Business. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation

Similar documents
Performs many operations, from batch weighing to field bus networking applications.

C500 Series Data Sheet

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

21e Multi-Function Indicator

Vibration-Resistant Weighing Indicator

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

EXCELL PRECISION CO., LTD.

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

Please keep the following using conditions certainly

APEX Junior Cased Weighing Indicator/Controller

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

M260 Load Cell Amplifiers

This document hosted by: Extension Load Cell Cable (OP-02)

LC0 DVP

INTECONT PLUS for Measuring Systems

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

Weighing Indicator. Features. Description. Applications

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER

GUIDE PROGRAMMABLE PANEL METER M905

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

Characteristics and functioning

UniPak UP448 Bridge Input Isolating Signal Conditioner

Table of Contents 1. Introduction Features & Main function Technical Specification Measure of Appearance...

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

DXp-10 and DXp-15 Weight Transmitter

Analog Amplifier FAA-27. Technical Manual. Flintec GmbH Bemannsbruch Meckesheim GERMANY.

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

! User Manual Rev. 1

Characteristics and functioning

E1110 multi-function weight indicator

Digital Weighing Indicator SI 4630 (For both External Display and Indicator)

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

ANALYTICAL/SEMI-MICRO BALANCES

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

GS100P. Weighing Controller. Contents. Order Codes

Presented By. NicolScales.com Contact Us

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

DD2050 Hopper Scale. datasheet

ANALYTICAL/SEMI-MICRO BALANCES

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

LAUREL ELECTRONICS, INC.

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

SY021 Portable Load/Force Meter User instructions

INTECONT Tersus Mass flow rate measurement

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Strain Gauge Converter

COIN COUNTING SCALE TC-290 SERIES. Count Any Coin, Any Quantity, Anywhere, In Three Seconds Accurately!

This document hosted by: 10. OPTIONS

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

SAFETY INSTALLATION OPERATION MAINTENANCE

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Loop Powered Display Spec. Sheet

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

895/896M Frequency Output Math Modules

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

MODEL 9250 Preliminary data sheet

Maxxis 4 Process Controller with BASIC Application

Counting On Your Process Preset Counters

Technical Parameter... 4 Installation and Connection... 5

QC-3265 Checkweigher User s Manual

Counting Scales. HC-i Series

AD-4401 WEIGHING INDICATOR A-IE

Installation Manual. WKC Weigh Modules

B BALANCES MicroBalances/Analitycal

E1205 advanced multi-function indicator

Chennai Weighing System

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual)

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

EC Type Examination Certificate

Process displays For current and voltage

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

N420 R420 R423. series

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Operating Instructions VEGAMET 381

Mu-checker To support building the system with automatic measuring unit or dedicated gages

Operator Interfaces Introduction & Selection Guide SELECTION GUIDE INTRODUCTION UCT-31P

General information. Display. Supply voltage

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

VEGA II. Electronic counter. The solutions that count

INDI BOY DSP Load limitation electronics

The Fusion Series of Large displays

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Digital Indicator Solutions

Weighing Electronics SIWAREX - PLC-based weighing electronics

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Transcription:

Business 1 2 Industrial Automation Indicator - Simple Digital Weighing Indicator - Universal Weighing Indicator - Packaging Control Indicator - Multiple Mixture Control Indicator - DIN Size Digital Weighing Indicator Professional Controller - Single or Double types Packer - Single or Double types Filler - Customized Professional controller - Check Weigher - Single or Double types of Packing Components - Truck Scale System - Automatic Vehicle Weighing System - Delivery line system Weighing Sensor - Standard Load Cell - Customized Load Cell - Multi- Pivot sensor - Torque sensor - Other sensors Accessories - Printer - Control Box/Panel - Load Cell Summing box - Others Republic of SEWHACNM to the world beyond

Selection Guide Indicator Selection Guide INDICATOR SI 4000 SI 4010 SI 4010R SI 4100 SI 4200 SI 4300 SI 4400 SI 4410 SI 4500 SI 4630 SI 200 SI 480E SI 580E SI 300 Hold Sub Display Parts Number Memory (kinds) 50 50 50 50 50 50 50 50 50 Control Method (step) 2 4 2 3 2 3 2 2 (pcs) 3 6 6 5 6 6 6 4 (pcs) 4 4 4 4 4 4 4 4 4 2 4 APPLICATION SI 4000 SI 4010 SI 4010R SI 4100 SI 4200 SI 4300 SI 4400 SI 4410 SI 4500 SI 4630 SI 200 SI 480E SI 580E SI 300 Truck Scale Animal Scale Tension / Compression Meter Limit Mode SELECTION GUIDE Checker Hopper Packer Filler Discharge Weighing Accumulating Weighing Batch Mode External Display Remote Control DIN Size Wall / Rail Mounting INTERFACE & OPTION SI 4000 SI 4010 SI 4010R SI 4100 SI 4200 SI 4300 SI 4400 SI 4410 SI 4500 SI 4630 SI 200 SI 480E SI 580E SI 300 Current Loop RS232C Parallel Print Interface Analog Out 0 ~ 10V Analog Out 4 ~ 20mA Extention serial Port BCD In BCD Out Ethernet OP-1 OP-2 OP-3 RS232C OP-41 RS422 RS485 OP-42 OP-43 OP-5 OP-6 OP-7 Standard Installed S Select Standard Installed Ordering Spec S S S SI 4000 Series Explode EXPLODE SI 480E / SI 580E Series Explode - 5 -

INDICATOR SI 4000 Digital Simple Indicator - Industrial Scale (Truck, Tank, Platform, Animal Scale) - : 4 pcs Input Built-in - RS232C & Current Loop Standard Built-in - Auto Print Mode - Hold Function (Sample / Peak / Average Hold) OPTION PART (Max 2EA) Min. 0.2 V / Digit Load Cell Excitation DC 10V ( ± 5V ) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 Sub Display OP-1 OP-2 OP-3 7 Segment, 7 Digit Green VFD, H = 12.7mm STEADY, ZERO, TARE, GROSS, AUTO, PRINT, HOLD g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / 4.0 kg RS232C & Current Loop Standard Built-In Parallel Printer Interface Analogue Output (0~10V) Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 OP-6 OP-7 BCD Input (to Change P/N) BCD Output Ethernet Truck Scale Crane Scale Tester Animal Scale Tank Scale PRODUCT SPECIFICATION APPLICATION - 6 -

SI 4010 Digital Simple Indicator INDICATOR - Industrial Scale / Simple Volume Hopper Application - : 4 pcs Input Built-in - RS232C & Current Loop Standard Built-in - Hold Function (Sample / Peak Hold) - Large Display View (1.0 inch) of Weight Value SPECIFICATION OPTION PART (Max 2EA) Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 7 Segment, 6 Digit Red FND, H = 25.4mm Sub Display STEADY, ZERO, TARE, g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In OP-1 OP-2 Analogue Output (0~10V) OP-3 Analogue Output (4~20mV) OP-41, OP-42, OP-43 OP-5 BCD Input (to Change P/N) OP-6 BCD Output OP-7 APPLICATION PRODUCT Truck Scale Crane Scale Tester Tank Scale - 7 -

INDICATOR SI 4010R High & Low Control Indicator - Industrial Scale (Truck, Tank, Limit, Packer, Hopper Scale) - : 4 pcs Input Built-in - Control : 3 pcs Output Built-in - RS232C & Current Loop Standard Built-in - Auto Print Mode (M+ / M-) - Hold Function (Sample / Peak Hold) OPTION PART (Max 2EA) WEIGHING MODE Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 Sub Display OP-1 OP-2 OP-3 7 Segment, 6 Digit Red FND, H = 25.4mm STEADY, ZERO, TARE, g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 3 EA Parallel Printer Interface Analogue Output (0~10V) Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 OP-6 OP-7 Limit Mode 1 Limit Mode 2 BCD Input (to Change P/N) BCD Output Ethernet Normal Open Normal Close Auto Packer Crane Scale Tester Conveyer Scale Tank Scale PRODUCT SPECIFICATION APPLICATION - 8 -

SI 4100 Universal Weighing Indicator INDICATOR - Universal Purpose (Package, Weight Check, Accumulation) - : 4 pcs Input Built-in - Control : 6 pcs Output Built-in - RS232C & Current Loop Standard Built-in - Hold Function (Sample / Peak Hold) - Visible Output Relay On Front Panel (Ø2 Red LED) SPECIFICATION OPTION PART (Max 2EA) WEIGHING MODE Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 7 Segment, 7 Digit Green VFD, H = 12.7mm Sub Display STEADY, ZERO, TARE, GROSS, AUTO, PRINT, COMM SP1, SP2, SP3, SP4, g, kg, t AC 110/220V, 50/60Hz, About 20W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 6 EA OP-1 Parallel Printer Interface OP-2 Analogue Output (0~10V) OP-3 Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 BCD Input (to Change P/N) OP-6 BCD Output OP-7 Ethernet Limit Mode Packer Mode Checker Mode User s Choice Mode Accumulating Mode APPLICATION PRODUCT Conveyer Scale Tester Crane Scale Tank Scale Auto Packer - 9 -

INDICATOR SI 4200 Quantity Control Indicator ( ) - : 4 pcs Input Built-in - Control : 6 pcs Output Built-in - RS232C & Current Loop Standard Built-in - Visible Output Relay Signal on Panel (Ø2 Green LED) - Unit Weight Calibration OPTION PART (Max 2EA) WEIGHING MODE Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 Sub Display OP-1 OP-2 OP-3 7 Segment, 7 Digit Green VFD, H = 12.7mm 7 Segment, 6 Digit Red FND 3 Lines, H = 9.2mm STEADY, ZERO, TARE, GROSS, AUTO, PRINT, COMM g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 6 EA Parallel Printer Interface Analogue Output (0~10V) Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 OP-6 OP-7 Auto Packer Limit Mode Packer Mode Checker Mode BCD Input (to Change P/N) BCD Output Ethernet Auto Counting Scale PRODUCT SPECIFICATION APPLICATION - 10 -

SI 4300 Weight Check Control Indicator INDICATOR - Check Weigher / Testing Purpose Indicator - : 4 pcs Input Built-in - Control : 5 pcs Output Built-in - RS232C & Current Loop Standard Built-in - Weight Check Mode : Photo Sensor Mode / Peak Hold Mode - Hold Tracking Mode : Hold Set (Over Empty) Hold Reset (Under Empty) - Under / Pass / Over / N.G Count Mode (Selectable) SPECIFICATION OPTION PART (Max 2EA) WEIGHING MODE Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 7 Segment, 7 Digit Green VFD, H = 12.7mm Sub Display 7 Segment, 6 Digit Red FND 3 Lines, H = 9.2mm STEADY, ZERO, TARE, HOLD, GROSS, PRINT, COMM g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 5 EA OP-1 Parallel Printer Interface OP-2 Analogue Output (0~10V) OP-3 Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 BCD Input (to Change P/N) OP-6 BCD Output OP-7 Ethernet Photo Sensor Input Mode Hold Key Input Mode Simple Comparison Mode APPLICATION PRODUCT Tester - 11 -

INDICATOR SI 4400 Packaging Control Indicator - Professional Packer / Filler Control Indicator - : 4 pcs Input Built-in - Control : 6 pcs Output Built-in - RS232C & Current Loop Standard Built-in - Automatic Free Fall (In-Fight) Compensation Function - Compensate Even Minus(-) Free Fall Value OPTION PART (Max 2EA) WEIGHING MODE Auto Packer Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 Sub Display OP-1 OP-2 OP-3 7 Segment, 7 Digit Green VFD, H = 12.7mm 7 Segment, 6 Digit Red FND 3 Lines, H = 9.2mm STEADY, ZERO, TARE, HOLD, GROSS, PRINT, COMM g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 6 EA Parallel Printer Interface Analogue Output (0~10V) Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 OP-6 OP-7 Limit Mode 1 Limit Mode 2 Packer Mode User s Mode Weighing & Dscharging BCD Input (to Change P/N) BCD Output Ethernet Normal Open Normal Close Filler PRODUCT SPECIFICATION APPLICATION - 12 -

SI 4410 Packaging Control Indicator INDICATOR - Professional Packer / Filler Control Indicator - Control : 5 pcs Relay (3 set points) - RS232C & Current Loop Standard Built-in - Loss In Weight Modes - Automatic Free Fall (In-Fight) Compensation Function - Compensate Even Minus(-) Free Fall Value SPECIFICATION OPTION PART (Max 2EA) WEIGHING MODE Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 7 Segment, 7 Digit Green VFD, H = 12.7mm Sub Display 7 Segment, 6 Digit Red FND 4 Lines, H = 9.2mm STEADY, ZERO, TARE, HOLD, GROSS, PRINT, COMM g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 6 EA OP-1 Parallel Printer Interface OP-2 Analogue Output (0~10V) OP-3 Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 BCD Input (to Change P/N) OP-6 BCD Output OP-7 Ethernet Limit Mode Packer Mode Loss-In Weight Mode Minus(-) Weighing Mode Discharge Mode APPLICATION PRODUCT Auto Packer Weighing & Dscharging Filler - 13 -

INDICATOR SI 4500 Multiple Mixture Control INdicator - Multiple Accumulating Mixture Control Indicator - Control : 6 pcs (2 Set Points for Each BIN) - Max 16 Kinds Materials Mixed With 50 Different Formulas - Each Material Is Controlled By Bin Pre 1 & Bin Final Value - Batch Process Back-Up Mode Added - Transferred Data Selection Current / Accumulated Weight OPTION PART (Max 2EA) Min. 0.2 V / Digit Load Cell Excitation DC 10V (± 5V) 0.005% of Full Scale Max 500 times / sec, Sigma-Delta Resolution Internal : 1/520,000 (19 bit), External: 1/20,000 Sub Display BCD Input & BIN Output Standard Built-in OP-1 OP-2 OP-3 7 Segment, 7 Digit Green VFD, H = 12.7mm 7 Segment, 6 Digit Red FND 4 Lines, H = 9.2mm STEADY, ZERO, TARE, STB, RUN, PRINT, COMM g, kg, t AC 110/220V, 50/60Hz, About 30W (W)200 x(h)105 x(d)175 mm / Gross 4.0 kg RS232C & Current Loop Standard Built-In 6 EA Parallel Printer Interface Analogue Output (0~10V) Analogue Output (4~20mV) OP-41, OP-42, OP-43 Serial Interface RS232C / 422 / 485 OP-5 OP-6 OP-7 BCD Input (to Change P/N) BCD Output Ethernet PRODUCT SPECIFICATION APPLICATION - 14 -

SI 480E DIN Size Digital Simple Indicator INDICATOR - Industrial Scale (Truck, Tank, Platform, Animal Scale) - 1/8 Din Size : (W)96 x(h)48 x(d)135mm / 0.7kg - Control Panel Mounting type - External Resolution : 1/20,000 - Internal Resolution : ±1/1,000,000 (21 Bit) - DC 24V SMPS - RS485 & RS422 Serial Interface Standard Built-in - Hold Function (Sample / Peak / Average Hold) 135 96 48 SPECIFICATION Min. 0.1 V / Digit Load Cell Excitation DC 5V 0.001% of Full Scale Max 60 times / sec, Sigma-Delta Resolution Internal : 1/1,000,000, External: 1/20,000 7 Segment, 6 Digit Red FND, H = 16.2mm Under Zero Minus (-) Display STEADY, ZERO, TARE, HOLD, Tx, Rx, F DC 24V, 8W (SMPS) (W)96 x(h)48 x(d)135 mm / Gross 0.7 kg Standard : RS422 & RS485, RS232C : Ordering Spec 2 EA Print RS232C Serial Print Mode APPLICATION PRODUCT Truck Scale Crane Scale Tester Animal Scale Tank Scale co - 15 -

INDICATOR SI 580E DIN Size Universal Weighing Indicator - Industrial Scale (Packer, Tank, Hopper Scale) - 1/8 Din Size : (W)96 x(h)48 x(d)135mm / 0.9kg - Control Panel Mounting type - External Resolution : 1/20,000 - Internal Resolution : ±1/1,000,000 (21 Bit) - DC 24V SMPS - RS485 & RS422 Serial Interface Standard Built-in - Analog Output 4 ~ 20mA Standard (0 ~ 10V : User Selection) WEIGHING MODE Load Cell Excitation Min. 0.1 V / Digit DC 5V 0.001% of Full Scale Max 60 times / sec, Sigma-Delta Resolution Internal : 1/1,000,000, External: 1/20,000 Under Zero Analog Output Print 135 Limit Mode Packer Mode 96 7 Segment, 6 Digit Red FND, H = 16.2mm Minus (-) Display STEADY, ZERO, TARE, OUT1, OUT2, OUT3, OUT4 DC 24V, 8W (SMPS) (W)96 x(h)48 x(d)135 mm / Gross 0.9 kg Slot 1 - Standard : RS422 & RS485, RS232C :Ordering Spec Slot 2 - Standard : RS232C, RS422 & RS485 :Ordering Spec Basic : 4 ~ 20mA (0~10V : User Selection) Accumulating Mode 48 RS232C Serial Print Mode PRODUCT SPECIFICATION APPLICATION Auto Packer Auto Cacker Filler Applicaton - 16 -

SI 200 Wall / Rail Mounting Type Idicator INDICATOR PRODUCT - Wall / Rail Mounting Type Indicator - Micro Din Size : (W)49 x(h)96 x(d)41mm / 140g - 1/20,000 High Resolution - RS232C & 485 Selectable Interface - Easy to Wire By Front Connecting Terminal - DC 12V SMPS - Hold Function (Sample / Peak / Average Hold) SPECIFICATION Min. 0.1 V / Digit Load Cell Excitation DC 5V 0.001% of Full Scale Max 60 times / sec, Sigma-Delta Resolution Internal : 1/1,000,000, External: 1/20,000 7 Segment, 6 Digit Red FND, Letter Size : H = 7.6 mm Under Zero Minus (-) Display STEADY, ZERO, TARE, RTxD DC 12V, 8W (SMPS) (W)48 x(h)96 x(d)41 mm / 0.4 kg Standard : RS232C / RS485 (User Selection) Print RS232C Serial Print Mode APPLICATION Truck Scale Crane Scale Tester Animal Scale Tank Scale - 17 -

INDICATOR SI 300 Digital Weighing Indicator - Simple / Wall / Desk Mounting Type 2012 NEW Product - Industrial Scale (Truck, Animal, Platform, Tank etc.) - Wall / Desk Mounting Type - Peak Hold, Sample Hold, Average Hold - Watch-Dog, Weight Back-Up - Aluminium Case to Block Electromagnetic waves - RTC (Real Time Clock) - Connectable with External Display, Computer, PLC - RS232C, Current Loop Interface Load Cell Excitation DC +5V Min. 0.1 V / Digit 0.001% of Full Scale Max ± 3.2 mv/v Max 60 times / sec, Sigma-Delta Resolution Internal : 1/1,000,000 External: 1/20,000 Drift Under Zero Relay Ourput Data Back-Up HOLD Mode ZERO SPAN Front View 236 190 204 10 PPM / C 10 PPM / C 7 Segment, 6 Digit Red FND, Letter Size : H = 25.4 mm (1 inch) Minus (-) Display STEADY, ZERO, TARE, HOLD, TxD, RxD, F Free Voltage (AC100V ~ AC 240V, 50/60Hz) Temperature : -10 C ~ +40 C[14 F ~ 104 F], Humidity :Under 85% RH (W)236 x(h)170 x(d)122 mm / Gross 1.8kg RS232C, Current Loop Weight Back-Up Sample / Peak / Average Hold Right View 122 Bottom View 80 160 Mount Hole 3-Ø5.5 THRU PRODUCT SPECIFICATION APPLICATION Truck Scale Crane Scale Tester Animal Scale Tank Scale - 18 -

SI 4630 External Type Indicator INDICATOR PRODUCT - Apply 3.0 inch size FND Display of Hight Brightness - Industrial Scale & Simple Volume Packer Application - RS232C & current Loop Standard - Wall Mounting Type - Wireless Remot Controller (Option) SPECIFICATION Min. 0.2 V / Digit Load Cell Excitation DC 5V 0.001% of Full Scale Max 60 times / sec, Sigma-Delta Resolution Internal : 1/1,000,000, External: 1/20,000 7 Segment, 5 Digit Red FND, Letter Size : H = 3 inch Under Zero Minus (-) Display STEADY, ZERO, TARE, CHECK Free Voltage (AC100V ~ AC 240V, 50/60Hz) (W)400 x(h)150 x(d)170 mm / Gross 4.7 kg RS232C & Current Loop Standard Built-in Key Pad Wired Key Pad Standard Holde Mode Sample / Peak / Average Hold Option Part RS485, Wireless Key pad APPLICATION Truck Scale Fish Scale Crane Scale Animal Scale - 19 -

INDICATOR SI 300/4000/4630/4200 System Application INDUSTRIAL SCALE - USING SI300 / SI4000 / SI4630 PC Software TS90 RS232C External Display SE6135A Current Loop Indicator SI 300 / SI 4000 / SI 4630 QUANTITY CONTROL APPLICATION USING SI4200 BASIC APPLICATION SI4200 External Display SE6135A Load Sell SB900 / SBW INDUSTRIAL SCALE - USING SI 300 / 4000 / 4630 QUANTITY CONTROL APPLICATION USING SI 4200-20 -

SI 4300/4400/4410 System Application INDICATOR AUTO CHECK WEIGHING APPLICATION USING SI 4300 AUTO CHECK WEIGHING APPLICATION USING SI4300 In Feed C/V Photo Sensor Weighing C/V Tower Lamp Control Rejecter Control (Sequence Board) Reject C/V AUTO PACKER - USING SI4400 AUTO PACKER - USING SI 4400 TARE Check Weighing Control Normal Operation SI 4400 LOSS IN WEIGHING APPLICATION SUING SI 4410 LOSS IN WEIGHING APPLICATION USING SI4410 (1) 1 Step Feeding / 2 Step Discharge Mode PRE 1 : Feeding Limit (ON : Stop Feeding / OFF : Start Feeding) PRE 2 : Bulk Discaharge FINAL : Target FREE FALL (1) 2 Step Feeding / 1 Step Discharge Mode PRE 1 : Under Limit of Feeding PRE 2 : Over LImit of Feeding FINAL : Target FREE FALL - 21 -

INDICATOR SI 4500/480E/580E System Application ACCUMULATING MIXING APPLICATION USING SI4500 SI480E, SI580E NETWORK COMPOSITION BY RS422 Rx + Rx - Tx + Tx - T + T - R + R - ACCUMULATING MIXING APPLICATION USING SI 4500 SI 480E, SI 580E NETWORK COMPOSITION BY RS422 Max 32 Set of SI480E or SI580E are Connectable - 222 -

INDICATOR Indicator Box & Printer Indicator Box - Material : Polyester Coating Steel - Gross Weight : 3 ~ 7 kg - (Switch) - Switch Can be Changeable - Customized : SUS Type INDICATOR BOX SE4010 SE4011 SE4020 SE4021 AC IN, Load cell Connector POWER, ZERO, TARE, PRINT POWER, PRINT (W)280 x(h)240 x(d)300mm (W)230 x(h)120 x(d)250mm (W)400 x(h)260 x(d)330mm (W)250 x(h)260 x(d)270mm Printer MODEL SE7200 (Desk Type) SE7300 (Panel Type) SE 7300 S / D D : Dot Impact Type T : Thermal Type S : Serial Type P : Parallel Type 7200 : Desk Type 7300 : Panel Type PRINTER DIMENSION / WEIGHT (W)110 x(l)165 x(d)85mm / 1.5kg (W)120 x(l)130 x(d)90mm / 1.5kg CUTTING SIZE (W)107 x(h)113mm POWER Standard : DC 12V, 1.5A, Option : Adapter AC 110V/220V OPERATING CONDITION Temperature: 0 C ~ 50 C PRINTING METHOD Dot Impact Type Thermal Type COLUMNS 24/30 40 24/32 36/42 FONT SIZE Eng: 8x14, Kor: 16x14 Eng: 6x12, Kor: 12x12 Eng: 12x24, Kor: 24x24 Eng: 9x24, Kor: 18x24 SPEED 1.6 line/sec. 60 mm/sec. DOT / LINE 240 384 PAPER INFO (W)57mm x Ø50 Roll Paper (W)57mm x Ø50 Thermal Roll Paper CARTRIDGE ERC - 09 INTERFACE RS232C Serial / Centronics Parallel SUPPLIES Cartridge : ERC-09 Roll Paper : (W)57mm x Ø50 (Dot / Thermal) Load cell Accessories LOAD CELL ACC 10.0 14.0 6.0 2.0 24.0 1.0 * BALL Ø18.0 Ball & Ball Cup Foot - 23 -

EXTERNAL DISPLAY SE6125A / SE6135A SE6145A / SE6165A A HEIGHT WEIGHT SE 6125A 2.3 inch 2.5 kg POWER Unit (mm) A B C D E F G H SE 6125A 330 131 150 70 255 50 SE 6135A 400 151 170 70 275 50 SE 6145A 545 183 185 70 290 50 SE 6165A 720 247 210 70 325 70 OPERATING CONDITION DIMENSION A x B x C (mm) 330 x 131 x 150 SE 6135A 3 inch 4.5 kg AC95 ~ 240V - 10 C ~ + 40 C 400 x 151 x 170 SE 6145A 4 inch 7.0 kg 50/60 Hz Under 85% RH 545 x 183 x 185 SE 6165A 6 inch 9.0 kg 720 x 247 x 210 Truck Scale G C E D Indicator - Wall Mounting Type - RS232C / RS485, Current Loop Selectable - Connectable to Other Brand s Indicators. - Auto Recovery Function - Speed Auto Setting (2,400 ~ 115,200 bps) - Buzzer Option 57 73 SE6125A / SE6135A / SE6145A / SE6165A PRODUCT SPECIFICATION APPLICATION Animal Scale Indicator SE6125A / SE6135A / SE6145A / SE6165A - 24 -