Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06

Similar documents
Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type RZMO-A*

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20

Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32

Seals material: omit for NBR (mineral oil & water glycol) PE = FPM. Series number

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06

Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 4401 size 06 and 10

Servoproportional valves type DLHZO and DLKZOR

Proportional throttle cartridges type LIQZO-T*, 2-way with position transducer, ISO 7368 sizes from 16 to 50

Proportional 2-way throttle cartridges high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional directional valves type DHZO-TES and DKZOR-TES direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

Proportional electrohydraulic controls for PVPC pumps pressure-flow combined P/Q controls, analog or digital

High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 16 to 100

Digital electronic REB/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer

Proportional throttle cartridges type LIQZO-L*, 3-way high dynamics, with two position transducers, sizes from 25 to 80

Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 16 to 100, rugged design

Hydraulic Power Limitation. Real Time Fieldbus Reference. Enhanced Diagnostic. E-SW programming software. Set code (see note) Series number

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Proportional 2-way cartridges high performance rugged digital, with two position transducers, ISO 7368 sizes from 16 to 100

Servoproportional 3-way cartridges digital, with two position transducers, sizes from 25 to 80, rugged design

Analog or Digital 08E001 RI-* drivers

TWO CHANNELS REDUNDANT SAFETY ARCHITECTURE SINGLE CHANNEL NON-REDUNDANT SAFETY ARCHITECTURE

ISO cartridge valves type LID* Check function, ISO 7368 size from 16 to 100, high flow, Pmax 420 bar

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Expansion Module HZS 541-1S

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac

Temperature Switches

MINI MCR-SL-PT100-UI-200

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Magnetically Inductive Flowmeter

Digital electropneumatic Positioner for the integrated mounting on process control valves

Inclination sensors 2-dimensional, measuring range up to ±90

Digital electropneumatic Positioner for the integrated mounting on process control valves

ISOMETER isoev425/isoev425hc with coupling device AGH420

PC2004 PRESSURE CONTROLLER

Proportional controls for PVPC pumps analog pressure or flow, digital P/Q controls

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Control Head for the integrated mounting on process valves

P/N: AX Distribute your control functions directly onto the valve.

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Control Head for the integrated mounting on process valves

LFC Liquid Flow Controller

EC axial fan - HyBlade

ISOMETER isoev425 with coupling device AGH420

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

ISOMETER isopv with coupling device AGH-PV

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Flowtronic D 607 Series

InBin-P Pressure switches from 5 Pa Pa

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Manual Control Unit GFC 32

Fieldbus Gateway Type ME43

Compact universal controllers

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

TECHNICAL DATASHEET #TDAX023300

icountpd Online Particle Detector

Direct solenoid and solenoid pilot operated valves

EC centrifugal module - RadiPac

Flow. Flow. N/en

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Electronic Level Switch ENS 3000

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Mass Flow Meter (MFM) for Gases

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Two stage proportional directional valves high performance digital with two position transducers and positive spool overlap, rugged design

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No.

Inclination sensors 1-dimensional, measuring range

Products no longer available

MINI MCR-SL-CVS NC

E-STOP relays, safety gate monitors

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Electronic Control Unit RC

Linear Position Transducer HLT 1000-R2

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

TECHNICAL DATASHEET #TDAX023240

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

Digital electropneumatic positioner

Internal Buffer/Boiler Module HZS 534

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Distance and Position Sensors

MIC-2 MKII, Multi-instrument DATA SHEET

Digital electropneumatic positioner

M260 Load Cell Amplifiers

Installation Manual Series PWD 00A-400. Amplifier for Proportional Directional Control Valves. Bulletin HY M1/UK

Transcription:

www.atos.com Table F007-20/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics Main connector -BC / -BP Communication connector -PS Communication connector Screw for air bleeding MODEL CODE RZMO Proportional pressure relief valve size 06 A = without integral transducer AE = as A plus integral electronics AES = as A plus integral digital electronics Communication interfaces (only for AES): PS = Serial () BC = CANopen BP = PROFIBUS DP Configuration: 00 = regulation on port P, discharge in T Pressure range: 50 = 50 bar 00 = 00 bar 20 = 20 bar 35 = 35 bar 8 9 RZMO-AES-BC-00/* AES PS 00 / 35 / * ** / * Series number Syntethic fluids WG = water-glycol PE = phosphate ester Options for -A execution, see section : 6 = with 6 VDC coil instead of standard 2VDC coil 8 = with 8 VDC coil instead of standard 2VDC coil Electronics options for -AE execution, see section : I = current reference input (4 20 ma) Q = enable signal Electronics options for -AES execution, see section : Q = enable signal Z = adds double power supply, enable and fault signals (2 pin connector) RZMO are poppet type proportional pressure relief valves, direct operated without integral pressure transducer, which provide pressure regulation proportional to electronic reference signals. They operate in association with electronic drivers, see section, which supply the proportional valve with proper current to align valve regulation to the reference signal supplied to the electronic driver. They are available in different executions: -A, without integral pressure transducer. -AE, -AES, as -A plus analogue (AE) or digital (AES) integral electronics. The system pressure is controlled by the poppet, directly operated by the proportional solenoid and the spring. The integral electronics ensures factory presetting, fine functionality plus valve-tovalve interchangeability and simplified wiring and installation. The electronic main connector is fully interchangeable for -AE and -AES executions. Standard 7 pin connector is used for power supply, analog input reference and monitor signals. 2 pin connector is used for option /Z (AES). Following communication interfaces, are available for the -AES execution: standard -PS, Serial communication interface for configuration, monitoring and firmware updating through Atos PC software - always present optional -BC, CANopen interface optional -BP, PROFIBUS-DP interface The valves with -BC and -BP interfaces can be integrated into a fieldbus communication network and thus digitally operated by the machine control unit. The coils are fully plastic encapsulated (insulation class H), and the valves have antivibration, antishock and weather-proof features. Mounting surface: ISO 440, size 06 Max flow: 4 l/min Max pressure: 35 bar. () Serial interface always present, also for -BC and -BP options 2 ELECTRIC DRIVERS FOR RZMO Valve model -A -AE -AES Drivers model E-MI-AC-0F E-MI-AS-IR E-BM-AC-0F E-BM-AS-PS E-ME-AC-0F E-RP-AC-0F E-RI-AE E-RI-AES Data sheet G00 G020 G025 G030 G035 G00 G0 G5 Note: for power supply and communication connector see section 5 F007

3 HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 C) Hydraulic symbols Valve model Max regulated pressure (Q = l/min) 50 RZMO-A 00 RZMO-AE RZMO-AES 20 35 Min. regulated pressure (Q = l/min),8 2,5 3,5 Max. pressure at port P 35 Max. pressure at port T 20 Max. flow Response time 0-00% step signal (depending on installation) [l/min] [ms] 4 70 Hysteresis [% of the max pressure],5 Linearity [% of the max pressure] 3 Repeatability [% of the max pressure] 2 Above performance data refer to valves coupled with Atos electronic drivers, see section. 4 GENERAL NOTES RZMO proportional valves are CE marked according to the applicable Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive). Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes supplied with relevant components. The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions, like to switch-/off the machine s safety components, as prescribed by the European standards (Safety requirements of fluid technology systems and components-hydraulics, EN-982). 5 OPTIS FOR -A EXECUTI 5. Option /6 6 VDC coil instead of standard 2 VDC, to be used in case of power supply 2 VDC 5.2 Option /8 8 VDC coil instead of standard 2 VDC, to be used with electronic drivers not supplied by Atos 6 CNECTIS FOR -A EXECUTI PIN 2 3 SOLENOID POWER SUPPLY CNECTOR Signal description SUPPLY SUPPLY GND 2 3 7 ANALOG INTEGRAL DRIVERS -AE - OPTIS Standard driver execution provides on the 7 pin main connector: Power supply - 24VDC must be appropriately stabilized or rectified and filtered; a 2,5 A safety fuse is required in series to the driver power supply. Apply at least a 0000 μf/40 V capacitance to single phase rectifiers or a 4700 μf/40 V capacitance to three phase rectifiers Reference input signal - analog differential input with 0 +0VDC nominal range (pin D,E), proportional to desired coil current Monitor output signal - analog output signal proportional to the actual valve s coil current (V monitor = A coil current) Following options are available to adapt standard execution to special application requirements: 7. Option /I It provides the 4 20 ma current reference signal instead of the standard 0 +0 VDC. Monitor output signal is still the standard 0 +0VDC. It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by electrical noise; the valve functioning is disabled in case of reference signal cable breakage. 7.2 Option /Q It provides the possibility to enable or disable the valve functioning without cutting the power supply (the valve functioning is disabled but the driver current output stage is still active). To enable the driver supply a 24VDC on the enable input signal. 7.3 Possible combined option: /IQ

8 ANALOG INTEGRAL DRIVERS -AE - MAIN FUNCTIS AND ELECTRIC CNECTIS MAIN CNECTOR 7 PIN - STANDARD SCALE BIAS RAMPS REGULATIS AND SWITCHES (remove the rear cover) Selector SW Dither frequency SW SW2 SW3 SW4 [Hz] 00 30 60 200 (Standard) 230 270 300 380 430 470 500 The dither frequency is factory preset at 200 Hz and its regulation may be adjusted after contact with Atos technical department B: S: RU: RD: SW: positive bias adjust positive scale adjust ramp for increasing reference signal ramp for decreasing reference signal dither frequency selector (see table beside) SW RD RU B S OFF 8. ELECTRIC CNECTIS - 7 PIN MAIN CNECTORS PIN SIGNAL TECHNICAL SPECIFICATIS NOTES A V+ Power supply 24 VDC for solenoid power stage and driver logic Input - power supply B V0 Power supply 0 VDC for solenoid power stage and driver logic Gnd - power supply C () AGND Ground - signal zero for MITOR signal Gnd - analog signal ENABLE Enable (24 VDC) or disable (0 VDC) the driver (for /Q option) Input - on/off signal D INPUT+ Reference analog input: 0 +0 VDC maximum range (4 20 ma for /I option) Input - analog signal E INPUT - Normal working range 0 +0 VDC (4 20 ma for /I option) F MITOR Monitor analog output: 0 +5 VDC maximum range; V = A Output - analog signal G EARTH Internally connected to the driver housing Note: () with /Q option ENABLE signal replaces AGND on pin C; MITOR signal is reffered to pin B. A minimum time of 60ms to 60ms have be considered between the driver energizing with the 24 VDC power supply and when the valve is ready to operate. During this time the current to the valve coils is switched to zero 9 DIGITAL INTEGRAL DRIVERS -AES - OPTIS Standard driver execution provides on the 7 pin main connector: Power supply - 24VDC must be appropriately stabilized or rectified and filtered; a 2,5 A safety fuse is required in series to each driver power supply Apply at least a 0000 μf/40 V capacitance to single phase rectifiers or a 4700 μf/40 V capacitance to three phase rectifiers. Reference input signal Monitor output signal - analog differential input with 0 +0 VDC nominal range (pin D,E), proportional to desired coil current (4 20 ma with cable break detection, ± 0 ma, ± 20 ma or 0 20 ma software selectable) - analog output signal proportional to the actual valve s coil current (V monior = A coil current) Following options are available to adapt standard execution to special application requirements: 9. Option /Q To enable the driver, supply 24Vdc on pin C referred to pin B: when the enable signal is set to zero the valve status is software selectable, by factory default the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active. For the complete list of selectable status, see tab. G5. 9.2 Option /Z It provides, on the 2 pin main connector, the following additional features: Logic power supply Separated power supply for the solenoid (pin, 2) and for the digital electronic circuits (pin 9, 0). Cutting solenoid power supply allows to interrupt the valve functioning but keeping energized the digital electronics thus avoiding fault conditions of the machine fieldbus controller. This condition allows to realize safety systems in compliance with European Norms EN3849- (ex EN954-). Enable Input Signal To enable the driver, supply 24Vdc on pin 3 referred to pin 2: when the enable signal is set to zero the valve status is software selectable, by factory default the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active. For the complete list of selectable status, see tab. G5. Fault Output Signal Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4 20mA input, etc.). Fault presence corresponds to 0 VDC, normal working corresponds to 24VDC (pin referred to pin 2): Fault status is not affected by the Enable input signal. F007

0 DIGITAL INTEGRAL DRIVERS -AES - MAIN FUNCTIS AND ELECTRIC CNECTIS MAIN CNECTOR 7 PIN - STANDARD COMMUNICATI CNECTOR 5 PIN PROFIBUS DP (-BP) 5 PIN CANopen (-BC) SCALE LINEARIZATI BIAS RAMPS 2 PIN - OPTI /Z 5 PIN Serial (-PS) 0. ELECTRIC CNECTIS - 7 & 2 PIN MAIN CNECTORS Standard /Z option 7pin 2pin SIGNAL TECHNICAL SPECIFICATIS NOTES A V+ Power supply 24 VDC for solenoid power stage (and for driver logic on 7 pin connection) Input - power supply B 2 V0 Power supply 0 VDC for solenoid power stage (and for driver logic on 7 pin connection) Gnd - power supply D 4 INPUT+ Reference analog input: ±0 VDC / ± 20 ma maximum range software selectable, see 9 E - INPUT - Default setting 0 +0 VDC differential input Input - analog signal /Z option: common mode INPUT+ referred to AGND 3 ENABLE Enable (24 VDC) or disable (0 VDC) the driver Input - on/off signal C Ground - signal zero for MITOR signal 5 AGND signal zero for INPUT+ signal ( only for /Z option) Gnd - analog signal F 6 MITOR Monitor analog output: 0 +5 VDC maximum range; V = A Output - analog signal Note: - 7 NC do not connect - 8 NC do not connect - 9 VL+ Power supply 24 VDC for driver logic Input - power supply - 0 VL0 Power supply 0 VDC for driver logic Gnd - power supply - FAULT Fault (0 VDC) or normal working (24 VDC) Output - on/off signal G PE EARTH Internally connected to the driver housing A minimum time of 270 to 340 ms have be considered between the driver energizing with the 24VDC power supply and when the valve is ready to operate. During this time the current to the valve coils is switched to zero. 0.2 ELECTRIC CNECTIS - 5 PIN COMMUNICATI CNECTORS -PS Serial -BC CANopen -BP PROFIBUS DP PIN SIGNAL TECHNICAL SPECIFICATI SIGNAL TECHNICAL SPECIFICATI SIGNAL TECHNICAL SPECIFICATI NC do not connect CAN_SHLD Shield +5V for termination 2 NC do not connect NC do not connect LINE-A Bus line (high) 3 RS_GND Signal zero data line CAN_GND Signal zero data line DGND data line and termination Signal zero 4 RS_RX Valves receiving data line CAN_H Bus line (high) LINE-B Bus line (low) 5 RS_TX Valves transmitting data line CAN_L Bus line (low) SHIELD do not connect SOFTWARE TOOLS The driver configuration and parameters can be easily set with the Atos E-SW programming software, available in three different versions according to the driver s communication execution: E-SW-PS (Serial), E-SW-BC (CANopen) and E-SW-BP (PROFIBUS DP). Programming software E-SW-BC and E-SW- BP, for BC and BP drivers, can be also used to modify the valve s parameterization through the serial communication interface, without disconnecting the valve from the machine s bus line. For a more detailed description of software interface, PC requirements, adapters, cables and terminators, please refer to technical table G500. Programming software, must be ordered separately: E-SW-* (mandatory - first supply) = Dvd including E-SW-* software installer and operator manuals; it allows the registration to Atos digital service E-SW-*-N (optional - next supplies) = as above but not allowing the registration to Atos digital service On first supply of the E-SW-* software, it is required to apply for the registration in the Atos download area: www.download.atos.com. Once the registration is completed, the password will be sent by email. The software remains active for 0 days from the installation date and then it stops until the user inputs his password. With the password you can also download, in your personal area, the latest releases of the Atos software, manuals, drivers and configuration files. 2 MAIN CHARACTERISTICS OF PROPORTIAL RELIEF VALVES Assembly position Any position Subplate surface finishing Roughness index, flatness ratio 0,0/00 (ISO 0) Ambient temperature -20 C +70 C for -A execution; -20 C +60 C for -AE and -AES executions Fluid Hydraulic oil as per DIN 5524... 535 for other fluids see section Recommended viscosity 5 00 mm 2 /s at 40 C (ISO VG 5 00) Fluid contamination class ISO 8/5 achieved with in line filters of 0 μm and β0 _>75 (recommended) Fluid temperature -20 C +60 C (standard and /WG seals) -20 C +80 C (/PE seals) Coil resistance R at 20 C 3 3.3 Ω for standard 2 VDC coil; 2 2,2 Ω for 6 VDC coil; 3 3,4 Ω for 8 VDC coil Max solenoid current 2,6 A for standard 2 VDC coil; 3,25 A for 6 VDC coil;,5 A for 8 VDC coil Max power 40 Watt Protection degree (CEI EN-60529) IP65 for -A execution; IP67 for -AE and AES executions Duty factor Continuous rating (ED=00%)

3 DIAGRAMS (based on mineral oil ISO VG 46 at 50 C) 3. Regulation diagrams with flow rate Q = l/min = RZMO-A, RZMO-AE, RZMO-AES Note: The presence of counter pressure at port T can affect the effective pressure regulation. Pressure at port P [% of the max.] Reference signal [% of the max] 3.2 Pressure/flow diagrams with reference signal set at Q = l/min 2 = RZMO-A, RZMO-AE, RZMO-AES Pressure at port P 2 Flow [l/min] 3.3 Min. pressure/flow diagrams with zero reference signal 3 = RZMO-*-00/50 4 = RZMO-*-00/00 5 = RZMO-*-00/20 6 = RZMO-*-00/35 Min. regulated pressure 4 3 Min. regulated pressure 6 5 Flow [l/min] Flow [l/min] 3.4 Dynamic response The response times in section have to be considered as average values. The pressure variation in consequence of a modification of the reference input signal to the valve is affected by the stiffness of the hydraulic circuit: greater is the stiffness of the circuit, faster is the dynamic response. F007

4 INSTALLATI DIMENSIS [mm] ISO 440: 2005 Mounting surface: 440-03-02-0-05 (see table P005) (without ports A and B) Fastening bolts: 4 socket head screws M5X50 class 2.9 Tightening torque = 8 Nm Seals: 2 OR 08 Ports P, T: Ø = 5 mm SP-666 RZMO-A Mass:,8 Kg SP-ZH-7P or SP-ZM-7P RZMO-AE Mass: 2,5 Kg SP-ZH-7P or SP-ZM-7P RZMO-AES-* Mass: 2,7 Kg = screw for air bleeding Dotted line = 2 pin connector SP-ZH-2P for option /Z -PS communication interface, SP-ZH-5P connector -BP communication interface, SP-ZH-5P/BP connector -BC communication interface, SP-ZH-5P connector 5 MODEL CODES OF POWER SUPPLY AND COMMUNICATI CNECTORS (to be ordered separately) VALVE VERSI -A -AE, -AES -AES/Z -Serial (-PS) or CANopen (-BC) PROFIBUS DP (-BP) CNECTOR CODE SP-666 SP-ZH-7P SP-ZM-7P SP-ZH-2P SP-ZH-5P SP-ZH-5P/BP PROTECTI DEGREE IP65 IP67 IP67 IP67 IP67 IP67 DATA SHEET K500 G0, G5, K500 G5, K500 connectors supplyed with the valve 07/