7 Function of the earth terminal q The device has to be earthed to fulfill EMI requirements. Input power [W] 180,7 160,7 140,7 120,7 100,7 80,7 60,7 40,7 20,7 0,7 Load [W] www.tridonic.com 4

4.4 Input current vs. Load 4.5 THD vs. Load 801 35 Input current [ma] 701 601 501 401 301 201 101 THD [%] 30 25 20 15 10 5 1 0 4.6 Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 2.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 2.5 mm 2 I max time LCU 150W DC-STR DIM SR 8 10 13 16 5 6 8 10 59 A 220 μs Calculation uses typical values from ABB series S200 as a reference. Actual values may differ due to used circuit breaker types and installation environment. 4.7 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LCU 150W DC-STR DIM SR 5 5 1 1 1 1 5. Interfaces / communication 4.8 Dimming Dimming range 70 ma to 100 % of nominal current Digital control with: Programmable parameter: Minimum dimming level Maximum dimming level Default minimum = depending on nominal current level Default maximum = 100 % Dimming curve is adapted to the eye sensitiveness. Dimming is realized by amplitude dimming. 4.9 Dimming characteristics Digital dimming value 255 225 200 175 150 125 100 75 50 25 0 0 10 DALI 20 30 DSI 60 70 80 90 100 Relative lighting level % Dimming characteristics as seen by the human eye 40 50 5.1 Control (DA/N, DA/L) Digital DALI signal or switchdim can be wired on the same terminals (DA/N and DA/L). The control is non-polar for digital control signals (DALI, DSI). The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module. 5.2 switchdim Integrated switchdim function allows a direct connection of a pushbutton for dimming and switching. Brief push (< 0.6 s) switches LED control gear ON and OFF. The dimm level is saved at power-down and restored at power-up. When the pushbutton is held, LED modules are dimmed. After repush the LED modules are dimmed in the opposite direction. In installations with LED control gears with different dimming levels or opposite dimming directions (e.g. after a system extension), all LED control gears can be synchronized to 50 % dimming level by a 10 s push. Use of pushbutton with indicator lamp is not permitted. 5.3 PowerLineCommunication (PLC) The communication between the LED control gear and the DC/DC-LED Driver is done over power line. The DALI signal will be modulated by the LED control gear and will be sent over the 48 V DC signal to the DC/DC-LED Driver. 5.4 DC operation The DC power supply is designed for operation on DC voltage and pulsed DC voltage. Behaviour in DC operation mode is the same as in AC operating mode. www.tridonic.com 5

6. Functions 6.1 Short-circuit behaviour In case of a short-circuit at the output the output is switched off. After restart of the DC power supply the output will be activated again. The restart can be done via mains reset. 6.2 No-load operation The DC power supply will not be damaged in no-load operation. 6.3 Overload protection If the output power range is exceeded by more than 10 % the DC power supply gives a blinking signal to the DC/DC-LED Driver. The DC power supply will blink 5 times, after 30 s break, it checks again, if: there is no overload, then the device will go in normal operation. there is still overload, the device will blink again 5 times. 6.4 Overtemperature protection The DC power supply will blink 3 times, after 30 s break, it checks again, if: there is no overtemperature, then the device will go in normal operation. there is still overtemperature, then the device will blink again 3 times. 6.5 corridorfunction Is set in the DC/DC-LED Driver. 6.6 Light level in DC operation Is set in the DC/DC-LED Driver. 6.7 Software / programming 7. Miscellaneous 7.1 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 7.2 Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be acclimatised to the specified temperature range (ta) before they can be operated. 7.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. With appropriate software and a interface different functions can be activated and various parameters can be configured in the LED control gear. To do so, a DALI-USB and the software (masterconfigurator) are required. 6.8 masterconfigurator From version 2.8: For programming functions (power-up fading, corridorfunction) and device settings (fade time, epoweronlevel, DC level, etc.). For further information see masterconfigurator manual. www.tridonic.com 6