SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

Similar documents
SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

SERVICE MANUAL MODEL SSP-561-X-ADA

SERVICE MANUAL MODEL SSW-321-X

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL MODEL SSW-520-F

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)

SERVICE MANUAL. MODEL SSW-321-Fr1

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL MODEL SSW-321-D

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

SERVICE MANUAL MODEL SSP-350-X

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

SERVICE MANUAL MODEL SSC-303-I MODEL BLC-303-1

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Big button Speakerphone MODEL: FC-8814

NT1B-300 Rack Installation Instructions

28-Position 23 Rack Mounting Model RM23-20X

ET Number One-Touch Memory Home/Office Speakerphone. Owner s Manual. Please read before using this equipment.

CIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

Page/Talk Industrial Desk Sets

FUTURE CALL USER MANUAL PICTURE PHONE WITH SPEAKERPHONE MODEL: FC-1007 SP / PD

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613

Customer Service: (for U.S. and Canada) Customer Service

MFJ ENTERPRISES, INC.

QuickTap. JK Audio. Telephone Handset Tap. User Guide

DLE-300. Advanced Line Simulator for Communication, High Speed Data, Caller ID and Classroom Training. Advanced Line Simulator. Features.

FUTURE CALL. Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

MFJ ENTERPRISES, INC.

V-9964 Digital Feedback Eliminator/Message Stacker

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

TS-Modem User s Manual

V-9964 Digital Feedback Eliminator/Message Stacker

V-9939B MICROPHONE ADAPTER

EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

Automatic Phone-Out Home Monitoring System

AC Powered Dialer with Increased Toll Restriction and Added Versatility

TABLE OF CONTENTS INTRODUCTION... 2

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

DS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time

Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

Audio Cable (For CD Players Only) Sensor Board Cable

Owner s Instruction Manual

Version 4.6 Firmware DA2002. Includes Instructions on Installation, Programming, & Troubleshooting

OPERATION MANUAL. for the BO BLASTER S OHMMETER

VIP-812A DUAL NETWORKED STATION PORT

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

iconverter 2-Module Power Chassis

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

38 Series Telephones User Guide Covers Models

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

Digital Lighting Systems, Inc.

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Installation Notes TII Model 341 Protector

EP/2 Installation Instructions

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

LINESTEIN DIGITAL ADAPTER

DIAMOND ELITE SERIES USERS GUIDE

6220 and 6225 Telephones Quick Reference

EAR K. Installation and Programming. Manual

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

BTH-800. Wireless Ear Muff headset with PTT function

OWNER S INSTRUCTION MANUAL

OWNER'S MANUAL. Please read before using this equipment E IPP 520. USB Speaker Phone

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

User Manual Back-UPS BE650MC

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

BTH-900. Wireless Ear Muff headset w/dual Connections

ICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT

PTT-100-VZ Wireless Speaker Microphone

DC425 NEMA 4X Analog Output Transducers

DCM Digital Control Modules

CA-A480-A Elevator Controller. Reference & Installation Manual

Transcription:

SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee, FL 34972 Voice: 863-357-0798 Fax: 863-357-0006

IMPORTANT INFORMATION FOR CUSTOMER Please fill in before you continue. The following information is necessary when calling for assistance. MODEL NUMBER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED MODEL SSC-500-F, EQUIPPED WITH THE LOW POWER SPEAKER BOARD. For us to better serve you, please have this information available when calling for technical support. 519 W South Park Street Okeechobee, FL 34972 863-357-0798- telephone 863-357-0006- facsimile info@ceeco.net www.ceeco.net 2

TABLE OF CONTENTS SECTION PAGE 1.0 INTRODUCTION... 4 2.0 GENERAL... 4 3.0 PROGRAMMING... 5 4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT... 5 5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS... 6 6.0 TESTING/OPERATION... 7 7.0 SPECIFICATIONS... 7 8.0 PARTS LIST... 8 9.0 FCC NOTICE... 9 10.0 REPAIR AND RETURN INFORMATION... 10 11.0 WARRANTY POLICY... 11 3

1.0 INTRODUCTION The practices in this manual provide installation and maintenance information for the Model SSC-500-F Stainless Steel Hands Free Charge-A-Call Telephone, equipped with the Low-Power Speaker Board. The information in this manual is subject to change without notification. For information not included in this manual, please call or write: Customer Service 519 W South Park Street Okeechobee, FL 34972 863-357-0798- telephone 863-357-0006- facsimile info@ceeco.net www.ceeco.net 2.0 GENERAL 2.1 The Model SSC-500-F Hands Free Telephone is a sturdy, vandalresistant, Stainless Steel Wall Speakerphone. Instead of a hookswitch and handset, the telephone has a Press to start/press to stop button for initiation and termination of phone calls. Manual volume control is also provided inside the telephone. 2.2 The SSC-500-F is fully line powered with no battery backup required for memory retention. 2.3 The phone may be programmed to set an automatic call disconnect (timeout feature) for one, three, or five minutes. 2.4 Programming is accomplished by way of hardware (mini-jumpers on PCB). 4

3.0 PROGRAMMING NOTE: It is recommended that you ground yourself to prevent ESD damage to the PCB(s). 3.1 Remove the telephone from its housing by loosening the security screws with the security tool (sold separately) and remove them. 3.2 Locate the green plastic mini-jumpers on the PC board. They are used to program the time out disconnect feature. 3.3 If the time out disconnect feature is not desired, simply place the green plastic mini-jumper at P.C. board location JP3 in the OFF position. 3.4 If time out disconnect is to be used, place the green plastic mini-jumper at P.C. board location JP3 in the ON position. The time out disconnect feature offers three choices of conversation length. The Time begins when the Press to start/press to stop button is pressed. The times are not exact. In order to set the length of time for the automatic call disconnect place the green plastic mini-jumper at P.C. board location JP2 as follows: Position 1 (for ONE- minute conversation time) Position 3 (for THREE- minute conversation time) Position 5 (for FIVE- minute conversation time) 4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT Volt/Ohm Meter 5/16" Nut driver 1/4" Nut driver Security Tool, part number 301-037 5

5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 5.1 Using a 301-037 security tool (sold separately), loosen (do not remove) the locking screw and security screws on either side of the telephone. 5.2 The security tool is for a standard 5/32" button head screw generally used on the framework of the phone booths. 5.3 Separate the cover assembly from the back plate assembly. The back plate assembly may be installed on any standard backboard or coin phone enclosure. 5.4 Run the inside station wire through the back plate assembly and terminate on to the RJ11C terminal block on the back plate. 5.5 The use of a gas tube station protector is recommended. The station ground should not exceed 50 ohms. 5.6 Install the instruction card, instruction card window and instruction card frame using the eight retaining nuts provided. A 5/16 inch nut driver is required. 5.7 Plug the modular line cord from the cover assembly into the RJ11C terminal block. 5.8 Dress the line cable away from the locking screw and install the cover assembly by hanging it on the four hook-shaped supports. Secure the back plate by tightening the locking screw and the security screws. *****WARNING***** A. Never install telephone wiring during lightning storm. B. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. C. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. D. Use caution when installing or modifying telephone lines. 6

6.0 TESTING/OPERATION Action: Reaction: Action: Reaction: Action: Reaction: Connect the phone to the line. Press the start /stop button. Dial tone. Dial a number. The called party answers. A normal speakerphone conversation is allowed. Finish the conversation. Press the start/stop button. If the button is not pressed, and the automatic call disconnect feature is in use, the phone will reset after the set time expires. The call is terminated. 7.0 SPECIFICATIONS INPUT POWER: LOOP CURRENT: IMPEDANCE: SIGNALING: OUTPUT: ENVIRONMENTAL: TELEPHONE PANEL: DIMENSIONS: MOUNTING: WEIGHT: C.O. Line powered 27mA minimum 600 ohms DTMF -8.0dbm to -10dbm Temperature 0oC to 50oC Humidity 20%-90% non-condensating Stainless Steel (16gauge) 7 1/2" Wide x 21" High x 4 1/8" Deep Standard Coinless Public telephone foot Print. Approximately15 lb. RINGER EQUIVALENCY: 0.4A TYPE JACK: UL LISTED NO.: RJ11C 6OF5 7

8.0 PARTS LIST QUANTITY PART NUMBER DESCRIPTION 1 301-030 INSTRUCTION CARD KIT 1 301-012 OUTER COVER LOCKING SCREW 1 301-018 MODULAR LINE CORD 1 SSC-500-F STAINLESS STEEL OUTER COVER 1 301-039 NUMBER WINDOW 1 301-040 NUMBER CARD 1 301-051 BACK PLATE 1 301-052 RUBBER GROMMET 1 301-054 MODULAR CONNECTOR (RJ11C) 1 391-017 KEYPAD CABLE 1 600-SPK CIRCUIT BOARD WITH MICROPHONE 1 391-113 SPEAKER 1 730-ANS(M) CONNECTORIZED KEYPAD 1 951-001 MOMENTARY PANEL SWITCH 2 321-016 SECURITY SCREW 8

9.0 FCC NOTICE 9.1 FCC REGISTRATION AND REPAIR INFORMATION Your new telephone has been registered with the Federal Communication Commission (FCC) in accordance with Part 68 of its rules. The FCC requires that you be advised of certain requirements involving the use of this telephone. 9.2 CONNECTION AND USE WITH THE NATIONWIDE TELEPHONE NETWORK The FCC requires that you connect this telephone to the Nationwide Telephone Network through a registered jack provided by the Telephone Company in your area. This jack is a modular outlet, which you can order from your local telephone company. 9.3 NOTIFICATION TO THE TELEPHONE COMPANY Before connecting this telephone, the FCC requires that you notify your local telephone company business office. The number is in the front of your phone book. Tell them: The "line" to which you will connect the telephone (that is, your phone number), the telephone's FCC registration number and ringer equivalence number. These numbers are listed in section 7.0 The FCC further requires that you notify your local telephone company when permanently disconnecting this telephone. 9

10.0 REPAIR AND RETURN INFORMATION 10.1 WARRANTY REPAIR Any device returned requiring warranty service, repair or credit must be accompanied with a "Return Material Authorization" (RMA) Form. It must include: RMA Number, return shipping instructions., original purchase order number, serial number and special marking instructions. A tag with the trouble observed must be attached to the defective unit. This information must be inside the shipping container. 10.2 DIRECT ALL INQUIRES TO Repair Department 863-357-0798- telephone 863-357-0006- facsimile info@ceeco.net www.ceeco.net 10.3 NON-WARRANTY REPAIR will repair equipment out of warranty for a set charge plus parts. The customer must pay the shipping costs for both directions. 10.4 RETURN FOR CREDIT Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer's list price. Return Material Authorization (RMA) must be requested no later than 30 days after original shipment. 10

11.0 WARRANTY POLICY 11.1 GENERAL guarantees its products to be free from defects in material and workmanship for a period of 365 days from the date of original purchase. 's obligation under this warranty is limited to repair or replacement of any part found to be defective by. UNDER NO CIRCUMSTANCES shall be liable for loss, damage, cost of repair or consequential damages of any kind, which have been caused by neglect, abuse, Acts of God, or improper operation of equipment. will repair or replace any unit during this period if found to be defective for reasons other than abuse, neglect, Acts of God, improper use or improper installation. It is the buyer s responsibility to return the defective unit to the factory. will then repair or replace any defective parts and return them to the buyer free of charge. 11.2 PRINTED CIRCUIT BOARDS Printed circuit boards should not be repaired in the field. If a unit is found to be faulty, replace it with another unit and return the faulty unit to for repair. Modifications by any one other than will void the warranty. 11