Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Similar documents
1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Manual Documentation Number EIR418-2SFP-T 0912m

LNX-0702G-SFP Series

LNX-1002C-SFP Series

Korenix JetNet 3705 Series Industrial Power over Ethernet Switch User s Manual

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

gigabit industrial ethernet user manual Models , ,

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Industrial Slim Type Fast Ethernet Rail Switch

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

MDI/MDIX) FEP-32005T-2

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

DynaGST/2402G USER S MANUAL

Industrial Unmanaged Ethernet Switch

Fast Ethernet Converter. User Guide MICROSENS

USER S MANUAL. 5 and 8 Port 10/100/1000Base-T Gigabit Ethernet Switches

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

IMC-21A Quick Installation Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

5-Port 10/100Mbps with 4-Port PoE. Industrial Fast Ethernet Switch ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF. User's Manual

KFC-200. Installation Guide

Industrial Media Converter

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Ether-FSH2400C 24-port 10/100Base-TX Switch

IMC-21 Quick Installation Guide

GSW-2453 Gigabit Chassis switch. User Guide

5-Port 10/100TX with 4 PoE Injector Industrial Switch

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

MOXA Industrial Media Converter

Industrial Managed Ethernet Switch

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

PTC-101 Quick Installation Guide

MC-4TX Series Industrial 4 Port Ethernet to Media Converter. Industrial 4 Port Ethernet to Fiber Media Converter. Part of GE Security

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

JetCon 1301 / 1301-mw / 1301-sw

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

Industrial Ethernet Switch

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

TN-5308 Quick Installation Guide

EKI-7529MI, EKI-7529MI/ST FX Port Unmanaged Industrial Ethernet Switch. User Manual

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

PTC-101-M12 Hardware Installation Guide

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

IFS MC350-1T-2S User Manual

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

16/24-Port Gigabit Desktop Switch

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

XPress-Pro SW User Guide

IFS MC-4TX Series Industrial Ethernet Switch User Manual

Industrial PoE Media Converter

RS Series Quick Start Industrial Redundant Ring Switch Version 1.0

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

GEU Port Gigabit Switch

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

TRP-C41 User s Manual

Manual Elinx EIRHP305-T. 5 Ports10/100 with 4 PoE Ports Unmanaged Din Rail Ethernet Switch

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch. User Manual

Hardened PoE Ethernet Switch

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

IMC-21GA Quick Installation Guide

Features and Benefits. Certifications

Transcription:

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Fourth Edition, DEC, 2007 www.korenix.com

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Copyright Notice Copyright 2005 Korenix Technology Co., Ltd. All rights reserved. Reproduction in any form or by any means without permission is prohibited.

Table of Contents Chapter 1 Introduction...1-1 Overview... 1-2 Product Features... 1-2 Package Checklist... 1-2 Chapter 2 Hardware Installation...2-1 Introduction... 2-2 Panel Layout... 2-2 Dimensions... 2-3 LED Indicators... 2-3 DIP Switches... 2-5 Wiring the Power Inputs... 2-6 Wiring the Ethernet Ports... 2-6 Wiring the Fiber Ports... 2-6 Cabling... 2-7 DIN-Rail Mounting Installation... 2-7 Wall-Mounting Installation... 2-8 Installation and Testing... 2-10 Chapter 3 Troubleshooting...3-1 Appendix A Specifications... A-1 Appendix B Revision History... B-1

Chapter 1 1 Introduction Welcome to Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch. JetNet 3000 Series includes 3 models: JetNet 3005, JetNet 3008, and JetNet 3005f. JetNet 3000 Series is an entry-level rail switch that is specially designed for industrial applications. The following topics are covered in this chapter: Overview Product Features Package Checklist

Overview Industrial environments are usually more demanding than office environments. Harsh temperature conditions, vibration, dust, etc. all put a test on the quality and reliability of your switches. To survive harsh industrial environments, Korenix provides you with JetNet 3000 Series, an Industrial 5-/8-port (with a fiber port) Entry Level Ethernet Rail Switch. JetNet 3000 Series Industrial Entry Level 5-port/8-port (with a fiber port) Ethernet Rail Switch is a cost-effective solution ideal for your industrial applications in harsh environments. JetNet 3000 Series not only gives you high speed data transmission over an Ethernet network, but also provides redundant power inputs and reverse polarity protection. In addition, JetNet 3000 uses an IP30 aluminum case, and has passed several safety certifications, ensuring customers a cost-effective, safe, and reliable industrial applications. JetNet 3005f supports fiber connectors, effectively extending switches transmission distance. Product Features Korenix JetNet 3000 Series products have the following features: 5-port /8-port 10/100T(X) industrial switch for JetNet 3005/3008 4-port 10/100T(X) and 1-port 100F(X) for JetNet 3005f Supports store-and-forward switching architecture Supports IEEE 802.3 10Base-T, 802.3u 100Base-TX, and 100Base-FX standard Supports auto MDI/MDI-X function Embedded memory: JetNet 3005/3005f: 512 KB JetNet 3008:1024 KB Supports IEEE 802.3x flow control Flow control for full-duplex mode Back pressure for half-duplex mode Provides redundant dual power inputs Aluminum case with IP30 protection MAC address table JetNet 3005/3005f: 1K JetNet 3008: 2K DIN-Rail and wall mountable design Package Checklist Korenix JetNet 3000 Series products are shipped with the following items: JetNet 3000 Industrial Entry-Level 5-port/8-port Ethernet Rail Switch One DIN-Rail clip (attached with the JetNet) One wall mounting plate and six screws User s manual CD-ROM Quick Installation Guide If any of the above items is missing or damaged, please contact your local sales representative. 1-2 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

2 Hardware Installation Chapter 2 This chapter includes information of installation and configuration. The following topics are covered in this chapter: Introduction Panel Layout Dimensions LED Indicators DIP Switches Wiring the Power Inputs Wiring the Ethernet Ports Wiring the Fiber Ports Cabling DIN-Rail Mounting Installation Wall-Mounting Installation

Introduction Panel Layout JetNet 3005 Front View 1 LED indicators 2 RJ45 Ethernet ports JetNet 3008 Front View 1 LED indicators 2 RJ45 Ethernet ports 2-2 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardware Installation JetNet 3005f Front View 1 LED indicators 2 RJ45 Ethernet ports 3 Fiber Port 4 DIP Switch Bottom View The bottom view of the JetNet 3000 Industrial Entry-Level 5-port/8-port Ethernet Rail Switch consists of one terminal block connector with two DC power inputs and one DC IN power jack for an additional AC/DC power adapter. Dimensions JetNet 3000 Industrial Entry-Level 5-port/8-port Ethernet Rail Switch dimensions (W x H x D) are 54mm x 135mm x 105mm. LED Indicators There are 5 diagnostic LEDs and 8 Port LEDs located on the Front panel of JetNet 3005/3005f Industrial Ethernet Rail Switch. These LED indicators provide administrators with real-time system status. The table below gives descriptions of the function of each LED indicator. Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual 2-3

LED Status Description PWR PWR 1 PWR 2 LNK/ACT of Port 5 FDX/COL of Port 5 Port Status (Port 1 to 4) Green Green Green Green Blinks Orange Blinks Orange Blinking orange Green Blinking green Power is on. No power is being supplied. Power is on. No power is being supplied. Power is on. No power is being supplied. A network device is detected. The port is transmitting or receiving packets from the TX (FX) device. No device is attached. The port is operating in full-duplex mode. Collision of packets occurs. The port is in half-duplex mode or no device is attached. The port is operating in full-duplex mode. Collision of packets occurs. The port is in half-duplex mode or no device is attached. A network device is detected. The port is transmitting or receiving packets from the TX device. No device is attached. There are 7 diagnostic LEDs and 12 Port LEDs located on the Front panel of JetNet 3008 Industrial Ethernet Rail Switch. These LED indicators provide administrators with real-time system status. The table below gives descriptions of the function of each LED indicator. LED Status Description PWR PWR 1 PWR 2 LNK/ACT of Port 7/8 Green Green Green Green Blinks Power is on. No power is being supplied. Power is on. No power is being supplied. Power is on. No power is being supplied. No power, or UTP port, or fiber port failure occurs. A network device is detected. The port is transmitting or receiving packets from the TX device. No device is attached. 2-4 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardware Installation FDX/COL of Port 7/8 Port Status (Port 1 to 6) Orange Blinks Blinks Orange Blinking orange Green Blinking green The port is operating in full-duplex mode. Collision of packets occurs. The port is in half-duplex mode or no device is attached. Collision of packets occurs. The port is in half-duplex mode or no device is attached. The port is operating in full-duplex mode. Collision of packets occurs. The port is in half-duplex mode or no device is attached. A network device is detected. The port is transmitting or receiving packets from the TX device. No device is attached. DIP Switches DIP SWITCH Status Description Fiber Port (JetNet 3005f) ON Fiber Half-duplex mode Fiber Full-duplex mode(default) There is a set of DIP Switches located on the front panel of JetNet 3005f. This set of DIP Switches is for configuring the fiber port s transmission modes (full/half duplex). Note: If two 3005fs are up-linked with each other through fiber ports, the communication speed would be slow if one JetNet3005 is configured to be full-duplex mode and the other one is configured to be half-duplex mode. To obtain stable communication quality, be sure the DIP switch is setting in same mode and have executed system power rest to perform it exactly. DIP Switches Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual 2-5

Wiring the Power Inputs 1. Insert the positive and negative wires into the V+ and V- contact on the terminal block connector. 2. Tighten the wire-clamp screws to prevent the DC wires from being loosened. Note: The suitable electric wire ranges from 12 to 24 AWG. Note: The additional power jack is designed for office use. Wiring the Ethernet Ports RJ-45 ports with auto MDI-MDI-X function: JetNet 3005/3005f has five/four 10/100 Mbps auto-sensing ports for 10Base-T or 100Base-TX device connection. The UTP ports will auto-detect 10Base-T and 100Base-TX connections. Auto MDI/MDI-X function allows users to connect another switch or workstation without changing straight-through or cross-over cabling. See the figures below for the schematic diagram of straight-through and cross-over cabling. Straight-through Cabling Schematic Cross-over Cabling Schematic All ports of JetNet 3005/3008 support auto-mdi/mdi-x function. When you use an Ethernet cable to connect other devices, such as computers, switches or hubs, pin 1, 2, 3, and 6 of the 8-pin RJ45 connector are used to communicate with the connected devices. Pin1, 2, 3, and 6 s signals are converted by the MDI-X function, as shown in the table below. Pin MDI-X Signals MDI Signals 1 RD+ TD+ 2 RD- TD- 3 TD+ RD+ 6 TD- RD- Wiring the Fiber Ports To connect the fiber port on your JetNet 3005f to another one located on another JetNet, follow the figure below. Wrong connection will cause fiber ports not to work normally. 2-6 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardware Installation Cabling JetNet fiber models have two 100Base-FX ports with SC type connectors. Fiber segment using single mode must use 8/125 or 9/125 um single-mode fiber cables. For single mode, the connection distance can be up to 30 km. Fiber segment using multi mode must use 50 or 62.5/125 um multi-mode fiber cables. For single mode, the connection distance can be up to 2 km. The cable connection between the JetNet 3005/3008 and the attached devices (switches, hubs, workstations, etc.) must be less than 100 meters (328 ft.) long. The fiber cable connection between the JetNet 3005f and the attached devices (switches, hubs, workstations, etc.) must be less than 2000 meters long with multimode and 30000 meters with single mode. DIN-Rail Mounting Installation The DIN-Rail clip is already attached to the JetNet 3000 Series products when packaged. If the DIN-Rail clip is not screwed on the JetNet, follow the instructions and the figure below to attach the DIN-Rail clip to the JetNet. 1. Use the screws to attach the DIN-Rail clip to the rear panel of the JetNet. 2. To remove the DIN-Rail clip, reverse step 1. Follow the steps below to mount the JetNet to the DIN-Rail track. 1. First, insert the upper end of the DIN-Rail clip into the back of the DIN-Rail track from its upper side. Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual 2-7

2. Lightly push the bottom of the DIN-Rail clip into the track. 3. Check if the DIN-Rail clip is tightly attached on the track. 4. To remove the JetNet from the track, reverse the steps above. Wall-Mounting Installation Follow the steps below to install the JetNet with the wall mounting plate. 1. To remove the DIN-Rail clip from the JetNet, loosen the screws from the DIN-Rail clip. 2. Place the wall mounting plate on the rear panel of the JetNet. 3. Use the screws to tighten the wall mounting plate onto the JetNet. 4. Use the hook holes at the corners of the wall mounting plate to hang the JetNet onto the wall. 5. To remove the wall mounting plate, reverse the steps above. 2-8 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardware Installation Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual 2-9

Installation and Testing The following figure illustrates a typical application of JetNet 3000 Series Industrial 5-port/8-port Entry-Level Ethernet Rail Switch. 2-10 1. Take your JetNet 3005/3008/3005f Industrial 5-port/8-port Entry Level Rail Switch out of the package box. 2. Check if the DIN-Rail clip is attached to the JetNet 3005/3008/3005f. If the DIN-Rail clip is not attached to the JetNet3005, refer to DIN-Rail Mounting section for DIN-Rail installation. If you want to wall-mount the JetNet 3005/3008, refer to Wall Mounting section for wall mounting installation. 3. To place the JetNet 3005/3008/3005f on the DIN-Rail track or wall, refer to the Mounting Installation section. 4. Pull the terminal block off the JetNet 3005/3008/3005f and wire the power lines. Refer to the Wiring the DC Power Inputs section for how to wire the power inputs. 5. PWR1 and PWR2 dual power inputs can be connected to power sources simultaneously. When the primary power source fails (the default setting is PWR1), the system will automatically switch to the secondary power source (PWR2), preventing any power interruption. 6. Check the LED for PWR1 and PWR2 to make sure that your JetNet is operating normally. Note: If you are using DC IN power jack to supply power to the JetNet, please check the PWR LED. 7. Use Category 5 straight through Ethernet cables with RJ45 connectors to connect network devices. 8. Connect one side of an Ethernet cable with a RJ45 connector to the JetNet s Ethernet port (RJ-45 port), and the other side of the Ethernet cable to the network device s Ethernet port (RJ-45 port). Note: Make sure that the connected network switches support MDI/MDI-X function. If they do not support this function, use a crossover Ethernet cable. 9. Check the port status LED indicator (blinking green) on the JetNet to see if the network connection is successfully established. Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Hardware Installation 10. Power on the host, activate the Command Line mode, and ping the connected Ethernet device to see if it will respond. 11. To enable the Command Line mode, click on Run in the Start menu, type Command, and click on OK to continue. 12. Type ping 192.168.1.1 command to check the connection. Here we use IP address 192.168.1.1 as an example. 13. Repeat step 10 to make sure that the connection of each device connected to the JetNet 3005/3008/3005f is successfully established. 14. Power on the host, activate the Command Line mode, and ping the connected Ethernet device by typing ping t 192.168.1.1 command to see if it will respond. 15. The parameter t allows you to continue to ping the network device, as shown in the figure below. Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual 2-11

Before you continue, make sure that both PWR1 and PWR2 are successfully connected to power sources. When PWR1 fails, the LED for PWR1 will go out. At that moment, if the ping command is still being replied to, then it proves that the redundant power input function works normally. 16. Exit the Command Line mode, and connect PWR1 power input. At this stage, your JetNet 3005/3008/3005f has been tested and the installation is complete. 17. See the figure below for setting up your industrial network with JetNet 3005s. Computer A needs to connect several modems simultaneously in order to let a big number of users to access this industrial network. However, Computer A does not have additional COM ports to connect all of the modems. For this reason, we use a network solution. 18. We network enable the modems via serial-to-ethernet converters, and use Ethernet cables to connect Computer A and converters to the JetNet 3005. Enter Command Line mode in Computer A, and use ping command to see if the connections between Computer A and the converters are working properly, as described in step 10 and 11. 19. Enter Telnet program in Computer A, type in the IP address of one of the converters, and configure the serial port s communication parameters. Follow this procedure to set up the other converters. 20. Install the virtual com port driver, and enter converters IP addresses. 21. Click on Computer A s Control Panel Device Manager, and make sure the system each converter s IP address is mapped to the corresponding com port. 22. Click on Computer A s Dialer, and install modem driver. Configure the modem s corresponding com port as a virtual com port, enter a set of telephone number, and start dialing. Verify that the modem did dial up, and the serial port s communication parameters are correct. Follow this procedure to verify each converter s parameters are correct. 23. Click on Computer A s dial out manager, and change the modem s setting from dial up to dial in. Follow this procedure to finish each modem s setting. The industrial network is now established successfully. Computer A is able to connect several converters using over the Ethernet via JetNet 3005 Industrial 5-port Entry Level Ethernet Rail Converter, providing a reliable network environment. 2-12 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

3 Troubleshooting Chapter 3 This chapter includes the information on general troubleshooting. Make sure you are using the correct VDC power suppliers (12 to 48 VDC) or power adapters. Do not use power adapters with DC output over 48V. It will damage devices. Select Ethernet cables with specifications suitable for your applications to set up your systems. Ethernet cables are categorized into unshielded twisted-pair (UTP) and shielded twisted-pair (STP) cables. Category 3, 4, 5 Ethernet cables are suitable for systems with 10 Mbps transmission speed. For systems with 100 Mbps transmission speed, Category 5 Ethernet cables are the only suitable specifications for this environment. You also need to make sure that the distance between each node cannot be longer than 100 meters (328 feet). IF the power indicator does not turn on when the power cord is plugged in, you may have a problem with power cord. Than check for loose power connections, power losses or surges at power outlet. IF you still cannot resolve the problem, contact your local dealer for assistance.

A Specifications Appendix A Standards Protocols Technology Transmission Rate MAC address table size Memory Buffer LED Network Cables Power Supply Power consumption Packet throughput ability Installation IEEE 802.3 10BaseT Ethernet IEEE 802.3u 100BaseT(X)/100BaseF(x) Fast Ethernet IEEE802.3x Flow Control and Back pressure CSMA/CD Store and Forward 14,880 pps for Ethernet port 148,800 pps for Fast Ethernet port JetNet3005/3005f: 1K MAC address table JetNet3008: 2K MAC address table JetNet3005/3005f: 512Kbits JetNet3008: 1024Kbits Per port: Link/Activity (Green) Full duplex/collision (Orange) Per unit: Power, Power 1,Power 2(Green) 10BaseT: twisted-pair UTP/STP Cat. 3, 4, 5 cable EIA/TIA-568 100-ohm (100m) 100BaseT(X): twisted-pair UTP/STP Cat. 5 cable EIA/TIA-568 100-ohm (100m) SC (Multi-mode): 50/125um~62.5/125um SC (Single mode): 9/125um~10/125um Available distance: 2KM (Multi-mode) / 30KM (single-mode) Wavelength: 1310nm (multi-mode/ single mode) 12 to 48 VDC, redundant dual DC power inputs with reverse polarity protection, and a removable terminal block for master and slave VDC power inputs. JetNet3005: 2.8 Watts JetNet3008: 4.6 Watts JetNet3005/3005f: 0.74Mpps @ 64bytes (5TX/4TX+1FX) JetNet3008: 1.19Mpps @ 64bytes (8TX) DIN-Rail kit and wall mounting panel Operating Temperature -10 C to 70 C Operating Humidity 5 to 95% (non-condensing)

Storage Temperature -40 C to 85 C Storage Relative Humidity Dimensions EMI EMC Safety Stability 5 to 95%(non-condensing) 54 mm (W) x 135 mm (H) x 105mm (D) FCC Class A EN61000-4-2, EN61000-4-3, EN-61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 UL, CUL, CE/EN60950, IP-30 IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) A-2 Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

B Revision History Appendix B Document Edition Revision Date Revision Details 2 nd March 2004 Added descriptions related to JetNet 3008. 3 rd May 2005 Added descriptions related to JetNet 3005f. 4 th DEC,2007 Add notice related to JetNet 3005f