A S C O R I N C O R P O R A T E D VXI MODULES

Similar documents
CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

Model SPDT Switch Module

Model 7026 (1x32) 2-wire Multiplexer

Model DPDT Switch Module

Model SPDT 5A Relays

34970A 3499A/B/C. Advanced Test Equipment Rentals ATEC (2832) 34970A and 3499A/B/C Switch Systems

Series 8000 RF Signal Switch Solution

Model , 32C, 32S, 32i/opt 1, opt 5 4(1x8) & 8(1x4) & 8(1x2) Coaxial Multiplexer

Model SPDT Mercury Wetted Relays

Keysight U2751A USB Modular Switch Matrix

Safety Standards. Model Number:

pickeringtest.com B Microwave Multiplexer Module

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

Agilent U2751A USB Modular Switch Matrix. Data Sheet

N1810/1/2 Coaxial Switches

LGR-5325 Specifications

Series 8000 RF Signal Switch Solution

Relay Contact Output Modules

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

High Density Switch Mainframe and Cards

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

CT-400 FEATURES. A Price/Performance Breakthrough for VXI Mainframes. Modular Power Supply Assembly. Over 1100 Watts of Usable Power

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

GE Fanuc IC694ALG221. Rx3i PacSystem

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

Screw terminal panels, Relay output boards, connection cables

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Slick Line Acquisition System Manual

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

pickeringtest.com A 2Amp BRIC 2nd Generation PXI Switching 3U PXI Multi Slot Matrix Module

WENS 540 Multifunction Oscillscope Meter

New. A g i l e n t Basic Instruments Catalogue Series Portable Oscilloscopes. See what you ve been missing. IT and Instrumentation for industry

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

Detailed Specifications 6 1/2 Digits High-Performance DMM

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Parametric test systems

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Improved Switching Architectures for ATE Systems

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

BRIC MODULE BRIC ANALOG BACKPLANE BUS MATRIX INPUTS DAUGHTER CARD #3 RESOURCE DISTRIBUTOR DAUGHTER CARD #2

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

product HP 3499A/B Switch/Control Mainframe Test at the speed of the Revolution

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Measurement Systems Datascan Installation and User Guide

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Personal Daqs USB Data Acquisition Modules Models /55 & /56

General information. Display. Supply voltage. Input current

40-785B Microwave Multiplexer Module

CPS Industrial Power Supply

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

LGR-5327 Specifications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RT4F-48V/50A-WAC RECTIFIER

CompuScope 3200 product introduction

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Specifications USB-1616FS

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ACCESS 9340/9360 Meter Input/Output Module

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Digital Indicator Solutions

6220 Ethernet-Based Voltage Measurement Module

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

TALON Network Manager- 2 & 6 Express

Model Number Structure

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

PC-CARD-DAS16/12 Specifications

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

RT4F-110V/25A RECTIFIER

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

Model 7705 Control Module

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

8B SLX300 Data Acquisition System

Keysight Technologies

TTX400-3U-1S Watt, 3U, 1 Slot, 24VDC Input, CompactPCI Power Supply. CompactPCI POWER SUPPLY

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current

5.5-Digit Multimeter, B-Size HP E1326B. Technical Specifications. Description

PC-CARD-DAS16/16 Specifications

CM6800E Matrix Switcher/Controller MICROPROCESSOR-BASED, CROSS-POINT VIDEO SWITCHER, 48 X 8, EXPANDABLE

Agilent 84904, 6, 7K/L Programmable Step Attenuators

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

C1U-W Tx Series

Power Supply Selector Guide

Transcription:

A S C O R I N C O R P O R A T E D VXI MODULES

General Purpose Switch Modules Most VXI test environments require general purpose switching capabilities to enable and disable particular I/O circuits, especially during fault analysis routines and subroutines. ASCOR general purpose switch modules are ideal for low frequency switching and power switching applications. These VXI Switching Modules are tailored for maximum flexibility for system integration. The modules are all C-size with up to 96 SPST Form A relays rated at 5 amps 250 VAC, as well as 48 SPST relays rated at 10 amps 250 VAC or 48 SPDT relays rated at 5 amps 277 VAC, each meeting requirements for high current switching in ATE systems. They are the industry s highest density general purpose switches and include Models 3000-2, 3000-12, 3000-42, 3000-43 and 3000-53/53A. Shielded Relay Scanner & Matrix Modules ASCOR s shielded relay scanners, such as the Model 3000-3 and 3000-8, are ideal for general scanning purposes, including Digital Multi-Meters (DMMs). Using shielded relays in scanner or multiplexer applications where there are a large number of channels will provide excellent signal isolation and low crosstalk characteristics. Channels are individually controlled for maximum versatility. When using shielded relays, ASCOR coaxially ties the relay shields to a separate analog ground plane in order to ensure minimal crosstalk and signal interference. The switch matrix modules are available from combinations of 2x128 single-wire (3000-34) to 2x128 (3000-44), 4x64 two-wire (3000-45) and 8x32 two-wire (3000-47). Bandwidths range from a low of >40 MHz to a high of >90MHz ensuring a low noise environment. If crosstalk is not a major concern, most of the shielded modules are also available with non-shielded relays. High Frequency Shielded Coax Switches ASCOR offers a variety of High Frequency Coax Switches. All of the Coax Switch VXI modules use internally cabled switch path at 50 ohms. Also available upon request is a 75 ohm switch path. The ASCOR Coax Switches include matrices from 2x32 at >350 MHz for the worst path (3000-5) to 1x8 multiplexers at >500 MHz (3000-32). These switch modules are ideal for use with oscilloscopes, frequency counters and other instruments that require clean coax signals.

SERIES 3000 VXI MODULES Microwave & RF Switch Modules ASCOR builds numerous RF and microwave VXI modules. Our RF modules start with the Model 3000-54 (12 1x4s at >1.3 GHz) and extend through our newest 3000-515 (16x12 RF Matrix at >900 MHz for the worst path). The 3000-55 is also available as a dual 4x4 matrix, the 3000-55A. Our microwave switches are provided with ASCOR s unique pluggable capability designed to ensure maximum flexibility in switch selection and minimal (Mean Time To Repair) MTTR in the event a switch needs to be changed or replaced. Available in two-wide VXI modules and three-wide VXI modules, the 3000-200s are available in either DC to 18 GHz or DC to 26 GHz performance specs as well as self-terminated versions. Special Modules In addition to our switch modules, ASCOR offers a number of special modules designed to meet the ever demanding requirements of our customers, from the Model 3000-4 relay driver module (128 general purpose 5, 12 or 24 volt coil drivers) to the 3000-62 with its optional mix of up to 256 TTL I/O, CMOS, Differential and Open Collector Drivers in a single VXI slot. ASCOR also offers special VXI modules such as the 3000-46, that supports both digital and analog signal switching, and the 3000-39, that is capable of supporting a high level of I-level or intermediate level switching. (Please read ASCOR write-up entitled Programming VXI Switching ). ASCOR also designs and manufactures custom and semicustom VXI modules for a number of special customer-defined applications. Feel free to contact ASCOR if you have a special VXI requirement. All ASCOR standard VXI modules include VXIplug&play drivers written in C++ using LabWindows CVi and operating under WIN95 or WINNT. All ASCOR VXI modules are Register-based and include VXIMAX 16/32, ASCOR s exclusive capability to operate our VXI modules in either 16-bit or 32-bit data paths. VXI DMM With M-Module The ASCOR Model 3801 is a one wide, C-size VXI card which comes standard with a Digital Multimeter (DMM) and the capability of adding an industry standard M-Module mezzanine card. The on-board 6 3 /4 digit DMM is a high performance Digital Multimeter optimized for a variety of applications such as automated production testing, control and data acquisition, portable field testing, laboratory automation, disk drive testing and resistance network testing.

There are two types of DMMs available with the Model 3801. The standard DMM provides the following measurement capabilities: DC Volts and Current AC Volts and Current Resistance: 2-Wire and 4-Wire Each function provides at least four ranges of values. Accuracy on the DC Volts and on the Resistance functions is better than 0.0004%. The extended capability DMM ( DMM/LCR ) provides for all the functions listed above for the standard DMM. In addition the DMM/LCR provides the following additions capabilities: Resistance: 6-Wire Guarded Temperature: -150 C to +650 C Leakage Current: 1nA to 3300nA Capacitance: 1nF to 10 mf Inductance: 1uH to 3.3H Peak to Peak, Crest & Median Volts Timing Functions: AC/DC Voltage & Current Sourcing DCV Source: -10.0V to +10.0V ACV Source: 0v to 20V P to P DC Current: 1.25uA to 12.5mA The 3801 also has the capability of mounting a single industry standard M-Module mezzanine card. These units provide functions like Analog to Digital Conversion (A/D), Digital to Analog Conversion (A/D), Universal Timer/Counter ( UTC ). Any industry standard M-Module may be used. M-Modules provided by ASCOR come complete with a software driver provided. Other M-Modules not provided by ASCOR Inc. will require the user to provide their own software driver. As with all ASCOR VXI Modules, The Model 3801 is a register-based device. The software drivers that are provided are written using Lab Windows CVi and are written in C++. System Integration In addition to the multitude of VXI modules, ASCOR offers System Integration services to our customers. These services capitalize on our transmission line expertise and are designed to ensure that all signals within a test station reach the proper instrument or unit under test (UUT) with unparalleled fidelity and integrity. The test station is only as good as the integrity of the signals that it uses to stimulate and measure the response. The degree of care with which ASCOR builds applicable wiring harnesses ensures overall system performance, normally well in excess of minimum specification. While we leave the test application software to the end user or Test Program Set (TPS) developer, ASCOR should be considered for tying all of your selected instruments, switches, interface adapters and UUTs together to provide the most reliable and yet, cost efficient system packaging available. By using our electrical engineering and mechanical engineering expertise, you gain a significant advantage in achieving a comprehensive system design while leaving your own staff time to complete its projects in a timely manner. Call Us Today At: 510.490.2300 Visit Our Website At: www.ascor-inc.com Or Email ASCOR At: sales@ascor-inc.com

S P E C I F I C A T I O N S Model No. Description Current Rating Crosstalk/Voltage General Purpose Switch Modules Series 3000 VXI Modules Bandwidth/ Switching Power Insertion Loss 3000-2 96 SPST relays rated @ 5 Amps 250VAC 5 Amps (individually wired) 3000-12 32 DPDT relays rated @ 2 Amps -80dB @ 300 KHz >55 MHz @ -3dB 2 Amps 3000-42 48 SPDT relays rated @ 5 Amps -62dB @ 1 MHz >50 MHz @ -3dB <-0.7dB @ 30 MHz 5 Amps 3000-43 48 SPDT 10 Amp relays 10 Amps 250 VAC 2000 VA (individually wired) 3000-53 96 Form C relays rated @ 2 Amp 220 VDC 60 W 1 Amp 3000-4357 32 SPDT, 5A Switches Replacement for Tektronix VX4357 3000-4351 40 SPDT, 10A Switches Replacement for Tektronix VX4351 3000-A308 80 OC Relay Drivers Replacement for Tektronix 73A308 3000-4353 32 SPST, 5A Switches Replacement for Tektronix VX4253 3000-4320 RF Switch, 8(1x4), 1.3GHz Replacement for Tektronix VX4320 Shielded Relay Scanner & Matrix Modules 3000-3 High Density Switch 1 Amp -50dB @ 10 MHz >35 MHz @ -3dB Multiplexer 120x1 3000-8 Up to 240x1 Single Wire 1 Amp -50dB @ 10 MHz >40 MHz @ -3dB Multiplexer 3000-9 High Density Switch 1 Amp -50dB @ 10 MHz >40 MHz @ -3dB Multiplexer 480x1 Single Wire 3000-34 GP Switch Matrix 2x128 1 Amp >40 MHz @ -3dB Single-Wire Reconfigurable to multiple 30x1s 3000-44 GP Switch Matrix 2x128 0.5 Amp -40dB @ 50 MHz >45 MHz @ -3dB -1dB @ 30 MHz 2-Wire 3000-45 GP Switch Matrix 4x64 0.5 Amp -40dB @ 50 MHz >70 MHz @ -3dB 2 -Wire 3000-46 GP Flex Switch Mixed 0.5 Amp >175 MHz@ -3dB Signals 3000-47 GP 8x32 Switch Matrix 0.5 Amp -42dB @ 100 MHz >90 MHz @-3dB 2-Wire 3000-52 GP 8x32 Switch Matrix 2 Amps -52dB @ 50 MHz >50 MHz @ -3dB 2-Wire (Unshielded Relays) 3000-57 GP 4x64 Matrix 2-Wire 2 Amps -52dB @ 50 MHz >40 MHz @ -3dB (Unshielded Relays) High Frequency Coax Switches 3000-5 High Frequency Coaxial 0.5 Amp -50dB @ 100 MHz >350 MHz @ -3dB -1dB @ 175 MHz Switch Matrix 36x2 3000-6 High Frequency Coaxial 0.5 Amp -50dB @ 100 MHz >350 MHz @ -3dB -1dB @ 175 MHz Switch Matrix 18x2 3000-30 Single Slot High 1 Amp -50dB @ 100 MHz >550 MHz @ -3dB -1dB @ 50 MHz Performance Coaxial Switch Matrix 3000-32 Variable Coax Multiplexer 1 Amp -50dB @ 100 MHz >900 MHz @ -3dB -1dB @ 50 MHz Switch 3000-39 Universal I/O Switch 0.5 Amp -50dB @ 100 KHz >700 MHz @ -3dB Module

S P E C I F I C A T I O N S Series 3000 VXI Modules Model No. Description Current Rating Crosstalk/Voltage Bandwidth/ Switching Power Insertion Loss Microwave & RF Switch Modules 3000-54 RF Switch Module DC to 1 Amp -37dB @ 1.3 GHz <-1.2dB @ 1.3 GHz 1.8 GHz 3000-55 Single/Dual 4x4 Matrix 1 Amp -35dB @ 1.3 GHz <-2.8dB @ 1.3 GHz Module 3000-2xx Microwave Switch Family 2W to 15W DC to 26 GHz -60dB @ 18 GHz <- 0.5dB @ 18 GHz Special Modules 3000-4 Relay & SSR Driver Module 128 General Purpose 0.5 Amp open collector drivers 3000-16 Guardian - VXI Alert Status Monitors up to 24 different indicators including VXI power supplies, Monitor watchdog timer, temperature, air flow etc. 3000-27 Multi-Channel 10 channels of programmable resistors, each channel programmable in Programmable Resistor 20 ohm steps up to 1.3 megaohms 3000-41 64 Channels of Edge 1 microsecond resolution on edge to edge measurement. Detection w/time Stamping Supports VXI interrupts 3000-48 16 Programmable High 4 Programmable timers each supporting 4 drivers. Power Drivers Each driver can support 4 Amps @ 50 Volts 3000-62 128 TTL I/O Compatible 128 TTL I/O latched tri-state drivers Driver 3000-62 Option 1 Additional 128 TTL drivers 3000-62 Option 2 Additional 32 channels of CMOS, 32 channels of differential and 32 channels of open collector drivers 3000-62 Option 3 Additional 64 channels of differential drivers 3000-62 Option 4 Additional 128 high current open collector drivers and 16 TTL drivers 3801-1004 Std. VXI DMM VXI DMM-AD/DC Voltage, Current, 2 and 4 Wire Resistance. with M-Module The 3801 also can add an industry standard M-Module to the Module. 3801-1005 VXI DMM/LCR with M-Module Same basic capabilities as the 3801-1004 with the additional features of Inductance, Capacitance, & t wire Resistance measurements. Also Temperature, Leakage, Peak-to Peak-Crest-& Median measurements, Timing Functions and AC/DC Voltage & Current Sourcing. The 3801 also can add an industry standard M-Module to the M Nodule. 3802-1004 Std VXI DMM only Same as 3801-1004 but without the M-Module capability 3802-1005 VXI DMM/LCR only Same as 3801-1005 but without the M-Module capability Quiet Ideas. Powerful Solutions. ASCOR, founded in 1987 and headquartered in California s Silicon Valley, provides a complete line of VXI and PXI Switching and Digital Modules for industrial, medical, scientific and governmental automatic test applications. ASCOR VXI and PXI products are the quietest, cleanest, highest density modules commercially available. Environmental Specifications Temperature -Operating 0 C to 55 C -Storage -40 to 75 C Relative Humidity -Operating 10 to 90% Non-condensing -Storage 0 to 95% Non-condensing The CE Mark indicates that the product(s) have completed and passed rigorous testing in the area of RF Emissions, Immunity to Electromagnetic Disturbances and that the product(s) comply with the European electrical safety standards. 4384 Enterprise Place, Fremont, CA 94538 Telephone: (510)490-2300, Fax: (510)490-8493 2002 ASCOR Incorporated. Specifications subject to change without notice. 9/02 Visit Our Website At: www.ascor-inc.com