MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Similar documents
MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Switched Mode Power Supply Operating manual PAP800

A0750 AC-DC POWER MODULE

PSC600-series DC/DC W

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

INSTALLATION MANUAL SLI 50 INVERTER

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

AC-DC Converter REC K10

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS

SLI 15 INVERTER SERIES, 1500 W

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RT4F-48V/50A-WAC RECTIFIER

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

RT4F-120V/20A-WAC RECTIFIER

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

RT4B-110V/12A RECTIFIER

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

FMP VDC RECTIFIER 42 Amps 2000 Watts

Chameleon Stand-alone

RT4F-110V/25A RECTIFIER

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

MC 11 EB-2 Power supply cabinet with external bus, AC version

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

AC-DC Converter RECE K21

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

TMF SERIES: 1U HOT-SWAP POWER SYSTEM Single Output 400 Watt Modules with PFC

ac wave 2 supply ( analog device )

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

TECHNICAL DESCRIPTION

Industrial Power Supplies

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS

AC-DC Converter REC /60-K20

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

TXP3500/4000 Series AC-DC Industrial PSU

RT12-240V/2.4kW Rectifier Specification

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

HERCULES-5000 INSTRUCTION MANUAL

Industrial Power Supplies

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

GAMATRONIC, A SolarEdge Division.

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

PCU Supervisory module for the RM 1000 series

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Installation and Maintenance

Uninterruptible Power Supplies

Cisco CRS 16-Slot Chassis Power Systems

RECTIFIER PSR327 USER MANUAL. Eltek_UM_PSR327_21TE_E_R6.0

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

the Centric 300 An advanced modular UPS up to 1800kVA/kW

EFE300 / EFE400 EFE300M / EFE400M

H-series (Rectifier Module)

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

Other standard features include current and voltage monitoring, overvoltage, overtemperature as well as short circuit protection.

RT7-48V/6kW Specification

TRC ELECTRONICS, INC

Installation Unit Primary Switched Power Supply 1500 W EXW /OP1 adjustable V/I

UEP10M005 Power Supply User s Manual

Prisma II Platform. Optoelectronics

PowerCassette : 1U HIGH RACK-MOUNT DC/DC CONVERTERS 48VDC to 12 or 24VDC at 700 Watts / 48VDC to 48VDC at 1000 Watts

Chassis Power Supplies

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

PS 2500 SYSTEM IN-BUILT ALARM MONITORING FLEXIBLE ON-LINE LIVE REPLACEMENT HIGH EFFICIENCY HIGH OUTPUT FROM A SMALL PACKAGE

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Series C / B Power Supplies Converters Inverters Rectifiers Chargers Systems. Schaefer the Power to make it happen.

SMARTONLINE E3 UPS SYSTEMS

GUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & Battery -48VDC 500A 26.8kW

24/48V Battery Bank Ah High Cycling Long Life

DC/AC INVERTER. PWS Series USER MANUAL UM_PWS_E_R1.2

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

500Watts Medical Single Output

DeltaV Bulk Power Supplies

Chloride CROSS Rack 16 A, 32 A and 63 A

REGULATED DC POWER SUPPLIES.

EMC1600 Series Media Converter and Ethernet Extender Chassis

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

TRC-190 User s Manual

DeltaV Bulk Power Supplies

RSTI-EP Slice I/O. Digital Output Module

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Magnetically Actuated Safety Interlock Switches

E-Series Site Preparation Guide

General Purpose Chassis for PXI and CompactPCI

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Transcription:

MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules Power supply or battery charging applications Module and mains alarm for remote monitoring Solid construction for heavy duty applications Optional Shut Down and input over voltage disconnection Flexible connections Parallel n+1 connection, up to 90A Series connection, up to 400VDC Multi outputs, ± outputs Connection examples 19 SUB-RACK UNITS Type Voltage Modules Power Mechanics (w x h x d) versions per rack MSR7110/48 24V, 36V, 48V 1 3 pcs 800W 2400W 19 (482mm) / 2U (88mm) / 360mm MSR7110/96 72V, 96V 1 3 pcs 800W 1800W 19 (482mm) / 2U (88mm) / 360mm 8871100C Covering plate set for empty module place 70130753 IEC320 power cord 2.5m, rubber cable RECTIFIER MODULES Type Input voltage *) Nominal Output Voltage Voltage Setting Range Max Output Current Current Limit Setting Max Power Mechanics (w x h x d) ADC7180/24 55-264VAC/78-360VDC 24 VDC 0-36VDC 30 A 0-30A 800W 25TE / 2U / 230mm ADC7180/36 55-264VAC/78-360VDC 36 VDC 0-54VDC 20 A 0-20A 800W 25TE / 2U / 230mm ADC7180/48 55-264VAC/78-360VDC 48 VDC 0-72VDC 15 A 0-15A 800W 25TE / 2U / 230mm ADC7180/72 55-264VAC/78-360VDC 72 VDC 0-108VDC 10 A 0-10A 800W 25TE / 2U / 230mm ADC7180/96 55-264VAC/78-360VDC 96 VDC 0-144VDC 7.5A 0-7.5A 800W 25TE / 2U / 230mm *) Max power 600W at DC input Reduced power 55 200VAC or 78 200VDC Sales & R&D Martinkyläntie 43, FI-01720 VANTAA, Tel. +358 10 2890 700 Fax +358 10 2890 793 Production and Service Teollisuuskatu 3, FI-44150 ÄÄNEKOSKI, Tel. +358 10 2890 700 Fax +358 10 2890 790 E-mail marketing@powernet.fi, service@powernet.fi Internet www.powernet.fi

INPUT Input voltage 55 264 VAC 55 200VAC reduced power, see module datasheet 78 360 VDC / max 600W 78 200VDC reduced power, see module datasheet Frequency 45...65Hz Safety According to EN60950, Class I Input current Max 4.5A per module Inrush current Soft start max 7A 10ms peak, otherwise less than 4.5A Isolation Input / ground 1500VAC Input / outputs 3750VAC Output / ground 500VDC Mains switch Front panel with light 12, 24, 48VDC One per PSU 72, 96VDC One per sub-rack, max 10A current Mains input connector Common input for each rectifier IEC320 C14 male connector OUTPUT Voltage Nominal voltages 0 144VDC / max 800W per module Current Nominal current per module 0 30A / max 800W per module Short circuit protection Rectifier modules Short circuit protected, electronic current limit MCBs on front panel ADC7110/48 sub-rack 3 x 30A MCB in negative output ADC7110/96 sub-rack 3 x 10A MCB in negative output Output connector 3 terminal groups on rear panel 3-pole 10mm 2 screw terminal for each rectifier (+, -, PE) Hot swap Series diode in each rectifier Hot-swap allowed, Input and output switch at OFF position Series/parallel operations All modules can be connected in series or in parallel CONTROLS Input On the front panel Power switch with ON/OFF light Output On the front panel MCB ON/OFF safety switch ALARMS Input failure U in nom < appr. 150VAC Normally open and closed relay contacts Output failure Module failure or output switch off Relay contact and MCB auxiliary relay Alarm connector Rear panel Removable 12-pole 2.5mm 2 screw terminal Pin configurations 1 Mains alarm COMMON 2 Mains alarm NO 3 Mains alarm NC 4 Parallel output alarm COMMON 5 Parallel output alarm NO *) 6 Series output alarm PSU1 COMMON 7 Series output alarm PSU1 NC *) 8 Series output alarm PSU2 COMMON 9 Series output alarm PSU2 NC *) 10 Series output alarm PSU3 COMMON 11 Series output alarm PSU3 NC *) 12 Not in use *) Normally = Mains / PSU OK MECHANICAL Power Rack 19 sub-rack Positions for 3 pcs of ADC7180 euro modules Dimensions Height 2U (88mm) Width 19 (482mm) Depth 360mm Weight Rack without rectifiers 5.5 kg Rectifier 1.35kg Enclosure Steel IP20 ENVIRONMENTAL Temperature range Operating -25 C...+50 C (full power typically) +50 C...+70 C (derating) Storage -40 C...+85 C Cooling Temperature controlled fan Front panel, air flow front to rear Grounding M6 screw On the rear panel

Operating and connecting the sub-rack and modules General MSR7110 sub-racks can be used to supply several output voltages from 0V up to 400VDC in series connection. Modules can be connected in parallel, series or to have multi output voltages from the same sub-rack. Units are hot swappable, but the sub-rack also have both input and output switch to make the change without power. 1 3 pcs of modules can be installed in the sub-rack. Empty module places are covered by the cover plate. Mounting the sub-rack Sub-rack is installed in 19 cabinet and mounted by 4pcs of M6 screws from the front panel. Mounting the plug-in module The plug-in module is installed by pushing it to the bottom of sub-rack as long as the connector in the rear panel have the contact with the mating connector in sub-rack. Mounting screws in modules front panel are fastened. Removing the module is made in opposite order. Mains connection The mains is supplied by IEC320 C14 male connector. Use 1-phase power cords cross-section 3 x 1,5mm 2. The minimum mains fuse is 16A. Make sure that both input and output are switched off in the front panel of sub-rack before connecting the mains. Turn the mains switch to up position. The switch light indicates that mains is connected. The unit is starting about 4 seconds. The unit s output led in front panel is lightning green. Output connection Use minimum 4mm 2 output cable, 6mm 2 preferred. Connect cables to the screw terminal in the sub-rack s rear panel via the cable clamp. Output MCBs can be turned to the ON position after module s output led in front panel is green. Outputs can be in stand-alone, parallel or series use. 1. Stand alone use Connect minimum 4mm 2 cables from modules + and - screw terminal to load. 2. Parallel use Connect each module to the load by minimum 4mm 2 cables. To ensure proper load sharing the length and cross section of each output cable need to be the same and the output adjustment at each module should be equal. 3. Series use The series connection is made by connecting the positive output of module 1 to the negative output of module 2 and connecting the load between the positive output of module 2 and negative output of module 1. Use minimum 4mm 2 cables. Output voltage adjustment The factory setting for the output is the nominal voltage (for example 48VDC). Output of each module can be adjusted by turning Uadj trimmer. The adjustment is made by small screw driver. Output current limit adjustment The factory setting for the current limit is the nominal output current. Output current limit (max current) can be adjusted from the Iadj trimmer. Alarms Potential free change over relay contacts (NO, NC, COM) are included in system. Input alarm Input alarm is indicated when mains reduce below 150V. Both normally open contact between pins 1-2 and normally closed contact between pins 1-3 are available.

Module fail or output MCB fail Each rectifier have module fail relay alarm NO and NC contact. Standard sub-rack includes NC contacts from each rectifier and parallel connected common alarm from whole system with NO contacts. Parallel connected NO contacts are in use when switch S4 is in NO position. Common alarm can be now connected between pins 4-5. If the switch S4 is in NC-position (serial alarm), output alarms of each PSU can be used individually from pins 6-7, 8-9 and 10-11 or to these individual alarms can be connected in series and the common NC output can be taken out between pins 6 11. The status normal means the normal operating condition for the power supply. The cross section of alarm cable can be 0,22 0,75mm2. Electrical connections in the sub-rack Voltage versions 12VDC, 24VDC and 48VDC

Electrical connections in the sub-rack Voltage versions 72VDC and 96VDC Pin Configuration in rear panel Lead through position for analog control cable