Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Similar documents
ORIGINAL CABLE PLATES

Home Theater Page 9. Rough-In Hole Saw Plate /4 Hole Saw Plate Flexible Split Plate Décor Brush Plate...

Bluetooth Audio Receiver with USB Charging Port Manual 50002

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

High Performance Sound Pick-up Microphone Kits

Power and protection for your rackmount and cabinet equipment.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Since 1998, DataComm Electronics has been pioneering smart, innovative solutions for

Monochrome Camera. Features. User manual

INSTALLATION INSTRUCTIONS

Big button Speakerphone MODEL: FC-8814

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

User Manual WT-171LM / S

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

WS must be used in a temperature controlled place. It is compliant to ETS Class T

Surge Protection (TVSS)

Video Surveillance System with 2 Indoor/Outdoor Night Vision Cameras

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

E1135C PDU and Pod Upgrade Procedure

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

EMS Electrical Management System

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Progressive Industries, Inc. EMS Electrical Management System

FUTURE CALL USER MANUAL PICTURE PHONE WITH SPEAKERPHONE MODEL: FC-1007 SP / PD

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

Lighting PowerPincher Installation Instructions

Protect It! 8-Outlet Industrial Safety Surge Protector, 25-ft. Cord, 3900 Joules, Cord Wrap, Hang Holes

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

SAVE THESE INSTRUCTIONS

CAUTION READ CAREFULLY

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

TRC-190 User s Manual

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

DECOFLEX WIREFREE RTS SWITCH

Basketball Shot Clock Set LX2180 Manual

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Always "On" UPS Systems Inc. USER MANUAL

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

User Manual Color Door Camera

Model HM-535 Power Supply Installation and Service Instructions

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613

XBR V4 INSTALLATION AND USER GUIDE

Arca LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Customer: Date: Project: Qty: Type: ACL ACL. R2 Type II Distribution.

SUBWOOFER SYSTEM YST-MSW10

2.4 GHz WIRELESS B&W VIDEO SECURITY SYSTEM MODEL WL5230

M250 (M LL) Safety

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Before you get started

KCM H Megapixel IP D/N Hemispheric Camer a with Advanced WDR (DC 12V / PoE) Hardware Manual. Ver. 2013/09/09

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Eco-Surge 12-Outlet Home/Business Theater Surge Protector, 10-ft. Cord, 3600 Joules - Accommodates 8 Transformers

VOICE-ACTIVATED INTERCOM SYSTEM

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

AutoScan to MultiScan Replacement Kit

The PST-6. Owners Manual 1

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

PS/IO Circuit Board Retrofit

LTC 5121, LTC 5141 Series 2- and 4-Position Economical Sequential Switcher

B MP. 360 Weather-Proof Mini Dome. Hardware Manual

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

TRC-190 User s Manual

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

EMS-LCHW30 & EMS-LCHW50

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

B&W RearView Camera Installation & Operation

diode led VALENT X SPECIFICATION SHEET 24VDC OVERVIEW FEATURES & BENEFITS COMPATIBLE CHROMAPATH CHANNELS

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

M215 (M215-60) Safety

Thank you for your purchase of the Supa-Charger! Features Include:

Additional Help For additional installation instructions and videos, please visit our website at What s Included

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

Specifications, Installation, and Operating Instructions

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

RTT98 VINTAGE TURNTABLE

LED Maintenance Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

SSE34 Series. For more exciting new products please visit our website: Australia:

Universal Docking Station with 2.4GHz Wireless Speakers for iphone/ipod

CAUTION READ CAREFULLY

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Emery County Senior Center Green River 06/07

Installation Instructions & User Manual

Copyright Black Box Corporation. All rights reserved.

A Creative Light & Sound Company

Transcription:

Instruction / Installation Sheet DataComm Electronics 45-0024-WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725 770.662.8205 Parts Included: 1. Recessed Low Voltage Mid-Size Plate with Duplex Receptacle 2. Recessed Low Voltage Cable Plate with Straight Blade Inlet 3. Two (2) Electrical Outlet Boxes Four (4) Screws per Outlet Box 4. 15 Amp/125 Volt Tamper Resistant Duplex Receptacle 5. Three (3) Wire Nuts 6. 6ft. 16/2 with Ground Cord Set with 360 o Rotating Head Tools Needed: 1. Drywall Saw 2. 6 Ft. Tape Measure 3. Pencil 4. Screwdriver Use the Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet to install power and low voltage cables behind your flat panel TV, amplifier or other audio and video devices to your equipment room or at the location of your head end equipment (see Figures 1 & 2). Figure 1 Front View Figure 2 Back View IMPORTANT INSTRUCTIONS: Use the local electrical code approved installation when installing this product. The electrical parts in this kit are designed to be used only as a kit and none of these electrical parts are designed to be used individually. This product is not designed to be part of your home or a commercial building s electrical wiring system. This installation is only energized (electrically active) when the supplied 6 ft. cord is plugged into the recessed straight blade inlet located on the recessed low voltage cable plate and the straight blade end of the 6 ft. cord is plugged into either your surge protector or wall receptacle. If you are not familiar with home wiring systems, please call a qualified electrician to install this product. IMPORTANT INSTRUCTIONS: This product is designed for retrofit work only because the electrical outlet box cannot be attached to a stud. Installation Instructions for Retrofit Only: Select the location of your flat panel TV mounting bracket. Now select the location for both cable plates for the Recessed Pro- Power Kit with Duplex Receptacle and Straight Blade Inlet. Page 1 of 4 9/21/12

Installation / Instruction Sheet 45-0024-WH (Continued) Installation Instructions for the Top Plate with Duplex Receptacle: Fig. 1 Figure 1 Top view - shows needed space between the drywall and the studs. Receptacle side of the Mid-Size Plate should be 3 from the stud but no more than 5 (review picture carefully). Fig. 2 Figure 2 Using the template supplied (see page 3 of instruction sheet), trace the opening needed. Using a drywall saw, cut a hole in the drywall the size of the template. See Figure 1 before tracing your opening. Remember, the plates are designed to be mounted between the studs. Fig. 3 Figure 3 Run the 12/2 or 14/2 w/ground UL approved electrical building wire (not included in kit) from the top opening to the bottom opening and connect the Recessed Pro-Power Kit Cable Plate with Duplex Receptacle to the Recessed Cable Plate with Straight Blade Inlet. Make sure the piece of wire is long enough to allow for easy installation of the receptacles. Remember the Pro-Power Installation Kit is not part of your home s electrical wiring system. Pull the electrical building wire through a hole in the top cable plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 4 Figure 4 Now pull the other end of the building wire through a hole in the bottom plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box Fig. 5 Figure 5 Using the supplied duplex receptacle, connect the hot line (black) wire to the brass colored terminal or screw and the neutral (white) wire to the silver colored terminal or screw. Be sure to connect the grounding (green) or bare grounding wire to the green colored terminal screw. For shock protection, this UR, UL recognized component receptacle must be properly grounded. Caution use copper wire only with this receptacle. Once you have wired the receptacle, screw the receptacle into the electrical outlet box until the receptacle is firmly secured. Fig. 6 Figure 6 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Mid-Size Plate with Duplex Receptacle. Fig. 7 Figure 7 Important: Before installing the Recessed Mid-Size Plate with Duplex Receptacle into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the bottom of the Recessed Mid-Size Plate with Duplex Receptacle and slowly slide the plate into the opening. Swing the top of the plate into position until the entire Mid-Size Plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Page 2 of 4 9/21/12

Installation / Instruction Sheet 45-0024-WH (Continued) Installation Instructions for the Bottom Cable Plate with Straight Blade Inlet: Fig. 8 Figure 8 Wire the Cable Plate with Straight Blade Inlet to the 12/2 w/ground or 14/2 w/ground UL approved electrical building wire. Connect the hot line (black) wire to the black wire and the neutral (white) wire to the white wire on the straight blade inlet. Be sure to connect the grounding (green) or bare grounding wire to the green wire on the straight blade inlet. Make sure the three wire nuts are fastened tightly. Fig. 9 Figure 9 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Cable Plate with Straight Blade Inlet. Fig. 10 Figure 10 Important: Before installing the Plate with Straight Blade Inlet into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the side of the Plate with Straight Blade Inlet and slowly slide the plate into the opening. Swing the right side of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Fig. 11 Figure 11 Your new 45-0024-WH Recessed Pro Power Kit with Duplex Receptacle and Straight Blade Inlet is now installed and ready for the flat panel TV mount to be installed. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instruction. Fig. 12 Figure 12 Hang your flat panel TV on the mounting bracket and plug your TV into the top Cable Plate with Duplex Receptacle. Now plug your cord set into bottom Cable Plate with Straight Blade Inlet. Then plug the male end of the cord set into a nearby wall receptacle. WARNING DataComm Electronics products shall be installed and used only as indicated in DataComm Electronics product instruction sheets. Instruction sheets are available online at. CAUTION For shock protection, this device must be properly grounded. Use copper wire only with this device. IMPORTANT INSTRUCTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. SAVE THESE INSTRUCTIONS. This product is patent protected by U.S. Patent numbers D553475, D554475 and 7390964. RoHS Compliant. Page 3 of 4 9/21/12

Installation / Instruction Sheet 45-0024-WH (Continued) ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT 6-1/2 TEMPLATE 4-1/2 Recessed Low Voltage Mid-Size Plate with Duplex Receptacle ACTUAL SIZE CUT ALONG DOTTED LINE 4-11/16 TEMPLATE 4.0 Recessed Low Voltage Cable Plate with Straight Blade Inlet ACTUAL SIZE CUT ALONG DOTTED LINE Page 4 of 4 9/21/12

Instruction / Installation Sheet DataComm Electronics 45-0028-WH Recessed Pro-Power Kit with Duplex Surge Suppressor DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725 770.662.8205 Parts Included: 1. Recessed Low Voltage Mid-Size Plate with Duplex Surge Receptacle 2. Recessed Low Voltage Cable Plate with Straight Blade Inlet 3. Two (2) Electrical Outlet Boxes Four (4) Screws per Outlet Box 4. 15 Amp/125 Volt Duplex Surge Receptacle 5. Three (3) Wire Nuts 6. 6ft. 16/2 with Ground Cord Set with 360 o Rotating Head Tools Needed: 1. Drywall Saw 2. 6 Ft. Tape Measure 3. Pencil 4. Screwdriver Use the Recessed Pro-Power Kit with Duplex Surge Suppressor to install power and low voltage cables behind your flat panel TV, amplifier or other audio and video devices to your equipment room or at the location of your head end equipment (see Figures 1 & 2). Figure 1 Front View Figure 2 Back View IMPORTANT INSTRUCTIONS: Use the local electrical code approved installation when installing this product. The electrical parts in this kit are designed to be used only as a kit and none of these electrical parts are designed to be used individually. This product is not designed to be part of your home or a commercial building s electrical wiring system. This installation is only energized (electrically active) when the supplied 6 ft. cord is plugged into the recessed straight blade inlet located on the recessed low voltage cable plate and the straight blade end of the 6 ft. cord is plugged into either your surge protector or wall receptacle. If you are not familiar with home wiring systems, please call a qualified electrician to install this product. IMPORTANT INSTRUCTIONS: This product is designed for retrofit work only because the electrical outlet box cannot be attached to a stud. This product is designed to alert you if you ever lose surge protection. The Surge Suppressor Receptacle is designed to provide protection against shortterm over-voltage conditions as well as from RFI (radio frequency interference). The Surge Suppressor cannot survive, or provide protection in the rare event of a direct lightning strike on the service power line. The Surge Suppressor alerts you to the failure of the surge protection component by means of an audible signal. If alarm sounds, device has received power surges in excess of its capacity and is no longer functioning as a surge protector. To shut off alarm, simply turn the Alarm Off screw on the front of the receptacle clockwise. Note: When alarm sounds and the Alarm Off screw is turn off, the receptacle still functions as a normal duplex receptacle without surge protection. Installation Instructions for Retrofit Only: Select the location of your flat panel TV mounting bracket. Now select the location for both the wall plates for the Recessed Pro-Power Kit with Duplex Surge Suppressor. Page 1 of 4 10/1/12

Installation / Instruction Sheet 45-0028-WH (Continued) Installation Instructions for the Top Plate with Duplex Surge Receptacle: Fig. 1 Figure 1 Top view - shows needed space between the drywall and the studs. Receptacle side of the Mid-Size Plate should be 3 from the stud but no more than 5 (review picture carefully). Fig. 2 Figure 2 Using the template supplied (see page 3 of instruction sheet), trace the opening needed. Using a drywall saw, cut a hole in the drywall the size of the template. See Figure 1 before tracing your opening. Remember, the plates are designed to be mounted between the studs. Fig. 3 Figure 3 Run the 14/2 w/ground UL approved electrical building wire (not included in kit) from the top opening to the bottom opening and connect the Cable Plate with Duplex Surge Receptacle to the Cable Plate with Straight Blade Inlet. Make sure the piece of wire is long enough to allow for easy installation of the receptacles. Remember the Recessed Pro-Power Kit with Duplex Surge Suppressor is not part of your home s electrical wiring system. Pull the electrical building wire through a hole in the top cable plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 4 Figure 4 Now pull the other end of the electrical building wire through a hole in the bottom plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 5 Figure 5 Using the supplied duplex surge receptacle, connect the hot line (black) wire to the brass colored terminal or screw and the neutral (white) wire to the silver colored terminal or screw. Be sure to connect the grounding (green) or bare grounding wire to the green colored terminal screw. For shock protection, this UR, UL recognized component receptacle must be properly grounded. Caution use copper wire only with this receptacle. Once you have wired the receptacle, screw the receptacle into the electrical outlet box until the receptacle is firmly secured. Fig. 6 Figure 6 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Mid-Size Plate with Duplex Surge Receptacle. Fig. 7 Figure 7 Stop: Important: Before installing the Recessed Mid-Size Plate with Duplex Surge Suppressor Receptacle into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the bottom of the Recessed Mid-Size Plate with Duplex Surge Receptacle and slowly slide the plate into the opening. Swing the top of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Page 2 of 4 10/1/12

Installation / Instruction Sheet 45-0028-WH (Continued) Installation Instructions for the Bottom Cable Plate with Straight Blade Inlet Fig. 8 Figure 8 Wire the Cable Plate with Straight Blade Inlet to the 14/2 w/ground UL approved electrical building wire. Connect the hot line (black) wire to the black wire and the neutral (white) wire to the white wire on the straight blade inlet. Be sure to connect the grounding (green) or bare grounding wire to the green wire on the straight blade inlet. Make sure the three wire nuts are fastened tightly. Fig. 9 Figure 9 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Cable Plate with Straight Blade Inlet. Fig. 10 Fig. 11 Figure 10 Important: Before installing the Plate with Straight Blade Inlet into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the side of the Plate with Straight Blade Inlet and slowly slide the plate into the opening. Swing the right side of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Figure 11 Your new Recessed Pro-Power Kit with Duplex Surge Suppressor is now installed and ready for the flat panel TV mount to be installed. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instruction. Fig. 12 Figure 12 Hang your flat panel TV on the mounting bracket and plug your TV into the top Cable Plate with Duplex Receptacle. Now plug your cord set into bottom Cable Plate with Straight Blade Inlet. Then plug the male end of the cord set into a nearby wall receptacle. Duplex Surge Receptacle Specifications Inside the Hubbell Surge Protection Receptacles are two 22mm square MOV s providing 240 joules /15000A of surge protection for each mode. Meets UL Standards 1449 3rd Edition and 498: CSA Certified. Damage-alert alarm sounds when surge protection is no longer functioning and keeps sounding until the muting screw is utilized or the receptacle is replaced. Power-on indicator light verifies instantly that power is available at the receptacle and the suppression circuit is fully functional; light off means power has been interrupted, flashing light indicates surge protections circuitry has been damaged. Replacement surge suppressors can be purchased from DataComm Electronics or an authorized Hubbell Wiring Device distributor. 2-Pole 3-Wire Grounded 60 Hz Total Maximum Surge Dissipation Maximum Surge Current Surge Protection Clamping Response Time 15A-125V 480 Joules 15,000 Amps Hot/Neutral, Hot/Ground, Neutral/Ground 1 Nanosecond WARNING DataComm Electronics products shall be installed and used only as indicated in DataComm Electronics product instruction sheets. Instruction sheets are available online at. CAUTION For shock protection, this device must be properly grounded. Use copper wire only with this device. IMPORTANT INSTRUCTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. SAVE THESE INSTRUCTIONS. This product is patent protected by U.S. Patent numbers D553475, D554475 and 7390964. RoHS Compliant. Page 3 of 4 10/1/12

Installation / Instruction Sheet 45-0028-WH (Continued) ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT 6-1/2 TEMPLATE 4-1/2 Recessed Low Voltage Mid-Size Plate with Duplex Surge Receptacle ACTUAL SIZE CUT ALONG DOTTED LINE 4-11/16 TEMPLATE 4.0 Recessed Low Voltage Cable Plate with Straight Blade Inlet ACTUAL SIZE CUT ALONG DOTTED LINE Page 4 of 4 10/1/12