Environdata FA ma Converter Guide

Similar documents
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

PSM-2 POWER SUPPLY MODULE INSTRUCTIONS

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

DC562, digital input/output module,

the Interactive Catalog

DI561 Digital Input Module

PCI-FPGA-1B User Guide

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

DX561 Digital Input/Output Module

Model 305e OEM CO 2 concentration sensor

MC300. BLN Issued: April 2003

DI572 Digital Input Module

TCNM-ACBB1 Installation Manual

GSV-1A4 M12/2 M12/2. Highlights

HD B. [ GB ] Precision Barometer

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

RPS-401A, RPS-426A Self-Contained Ultrasonic Sensor

4 Channel DMX Driver Instruction Manual

Expansion Module HZS 541-1S

IIM Warwick Court. Williamsburg VA REV 5

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

9823 Multifunction Calibrator Calibration Adjustment Procedure

EZ-24 EZ-24-HTB EZ-24-HTBS. Version May Publication PR-1100

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

SDG1400 User s Guide

DC561, digital input/output module,

TECHNICAL PRODUCT DATASHEET

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

AI561 Analog Input Module

Accsense Wireless System. Temperature Monitor

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

Installing Sentor. Hardware Installation

TB6600 Stepper Motor Driver User Guide

Sensacell Troubleshooting Guide

T2214. Instruction Manual

I/O EXPANSION MODULES

TOXALERT MODEL AIR 2000

Hybrid AC Driver [GCNC-1110]

HL20-A Measurement and Control System

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

VersaMax IP I/O Module

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

Moxa TCC-100 Series User s Guide

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

Differential Liquid/Gas Pressure Transmitter

GFK-2415A March Type of sensor connection

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Adapter Kit - Remote QSI Electronics Installation Instructions

Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) A Visionary Awning Control by

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

VersaMax IP Input Module

Light & Sound Control Module

Installation Instructions Temperature transmitter TAA /00 06/2011

TRANSDUCER T4311, T4411

ARABLE BRIDGE QUICK START GUIDE

T2314, T2414. Instruction Manual

FLOW MONITOR & TRANSMITTER

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232

AO561 Analog Output Module

E101 - Strain Gauge Transducer Display Module. Contents

T2314, T2414. Instruction Manual

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

LVX Control Unit. Features:

AC-43 Accelerometer. User Manual

TB6600 Stepper Motor Driver

USER MANUAL FOR FIOA-0402-U-16

MODEL SIB-V245 / V453

icex-cmtm General specs and Installation guide

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

JVA SMS Gateway User Manual

Building Technologies. FDCIO181-1 Input/Output Module Product Manual. Characteristic. Application Input

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Installation Instructions

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

OPERATION MANUAL MODEL TT-LP

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Tempco Instruction Manual

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE

Buffered Power Supply PS-30DR v1.0

Manual Control Unit GFC 32

Transcription:

FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA, 4370 Phone: (07) 4661 4699 Intl: +61 7 4661 4699 Fax: (07) 4661 2485 Intl: +61 7 4661 2485 No reproduction without the prior permission of the publisher.

Introduction This handbook covers the installation and operation of 's FA12 frequency to current converters. NOTE Each frequency to current converter is factory calibrated and can then be individually set to a specific sensor type by adjusting DIP switch settings within the FA12. Your FA12 is configured for your sensor during final testing just prior to shipping. If you have several different sensors and converters, please ensure that each sensor is connected to the correct converter. Principle of operation The frequency to current converter measures the frequency of the incoming signal (digital pulse train), and then converts this to an analog output current proportional to the input frequency. Limitations The FA12 series of converters need to operate using a 3 wire system, such that the output wire is separate from the power supply wires. Both the Ground wire (GND) and the 4-20 ma Output (Output) must be connected for the device to operate correctly. Protection The FA12 series of converters have been protected from reverse polarity connection (applies to Hardware version 3.5 and later).

Typical 3 wire Connection Diagram 4-20mA Connection Diagram for PLC or SCADA system Power Supply from PLC/SCADA system +12-24VDC To V+ PLC/SCADA system Sensor FA12 4-20mA Converter Out Current Gnd 0V The FA12 4-20mA converter needs +Power, a GND path and the signal line connected. When connecting to a PLC or SCADA system, you must connect the signal out through the PLC and back via the 0V connection.

Installation The frequency to current converter should be connected between the output of an sensor and your equipment that requires a current signal. As both current and sensors signals are capable of being run over long cables, you are free to mount the FA12 in a position that is convenient for your installation. Physical mounting of the FA12 can be done by using the two mounting holes identified in the image below. You are required to remove the plastic lid (remove the 4 screws) to access the mounting holes. After locating the FA12 in a suitable position, connect the sensor to the 3 pin connector located on the FA12. Connect a 3 wire cable to the FA12 taking note of the wiring details in the following section. The FA12 uses a terminal strip located inside the FA12 converter housing for connection of the wires. Please tighten the cable gland and ensure a tight seal is formed once you have inserted your cable. This will need checking and re-tightening after 14 days and at your regular site visits. Please see the markings inside the converter for connection of the three wires (FA12 is indicated in the image below). As there are many and varied devices that require a current signal, we are unable to provide information on how to connect the FA12 to your particular equipment. Please consult your equipment's handbook for wiring details.

Sensor Configuration The FA12 can be configured for various sensor types by changing the DIP switch setting and the MODE jumper. Currently the MODE jumper is not implemented and must be set to Mode A or the FA12 will not operate correctly. (The mode jumper will provide for an additional 16 sensor types in the future). Please confirm your sensor type and DIP switch setting from this list. The label in the LID of your converter may be out of date, if unsure check with. The list below is the most recent list at the time of printing this handbook and should be similar. NOTE that a new setting will ONLY take effect after the power is turned OFF and ON again. THIS list applies to applies to Firmware version 3.4, 24th April 2013 & Later Sensor Type Signal input - output Dip Switch Setting (Yellow is switch Position) RH40 Relative Humidity (0-100%) 10-20Hz = 4-20mA SR10 Solar Radiation (0-2000 W/m2) RH21 Humidity (0-100%) 0-10Hz = 4-20mA WS30 Wind speed (0-60Kph) WS40, WS45 Wind speed (0-71Kph) 0-20Hz = 4-20mA PR10 PAR Sensor WS30 Wind speed (0-90Kph) WS40, WS45 Wind speed (0-106Kph) 0-30Hz = 4-20mA TA10, TA40, TA60, TS10, TS40, TS60, TG10, TG40, TG60 Temperature sensors (-20 to +60) 0-40Hz = 4-20mA WS30 Wind speed (0-120Kph) WS40, WS45 Wind speed (0-142Kph) SR41 Solar Radiation (0-2000 Watts / metre Squared) 10-50Hz = 4-20mA WS30 Wind speed (0-180Kph) WS40, WS45 Wind speed (0-213Kph) 0-60Hz = 4-20mA WD32, WD42, WD45 Wind Direction 0-90Hz = 4-20mA

Sensor Type Signal input - output Dip Switch Setting (Yellow is switch Position) BP40 Barometric Pressure (800 to 1100 hpa) 10-70Hz = 4-20mA BP10 Barometric Pressure (900-1050 hpa) 17.5-19.75Hz = 4-20mA NR40 Net Radiometer (-500 to +1500 Watts/metre squared) 10-30Hz = 4-20mA SM40 Echo Soil Moisture 10-40Hz = 4-20mA LW10, LW12 Leaf Wetness 7.7-18Hz = 4-20mA Test Mode - half signal 12 ma Test mode Test Mode - Zero signal 4 ma Test mode Test Mode - Full Signal 20 ma Test mode Selecting a DIP switch setting that is not valid or changing the MODE to "B" will result in a default setting of 10-20Hz = 4-20mA.

Operation When power is first applied to the FA12, the status LED will flash the number of times the DIP switch is set to. This is useful to confirm that your switch setting is correct. During this time, the FA12 will output 4mA. Once the flash sequence has completed, it will then measure the incoming frequency from the connected sensor and adjust its output current to match. The normal response time is less than a few seconds. If the sensor is disconnected at any time during normal operation, causing an unexpected stop of pulses, the output of the FA12 may take up to five seconds to return to the correct value of 4mA. Independent Test Circuit If you want to test the FA12 and its sensor independently of your system, you can use the circuit below. Independent Test Diagram Power Supply from PLC/SCADA system +12-24VDC To V+ Sensor FA12 4-20mA Converter To Out ma Multimeter To Gnd 0V Connect a multimeter on its current setting and check the current values are as per the expected setup. (See Table1 in handbook).

FAQ (Frequently Asked Questions) Q. Why are three wires needed? A. The third wire is used to power the connected sensor, and the FA12 regulates this voltage to the correct level to power the sensor. Q. If my FA12 is calibrated for a WS30 wind speed sensor for 20mA at 120kph, what happens if the wind speed goes higher than 120kph? A. The FA12 output will NOT continue to increase past 20mA. In this situation if you require the ability to measure a higher wind speed, check the DIP switch settings to see if a different range is available for your sensor (ie. WS30: 0-180kph = 4-20mA) Q. Should the FA12 be mounted near the sensor? A. 1:When there is less than 20m cable run between the sensor and your PLC / Data recorder, and no environmental interference: Both 4-20mA and sensor signals can be run on medium length cables. You may mount the FA12 where it is most convenient for your installation. A. 2: For longer cable runs between the sensor and your PLC / data recorder (20+ metres or when there is potential of interference from the environment): The sensor signal is able to be run for several hundred metres with no signal loss and is highly resistant to any interference. Therefore it is recommended you run extension cables from our sensors to your PLC / DR location and connect your FA12 s close to the PLC /DR in this situation. Q. My FA12 works correctly in all three Test modes, but appears unstable when I connect a sensor with the normal modes. Why is that? A. The most likely problem is that either the ground wire (GND) is not connected back to the zero volts of the supply or the 4-20 ma output (OUTPUT) is not drawing current. The latter could be because the 4-20 ma shunt converting the PLC/SCADA Input from voltage to current has not been set / inserted OR an Isolated analog input is being used and the link from Analog minus to Power Supply zero volts has not been connected.

Connection Hints Where your PLC does not have a dedicated 4-20 ma input, an analogue voltage input can be used. Using the FA12 with a Voltage input on the PLC. (Analogue Voltage Input) Power Supply +12-24VDC from V+ PLC/SCADA system Out PLC/SCADA Sensor FA12 4-20mA Converter 250 Ohm shunt V Gnd PLC Voltage input 0V The FA12 can be connected to a Voltage input on a PLC. To do this, connect a 250 Ohm resistor across the Out and Gnd pins of the FA12. This will give a 1 to 5V signal range for 4 to 20 ma into the PLC. Some PLC systems have a switch or jumper selection that provides the connection to the 250 ohm resistor internally as part of the setup instructions. A 100 ohm shut can also be used, giving 0.4 volts to 2.0 volts for the 4 to 20 ma range. Isolated 4 20 ma Inputs If you are using an isolated input, it will be necessary to connect the analogue input negative terminal to the zero volts with a link. This link provides the return path for the output signal.

Sensor Connection Provided for reference Sensor connection The FA12 series of converters use a 3 pin weather proof connector for connecting the sensor. The wiring detail is as follows: A = Power +6 to +7 volts DC (Red) [nominal 6.25V DC] B = Sensor signal (Blue) C = 0V Ground (Green) This is the view of the sensor connector mounted on the FA12 converter.