Connecting a Cisco Input Module

Similar documents
Connecting a Cisco Output Module

Connecting a Cisco Reader Module

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

IEI emerge MicroNode Install and Setup Guide. Contents

TruPortal Dual Door Interface Module Quick Reference

Digital Keypad Introduction

EA500. Installation Instructions Transponder

INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card

Identiv Connected Physical Access Manager 2.1 Installation Guide

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

CA-A480-A Elevator Controller. Reference & Installation Manual

4 Channel DMX Driver Instruction Manual

Identiv Connected Physical Access Manager 3.0 Installation Guide

RTU560 Connections and Settings DIN Rail RTU 560CIG10

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

IPassan Installation guide

MouldFlo Wiring Manual

FSM-510G Series Ethernet Management Switch Quick Start Guide

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

8~14-Port Managed Ethernet Switch

MOTION COORDINATOR MC405 Quick Connection Guide

Single Door Standalone Access Control User Manual

Hardware Installation

MOULDFLO WIRING MANUAL

C5S120 Installation and Connection Guide

Installing the DX LCD Display

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

I/O Expansion Module Installation & Reference

Installation Guide. Avigilon ACM Embedded Controller

Suprex RS-485 SPX-7500 Wired Reader-Extender

Installing Sentor. Hardware Installation

Key Switch. Document version: 1.5 (Updated 02 May 2017)

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

HI SEC Integrated Systems

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

TCNM-ACBB1 Installation Manual

TruPortal Output Expansion Board Quick Reference

Access Terminal IF-800

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

RTU560 Remote Terminal Unit Connections and Settings

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

SCR100 User Manual. Version:1.1 Date:Dec 2009

CM-110SK Standalone Keypad Installation Instructions

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

Installation Instructions (KF-2000)

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

INSTALLATION INSTRUCTIONS

MODEL DRIVER Ic Ip VDC

GLOSSARY. See also: Access point

Quick Start Installation Guide

Quick Start Installation Guide

Expansion Module HZS 541-1S

AirTest Model CN9000 Series Sensor Controller

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

2.1 MANAGEMENT UNIT INSTALLATION

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual

Plus-X IIU / ICRU Installation Guide

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

Industrial Ultra Power over Ethernet Splitter IPOE-171S

DIN-RAIL EXPANDER int-iors_en 10/14

Edge Device with Brivo ACS Plug-in for WebServices and OnSite SE. Quick Start Guide

Installation Instructions Model PSC-17C

Cisco ONS CL Shelf Assembly Hardware

Quick Start Installation Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Digital encoder interface module 5/12/24 V DANGER

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

ADDENDUM FOR 20, 27, & 28 OPTIONS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

AC5160 SiPass integrated controller kit

RS232 Control Box. Table of contents

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

MANUAL Conversion instruction EDM series to VDM100 series

MR52 READER INTERFACE

CONTROL PROTOCOL Motorized Projection Screens

Overview of the Cisco Wireless Gateway for LoRaWAN

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Peristaltic Cased Tube Pump

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

EN TECHNICAL MANUAL. Audio module Art and Art. 1622L

Cardax FT Controller 3000

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Technical Manual for RT-EX-9017

Transcription:

CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each connection can be configured as supervised or unsupervised. A supervised connection is a four- state connection to determine if the connection is (1) short (2) is open (3)normal state or (4) alarm state. An unsupervised input indicates only normal or alarm. Figure 4-1 Cisco Input Module 4-1

Package Contents Chapter 4 The optional Cisco Input Module is connected to a Cisco Physical Access Gateway or Cisco Reader Module using a CAN connection to provide connections for additional input devices, as, as shown in Figure 4-2. Figure 4-2 Cisco Reader Module connected to the Cisco Physical Access Gateway Cisco Input or Output Module (Optional) Additional Input/Output devices CAN connection Door Readers and Input/Output devices Layer2 Switch Ethernet V Cisco Access Gateway CAN connection Cisco IP Network Cisco Access Control Manager 271597 Door Readers and Input/Output devices Cisco Reader Module (Optional) CAN connection Additional Input/Output devices Cisco Input or Output Module (Optional) Package Contents Each Cisco Input Module includes the following: 20 resistors (1K) for input supervision 2 mounting brackets, with 4 screws for each bracket Regulatory compliance and safety information Quick start guide 4-2

Chapter 4 Physical Overview and Port Description Connector plugs: Type Quantity 3 Pin 1 2 Pin 13 Physical Overview and Port Description Each Cisco Input Module includes 10 ports for connecting additional input devices. as shown in Figure 4-3. Figure 4-3 Cisco Input Module Ports and Connectors 6 5 4 3 2 1 187043 4-3

Physical Overview and Port Description Chapter 4 Figure 4-4 Cisco Input Module Ports and Connectors: Top View 4 5 6 3 2 1 The following items are shown in Figure 4-3 and Figure 4-4: 187039 Type Description 1 Power Two-pin connector for Voltage In (VIN) and Ground (GND) to connect a 12 to 24 VDC external power source. 2 CAN interface A 3-wire CAN bus is used to connect additional modules. Note Modules are connected using the CAN1 interface. The CAN2 interface is not supported in this release. 3 CAN Terminator The CAN terminator switch is set to ON for the last device in a CAN wiring bus. This switch is set to set to OFF for all other devices in the CAN bus. 4 Input connections Ten input interfaces used to sense the contact closure. Each input can be configured as supervised or unsupervised and can be configured to sense a Normally Open (NO) or Normally Closed (NC) contact. An unsupervised input senses a simple contact closure state, including Normal or Alarm. When connected to open contacts, the terminal voltage range is 4V to 5V. For closed contacts, the voltage range is 0V to 0.7V. A supervised input senses four contact states, including Normal, Alarm, Open and Short. These inputs require 1K End-Of-Line (EOL) termination resistors installed at the contacts (two resistors are included in the accessory kits for each Input port). 4-4

Chapter 4 Installing the Cisco Input Module Type Description 8 PF Power fail input: an unsupervised input that raises a power fail alarm when the circuit is open. Can be configured as an additional unsupervised port. The corresponding LED is red when circuit is open (when no input is connected). 9 TM Tamper input: an unsupervised input that raises a tamper alarm when the circuit is open. Can be configured as an additional unsupervised port. The corresponding LED is red when circuit is open (when no input is connected). Status LEDs Each input port includes a status LED that indicates the following information: Table 4-1 Input Module LEDs Status OFF GREEN BLINKING GREEN BLINKING RED RED Description Input is not configured Input is configured and in normal state Input is configured, and is receiving and alarm or other data. Input is configured, short Input is configured, open Installing the Cisco Input Module Install a Cisco Input Module is provide additional input connections for a Cisco Reader Module or Gateway Before You Begin Verify the following: Verify that the module has access to a power source. See Power Options and Requirements, page 1-10 for more information. Verify that you have the necessary mounting brackets or other hardware. See Mounting a Gateway or Optional Module, page 1-11. Installation Procedure To install the module, perform the following procedure: Step 1 Mount the module to a wall. See Mounting a Gateway or Optional Module, page 1-11 for more information. 4-5

Installing the Cisco Input Module Chapter 4 Step 2 Connect the module to the DC power source: a. Insert a two-pin connector plug into the DC power port (Figure 4-5) b. Connect the Voltage In (VIN) and ground (GND) wires. See Power Options and Requirements, page 1-10 for more information. Figure 4-5 Power Connections for the Input and Output Modules 271599 2 1 The following items are shown in Figure 4-5: Configuration 1 DC power GND (ground) 2 DC power Voltage In (VIN) Description Connects the DC ground wire to the module. Connects the DC Voltage In (VIN) wire to the module. Step 3 Connect the module to the CAN bus: a. Insert a three-pin connector plug into the CAN1 port, as shown in Figure 4-6. b. Connect the CAN wires to the CAN bus, as shown in Figure 4-7 c. Turn the CAN terminator ON if the device is the last device in a CAN wiring bus. Note The CAN terminator switch in included on the Reader, Input and Output modules only (the Gateway is always the first device in the CAN bus). Set the terminator switch to OFF for all other modules in the CAN bus. Note The CAN2 interface is not supported in this release. See Optional Expansion Modules, page 1-6 for more information. 4-6

Chapter 4 Installing the Cisco Input Module Figure 4-6 CAN Connections: Input and Output Modules 271598 4 1 2 3 The following items are shown in Figure 4-6: Configuration Description 1 CAN+ Connects to the positive terminal of the CAN bus. 2 CAN- Connects to the negative terminal of the CAN bus. 3 Shield Connects to GND and/or Shield. 3 CAN Terminator Turn the terminator ON if the device is the last device in a CAN wiring bus. Figure 4-7 CAN Bus Wiring CAN+ Sheild CAN- Gateway Module Reader Module Input Module Output Module 271589 Step 4 Connect input devices to the module: a. Insert two-pin connector plugs into the input ports. b. (Optional, for supervised input connections only). Install two End-Of-Line (EOL) 1K termination resistors in each supervised input interface (one terminator in each connector). Figure 4-8 shows the terminator installation for a Normally Closed (NC) and Normally Open (NO) input connection. 4-7

Installing the Cisco Input Module Chapter 4 Figure 4-8 Input Connections: Cisco Physical Access Gateway and Reader Module 1K,, 1% 1K,, 1% NC 1K,, 1% 1K,, 1% NO 187838 c. Connect the wires from the input devices. Note Each of the input connections can be configured as supervised or unsupervised. The tamper (TM) and power fail (PF) inputs can be configured as additional unsupervised ports. A supervised input supports four states: normal, alarm, open and short. An unsupervised input indicates only normal or alarm. Step 5 See the User Guide for Cisco Physical Access Manager for information to configure the module ports. 4-8