Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

Similar documents
First Alert FA160C/162C Installer Notes M. Leuck

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Ademco/Protection One 250P1-1 Programming Form

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

CUSTOMER INFORMATION

Property of Monitronics Inc

Ademco Vista-20SE/First Alert FA-162C Program Sheet

Property of Monitronics Inc

Property of Monitronics Inc

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

4140XMPT2 PROGRAMMING FORM

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

ADEMCO VISTA-48A Security Systems

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

APX32EN Security Systems

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

VISTA-50P VISTA-50PUL

VISTA-128BP/VISTA-250BP Programming Form

Lynx Plus Security System

Programming Default Tables

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

Property of Monitronics Inc

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

ADEMCO LYNXR-ENSIA Security System

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

High Security and Access System EVO48 V2.1 EVO192 V2.1

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

2 IDS LCD Keypad User Manual C Issued March 2009

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

VISTA-50PADT VISTA-50PADTUL

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

PROGRAMMING HELP GUIDE

Series. NX-8-EUR Control Panel. Installation manual

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Telephone and Reporting Setup in ElkRP

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

Important Notice. Customer Information. 2 WisDom User Manual

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

NX-148 LCD KEYPAD INSTALLATION MANUAL

Programming Worksheets

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

EVOHD. Programming Guide. Version

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Digiplex EVO High Security and Access System What s New EVO192 V2.7

IDS X-Series User Manual E Issued June 2013

VISTA-10SE, VIA-30PSE, VISTA-20SE E2 ZONE PROGRAMMING. An Improved Zone Programming and 5800 Wireless Device Enrollment Procedure

Includes: 413oxM 513oxM 414oxM 414oxMP

Installation Instructions

DSC programming for the Alexor and Impassa

NetworX Series NX-8V2 Control Panel Installation and Startup

D1260/D1260B. Owner's Manual. Keypad

Modules Programming Guide

Modules Programming Guide. paradox.com

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

DAS LCD ALPHA NUMERIC CODEPAD

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

GEM-P9600 CONTROL PANEL/COMMUNICATOR

VISTA-120. Installation and Setup Guide. Partitioned Security System with Scheduling. N5944-8V1 Rev. B 6/99

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

Control Panel Solution 2000 / 3000

SOFTWARE VERSION 3.20

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

R A D I O N I C S. D7212B Control/Communicator Program Entry Guide C 9/95

Security System. Owner s Manual

SOFTWARE VERSION 3.10

(To modify t he installer code, ref er to section [ 1000], Installer Code Programming on page 21) 1234 or

Emergency Dialer DIAL-ALERT MODEL: AD-105.

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

SIGMA "APOLLO" APOLLO User Manual Page 1

Solution 16 plus. User Guide Security System

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

INT-KSG Keypad Quick user s guide

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

Bosch solution 6000 cheat sheets

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

INT-KSG Keypad Quick user s guide

For use with QED controls panels ONLY

NX-1248E LCD KEYPAD Installation and Setup

Silencing an Alarm Note: Area Systems

SOFTWARE VERSION 3.10

NetworX Series NX-216 Zone Expander Installation and Startup

Table of Contents. HILLS COMNAV INSTALLATION MANUAL V1.3

MG/SP Series (V4.9/V5.1) What s New

Ademco Group Compass Network Downloader

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Transcription:

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE 1. Programming can only be done with a 6139 Alpha Keypad on Vista-10/20/30PSE models. 2. When entering programming for the first time during Installations or Takeovers press *96 to initialize downloading, if this is not done Tech Support can never download the panel in the future. 3. Program different report codes for zones, panics, troubles and Cancels, this will prevent problems sending Exit Alarms and Cancels. Example: 01 00 for Zone 1, 02 00 for Zone 2, 07 00 for Police Panic, 03 for Exit Alarm, 40 for Cancel 4. If system is armed when first powering up, connect a keypad directly to panel, hold down * and # while powering up system (not afterwards) to enter programming. 5. Exit programming with *98 when finished to prevent customers from accidentally entering Installer programming. (This is a big problem with 4110 s and older Vista 10 systems) 6. Program Medical Panic as 08 (Aux Panic), not 06 (Silent Police) 7. To send Exit Alarm (Vista-10/20/30PSE Only) 1. Arm system in Stay or Away 2. Open Entry door before Exit Delay finishes 3. Let alarm sound for 1 minute then disarm system

REMEMBER: PRESS *96 BEFORE INITIAL PROGRAMMING TO INITIALIZE DOWNLOADING! Vista20HWSE-1 PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single partition only. Field Function Programmed Values [ ] = Default Value SYSTEM SETUP (*20-*29) *20 INSTALLER CODE 4 1 1 2 Enter 4 digits, 0-9 [4112] *21 QUICK ARM ENABLE Partition 1 0 Partition 2 0 [0 = no]; 1 = yes *23 FORCED BYPASS Partition 1 0 Partition 2 0 [0 = none]; 1 = bypass open zones "0" for UL installations. *25 WIRED ZONE EXPANSION 0 [0 = none]; 1 = 4219; 2 = 4229; 3 = 4204 *26 CHIME BY ZONE 0 [0 = no]; 1 = yes. Chime for zones in Zone List #3. *27 X-10 HOUSE CODE 0 0 [0 = A]; 1 = B; 2 = C; 3 = D; 4 = E; 5 = F; 6 = G; 7 = H; 8 = I; 9 = J; #10 = K; #11 = L; #12 = M; #13 = N; #14 = O; #15 = P *28 VOICE MODULE ACCESS CODE (4285) 0 0 (Partition 1 only) 1st digit: enter 1-9; 2nd digit: 0; enter #+11 for "*"; or # + 12 for "#". Default = [00] (no Voice Module). *29 OUTPUT TO LONG RANGE RADIO 0 0 To enable enter Trouble code 1-9, A(#+10), B(#+11), C(#+12), D(#+13), E (#+14), or F (#+15). The 2nd digit of Trouble Dialer Report is automatically entered for field *60, [0 to disable]. "0" for UL installations. ZONE SOUNDS AND TIMING (*31 - * 39) *31 SINGLE ALARM SOUNDING/ZONE 0 1 = yes; [0 = no]. "0" for UL installations. *32 FIRE SOUNDER TIMEOUT 1 [0 = timeout]; 1 = no timeout. *33 ALARM BELL TIMEOUT 1 0 = none; [1 = 4 min]; 2 = 8 min; 3 = 12 min; 4 = 16 min; "1" (4 min.) minimum for UL. *34 EXIT DELAY Partition 1 7 0 Partition 2 7 0 0-99 = exit delay time for each partition. Default value = [70 seconds]. *35 ENTRY DELAY #1 Partition 1 3 0 Partition 2 3 0 0-99 = entry delay time for each partition; 20 sec max. for UL. Default value = [30 seconds]. *36 ENTRY DELAY #2 Partition 1 6 0 Partition 2 6 0 0-99 = entry delay time for each partition; 50 sec max. for UL. Default value = [60 seconds]. *37 AUDIBLE EXIT WARNING Partition 1 1 Partition 2 1 0 = no; [1 = yes]. *38 CONFIRMATION Partition 1 0 Partition 2 0 [0 = no]; 1 = yes. OF ARMING DING *39 POWER UP IN PREVIOUS STATE 1 0 = no; [1 = yes]. "1". for UL installations. DIALER PROGRAMMING (*40 - *53) In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0-9; #+11 for " * "; #+12 for "#"; #+13 for a pause. *40 PABX ACCESS CODE Enter 4 digits. If fewer than 4 digits are entered, exit by pressing * (and press 41, if entering next field). To clear entries from field, press *40*. *41 PRIMARY PHONE NUMBER 1 8 0 0 Enter up to 12 digits. Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing * (and press 42, if entering next field). To clear entries from field, press *41*. *42 SECONDARY PHONE NUMBER Enter up to 12 digits. Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing * (and press 42, if entering next field). To clear entries from field, press *42*. *43 PRIMARY SUBSCRIBER ACCT # (PARTITION 1) PRIMARY RECEIVER *45 PRIMARY SUBSCRIBER ACCT # (PARTITION 2) PRIMARY RECEIVER *44 *46 SECONDARY SUBSCRIBER ACCT # (PARTITION 1) SECONDARY SUBSCRIBER ACCT # (PARTITION 2) Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter * as 4th digit, if 3+1 dialer reporting is to be used. If only 3 digits used, exit by pressing *(and press next field). To clear entries from field, press *43*, *44*, *45*, or *46*. Examples: For Acct No.1234, enter: 1 2 3 4 For Acct No.B234, enter: #+11 2 3 4 For Acct No.123, enter: 1 2 3 * SECONDARY RECEIVER SECONDARY RECEIVER Entry of a number other than one specified will give unpredictable results. -1- Vista20HWSE-1

*47 PHONE SYSTEM SELECT 1 If Central Station IS NOT on a WATS line: 0 = Pulse Dial; [1 = Tone Dial] If Central Station IS on a WATS line: 2 = Pulse Dial; 3 = Tone Dial *48 REPORT FORMAT Primary 7 Secondary 7 [7/0] PRIMARY/SECONDARY 0 = 3+1, 4+1 ADEMCO L/S STANDARD 6 or undefined = 4+2 ADEMCO EXPRESS 1 = 3+1, 4+1 RADIONCS STANDARD 7 = ADEMCO CONTACT ID REPORTING 2 = 4+2 ADEMCO L/S STANDARD 8 = 3+1, 4+1 ADEMCO L/S EXPANDED 3 = 4+2 RADIONICS STANDARD 9 = 3+1, 4+1 RADIONICS EXPANDED *49 SPLIT/DUAL REPORTING 0 [0 = Disable (Backup report only)] TO PRIMARY TO SECONDARY 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All 4 = All except Open/Close, Test All 5 = All All *50 15 SECOND DIALER DELAY (BURG) 0 [0 = no]; 1 = yes. "0" for UL installations. *51 PERIODIC TEST REPORT 0 [0 = none]; 1 = 24 hours; 2 = weekly; 3 = 30 days. (Enter Test Code in field *64. Reports with Partition 1 subscriber No.) *52 TEST REPORT OFFSET 2 0 = 24 hour; 1 = 6 hours; [2 = 12 hours]; 3 =18 hours. (Time to 1st report from programming or downloading). *53 SESCOA/RADIONICS SELECT 0 [0 = Radionics (0-9, B-F reporting)]; 1 = SESCOA (0-9 only reporting) Select 0 for all other formats. Entry of a number other than one specified will give unpredictable results. *56 ZONE ASSIGNMENT/ALARM REPORT CODES - This field is an interactive mode. Fill in the required data on the worksheet below (and on next page) and follow the programming procedure in the installation manual. ZONES ON CONTROL: See explanation of headings at top of next page > ZONE ZONE ZONE PARTITION ALARM RPT CODE INPUT RESPONSE ALPHA NUMBER TYPE NUMBER (Hex) TYPE TIME (Zn) (ZT) (P) (RC) (In) (RT) ZONE 01 0 1 0 1 [9] 1 [1] 0 1 0 0 [00, --] HW 350 msec [1 = 350] ZONE 02 0 2 0 1 [1] 1 [1] 0 2 0 0 [00, --] HW 350 msec [1 = 350] ZONE 03 0 3 0 3 [3] 1 [1] 0 3 0 0 [00, --] HW 350 msec [1 = 350] ZONE 04 0 4 0 3 [3] 1 [1] 0 4 0 0 [00, --] HW 350 msec [1 = 350] ZONE 05 0 5 0 3 [3] 1 [1] 0 5 0 0 [00, --] HW 350 msec [1 = 350] ZONE 06 0 6 0 3 [3] 1 [1] 0 6 0 0 [00, --] HW 350 msec [1 = 350] ZONE 07 0 7 0 3 [3] 1 [1] 0 7 0 0 [00, --] HW 350 msec [1 = 350] ZONE 08 0 8 0 3 [3] 1 [1] 0 8 0 0 [00, --] HW 350 msec [1 = 350] ZONE 09 0 9 Tamper 0 5 NA Both 0 0 0 0 [00, --] -- -- ZONE 92 9 2 Duress -- -- Both 0 9 0 0 [00, --] -- -- ZONE 95 9 5 1 *, A 0 9 [0] Both 1 0 0 0 [00, --] -- -- ZONE 96 9 6 3 #, C 0 8 [0] Both 1 1 0 0 [00, --] -- -- ZONE 99 9 9 * #, B 0 7 [6] Both 1 2 0 0 [00, --] -- -- * Zone 1 can be used as a 2-wire Fire zone. ** Zone 8 can be used as a Glassbreak zone. -2- Vista20HWSE-1

EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS Zn = ZONE NUMBER Zone Nos. are from 01 to 63, 92, 95, 96, 99. Some are pre-assigned. With Field *25 set for auxiliary wired loops (4219 or 4229), use Zone Nos. 10-17 for loops A-H. ZT = ZONE TYPE 00 = Not Used 01 = Entry/Exit #1 02 = Entry/Exit #2 03 = Perimeter 04 = Interior Follower 05 = Trouble Day/Alarm Night 06 = 24 Hr Silent 07 = 24 Hr Audible 08 = 24 Hr Aux 09 = Fire 10 = Interior w/delay 20 = Arm-Stay 21 = Arm-Away 22 = Disarm 23 = No Alarm Response 24 = Silent Burglary DEFAULT VALUES Zn: 01 02 03 04 ZT: [09] [01] [03] [03] Zn: 05 06 07 08 99 ZT: [03] [03] [03] [03] [06] P = PARTITION NUMBER 1 or 2. Default Values for zones 01-08 = [1]. RC = ALARM REPORT CODE Two Hex Digits. For each Hex Digit, enter: 00-09 for 0-9 10 for A, 11 for B, 12 for C, 13 for D, 14 for E, 15 for F. If "00" is entered in the first pair of boxes, there will be no report for that zone. For Contact ID reporting, this is an enabling code only. Enter any Hex digit (other than "00") in the first pair of boxes. The second pair of boxes will be ignored. In = LOOP INPUT DEVICE HW: Hard Wire AW: Aux Wire (4219 or 4229) RT = RESPONSE TIME EXPANSION ZONES: 0 = 10 msec; 1 = 350 msec; 2 = 700 msec. Default Values for zones 01-08 = [1 (350 msec)] Assign Zone Numbers (Zn) 10-17 to 4219/4229 Auxiliary Wired Loops A-H, if used. All expansion zone information defaults to [0]. EXP'N ZONE ZONE PARTITION ALARM RPT CODE INPUT ALPHA NUMBER TYPE NUMBER (Hex) TYPE (Zn) (ZT) (P) (RC) (In) ZONE 10 1st Exp'n Zone 1 0 -- -- -- -- ZONE 11 2nd 1 1 -- -- -- -- ZONE 12 3rd 1 2 -- -- -- -- ZONE 13 4th 1 3 -- -- -- -- ZONE 14 5th 1 4 -- -- -- -- ZONE 15 6th 1 5 -- -- -- -- ZONE 16 7th 1 6 -- -- -- -- ZONE 17 8th 1 7 -- -- -- -- ZONE 18 9th 0 0 -- -- -- -- ZONE 19 10th 0 0 -- -- -- -- ZONE 20 11th 0 0 -- -- -- -- ZONE 21 12th 0 0 -- -- -- -- ZONE 22 13th 0 0 -- -- -- -- ZONE 23 14th 0 0 -- -- -- -- ZONE 24 15th 0 0 -- -- -- -- ZONE 25 16th 0 0 -- -- -- -- ZONE 26 17th 0 0 -- -- -- -- ZONE 27 18th 0 0 -- -- -- -- ZONE 28 19th 0 0 -- -- -- -- ZONE 29 20th 0 0 -- -- -- -- ZONE 30 21st 0 0 -- -- -- -- ZONE 31 22nd 0 0 -- -- -- -- ZONE 32 23rd 0 0 -- -- -- -- ZONE 33 24th 0 0 -- -- -- -- ZONE 34 25th 0 0 -- -- -- -- ZONE 35 26th 0 0 -- -- -- -- ZONE 36 27th 0 0 -- -- -- -- ZONE 37 28th 0 0 -- -- -- -- ZONE 38 29th 0 0 -- -- -- -- ZONE 39 30th 0 0 -- -- -- -- -3- Vista20HWSE-1

TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (*59-*76, & *89): With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1-9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. A "0" (not "#+10") in the first box will disable a report. A "0" (not "#+10") in the second box will result in automatic advance to the next field when programming. With an Expanded or 4+2 Format: Enter codes in boxes (1st and 2nd digits) for 1-9, 0, or B-F, as described above. A "0" (not "#+10") in the second box will eliminate the expanded message for that report A "0" (not "#+10") in both boxes will disable the report With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report (entries in the second boxes will be ignored). A "0" (not "#+10") in the first box will disable the report. Examples: For Code 3 (Single Digit), enter: 3 0 For Code 32 (Two Digits), enter: 3 2 For Code B2 (Hexadecimal), enter: #+11 2 SYSTEM STATUS REPORT CODES (*59-*68) *59 EXIT ERROR REPORT CODE [0] 4 *60 TROUBLE REPORT CODE [0-] 1 0 *61 BYPASS REPORT CODE [0-] 0 0 *62 AC LOSS REPORT CODE [0-] ~ 0 0 *63 LOW BATTERY REPORT CODE [0-] ~ 2 0 *64 TEST REPORT CODE [0-] 0 0 *65 OPEN REPORT CODE [0] Partition 1 0 Partition 2 0 *66 ARM AWAY/STAY REPORT CODE [0,0] Partition 1 0 0 AWAY HOME Partition 2 0 0 AWAY STAY 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in *56, if expanded or 4+2 reporting is selected. 2nd digit is automatically sent as the user number if expanded or 4+2 reporting selected. *68 CANCEL REPORT CODE [0-] 3 0 RESTORE REPORT CODES (*70-*76) *70 ALARM RESTORE REPORT CODE [0] 0 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in *56, if expanded or 4+2 reporting is selected. *71 TROUBLE RESTORE REPORT CODE [0-] 0 0 *72 BYPASS RESTORE REPORT CODE [0-] 0 0 *73 AC RESTORE REPORT CODE [0-] ~ 0 0 *74 LOW BATTERY RESTORE [0-] ~ REPORT CODE 0 0 ~ Reports with Partition 1 Subscriber Number *76 TEST RESTORE REPORT CODE [0-] 0 0 OUTPUT AND SYSTEM SETUP (*80-*93) *80 OUTPUT RELAYS AND POWERLINE CARRIER DEVICES *81 ZONE LISTS FOR OUTPUT DEVICES AND COMMON AREA Program only if Relays and/or Powerline Carrier devices are to be used. See next page. *82 CUSTOM ALPHA EDITING: (Also entered from field *56): See procedure in instructions. *89 EVENT LOG 80% FULL REPORT CODE [0-] 0 0 *90 EVENT LOGGING 0 3 0 = None; 1 = Alarm/Alarm Restore; 2 =Trouble/Trouble Restore; 4 = Bypass/Bypass Restore; 8 = Open/Close. Example: To select "Alarm/Alarm Restore", and "Open/Close", enter 9 (1+8); To select all, enter #15. Default = [3] (1+2). Note: System messages are logged when any non-zero selection is made. *91 OPTION SELECT [0 = None]; 4 = AAV; 8 = Exit Delay Restart 0 "0" for UL installations *92 PHONE LINE MONITOR ENABLE [0 = Not used]; 0 1 = Keypad display when line is faulted; 2 = Keypad display plus keypad trouble sound; 3 = Same as "2", plus #2 STARTS. If either partition is armed, external sounder activates also. Note: Device #2 must either be programmed to be STOPPED in field *80 or STOPPED by Code + # + 8 + 2. *93 NUMBER OF REPORTS IN ARMED PERIOD [0 = 10 Alarm/Alarm Restore Reports]; 0 1 = Unlimited. "1" for UL installations. DOWNLOAD INFORMATION (*94, *95) <> *94 DOWNLOAD PHONE No. 1 8 0 0 7 6 2 7 8 3 1 Enter up to 12 digits: 0-9; #+11 for '*'; #+12 for '#'; #+13 for a pause. Do not fill unused spaces. If fewer than 12 digits entered, exit field by pressing * (and press 95, if entering next field). To clear entries from field, press *94*. *95 RING DET COUNT FOR DOWNLOADING 1 5 O=Disable Station Initiated Download; 1-14=number of rings (1-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14); [15=answering machine defeat] (#+15=15) Note: Do not enter "0" if using 4285 Voice Module. <> In UL installations, downloading may only be performed if a technician is at the site. *96 INITIALIZES DOWNLOAD ID, SUBSCRIBER ACCOUNT No. FOR INITIAL DOWNLOAD: No data entry required. *97 SETS ALL PROGRAM FIELDS TO DEFAULT VALUES: No data entry required. *98 and *99 USED TO EXIT PROGRAM MODE (see page "6") -4- Vista20HWSE-1

OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81. Applicable only if Relays and/or powerline Carrier Devices are to be used. *80 OUTPUT RELAYS - This is an interactive menu mode. Fill in the required data on the worksheet on below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, field *25 must be programm ed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04). 2. For Powerline Carrier devices, field *27 must be programm ed with a House Code. 3. Tampers of contacts or expansion units cannot be used to operate devices. S T A R T either or both S T O P either or both ZONE ZONE TYPE PART'N RESTORE of ZONE TYPE PART'N DEVICE X-10 ACTION EVENT LIST /SYST OP'N No. ZONE LIST /SYST OP'N No NUMBER SELECT (A) (EV) (ZL) (ZT) (P) (ZL) (ZT) (P) OUTPUT RELAY OR P.L.C.D.* 01 OUTPUT RELAY OR P.L.C.D.* 02 OUTPUT RELAY OR P.L.C.D.* 03 OUTPUT RELAY OR P.L.C.D.* 04 P.L.C.D.* 05 P.L.C.D.* 06 P.L.C.D.* 07 P.L.C.D.* 08 *P.L.C.D. = Powerline Carrier Device (X-10). Where: X-10 SELECT = Powerline Carrier Device Enter "1" if powerline Carrier Device is being used, enter "0" if relay is being used. A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off EV = EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble. ZL = ZONE LIST 1,2,or 3 (from Field *81) or 0 = Not Used. "START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, relay action will START. "STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, relay action will STOP. It need not be same list as used for START. NOTE: Do not use input type "BR" transmitters in a zone list to STOP a relay action, since these transmitters do not send restores. ZT = ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are: 00 = Not Used 06 = 24 Hr Silent Note: Any zone in "ZT" going into alarm, 01 = Entry/Exit #1 07 = 24 Hr Audible fault, or trouble will actuate relay. 02 = Entry/Exit #2 08 = 24 Hr Aux Any zone of that type that restores 03 = Perimeter 09 = Fire will stop relay action. 04 = Interior Follower 10 = Interior w/delay 05 = Trouble Day/Alarm Night 24 = Silent Burglary Choices for System Operation are: 20 = Arming-Stay 38 = Chime 52 = Kissoff 21 = Arming-Away 39 = Any Fire Alarm 58 = Duress 22 = Disarming (Code + OFF) 40 = Bypassing 31 = End of Exit Time 41 = **AC Power Failure 32 = Start of Entry Time 42 = **System Battery Low 33 = Any Burglary Alarm 43 = Communication Failure 36 = **At Bell Timeout*** Note: In normal operation mode: ** Use 0 (Any) for Partition No. (P) entry. Code + # + 7 + N Key Entry starts Device N. *** Or at Disarming, whichever occurs earlier. Code + # + 8 + N Key Entry stops Device N. P = PARTITION No. 1, 2, or 0 for Any -5- Vista20HWSE-1

*81 ZONE LISTS FOR OUTPUT DEVICES- This is an interactive mode. Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Note: Record desired zone numbers below. More or fewer bowes than shown may be needed, since any list may include any or all of system's zone numbers. Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).,,,,,,,,,,...etc. Zone List 2: Started or stopped by zone numbers (enter 00 to end entries).,,,,,,,,,,...etc. Zone List 3: Started or stopped by zone numbers (enter 00 to end entries).,,,,,,,,,,...etc. Common Area Zone List: Started or stopped by zone numbers (enter 00 to end entries).,,,,,,,,,,...etc. SPECIAL MESSAGES OC = OPEN CIRCUIT (no communication between Console and Control). EE = ERROR (invalid field number entered; re-enter valid field number). After powering up, AC, dl (disabled) or System Busy and NOT READY will be displayed after approximately 4 seconds. This will revert to READY in appx. 1 minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#] + [0]. If E4 or E8 appears, more zones than the expansion unit's capacity have been programmed. Correct the programming and then completely de-power and re-power the control to clear this indication and remove the disable indication. TO ENTER PROGRAMMING MODE: 1. POWER UP, then depress [*] and [#] both at once, within 50 seconds of powering up. OR 2. Initially, key Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0. OR 3. If different Installer Code is programmed, key: New Installer Code + 8 + 0 + 0. (if *98 was used to exit previously, method 1 above must be used to enter the program mode again). TO EXIT PROGRAMMING MODE: *98 Exits programming mode and prevents re-entry by: Installer Code + 8 + 0 + 0. If *98 is used to exit programming mode, system must be powered down, and method 1 above used to enter the programming mode. *99 Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0. or: Power-up, then "*" and "#". -6- Vista20HWSE-1

To program these fields, 1. Press *91 to select a partition. 2. Enter a partition-specific field number (ex. *09). 3. Repeat steps 1 & 2 for each partition in the system. 4. To return to the global program fields, press *99. PARTITION-SPECIFIC FIELDS PARTITION # 1 PROGRAM FIELDS *21 QUICK ARM ENABLE 0 [0 = no]; 1 = yes *23 FORCED BYPASS 0 [0 = none]; 1 = bypass open zones *34 EXIT DELAY 7 0 0-99 = exit delay time for this partition. [70 seconds] *35 ENTRY DELAY #1 3 0 0-99 = entry delay time for this partition. [30 seconds] *36 ENTRY DELAY #2 6 0 0-99 = entry delay time for this partition. [60 seconds] *37 AUDIBLE EXIT WARNING 1 0 = no; [1 = yes] *38 CONFIRMATION OF ARMING DING 0 [0 = no]; 1 = yes *65 OPEN REPORT CODE [0] 0 *66 ARM AWAY/STAY REPORT CODE [00] 0 0 AWAY STAY Partition 1 Vista20HWSE-1

Protection One Ademco Vista-20 Quick Reference Guide Monitoring and Service call 1-800-654-6770 Arming (Away) Disarming and Silencing Alarms Arming (Stay) Enter 4-digit code + AWAY key (2), the display will show AWAY (If NOT READY press * to view open zones Enter 4-digit code + OFF key (1) If turning off an alarm enter 4 digit code + OFF key again to clear display Enter 4-digit code + STAY key (3), system will arm and the display will show STAY Zone Bypassing Additional Codes Enter 4-digit code + BYPASS key (6) + zone to be bypassed (01, 02, 03..) then arm system. The display will show Bypass and the zone bypassed, this must be done quickly! While system is disarmed enter MASTER CODE + CODE key (8) then the user code you wish to program (03 to 16) then enter desired code, system will beep once when completed. (This must be done quickly) Door Chimes To turn chimes on or off enter 4-digit code then the CHIME key (9) Instant Doors Trouble Lights Panic Buttons Enter 4-digit code then the INSTANT key (7) to arm system, all Entry/Exit doors will arm with no entry delay and all motion or interior zones will be bypassed. The display will show both STAY and INSTANT Loss of AC power is indicated when the display shows NO AC on the keypad A display of LOW BAT indicates possible battery trouble, if zone also shows, a wireless sensor battery is low A display of CHECK indicates a problem elsewhere with the system or if a fault is detected in a fire zone. To use the 3 panic buttons hold down both keys for 2 seconds for Police, Medical and Fire (if available) On many systems holding down a combination of numbers will activate the panics Holding down * and # keys at the same time will activate a POLICE panic Holding down 1 and * keys at the same time will activate a FIRE panic Holding down 3 and # keys at the same time will activate a MEDICAL panic