Feeder/ Motor Protection Relay VAMP 40

Similar documents
Feeder/Motor Manager Series VAMP 230 VAMP 245 VAMP 255 VAMP 257

Protection relays.

Line manager VAMP 259 for distance and line differential protection

VAMP 50 series. with native IEC and arc flash protection

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

VAMP 57. Multipurpose feeder and motor protection relay. m.vamp.fi

Feeder protection relay SPAA 121 C. Product Guide

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

VAMP 259. Line manager for distance and line differential protection. Protection MAIN CHARACTERISTICS

VAMP 50, VAMP 51, VAMP 52, VAMP 55. Protection relays with native IEC and arc flash protection

Comprehensive motor protection and control from VAMP

Earth-fault Relay SPAJ 110 C. Product Guide

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

MIC-2 MKII, Multi-instrument DATA SHEET

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Residual overvoltage relay

Bus Bar Protection Relay B-PRO 4000

Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Feeder Protection Relay REF 610. Product Guide

NPW800R RETROFITTING. Power and Volatge Protection Relay

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

Products Portfolio. Pole mounted Vacuum Recloser

Feeder protection relay

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

MIC-2 Multi-instrument DATA SHEET

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

RT12-240V/2.4kW Rectifier Specification

Voltage Transducer UMT516 / MT516

GE Multilin 350 Feeder Protection Relay Specifications

FP-5000 Feeder Protection

Feeder protection relay SPAA 341 C. Product Guide

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

TFS 2100 Traveling Wave Fault Location System

Transformer Protection Relay

Arc protection relay. Features Three-phase overcurrent function. Application

GRD110 FEATURES APPLICATION

Communication Gateway COM 610. Product Guide

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Multifunction Transducer MT440

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

Synchro-check relay. Application

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

VAMP 50 series. with native IEC and arc flash protection. Protection

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

SM100. On-Line Switchgear Condition Monitoring

RT4B-110V/12A RECTIFIER

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

RT4F-110V/25A RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

MiCOM P122C Time-Overcurrent Protection

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

VIP 40/45 VIP 400/410

RT4F-48V/50A-WAC RECTIFIER

SACE Emax 2 Specification guide

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

ABB Digital medium-voltage switchgear

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

DRTS 33. The new generation of advanced three phase relay test set

Protect induction and synchronous motors with one relay.

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Contact protection relay

Content REF615 Technical Presentation

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Scout-S Station Controller

MINER-S Station Controller

For Transmission, Distribution and Machinery protection.

TM221CE24R controller M IO relay Ethernet

A low-cost, economical solution for distribution feeder protection

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Protection Relays PHASE & RESIDUAL OVERCURRENT

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RT9-48V/1.4kW Rectifier Specification

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

TM221M16R controller M IO relay

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

WM20. Power analyzer for three-phase systems. Benefits. Description

Siprotec 7ST61 / 7ST63

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

Transcription:

Feeder/ Motor Protection Relay

Feeder/motor protection relay Main characteristics Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable feeders, motor feeders including large motors, capacitor banks and reactors. Comprehensive measurements Wide range of measurement functions including phase and residual currents, residual or line or phase voltage, frequency, current unbalance, maximum demand, negative phase sequence current, active and reactive power and energyc according to the primary connection. Power quality assessment Power quality assessment and analysis including supervision of harmonics up to the 5th order, THD of currents and voltage. Ultra-fast arc flash protection Unique integrated arc flash protection functionality for enhanced safety of switchgear and substations to people and property. Extensive communication Large number of supported communication protocols including IEC 687-5-, IEC 687-5-, Modbus TCP, Modbus RTU, Profibus DP, TCP/IP, SPA-bus, DNP. and IEC 685. Easy handling and management Easy commissioning, configuration and operation of the relays supported by the straight-forward VAMPSET relay management software. Limited depth dimension The slim casing gives a possibility to install this relay to the secondary equipment compartment which has limited space. Universal auxiliary power supply The wide auxiliary power supply, 9-265 V ac/dc, 5/6 Hz makes this relay suitable to every installation. Application The protection relays of the VAMP Series are used for the selective protection of overhead line feeders, cable feeders, motor feeders, capacitor banks, reactors and busbars in power system distribution substations, power plants, industrial power systems, marine and offshore installations. Besides a comprehensive range of standard protection functions the VAMP series also offers measurement, primary circuit monitoring and communication functionality. A unique feature of the VAMP relays is the arc fault protection system integrable into the relays. The extremely fast arc fault protection option adds a new dimension to the total safety of the installation and the reliability of the protection system. Customer specific configuration is obtained by programming the device using keypad or VAMPSET software. After a network fault the relays support a subsequent fault analysis by providing event sequence (2 events) recordings, fault value registration and disturbance recorder capability. All this functionality and a comprehensive set of supported communication protocols make the VAMP Series an outstanding product portfolio on the world market of power system protection and control equipment. 2

Measurement and monitoring functions The offers a complete set of measurement functions to replace the conventional metering functions of traditional switchgear and control gear installations. The measurement functions cover currents, residual or phase to phase or phase to earth voltages. The voltage measurement vary according to the connected voltage that is either residual voltage ( U ), phase to earth voltage ( UL ) or phase to phase voltage ( U2 ) connection. The measured information can be read via the communication bus or display. Besides the measurement functions also encompasses a set of system supervision functions. All current circuits are continuously supervised, as are the trip circuits from the relay to the circuit breaker trip coils. The wear and tear of the circuit breaker is also continuously monitored providing an alarm when the circuit breaker needs maintenance. Power quality assessment The power quality of electrical networks has become increasingly important in modern society. Sophisticated loads, such as computers and automation systems, require an uninterrupted supply of clean electricity. The feeder and motor protection relay is provided with integrated power quality measuring and analyzing functions, which help catching possible variations in the quality of the distributed power. The relay supervises harmonics of phase currents and one voltage from the 2nd to 5th order and the THD (Total Harmonic Distortion). Many functions in modern society rely heavily on electric energy and there-fore the quality of the energy supply is gaining increased importance Functionality Protection functions IEEE no IEC symbol Function name 5/5 I>, I>>, I>>> Overcurrent protection IEC, IEEE 5N/5N, >, >>, >>> Earth fault protection programmable 67N I ϕ>, I ϕ>> Directional earth fault protection ( curves 67NT IT> Intermittent transient earth fault protection ( 87N I REF Restricted earth fault protection 46R I 2/ Broken line protection 46 I 2> Current unbalance protection 47 I 2>> Incorrect phase sequence protection 48 Ist> Stall protection 66 N> Frequent start protection 7 I< Undercurrent protection 49 T> Thermal overload protection 2 P Reverse power, phase 59C Uc> Capacitor overvoltage protection 59N U >, U >> Zero sequence voltage protection ( 59 U>, U>>, U>>> Overvoltage protection, -phase (2 27 U<, U<<, U<<< Undervoltage protection, -phase (2 68 I 2f > Inrush and cold load detection 79 Auto reclose function 5BF CBFP Circuit-breaker failure protection 5ARC ArcI> Arc fault protection ( 5NARC Arc, ArcI 2> Arc fault protection ( Capacitor bank unbalance protection 86 Latched trip 99 Programmable stages 8 Measurement and monitoring functions I Three-phase current I Neutral current I 2 Current unbalance I L Average and maximum demand current U Residual voltage U L / U 2 Phase to earth and phase to phase voltages (2 P Active power (2 Q Reactive power (2 S Apparent power (2 E, E- Active energy, exported / imported (2 Eq, Eq- Reactive energy, exported / imported (2 PF Power factor f System frequency Phasor diagram views of currents, residual ( or phase or line voltages (2 2nd to 5th harmonics and THD of currents Condition monitoring CB wear Condition monitoring CT supervision Trip Circuit Supervision (TCS) Disturbance recorder Temperature CB control Communication IEC 687-5- IEC 687-5- Modbus TCP Modbus RTU Profibus DP SPA-bus DNP. DNP. TCP IEC 685 Human Machine Interface, display Human Machine Interface, PC Hardware Number of phase current CT s Number of residual current CT s 2 Number of voltage input VT s Number of digital inputs 2 Number of trip outputs 4 Number of alarm outputs Internal Failure, IF (NO/NC) RTD inputs 4-6 ( Example of harmonics content obtained from a relay. ) with zero sequence voltage connection 2) with phase to phase or phase to earth voltage connection ) option

Feeder/motor protection relay Arc flash protection Whether the time-grading or blocking based protection coordination principle is used, the traditional protection systems may not provide fast enough protection of substation faults. Further, high-impedance type of earth-faults may cause prolonged operation times of earth-fault relays leading to the significant release of the arcing energy. These facts pose a considerable risk to human beings and economical assets. By applying a modern, high-speed arc flash protection system the damage may be considerably reduced. Such an arc protection system is an optional feature incorporat-able in all current measuring VAMP relays. The VAMP relays measure the fault current. If the arc flash protection interface option is selected the relays also measure light via arc sensor channels monitoring the whole switchgear. Should an arcing fault occur in the switchgear the arc protection system provides an extremely fast tripping of the circuit breaker. Traditional protection relay systems do not provide fast enough protection in an arc-fault situations. The protection relay with integrated arc protection also provides a cost efficient high-speed MV busbar protection. VAMPSET setting and configuration tool VAMPSET is a user-friendly, free-of-charge relay management software for setting, parameterization and configuring of VAMP relays. Via the VAMPSET software relay parameters, configurations and recorded relay data can be swapped between the operator s PC and the VAMP relays. Supporting the COMTRADE format VAMPSET also incorporates tools for analyzing relay events, waveforms and trends from data recorded by the relays, e.g. during a network fault situation. Using a standard RS cable the PC running VAMPSET connects to the front or rear port of the VAMP relays. The VAMPSET software also supports TCP/IP communication via an optional Base-T connection. Featuring true multi-language support the software runs on Windows 7/Vista / XP / 2 / NT / 98 / 95 without any need for configuration of the PC. The phase sequences for currents and residual voltages can be read on-line from the clear and explicit screen windows for easy commissioning of the relay system. 4 The motor start-up register stores the motor start-up values (start current, duration etc.) significantly facilitating the correct setting of the relay even if critical motor data are unavailable from the manufacturer. Protection setting example As a regular feature of the VAMP relays standard COMTRADE type disturbance recording files can be uploaded for subsequent evaluation of any network event recorded.

L L 2 2 2 s If2 2 st f2 2 Connection diagrams Connection for overcurrent, directional earth fault and residual voltage protection L L2 L - U2 * X2:5 X2:6 X6: X6:2 X6: X6:4 X6:5 X6:6 X6:7 X6:8 X6:9 X6: X6: X6:2 X6: X6:4 IL IL2 IL I 5A I2 A A.2A U /U / ~ Protection functions 5 / 5 67N 5N/5N I> I>> I>>> > 59 27 59N U> U< U>> U<< U>>> U<<< 5ARC 5NARC 5BF ArcI> 46R 48 I / 49 47 T > Arc Arc > 46 5F2/68 > U > U > > CBFP 2 P< P<< 7 I< 66 N> T Front Remote X X4 X2:4 X2: T2 X2:2 X2: T X2: X2:9 T4 X2:8 X2:7 A X2:4 X2:6 X2:5 - VAMP 255 79 Auto Reclose Autorecloser Blocking and matrix output matrix IF X2: X2: X2:2 X9: DI - X9:2 DI DI X9:4 DI2 - X9:5 DI2 Connection for overcurrent, phase to phase or phase to earth voltage protection L L2 L - X2:5 X2:6 ~ Protection functions 5 / 5 67N 5N/5N I> I>> I>>> I> I>> I> I>> Front Remote X X4 - U * X6: X6:2 X6: X6:4 X6:5 X6:6 X6:7 X6:8 X6:9 X6: X6: X6:2 X6: X6:4 I L I 2 L I L I I 2 5A A A.2A U / U / 59 U> U>> U>>> 5ARC ArcI> 46R I /I> 49 T 46 > I2> 27 U< U<< U<<< 5NARC A rc A > rci2 48 I t> 47 I2>> 5F2/68 > 59N U> > U > 5BF CBFP 2 P< P<< 7 I< 66 N> T X2:4 X2: T2 2 X2: X2: T X2: X2:9 T4 8 X2: X2:7 A 4 X2: X2:6 X2:5 UL Connection for phase to earth voltage at voltage transformer secondary. VAMP 255 X9: DI - X9:2 DI DI Autorecloser matrix 79 Auto Reclose Blocking and output matrix IF X2: X2: X2:2 X9: DI2 - *) The residual current can be derived from three phase CTs connected in parallel, from a core balance cable CT or it can be calculated from the three phase currents. X9:4 DI2 5

Feeder/motor protection relay Typical applications Typical application 5,5,5N, 5N,67N, 46,49,68,59N Typical application with integrated arc flash protection 5, 5, 5N, 5N, 46, 49, 68, 79 2 VP4 BIO in out 5,5,5N,5N, 49,46,7, 5,5,5N,5N, 49M,46,47,48, UNBALANCE 66,67N,7 M RTD 8,9 5,5,5N, 5N,67N, 46,49,68,59N, 79 5, 5, 5N, 5N, 46, 49, 68, 79 2 VP4 BIO in out 5, 5, 5N, 5N, 46, 49, 68, 79 2 VP4 BIO in out L> Dimensional drawings The slim casing gives a possibility to install this relay to the secondary equipment compartment which has limited space. All dimensions in mm. Order codes 28 95 4, 9,4 5 5 2,9 2,6 5,4 5,4 52 262 284 2 27 75 9 2 Order Code Description Note Feeder / motor protection relay VAMP Ltd Accessories VEACG Ethernet interface module VPACG Profibus interface module VSE Fiber optic interface module VSE2 RS485 interface module VSE4 RS-485 module VSE5- Ethernet and RS-485 module VSE6 IEC685 module VX- Programming cable (VAMPSET) Cable length m VX28- Interface cable to VPACG (Profibus adaptor) Cable length m VX- Interface cable to VEACG (Ethernet adaptor) Cable length m VX2- Rear panel programming cable Cable length m VYX256A Optional seal for IP54 VP4 Arc option VADA-6 Arc sensor Cable lenght 6 m DI-94MB RTD input module DataQ Instruments Inc. Adam 45-B RTD input module Advantech Co., Ltd Panel cut-out 6

Technical data, Tests and environmental conditions Measuring circuitry Rated current I N 5 A (configurable for CT secondaries A) - Current measuring range 25 A - Thermal withstand 2 A (continuously) A (for s) 5 A (for s) - Burden <.2 VA Rated current I N / 5 A - Current measuring range 5 A / A Rated current I 2N.2 / A - Current measuring range A / 2 A Rated voltage U N / U N V (configurable for VT secondaries 5 2 V) - Voltage measuring range - 75 V - Continuous voltage withstand 25 V - Burden <.5V A Rated frequency f N 45-65 Hz - Frequency measuring range 6-75 Hz Terminal block: Maximum wire dimension: - Solid or stranded wire 4 mm 2 (-2 AWG) Casing Dimensions (W x H x D) 28 x 95 x 55 mm Degree of protection IP 54 Weight kg (terminal, package and manual) Disturbance tests Emission EN 6-6-4 / IEC 6255-26 - Conducted EN55 / IEC 6255-25.5 - MHz - Emitted EN55 / IEC 6255-25 - MHz Immunity EN 6-6-2 / IEC 6255-26 - Static discharge (ESD) EN 6-4-2 class IV / IEC 6255-22-2 8 kv contact discharge 5 kv air discharge - Fast transients (EFT) EN 6-4-4 class IV / IEC 6255-22-4, class A 4 kv, 5/5 ns, 2.5 / 5 khz, /- - Surge EN 6-4-5 class IV / IEC 6255-22-5 4 kv,.2/5 µs, line-to-earth 2 kv,.2/5 µs, line-to-line - Conducted HF field EN 6-4-6 class III / IEC 6255-22-6.5-8 MHz, V - Emitted HF field EN 6-4- class III / IEC 6255-22- 8 - MHz, V/m Auxiliary voltage Rated voltage U AUX Power consumption 9-265 V ac/dc For rated voltages 24 24 V ac /dc < 7 W (normal conditions) < 5 W (output relays activated) Test voltages Insulation test voltage IEC 6255-5 2 kv, 5 Hz, min Surge voltage IEC 6255-5 5 kv,.2/5 µs,.5 J Max. permitted interruption time < 5 ms ( V dc) Terminal block: Maximum wire dimension: - Phoenix MVSTBW or equivalent 2.5 mm 2 (-4 AWG) Digital inputs Qty Rated voltage Digital outputs Trip relays Alarm relays Internal fault relay 2 pcs 8-265 Vdc 4 pcs pc pc Mechanical tests Vibration Shock and pump IEC 6255-2-, class I IEC 6255-2-2, class I Environmental conditions Operating temperature - to 65 o C Transport and storage temperature Relative humidity -4 to 7 o C < 75% ( year, average value) < 9% ( days per year, no condensation permitted) Certified by: 7

With its headquarters in Finland, Vamp Ltd specializes in protection relays, arc flash protection and measuring and monitoring units for power systems. Vamp s medium-voltage and sub-transmission protection relays are used in a number of applications, from overhead line feeders and substations to power plants and industrial power system. Their unique integrated arc fault protection functionality enhances the safety of both people and property and has made Vamp a leading brand in arc protection worldwide. All Vamp products meet the latest international standards and regulations. Our success is based on competitive standard products, constant development by our designers possessing experience from three protection relay generations, our long-term partnerships, flexibility and 24 hour care of the customers. Our organization has been audited and found to be in accordance with the requirements of the ISO 9:2 management system. We reserve the rights to product alterations without prior notice. Copyright Vamp Ltd. All trademarks are the property of their respective holders. VB4.EN7