Version 2. Inline Relay (500W) Model No. LW821. Instruction Manual. Connect Series.

Similar documents
Version 2. On/Off/Stop Switch. Model No LW826. Instruction Manual. Connect Series.

Power Socket (1 Gang)

Version 2.1. Socket Locker. Model No. LW103. Instruction Manual. Connect Series.

It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void.

It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void.

PIR Movement Sensor. Instruction Manual. Connect Series. Model No. JSJSLW107. Version 2

Dimmable Energy Saving CFR with Mood Remote. Model No s: JSJS LW560/561/562

Q. Can I use LED bulbs? A. Yes as long as the bulbs are dimmable variants and compatible.

lightwaverf Lightwave Link Model No. JSJSLW500 Instruction Manual Connect Series

User Manual - Energenie MiHome Double Wall Sockets (MIHO07, MIHO021, MIHO022, MIHO023)

Internet Control Station

Digital Room Thermostat

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Installation and Hardware Guide

PRO-HC IRRIGATION CONTROLLER

OT EASY 60 II. LED control unit Operating instructions

Rako RAK4-R Instruction Manual

Temperature Controller

Weathersafe Vision. Installation & Operating Instructions

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

Operating and Maintenance Instructions

PanelView Plus/VersaView CE Terminals and Display Modules

Non-communicating room controllers

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.

Quick Start Guide.

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

GSM-Route BRI 3G. Installation & User Guide

Extension module for lighting control

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

INSTEON ToggleLinc. INSTEON Dimmer Switch. For models:

Sollatek SVS Range Voltage Stabilisers User Manual

Assembly and Operating Instructions Door Control

Digital Thermostat for drum heaters Model HCL 5536


LC2300 Level Controller Installation and Maintenance Instructions

LED W RGBA User Manual

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Please read this safety information carefully and keep this user manual for later reference.

Documentation on all Paxton products can be found on our web site -

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

PC200 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

3.3: Setting momentary / latching switches Page Warning Regarding Operation Page 8

1 Channel Strobe Controller ORDERCODE 40226

NCH-1000 (Multiple Breaker Types) Installation Instructions

Product Data Sheet. Hochiki 8 Way I/O Card. Features

I-RK01 Radio Keypad. Installation Guide. 2 abc. 3 def. 4 ghi. 6 mno. 5 jkl. 8 tuv 9 wxyz. 7 pqrs

BOOSTMASTER ELECTRONIC BOOST TIMER

VR 80 Remote Control Device

Deluxe In/Out Remote Thermometer with Trend Chart

focus HAND channel wireless DMX riggers remote Users Manual Software version: 1.0

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Room unit with PPS2 interface

Satellite INSTALLATION GUIDE

Nokeval. FD100 series. User Manual

INSTEON SwitchLinc 1000W. INSTEON Dimmer Switch. For models: SwitchLinc V2 Dimmer 1000W

DEEP SEA ELECTRONICS PLC

OCTOPUS CONTROL STATION

User Manual Energenie MiHome Monitor adapter

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Mounting and Operating Instructions

Wireless 7 Day Programmable Room Thermostat

Phoebe LED Spectrum 10W RGB/Tuneable White downlight INSTALLATION AND APP INSTRUCTIONS

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

When Not in Use: Remove the batteries if this device is to be left unattended or unused for a long period of time.

1. Package contents. 2. Connecting ADSL modem and wireless router

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

MAINSLINK-RX. Features: Quick and Simple to Install. Up to 500m range outdoor. Up to m range in buildings* Reliable high end radio link

RMB Peripheral Units Installation Guide

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

SoundwebTM. Installation Guide

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

ALL-IN-ONE BLUETOOTH GARDEN SPEAKERS

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

TXM1.8RB. TX-I/O Blinds module

Push Button Interface UP 220D31

AW12 IN WALL APPLIANCE MODULE

NSD/M1 Installation Instructions

TL-PA4010 AV600 Powerline Adapter

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Model HM-535 Power Supply Installation and Service Instructions

ZenNet Installation Guide:

Heating Circuit Controller

IGLOO IGLOO EASY INSTRUCTION MANUAL

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

Digital Clamp-on Meter Instruction Manual

WIRELESS KINETIC SWITCH & CONTROLLER

Transcription:

Version 2 Inline Relay (500W) Model o. W821 Instruction Manual Connect Series www.lightwaverf.house

EC DECARATIO OF COFORMITY Responsible Authority: ightwaverf PC, Innovation Campus Birmingham Faraday Wharf Holt Street Birmingham B7 4BB Tel: +44 (0)121 250 3625 Email: enquiries@lightwaverf.com Model umber(s): Description: Directives this equipment Complies with: JSJSW821 Inline Relay 2006/95/EC The ow Voltage Directive /A 2004/108/EEC The Electromagnetic Compatibility Directive 1999/5/EC R&TTE Directive 93/68/EEC CE Marking Directive Standards Applied in order to verify compliance Safety: BS E 60730-1: 2011 Health: R&TTE: E 301 489-1 V1.9.2: (2011-09), E 301 489-3 V1.4.1: (2002-08) E 300 220-1 V2.1.1: 2006, E 300 220-2 V2.1.2: 2007 EMC: E 301 489-1 V1.9.2: (2011-09), E 301 489-3 V1.4.1: (2002-08), E 55022: 2010, E 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A, E 61000-3-3: 2008, E61000-4-2: 2009, E 61000-4-3: 2006 +A1: 2008 +A2: 2010, E 61000-4-4: 2012, E 61000-4-5: 2006, E 61000-4-6: 2009, E 61000-4-11: 2004 For and on behalf of ightwaverf PC ---------------------------------------- ame J Shermer Position Managing Director

Get Started How do I get started? Please refer to the following installation and setup instructions that will guide you through the installation and setup process. What do I need? The relay is designed to remotely turn on/off lighting or power circuits (max 500W) or to control door, window or curtain openers. You must understand how your devices need to be wired and how to safely turn off the electricity supply. You will also need suitable electrical screwdrivers. Help video & further guidance For additional guidance, and to watch a video that will help guide you through the installation process, please visit the support section on www.lightwaverf.com

Installation Overview Power ED. When illuminated the relay is powered. On/off & linking button. Fuse compartment. Mounting hole. Wiring terminals. Screw cover. IMPORTAT: All ightwaverf products can be legally DIY installed in your own home; however, if in doubt, always consult a qualified electrician or heating engineer. It is important to install this product in accordance with the following instructions. Failure to do so may void your warranty.

Installation Wiring terminals Switched live 1 Common Switched ive eutral live 2 Switching terminals. Volts free OR mains 230V Mains power in The Inline relay requires mains power to operate. It can be used to provide up to 500W of mains powered switching OR separate volts free switching for circuits not requiring additional mains power. The relay latches between three positions: switched live 1, switched live 2 and a neutral position (not connected). IMPORTAT: The Inline relay is not designed to be left exposed once it is installed, as live mains wiring is connected to the terminals. Ensure that the device is mounted securely in a suitable housing. If conducting an insulation resistance test, all ightwaverf products must be disconnected from the mains, or damage will occur.

Installation Wiring the relay 1. IMPORTAT: Turn off the mains electrical supply. 2. Connect the live and neutral terminals, as shown in the diagram, to provide power to the relay. When the green ED is illuminated, the relay is connected to mains power. OTE: Even if switching a low voltage or non-mains circuit, the relay must always have mains power connected to the live and neutral terminals for it to be able to function. Relay terminals ive wire eutral wire Connecting to a circuit volts free Use this configuration to switch one or two circuits that do not require mains power to be provided from the live and 1. Connect the incoming live wire from the low voltage circuit to the common (com) terminal as shown in the diagram. live wire Mains power to relay

Installation 2. Connect the outgoing wire load to the leftmost load terminals ( ) as shown in the diagram. This is the wire that will be collected to the load (i.e. device to be switched or lamp). The relay now has 2 positions - on and off. The diagrams below show the on and off positions if a live were to be connected to the common and load to the leftmost load terminal. switched live (to device) live wire Mains power to relay On Position - circuit connected Off Position - circuit disconnected IMPORTAT: When the relay is operated remotely via RF, it is always the lefthand load terminal that will be connected when the on button is pressed. Therefore, if the circuit is wired as shown, pressing on using an RF remote will turn on the circuit, and off will disconnect it.

Installation Switching between two s If a second load wire connected to another circuit is attached to the second switched live terminal (see diagram), the relay can be used to switch between two circuits. In addition to the on and off positions, there is also a stop position which breaks contact with both of the right and lefthand circuits. switched live 1 (to device) live wire switched live 2 (to device) Position 1 - circuit 1 connected Position 2 - circuit 2 connected Stop Position (no circuit connected)

Installation OTE: A standard handheld or other ightwaverf remote control will only be able to utilise the on and off commands to switch between circuits but OT use the stop command, as it does not include this function. To operate the stop command you will need a ightwaverf On/Off/Stop Switch which includes on/off (open/close) and stop commands OR the ightwaverf App (requires ightwave ink). If you are using the App, you must slect the device as open/close during linking process (see in-app help). This will give you the stop command as well as on/off (open/close) when you come to operate the device from the smartphone. Curtains, Blinds and Doors Because of the stop command feature, the relay can be used to operate a device that requires an on/off (or open/close) function AD a stop (or pause) function, such as blinds, curtains and doors. In this case, as before, the incoming live wire will be connected to the com terminal, and there will be two separate outgoing load wires each connected to the separate switched live (or load) terminals (see diagram on the next page).

Installation switched live 1 (to device) live wire switched live 2 (to device) OTE: Because of the extra stop command, a ightwaverf On /off/stop Switch or the ightwaverf App and ightwave ink will be required to operate this setup. Connecting the Inline Relay to a circuit requiring mains power switched live 1 (to device) live wire Mains live eutral from device Mains neutral If the relay is being used to control (interupt) a mains powered circuit (max 500W load), then power must be taken from the relay s main live terminal via a jumper connection to the common terminal (see diagram). The neutral terminal must now also accommodate an incoming and outgoing connection to the mains circuit.

Device setup inking the relay to the App / controllers OTE: This procedure applies to the ightwaverf Smartphone and Web App and all ightwaverf controllers (e.g. Handheld Remote or Mood Controller). ightwaverf relays each have 6 unique memory slots which means they can link with up to 6 ightwaverf controllers in total. If you are using a smartphone/tablet/pc to control the relay via the ightwave ink, this will always count as OE controller and take up one memory slot even if you are using multiple smartphones/tablets. 1. On the relay, press and hold down the linking button until the ED flashes then release it. The relay is now in linking mode. inking button 2. Using the ightwaverf Smartphone App, press the connect button (the App instructions will guide you through this). If using another controller press the button that you intend to link. The blue light on the relay will flash more quickly to confirm that the App/controller is now linked.

Device setup OTE: inking mode lasts for 12 seconds; if no signal is received from a controller during this time then the socket will automatically exit linking mode without linking the device. If, when expecting a quick flashing ED to confirm pairing, a slow flash is received instead, then the relay memory is FU and no further remotes may be linked with it unless one of the existing remotes is unpaired first (see below). Unlinking controllers and clearing the Inline Relay memory Removing a single device: 1. On the relay, press and hold down the linking button until the ED flashes alternately, and then release it. That relay is now in linking mode. inking button 2. Using a ightwaverf controller, Smartphone or Web App, press the button intended to be unlinked; the ED light on the relay will flash to confirm that the App/controller is now unlinked.

Device setup Clearing the memory (will remove any linked App or Controllers): 1. On the relay, press and hold down the linking button until the ED flashes, and then release it. That relay is now in linking mode. inking button 2. Press and hold down the linking button again until the ED flashes more quickly, then tap (don t hold) the linking button a further time; the ED will flash slowly to confirm that the memory has been cleared. OTE: Reliable range of remote operation is around 15 metres indoors and up to 100m outdoors using the ightwave ink. This figure may vary depending upon the environment; very thick walls, bodies of water or large metal objects may interfere with radio range. If the distance between the transmitter and receiver is too great to achieve reliable operation, the ightwaverf Signal Booster may be used in conjunction with this product to increase the range. IMPORTAT: Inline relays should not be positioned within 30cm of one another, as their transmition signals may interfere and reduce the effective operational range.

Remote operation Remote operation Control with the ightwaverf App or On/off/stop Switch 1. Press the on / open button on the transmitter to turn the circuit on or switch between circuits. 2. Press the off / close button on the transmitter to turn the circuit off or switch between circuits. 3. Press the stop button to disconnect both circuits and cut power to connected devices. Control using an on/off transmitter such as the handheld remote 1. Press the on button on the transmitter to turn the circuit on or switch between circuits. 2. Press the off button on the transmitter to turn the circuit off or to switch between circuits.

Technical specification Specification RF frequency: 433.92 MHz Input rating: 220-240V~ 50Hz. Output rating: 500W Max. Dimensions: Width 68mm, Height 52mm, Depth 27mm Standby Energy Use: ess than 1W Warranty: 2 year standard warranty

Version 2 2 Quadrant Park Mundells Welwyn Garden City Herts A7 1FS 01707 386035 www.lightwaverf.house