AT-GS950/16 AT-GS950/24

Similar documents
Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

Layer 2 Fast Ethernet Switch AT-FS708/POE. Installation Guide Rev. C

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

AT-x200-GE-52T Gigabit Ethernet Switch with 4SFP Ports. Installation Guide Rev. A

AT-9000 Managed Layer 2 GE ecoswitch Series AT-9000/28 AT-9000/28SP AT-9000/52. Installation Guide Rev. A

Stack Installation Guide

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

Installation Guide. AT-9400 Series Gigabit Ethernet Switches AT-9424T/GB AT-9424T/SP. AT-9424T/POE AT-9424Ts AT-9424Ts/XP AT-9448T/SP AT-9448Ts/XP

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

Stand-alone Switch Installation Guide. 8100L and 8100S Series Fast Ethernet Switches

D-Link Switch User Manual. Table of Contents

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

x600 Series Layer 3 Gigabit Ethernet Switches x600-24ts x600-24ts/xp x600-48ts x600-48ts/xp x600-24ts-poe Installation Guide Rev.

Installation Guide. AT-IX5-28GPX Gigabit Ethernet Switch C REV B IX5-28GPX SFP+ S1/27 CONSOLE S2/28 FDX HDX COL

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

x550 Series Installation Guide for Virtual Chassis Stacking Stackable 10Gigabit Intelligent Access Ethernet Switches AlliedWare Plus v5.4.

Installation Guide. x600 Series Layer 3 Gigabit Ethernet Switches. x600-24ts x600-24ts/xp x600-48ts x600-48ts/xp x600-24ts-poe x600-24ts-poe+

48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800. User Manual

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

24-Port Gigabit Ethernet Switches

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

x550 Series Installation Guide for Virtual Chassis Stacking Stackable 10Gigabit Intelligent Access Ethernet Switches AlliedWare Plus v5.4.

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

x550 Series Installation Guide for Stand-alone Switches Stackable 10Gigabit Intelligent Access Ethernet Switches AlliedWare Plus v5.4.

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

USER GUIDE. EZ Switch TM 10/100 16/24-Port Unmanaged Fast Ethernet Switches SMCFS1601/SMCFS2401

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Perle MCR200 Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

GEU-0520 GEU QIG Manual

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

Installation Job Aid for Ethernet Routing Switch 3600 Series

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

ST-POEAF-S16-RM. 16 port PoE switch. User Guide

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

Management Software AT-S67 AT-S68. User s Guide FOR USE WITH AT-FS7016 AND AT-FS7024 SMART SWITCHES VERSION PN Rev A

Ether-FSH2400C 24-port 10/100Base-TX Switch

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

AT-SBx908 Gen2 Switch

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

AT-S79 Version ( ) Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

AT-S79 Version Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

USER GUIDE. EZ Switch TM 10/100/ G Port Unmanaged Fast Ethernet Switch SMCFS2601

H3C S1016/1024 Ethernet Switch User Manual

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

25 SFP+ AT-x530-28GPXm PORTS PORTS G LINK PD ON PD ERR MAX CURRENT 5G/2.5G/1G/100 ACT 100 LINK ACT 5G/2.5G/1G LINK ACT 100 LINK ACT

Modular 8-Port Mid-span Power over Ethernet Injector

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Enclosure TS-530 User Manual

FCC Certifications. CE Mark Warning

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Raven Series Standalone Media Converters

FSW-1609TFX FSW-2409TFX

FSW-1610TX FSW-2410TX

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

NETGEAR, Inc Great America Parkway Santa Clara, CA USA. April 2004

2 Mesa Ethernet Dock User s Manual

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

CSM200 Expansion Tray

KFC-200. Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

LNX-0702G-SFP Series

24-Port 10/100Mbps + 2-Port. Gigabit Ethernet Switch FGSW User s Manual

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Switch manual Models &

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

FRG-3105 Series Residential Gateway

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

100 - SERIES NETWORK SWITCHES Installation Manual

Giga-MiniMc TX & RX USER MANUAL

Quick Start Guide. C-100 Series Switches

Getting Started: Smart Ringswitch Family

HES-3106-PLUS SERIES

Gigabit Ethernet Media Converter

4170 POS System Installation Guide

Transcription:

Gigabit Ethernet Smart Switches AT-GS950/16 AT-GS950/24 Installation Guide 613-000190 Rev. B

Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.

Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment. Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, C-TICK, CE Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Immunity EN55024 Electrical Safety EN60950 (TUV), UL 60950 ( C UL US ) Laser Safety EN60825 3

Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements (613-000405) posted on the Allied Telesis website at www.alliedtelesis.com. 4

Contents Preface...11 Safety Symbols Used in this Document...12 Where to Find Web-based Guides...13 Contacting Allied Telesis...14 Online Support...14 Email and Telephone Support...14 Returning Products...14 Sales or Corporate Information...14 Warranty...14 Management Software Updates...14 Chapter 1: Overview...15 Features...16 Front and Back Panels...17 Ports...18 Twisted Pair Ports...18 Uplink Combo Ports...18 RS-232 Console Port...18 LEDs...19 Power Supply...21 Network Topologies...22 Power Workgroup Topology...22 Collapsed Backbone...23 Chapter 2: Installation...25 Reviewing Safety Precautions...26 Selecting a Site for the Switch...28 Cable Specifications...29 Unpacking the Switch...30 Installing the Switch on a Desktop...31 Installing the Switch in an Equipment Rack...32 Installing an Optional SFP Transceiver...34 Cabling the Switch...37 Powering On the Switch...38 Chapter 3: Troubleshooting...39 Appendix A: Technical Specifications...41 Physical Specifications...41 Environmental Specifications...41 Power Specifications...41 Safety and Electromagnetic Emissions Certifications...42 Connectors and Port Pinouts...42 5

Contents 6

Figures Figure 1. AT-GS950/16 and AT-GS950/24 Front Panels...17 Figure 2. AT-GS950/16 and AT-GS950/24 Back Panels...17 Figure 3. AT-GS950/16 and AT-GS950/24 System and Port LEDs...19 Figure 4. Power Workgroup Topology...22 Figure 5. Collapsed Backbone Topology...23 Figure 6. Attaching the Rubber Feet...31 Figure 7. Attaching the Rack-Mount Bracket to the AT-GS950/16 Switch...32 Figure 8. Attaching the Rack-Mount Bracket to the AT-GS950/24 Switch...32 Figure 9. Mounting the AT-GS950/16 Switch in an Equipment Rack...33 Figure 10. Mounting the AT-GS950/24 Switch in an Equipment Rack...33 Figure 11. Removing the Dust Plug from the SFP Slot...34 Figure 12. Inserting the SFP...35 Figure 13. Positioning the SFP Handle in the Upright Position...35 Figure 14. Plugging in the AC Power Cord...38 Figure 15. RJ-45 Connector and Port Pin Layout...42 7

Figures 8

Tables Table 1. Safety Symbols...12 Table 2. System LEDs...19 Table 3. 10/100/1000Base-T Port LEDs...19 Table 4. SFP Port LEDs...20 Table 5. Twisted Pair Cabling and Distances...29 Table 6. MDI Pin Signals (10Base-T or 100Base-TX)...42 Table 7. MDI-X Pin Signals (10Base-T or 100Base-TX)...43 Table 8. RJ-45 1000Base-T Connector Pinouts...43 9

Tables 10

Preface This guide contains installation instructions for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches. This preface contains the following sections: Safety Symbols Used in this Document on page 12 Where to Find Web-based Guides on page 13 Contacting Allied Telesis on page 14 11

Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Warning Performing or omitting a specific action may result in equipment damage or loss of data. Performing or omitting a specific action may result in electrical shock. 12

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download them onto a local workstation or server. 13

Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales and corporate information. Online Support Email and Telephone Support Returning Products Sales or Corporate Information Warranty Management Software Updates You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions. For Technical Support via email or telephone, refer to the Support section of the Allied Telesis web site: www.alliedtelesis.com. Products for return or repair must first be assigned a return materials authorization (RMA) number. A product sent to Allied Telesis without an RMA number will be returned to the sender at the sender s expense. For instructions on how to obtain an RMA number, go to the Support section on our web site at www.alliedtelesis.com. You can contact Allied Telesis for sales or corporate information through our web site at www.alliedtelesis.com. The AT-GS950/16 and AT-GS950/24 Switches have a Lifetime Warranty (24 Months Fan and PSU). Go to www.alliedtelesis.com/warranty for the terms and conditions of the warranty and for warranty registration. New releases of the management software for our managed products are available from the following Internet sites: Allied Telesis web site: www.alliedtelesis.com Allied Telesis FTP server: ftp://ftp.alliedtelesis.com If the FTP server prompts you to log on, enter anonymous as the user name and your email address as the password. 14

Chapter 1 Overview This chapter describes the AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches. The sections in the chapter are. Features on page 16 Front and Back Panels on page 17 Ports on page 18 LEDs on page 19 Power Supply on page 21 Network Topologies on page 22 15

Chapter 1: Overview Features The features of the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Switches include: LEDs for unit and port status 16 or 24 Auto-Negotiating 10/100/1000Base-T twisted pair ports with RJ-45 connectors Two small form-factor pluggable (SFP) ports Auto MDI/MDI-X on the twisted pair ports IEEE 802.3 and IEEE 802.3u compliant IEEE 802.3x flow control in full-duplex operation; back pressure in half-duplex operation IEEE 802.1P based Quality of Service support IEEE 802.1Q based tagged VLAN support IEEE 802.1X based authentication Port mirroring Link aggregation Store and forward switching mode Dynamic Host Configuration Protocol (DHCP) client 8K MAC address table with automatic aging Menus- and web-based configuration using the AT-S79 management software 16

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Front and Back Panels Figure 1 illustrates the front panels of the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Switches. AT-GS950/16 AT-GS950/16 16-Port 10/100/1000Mbps + 2 SFP Combo WebSmart Switch 1 3 5 7 9 11 13 15 SPEED LINK/ACT SPEED LINK/ACT LINK/ACT POWER 2 4 6 8 10 12 14 16 15 16 1295 Port and System LEDs 10/100/1000Base Twisted Pair Ports SFP Ports Console Port AT-GS950/24 AT-GS950/24 24-Port 10/100/1000Mbps + 2 SFP Combo WebSmart Switch 1 3 5 7 9 11 13 15 17 19 21 23 SPEED LINK/ACT SPEED LINK/ACT LINK/ACT POWER 2 4 6 8 10 12 14 16 18 20 22 24 23 24 Port and System LEDs SFP Ports 10/100/1000Base Twisted Pair Ports SFP Ports 1296 Console Port Figure 1. AT-GS950/16 and AT-GS950/24 Front Panels Figure 2 illustrates the back panel of the switches. AT-GS950/16 and AT-GS950/24 Figure 2. AT-GS950/16 and AT-GS950/24 Back Panels 733 17

Chapter 1: Overview Ports The AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches feature 16 or 24 twisted pair ports and two slots for optional SFP transceivers. Twisted Pair Ports The twisted pair ports are 10Base-T, 100Base-TX, and 1000Base-TX compliant. They automatically set their speed and duplex mode with IEEE 802.3u Auto-Negotiation. If desired, you can disable Auto-Negotiation on a port and manually set the speed and duplex mode. Note If a switch port is connected to an end node that is not using Auto- Negotiation, you should disable Auto-Negotiation on the port and set its speed and duplex mode manually. Otherwise, a duplex mode mismatch might occur. The twisted pair ports feature 8-pin RJ-45 connectors. For the port pinouts, refer to Connectors and Port Pinouts on page 42. The ports have a maximum operating distance of 100 m (328 feet). For 10 Mbps operation, the ports require Category 3 or better 100 ohm shielded or unshielded twisted pair cabling. For 100 or 1000 Mbps operation, the ports require Category 5 or Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted pair cabling. Also featured on the ports is auto-mdi, which automatically configures the ports as MDI or MDI-X. This allows you to use straight-through twisted pair cable regardless of the configuration of the ports on the end nodes. Uplink Combo Ports The switch has two pairs of uplink ports, each consisting of one 10/100/ 1000Base-T twisted pair port and one slot for an optional SFP transceiver. The ports are numbered 15 and 16 on the AT-GS950/16 Switch and 23 and 24 on the AT-GS950/24 Switch. You can use one port in a combo pair at a time. A link on an SFP transceiver takes precedence over a link on a 10/100/1000Base-T twisted pair port in the same combo pair. If the SFP slot is empty or if it has an SFP module but the module does not have a link to an end node, the 10/100/1000Base-T twisted pair port of the pair is active. If an SFP transceiver is installed and has a link to an end node, the twisted pair port in the pair is inactive. RS-232 Console Port The RS-232 console port is for local management of the switch with the AT-S79 Management Software. Local management uses the management cable supplied with the switch. 18

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide LEDs The LEDs shown in Figure 3 display system and port status information. AT-GS950/16 A T -GS950/16 16- P o r t 10/100/1000Mbps + 2 SFP Combo W ebsma r t Switch 1 3 5 7 9 11 13 15 SPEED LINK/ A C T SPEED LINK/ A C T LINK/ A C T P O WE R 2 4 6 8 10 12 14 16 15 16 1297 AT-GS950/24 A T -GS950/24 24-P or t 10/100/1000Mbps + 2 SFP Combo W ebsma r t Switch 1 3 5 7 9 11 13 15 17 19 21 23 SPEED LINK/ACT SPEED LINK/ACT LINK/ACT 2 4 6 8 10 12 14 16 18 20 22 24 P O WE R 23 24 1298 Figure 3. AT-GS950/16 and AT-GS950/24 System and Port LEDs Table 2 describes the system LEDs. Table 2. System LEDs LED State Description POWER Off The switch is not receiving power. On The switch is receiving power. Table 3 describes the LEDs for the 10/100/1000Base-T ports. Table 3. 10/100/1000Base-T Port LEDs LED State Description SPEED On The port is operating at 1000 Mbps. Off The port is operating at 10/100 Mbps or no link is established. 19

Chapter 1: Overview Table 3. 10/100/1000Base-T Port LEDs (Continued) LED State Description LINK/ACT Off The port has not established a link with an end node. Blinking Green Green The port is transmitting or receiving data. A valid link has been established on the port. Table 4 describes the LEDs for the SFP ports. Table 4. SFP Port LEDs LED State Description LINK/ACT Off The port has not established a link with an end node. Blinking Green Green The port is transmitting or receiving data. A valid link has been established on the port. 20

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Power Supply The switches have an internal power supply with a single AC power supply socket on the back panel which features autoswitch AC inputs. To power the switch on or off, connect or disconnect the power cord provided with the switch. A power cord is supplied with the switch. Note For the power requirements, refer to Power Specifications on page 41. 21

1 3 5 7 9 11 13 15 17 19 21 23 SPEED LINK/ACT SPEED LINK/ACT LINK/ACT POWER 2 4 6 8 10 12 14 16 18 20 22 24 23 24 Chapter 1: Overview Network Topologies This section illustrates two network topologies of the AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches: a power workgroup and collapsed backbone. Power Workgroup Topology The topology shown in Figure 4 is commonly referred to as a power workgroup topology. This topology provides the best in performance and reliability because each end node is connected directly to the AT-GS950/ 24 Switch with a dedicated network link. AT-GS950/24 Switch AT-GS950/24 24-Port 10/100/1000Mbps + 2 SFP Combo WebSmart Switch 1296 Legend 100 Mbps 1000 Mbps Figure 4. Power Workgroup Topology 22

1 3 5 7 9 11 13 15 SPEED LINK/ACT SPEED LINK/ACT LINK/ACT POWER 2 4 6 8 10 12 14 16 15 16 10M 1000M 100M LINK/ACT FDX POWER 1 2 3 4 5 6 7 8 10/100/1000B AS E -T G iga bit E thernet S witch 1 2 3 4 5 6 7 8 561 AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Collapsed Backbone In the topology illustrated in Figure 5 the AT-GS950/16 is connected to other managed and unmanaged Ethernet switches to form a collapsed backbone topology. The AT-GS950/16 Switch functions as the focal point of the network by transferring Ethernet frames between the switches. This topology reduces the amount of unnecessary traffic in each workgroup, because the AT-GS950/16 Switch transfers frames only when the source and destination end nodes are located on different switches. This frees up bandwidth and improves network performance AT-GS950/16 Switch AT-GS950/16 16-Port 10/100/1000Mbps + 2 SFP Combo WebSmart Switch 1295 AT-GS900/16 Switch AT-GS900/8E Switch AT-G S 900/8E 600 AT-GS900/24 Switch 601 Legend 10 Mbps 100 Mbps 1000 Mbps Figure 5. Collapsed Backbone Topology 23

Chapter 1: Overview 24

Chapter 2 Installation This chapter contains the following sections: Reviewing Safety Precautions on page 26 Selecting a Site for the Switch on page 28 Cable Specifications on page 29 Unpacking the Switch on page 30 Installing the Switch on a Desktop on page 31 Installing the Switch in an Equipment Rack on page 32 Installing an Optional SFP Transceiver on page 34 Cabling the Switch on page 37 Powering On the Switch on page 38 25

Chapter 2: Installation Reviewing Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements (613-000405) posted on the Allied Telesis website at www.alliedtelesis.com. Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of electric shock, disconnect electric power to the product before connecting or disconnecting the LAN cables. E1 Warning: Do not work on equipment or cables during periods of lightning activity. E2 Warning: Power cord is used as a disconnection device. To deenergize equipment, disconnect the power cord. E3 Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. E4 Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling. E6 Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40 degrees C. E7 All Countries: Install product in accordance with local and National Electrical Codes. E8 26

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. E21 Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading. E25 If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature (Tmra). E35 Caution: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. E36 Warning: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips). E37 27

Chapter 2: Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, ensure that the table is level and secure. The power outlet for the switch should be located near the unit and should be easily accessible. The site should provide for easy access to the ports on the front of the switch. This will make it easier for you to connect and disconnect cables, as well as view the switch s LEDs. To allow proper cooling of the switch, air flow around the unit and through its vents on the side and rear should not be restricted. Do not place objects on top of the switch. Do not expose the switch to moisture or water. Ensure that the site is a dust-free environment. You should use dedicated power circuits or power conditioners to supply reliable electrical power to the network devices. 28

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Cable Specifications Table 5 contains the cable specifications for the twisted pair ports. Table 5. Twisted Pair Cabling and Distances Speed Type of Cable Maximum Operating Distance 10 Mbps Standard TIA/EIA 568-B-compliant Category 3 or better shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz. 100 Mbps Standard TIA/EIA 568-A-compliant Category 5 or TIA/EIA 568-Bcompliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. 1000 Mbps Standard TIA/EIA 568-A-compliant Category 5 or TIA/EIA 568-Bcompliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. 100 m (328 ft) 100 m (328 ft) 100 m (328 ft) Note The twisted pair ports on the switch feature auto-mdi when operating at 10, 100 or 1000 Mbps. Each of the ports is individually configured as MDI or MDI-X when connected to an end node. Consequently, you can use a straight-through twisted pair cable when connecting any type of network device to a port on the switch. 29

Chapter 2: Installation Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Place the switch on a level, secure surface. 3. Verify that the following hardware components are included in your switch package. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance. One AT-GS950/16 or AT-GS950/24 Smart Switch Two rack-mount brackets Eight rack-mount bracket screws (black) Four rack-mounting screws (stainless steel) Four rubber feet (for desktop use) One management cable One power cord Documentation CD 30

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Installing the Switch on a Desktop You can install the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches on a desktop or in a standard 19-inch equipment rack. To install the switch in a rack, refer to Installing the Switch in an Equipment Rack on page 32. To place the switch on a desktop, perform the following procedure: 1. Remove all equipment from the package and store the packaging material in a safe place. 2. Turn the switch over and attach the four rubber feet to the bottom of the switch as shown in Figure 6. AT-GS950/16 16-Port 10/100/1000Mbps + 2 SFP Combo WebSmart Switch 1 3 5 7 9 11 13 15 SPEED LINK/ACT SPEED LINK/ACT POWER 2 4 6 8 10 12 14 16 15 16 LINK/ACT 1299 Figure 6. Attaching the Rubber Feet 3. Turn the switch over again and place it on a flat, secure surface (such as a desk or table) leaving ample space around the unit for ventilation. 31

Chapter 2: Installation Installing the Switch in an Equipment Rack To install the switch in a standard 19-inch equipment rack, perform the following procedure: 1. If attached, remove the rubber feet using a flat-head screwdriver. 2. Install a bracket on one side of the switch using a Phillips screwdriver and four of the rack-mount screws included with the switch. Figure 7 and Figure 8 illustrate installing the brackets on the AT-GS950/16 and AT-GS950/24 Switches, respectively. 16 761 Figure 7. Attaching the Rack-Mount Bracket to the AT-GS950/16 Switch 23 24 743 Figure 8. Attaching the Rack-Mount Bracket to the AT-GS950/24 Switch 3. Repeat step 2 to attach the remaining bracket to the other side of the switch. 32

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 4. Mount the switch in a standard 19-inch equipment rack using the four large screws included. Figure 9 and Figure 10 show how to mount the AT-GS950/16 Switch and AT-GS950/24 Switch, respectively. 16 762 Figure 9. Mounting the AT-GS950/16 Switch in an Equipment Rack 23 24 760 Figure 10. Mounting the AT-GS950/24 Switch in an Equipment Rack 33

Chapter 2: Installation Installing an Optional SFP Transceiver The AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches have two slots for optional SFP transceivers. To install an SFP transceiver, perform the following procedure: Note The transceiver can be hot-swapped; you do not need to power off the switch to install a transceiver. However, always remove the cables before removing the transceiver. Note You should always install the transceiver before connecting the fiber optic cables to it. 1. Remove the transceiver from its shipping container and store the packaging material in a safe location. Warning An SFP transceiver can be damaged by static electricity. Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the transceiver. 2. Remove the dust plug from the SFP slot, as shown in Figure 11. 737 Figure 11. Removing the Dust Plug from the SFP Slot 3. Position the SFP transceiver with the label facing up. 34

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 4. Slide the transceiver into the SFP slot until it clicks into place. 738 Figure 12. Inserting the SFP 5. Verify that the handle on the transceiver is in the upright position, as shown in Figure 13. This secures the transceiver and prevents it from being dislodged from the slot. SFP Transceiver Handle 1300 Figure 13. Positioning the SFP Handle in the Upright Position 6. Repeat steps 2 through 5 to install another SFP transceiver. Note SFP transceivers are dust sensitive. When a fiber optic cable is not installed, or when you store the SFP, always keep the plug in the optical bores. When you do remove the plug, keep it for future use. 35

Chapter 2: Installation Note Unnecessary removal and insertion of an SFP can lead to premature failure. For information on the cable specifications of the SFP, consult the documentation shipped with the SFP. 36

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Cabling the Switch Observe the following guidelines when connecting twisted pair and fiber optic cables to the ports on the switch: The connector on the cable should fit snugly into the port on the switch. The tab on the connector should lock the connector into place. Because the twisted pair ports have auto-mdi/mdi-x, you can use straight-through twisted pair cable to connect any type of network device to the switch. If your network topology contains a loop where two or more network devices can communicate with each other over more than one network path, do not connect the network cables forming the loop until after you have activated the Rapid Spanning Tree Protocol on the switch. Data loops can adversely affect network performance. If you are creating a port trunk, configure the switch s management software before connecting the cables of the trunk to the switch. Otherwise, a network loop will result which can adversely affect network performance. In order for a switch port to successfully Auto-Negotiate its duplex mode with an end node, the end node should also be using Auto- Negotiation. Otherwise, a duplex mode mismatch can occur. A switch port using Auto-Negotiation defaults to half-duplex if it detects that the end node is not using Auto-Negotiation. This can result in a mismatch if the end node is operating at a fixed duplex mode of full-duplex. To avoid this problem, disable Auto-Negotiation on a switch port and set the port s speed and duplex mode manually if the end node has a fixed duplex mode of full-duplex. 37

Chapter 2: Installation Powering On the Switch To power on the switch, perform the following procedure: 1. Plug the power cord into the AC power connector on the back of the switch, as shown in Figure 14. 741 Figure 14. Plugging in the AC Power Cord 2. Plug the other end of the power cord into a wall outlet. Warning: Power cord is used as a disconnection device. To deenergize equipment, disconnect the power cord. E3 Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 3. Verify that the POWER LED is green. If the LED is OFF, refer to Chapter 3, Troubleshooting on page 39. The switch is now powered on and ready for network operations. For information on how to manage the switch, refer to the AT-S79 Management Software User s Guide. 38

Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Telesis Technical Support. Refer to Contacting Allied Telesis on page 14. Check the POWER LED on the front of the switch. If the LED is off, indicating that the unit is not receiving power, do the following: Verify that the power cord is securely connected to the power source and to the AC connector on the back panel of the switch. Verify that the power outlet has power by connecting another device to it. Try connecting the unit to another power source. Try using a different power cord. Verify that the voltage from the power source is within the required levels for your region. Verify that the LINK/ACT LED for each port is ON. If a LINK/ACT LED is OFF, do the following: Verify that the end node connected to the port is powered on and is operating properly. Verify that the twisted pair cable is securely connected to the port on the switch and to the port on the end node. Verify that the twisted pair cable does not exceed 100 meters (328 feet). Verify that you are using the appropriate category of twisted pair cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 and 1000 Mbps operation. Note A 1000Base connection may require five to ten seconds to establish a link. 39

Chapter 3: Troubleshooting 40

Appendix A Technical Specifications Physical Specifications Dimensions: AT-GS950/16 330 mm x 230.7 mm x 43.2 mm (12.99 in x 9.08 in x 1.7 in) AT-GS950/24 440 mm x 257 mm x 43.2 mm (17.32 in x 10.12 in x 1.7 in) Environmental Specifications Weight: AT-GS950/16 2.38 kg (5.25 lbs) AT-GS950/24 3.25 kg (7.15 lbs) Operating Temperature: 0 C to 40 C (32 F to 104 F) Storage Temperature: -25 C to 70 C (-13 F to 158 F) Operating Humidity: Storage Humidity: Operating Altitude Range: 5% to 90% non-condensing 5% to 95% non-condensing Up to 3,000 m (9,843 ft) Power Specifications Input Supply Voltage: Power Consumption: 100-240 VAC, 50-60 Hz AT-GS950/16 33 W AT-GS950/24 37.2 W 41

Appendix A: Technical Specifications Safety and Electromagnetic Emissions Certifications EMI/RFI: FCC Class A, EN55022 Class A, CISPR Class A Immunity: EN55024 Connectors and Port Pinouts Electrical Safety: EN60950 (TUV), UL60950 ( c UL us), C-TICK, CE This section lists the connectors and connector pinouts for the AT-GS950/16 and AT-GS950/24 switches and their components. Figure 15 illustrates the pin layout for an RJ-45 connector and port. 8 8 1 1 Figure 15. RJ-45 Connector and Port Pin Layout Table 6 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration. Table 6. MDI Pin Signals (10Base-T or 100Base-TX) Pin Signal 1 TX+ 2 TX- 3 RX+ 6 RX- 42

AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide Table 7 lists the RJ-45 port pin signals when a twisted pair port is operating in the MDI-X configuration. Table 7. MDI-X Pin Signals (10Base-T or 100Base-TX) Pin Signal 1 RX+ 2 RX- 3 TX+ 6 TX- Table 8 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps. Table 8. RJ-45 1000Base-T Connector Pinouts Pin Pair Signal 1 1 TX and RX+ 2 1 TX and RX- 3 2 TX and RX+ 4 3 TX and RX+ 5 3 TX and RX- 6 2 TX and RX- 7 4 TX and RX+ 8 4 TX and RX- 43

Appendix A: Technical Specifications 44