NOTE TO USERS NI xx Pinout Labels for the SCB-100 Digital I/O Modules/Devices Using the 100-Pin Shielded Connector Block If you are using an NI xx (formerly referred to as DIO Series) digital I/O device or module with the SCB-100, you can print and attach a connector-specific pinout label to the cover of the connector block for easy connection reference. This document provides labels for the following models: NI 68 NI 69 NI NI NI NI NI NI 68 NI PCI-DIO-
Use the following label if you are connecting the SCB-100 to the NI 68 and PCI-DIO- models. Figure 1. NI 68/PCI-DIO- NI 68/PCI-DIO- ( I/O) MODELS *: No Connect 1 APC7 2 BPC7 3 APC6 4 BPC6 5 APC5 6 BPC5 7 APC4 8 BPC4 9 APC3 10 BPC3 BPB4 24 BPB3 BPB2 BPB1 BPB0 BPA7 BPA6 BPA5 BPA4 BPA3 BPA2 BPA1 BPA0 GND APB3 APB2 APB1 APB0 APA7 APA6 APA5 APA4 APA3 APA2 APA1 APA0 +5 V APC2 BPC2 APC1 BPC1 APC0 BPC0 APB7 BPB7 APB6 BPB6 APB5 BPB5 APB4 CPC7 DPC7 CPC6 DPC6 CPC5 DPC5 CPC4 DPC4 CPC3 DPC3 CPC2 DPC2 CPC1 DPC1 CPC0 DPC0 CPB7 67 DPB7 68 CPB6 69 DPB6 70 CPB5 71 DPB5 72 CPB4 73 DPB4 74 CPB3 75 DPB3 76 CPB2 77 DPB2 78 CPB1 79 DPB1 80 CPB0 81 DPB0 82 CPA7 DPA7 CPA6 DPA6 CPA5 DPA5 CPA4 DPA4 CPA3 DPA3 CPA2 DPA2 CPA1 DPA1 CPA0 DPA0 +5 V 99 GND 100 2 ni.com NI xx Pinout Labels for the SCB-100 Note To Users
Use the following label if you are connecting the SCB-100 to the NI 69 models. Figure 2. NI 69 NI 69 ( I/O) MODEL *: No Connect 1 2 3 4 P5.6 5 6 P5.5 7 8 P5.4 9 10 P5.3 24 P3.7 P3.6 P3.5 P3.4 GND P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0 +5 V P5.2 P5.1 P5.0 P8.7 P.7 P8.6 P.6 P8.5 P.5 P8.4 P.4 P8.3 P.3 P8.2 P.2 P8.1 P.1 P8.0 P.0 67 P10.7 68 69 P10.6 70 71 P10.5 72 73 P10.4 74 75 P10.3 76 77 P10.2 78 79 P10.1 80 81 P10.0 82 P9.7 P9.6 P9.5 P9.4 P9.3 P9.2 P9.1 P9.0 +5 V 99 GND 100 NI xx Pinout Labels for the SCB-100 Note To Users National Instruments 3
Use the following label if you are connecting the SCB-100 to the NI models. Figure 3. NI NI ( I/O) MODEL *: No Connect 1 P0.0 2 P0.1 3 P0.2 4 P0.3 5 P0.4 6 P0.5 7 P0.6 8 P0.7 9 10 24 P4.COM P4.COM P6.COM P6.COM P4.COM P4.COM P6.COM P6.COM P3.COM 71 P3.COM 72 P3.COM 73 P3.COM 74 75 P5.COM P5.COM P5.COM P5.COM P7.COM P7.COM P7.COM P7.COM 99 100 4 ni.com NI xx Pinout Labels for the SCB-100 Note To Users
Use the following label if you are connecting the SCB-100 to the NI models. Figure 4. NI NI ( I/O) MODEL *: No Connect 1 P0.0 2 P0.1 3 P0.2 4 P0.3 5 P0.4 6 P0.5 7 P0.6 8 P0.7 9 (P0.GND) 10 P0.VCC P2.VCC 24 P4.COM () P6.COM () P6.+5 V P0.VCC P0.VCC (P2.GND) P2.VCC P2.VCC (P1.GND) P1.VCC P1.VCC P1.VCC P3.COM (P3.GND) 71 P3.VCC 72 P3.VCC 73 P3.VCC 74 75 P5.COM () P7.COM (P7.GND) P7.VCC P7.VCC P7.VCC 99 P7.+5 V 100 NI xx Pinout Labels for the SCB-100 Note To Users National Instruments 5
Use the following label if you are connecting the SCB-100 to the NI models. Figure 5. NI NI ( I/O) MODEL *: No Connect 1 2 3 4 5 6 7 8 9 10 P0.0 P0.1 P0.2 P0.3 P0.4 P0.5 P0.6 P0.7 (P0.VCC) P0.GND P2.GND P4.COM () P6.COM () P6.+5 V 24 P0.GND P0.GND (P2.VCC) P2.GND P2.GND (P1.VCC) P1.GND P1.GND P1.GND P3.COM (P3.VCC) 71 P3.GND 72 P3.GND 73 P3.GND 74 75 P5.COM () P7.COM (P7.VCC) P7.GND P7.GND P7.GND 99 P7.+5 V 100 6 ni.com NI xx Pinout Labels for the SCB-100 Note To Users
Use the following label if you are connecting the SCB-100 to the NI models. Figure 6. NI NI ( I/O) MODEL *: No Connect 1 P0.0 2 P0.1 3 P0.2 4 P0.3 5 P0.4 6 P0.5 7 P0.6 8 P0.7 9 10 24 P4.COM () P6.COM () P6.+5 V P3.COM 71 P3.COM 72 P3.COM 73 P3.COM 74 75 P5.COM () P7.COM (P7.GND) P7.VCC P7.VCC P7.VCC 99 P7.+5 V 100 NI xx Pinout Labels for the SCB-100 Note To Users National Instruments 7
Use the following label if you are connecting the SCB-100 to the NI models. Note that the connector bank layout on the label differs from the actual connector bank layout on the SCB-100 hardware. Figure 7. NI NI ( I/O) MODEL *: No Connect 1 P0.0 2 P0.1 3 P0.2 4 P0.3 5 P0.4 6 P0.5 7 P0.6 8 P0.7 9 10 24 P4.COM () P6.COM () P6.+5 V P3.COM 71 P3.COM 72 P3.COM 73 P3.COM 74 75 P5.COM () P7.COM (P7.VCC) P7.GND P7.GND P7.GND 99 P7.+5 V 100 8 ni.com NI xx Pinout Labels for the SCB-100 Note To Users
Use the following label if you are connecting the SCB-100 to the NI 68/ models. Figure 8. NI 68/ NI 68/ ( I/O) MODELS *: No Connect 1 + 2-3 + 4-5 + 6-7 + 8-9 + 10 - - 24 - - - - P0.7- P0.6- P0.5- P0.4- P0.3- P0.2- P0.1- P0.0- GND + + + + P0.7+ P0.6+ P0.5+ P0.4+ P0.3+ P0.2+ P0.1+ P0.0+ +5 V P3.7+ P3.7- P3.6+ P3.6- P3.5+ P3.5- P3.4+ P3.4- + - + - + - + - + - + - + - + - + - + - + + - P5.6+ P5.6- P5.5+ P5.5- P5.4+ P5.4- P5.3+ P5.3- P5.2+ P5.2- P5.1+ P5.1- P5.0+ P5.0- + 67-68 + 69-70 + 71-72 + 73-74 + 75-76 + 77-78 + 79-80 + 81-82 +5 V 99 GND 100 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR.2-, DFAR 2.2-70, and DFAR 2.2-70. National Instruments. All rights reserved. 73A-01 Feb