Installation Guide. Rev

Similar documents
PoE Managed Midspan Solution for Standard Network Infrastructure

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

ebridge200b - Managed Two Port Transceiver Board

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

Rack Mount Power Supplies

Network Power Distribution Module

Active UTP Transceiver Hub with Integral Isolated Camera Power

iconverter 2-Module Power Chassis

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation.

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Product Features. Wireless Compliance: IEEE a Compliant IEEE b Compliant IEEE g Compliant IEEE n draft Compliant

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending

Features: Example of use

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Cabinet Interface Device

Hardened Web-Smart High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Industrial PoE Media Converter

DC Outdoor Power Supply/Chargers

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

Models HP Z VR Backpack G1 Dock

High Power over Ethernet Midspans PD Port Model PD Port Model

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Hardened PoE Ethernet Switch

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE

304TX-N. Phone: Fax: Web:

GV-POE2401-V2 24-Port 802.3at Web Management PoE

XPress-Pro SW User Guide

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

316TX-N. Phone: Fax: Web: -

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

TD-8616 ADSL2/2+ Ethernet Modem

Passive UTP Transceiver Hub Installation Guide

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

Quick Installation Guide DSL-2540U. ADSL Annex B/Ethernet Router with Built-in Switch

Summit Virtual Chassis Design and Installation Guide

Switched Rack Power Distribution Unit

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router

SPECTRUM. Merging infrastructure with emerging technology.

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Disclaimer. Note that the Midspan is designed for indoor use only.

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

PD-6506, PD & PD-6524

305FX-N. Phone: Fax: Web:

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ex-s1110-xt Gigabit Ethernet Extenders

114FX6. Phone: Fax: Web: -

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

4K8 8-port Ethernet 10/100 Switch, 4K-Series

GUIDE. EIPR Skorpion IP Router EIPR

Dynamic-UserCenter 32

MULTIBAND Dual Radio V4

Thermal Printer Configuration (EPSON)

4-Port Broadband user manual Model

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

NFD30 Network Dome Camera MPEG4 + Motion-JPEG Dual Mode, PoE, Audio, 300k CMOS, mm vari-focal lens Part No.:

10/100Base-TX Industrial Ethernet Extender

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300.

LightRules 2.7 Product Specifications

LevelOne FSW PoE Fast Ethernet Switch User Manual

Rugged MediaConverter

10/100Base-TX Industrial Ethernet Extender

BiPAC 8501/8521. SHDSL.bis (VPN) Firewall Bridge/Router. Quick Start Guide

Quick Start Guide. Installation. Physical Description.

308FX2-N. Phone: Fax: Web:

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

317FX-N. Phone: Fax: Web: -

exp-s1110pe PoE+ Gigabit Ethernet Extenders

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

TZ 170 Quick Start Guide

Signamax Connectivity Systems Industrial Ethernet Extender. User s Guide

XPress-Pro SW User Guide

Expandable Power Systems

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

IP Module Technical Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

702-W Industrial Wireless Radio N-Tron Networking Series

Automatic Link Verification and Restoral

Installation A B. Install each bracket using screws provided shown in Figure 1. Fix the KVM into the rack

Installation A B. Install each bracket using screws provided shown in Figure 1. Fix the KVM into the rack

FieldServer X-25 Start-Up Guide

Transcription:

Installation Guide Rev. 120913 NetWay4ES - 4-Port Managed /+ Switch NetWay4ESK - Kit includes: NetWay4ES and NetWay1E (84W Midspan Injector, 115VAC input) NetWay4ESKV - Kit includes: NetWay4ES and NetWay1EV (84W Midspan Injector, 230VAC input) I.T.E. 43KC Overview: NetWay4ES is a 4-Port Managed /+ switch which is designed for installation at the IDF (Intermediate Distribution Frame). NetWay4ES allows for system expansion by accommodating up to four (4) IP cameras/devices over a single CAT-5 or higher structured cable. Power up to 84W is provided by NetWay1E midspan injector or 30W by NetWay8/ NetWay16 midspan or any IEEE 802.3at standard midspan/endspan typically located at the MDF (Main Distribution Frame). Built-in IP management facilitates remote device reset/control and status monitoring. Agency Listings: UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved. Input: Up to 84W is provided by NetWay1E/1EV midspan injector or 30W by NetWay8/NetWay16 midspan or any IEEE 802.3at standard midspan/endspan. Power Output: Maximum power per port: + (30W). Total maximum power: NetWay4ES - + (30W). NetWay4ESK - 84W from Netway1E/1EV. Ethernet: Connectivity: RJ45, auto-crossover. Wire type: 4-pair CAT-5 or higher structured cable. Distance: up to 100m. Speed: 10/100BaseT, half/full duplex, auto negotiation. Features: LED Indicators: Yellow - IP Link status, Green - 10/100Base-T/active. Environmental: Operating Ambient Temperature : NetWay1E/1EV: -40ºC to 60ºC (-40ºF to 140ºF). NetWay4ES: 60W: -40ºC to 75ºC (-40ºF to 167ºF). Greater than 60W: -40ºC to 50ºC (-40ºF to 122ºF). Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF). Humidity: 20 to 85%, non-condensing. Applications: Remote installation and powering of a managed 4 port + switch. Star expansion of remote node to 4 + cameras/devices. Mechanical: Dimensions (H x W x D approx.): 1.7 x 5.23 x 8.42 (43.18mm x 132.84mm x 213.87mm) Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. Midspan or endspan and NetWay4ES is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The midspan or endspan injector and NetWay4ES are intended for indoor use only. 1. Midspan or endspan installation: Please refer to the corresponding installation instructions. 2. NetWay1E installation (Fig. 1, pg. 2): a. Affix rubber pads to NetWay1E for shelf installation (Fig. 6, pg. 7). b. Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWay1E unit. Plug unit into a reliable earth grounded socket. When using multiple units the sum of the individual name plate ratings should not exceed the supply circuit rating. Note: Do not connect to a receptacle controlled by a switch. c. Connect structured cable from UL Listed ethernet switch or video server to RJ45 jack marked [IN] on NetWay1E (Fig. 2, pg. 3). d. ON LED will illuminate indicating device is turned on (Fig. 2, pg. 3). e. Connect a device that will provide a low voltage trigger input to terminals marked [--- Shutdown +] (12VAC-24VAC or 5VDC-24VDC) ( Shutdown Voltage Range in Specifications). When voltage is applied, the output will drop to zero volts. When the voltage is removed from the shutdown terminals, the output will supply power to compliant devices (normal condition). Note: Return to normal operation from shutdown can take about 4 seconds. When is disabled devices may still present data signals on line pairs of the structured cable. NetWay4ES/NetWay4ESK - 1 -

3. NetWay4ES installation: a. Mounting: - Affix rubber pads to NetWay4ES for shelf installation (Fig. 6, pg. 7). b. Connect structured cable from NetWay4ES to RJ45 jack marked [OUT] to NetWay1E (Fig. 2, pg. 3) or midspan or endspan (Fig. 1, pg. 2). c. Connect IP cameras/devices to RJ45 jacks marked [1-4 Output 10/100BaseT] (Fig. 2, pg. 3). Parameter Input power requirements Indicators Environmental Conditions Regulatory Compliance Weights (approx.) Technical Specifications: Description Maximum power per port: + (30W) Total maximum power: Dependent on power from midspan or endspan. NetWay4ESK Maximum power per port: + (30W) Total maximum power: 84W Yellow (RJ45 connector): On - Linked, Off - No Link, Blinking - Activity. Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T. Operating Ambient Temperature (UL60950-1: NetWay1E/1EV: -40ºC to 60ºC (-40ºF to 140ºF). NetWay4ES: 60W: -40ºC to 75ºC (-40ºF to 167ºF). Greater than 60W: -40ºC to 50ºC (-40ºF to 122ºF). Relative humidity: 85%, +/ - 5% Storage Temperature: Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF). Operating Altitude: - 1000 to 6,561.679 ft. ( - 304.8 to 2000m). UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved. Product: 2.9 lbs. (1.32 kg), Shipping: 3.9 lbs. (1.77 kg) Typical Application: Fig. 1 - NetWay4ES powered by NetWay8 midspan. NetWay4ES (IDF) Output 10/100 Base-T INPUT Up to 100m max. Up to 100m max. Up to 100m max. Up to 100m max. 1 1 + 2 = maximum CAT-5 or higher structured cable distance 100m. NetWay midspan (MDF) 2 Ethernet Switch NVR Network Video Server (Head End Equipment) - 2 - NetWay4ES/NetWay4ESK

Typical Application: Fig. 2 - NetWay4ES powered by NetWay1E midspan injector. NetWay4ES (IDF) NetWay1E/1EV (MDF) Output 10/100 Base-T INPUT OUT IN Shutdown --- + ON Up to 100m max. Up to 100m max. Up to 100m max. Up to 100m max. 1 2 Ethernet Switch NVR Network Video Server (Head End Equipment) Input for Remote Manual Shutdown 1 + 2 = maximum CAT5e or high structured cable distance 100m. NetWay4ES User Interface and Programming: Note: A constant PC connection is not required for proper operations and is used as a local programming/monitoring tool only. Step 1. Set Local Area Connection of your laptop to DHCP mode. For Windows XP: a. Open Network Connections by clicking Start button, then clicking Settings, then clicking Network Connections. b. Right click the Local Area Connection. Click Properties. Administrator permission required If you are prompted for an administrator password or confirmation, type the password or provide confirmation. c. Double click Internet Protocol (TCP/IP) menu item. d. Choose the Obtain an IP address automatically option. e. Click OK. Close all windows. For Windows Vista: a. Open Network Connections by clicking the Start button Picture of the Start button, clicking Control Panel, clicking Network and Internet, clicking Network and Sharing Center, and then clicking Manage Network connections. b. Right click the Local Area Connection icon, and then click Properties. Administrator permission required If you are prompted for an administrator password or confirmation, type the password or provide confirmation. c. Click the Networking tab. Under this connection uses the following items, click either Internet Protocol Version 4 (TCP/IPv4) or Internet Protocol Version 6 (TCP/IPv6), and then click Properties. d. To specify IPv4 IP address settings, click Obtain an IP address automatically, and then click OK. e. To specify IPv6 IP address settings, click Obtain an IPv6 address automatically, and then click OK. For Windows 7: a. Open Network Connections by clicking the Start button Picture of the Start button, clicking Control Panel, clicking Network and Internet, clicking Network and Sharing Center, and then clicking Change Adapter Settings. b. Right click the Local Area Connection icon, and then click Properties. Administrator permission required If you are prompted for an administrator password or confirmation, type the password or provide confirmation. c. Click the Networking tab. Under this connection uses the following items, click either Internet Protocol Version 4 (TCP/IPv4) or Internet Protocol Version 6 (TCP/IPv6), and then click Properties. d. To specify IPv4 IP address settings, click Obtain an IP address automatically, and then click OK. e. To specify IPv6 IP address settings, click Obtain an IPv6 address automatically, and then click OK. Step 2. Connect a laptop or PC to the Ethernet port of your NetWay4ES unit, or connect your NetWay4ES and laptop/pc to a DHCP router if NetWay4ES is in DHCP mode. The NetWay4ES unit should be powered up at this moment. NetWay4ES/NetWay4ESK - 3 -

Step 3. Open a browser window (it is necessary to update your browser software to the latest version so that the pages display and function correctly). Step 4. Enter the NetWay8M/16M IP address (the default IP address is 192.168.168.168), or enter the NetWay4ES host name if in DHCP mode (default host name is NetWay4ES,) into the address bar. Status page will be displayed. Configuring NetWay4ES for network connection: Since every Network Configuration is different, please check with your Network Administrator to see if your NetWay4ES should use static IP addresses, or DHCP assigned IP addresses and/an Inbound Port assignment prior to setting up network connection. 1. Click Network Settings link. when prompted for an administrative password, type and submit the default password (11111111) (Fig. 3, pg. 4). 2. Network Setup page will be displayed. You may now configure your NetWay4ES for network connection. Fig. 4: NETWORK SETTING MENU. This menu is for configuring the NetWay4ES units for a network connection (Fig. 3, pg. 4). Fig. 3 Fig. 4 Network Type: Static IP DHCP IP Subnet Mask Inbound Port Host Name User can set a fixed IP for network connection. DHCP server in LAN will automatically an assign IP configuration for the network connection. This field shows the NetWay4ES current IP Address. A static IP address must be set manually. If DHCP this value will be assigned automatically. This field shows the subnet mask for your network so the NetWay4ES will be recognized within the network. If DHCP is selected, this value will be assigned automatically. Port number for HTTP/WEB communication. Name of the NetWay4ES device on the LAN Additional Information: 1. If using DHCP, all settings will be detected automatically. While DHCP is a useful tool for determining the network settings, if you set up your NetWay4ES in this manner its IP address may change at different times for different reasons, particularly after a power failure. If the IP address of the NetWay4ES changes, you may have difficulties accessing your NetWay4ES locally and/or remotely. It is strongly recommended that you connect via host name when units configured as DHCP. Please do not set the DHCP address issued to the NetWay4ES by the router as its static IP address unless you take specific steps that program your router to prevent such address conflicts. 2. If using a Static IP (recommended), you will need to input the information manually. In order for DDNS to work, you must enter valid data, compatible with your network, for all of the network setting fields: IP address, Subnet Mask, Inbound Port and Host Name. 3. If you are connecting through a router, make sure that you have opened up all the required network ports in the port forwarding section of your router s setup options. That is, you have directed the router to send any incoming traffic using those IP ports to the LAN IP address of the NetWay4ES. Useful information about router port forwarding can be found at www.portforward.com. Different routers may use different terms for port forwarding - 4 - NetWay4ES/NetWay4ESK

function. For instance, D-Link calls it virtual server, Netopia calls it pinholes. The default port for NetWay4ES is: 80 Note: Port 80 is the default port used for web browsing. Because of this, in order to prevent the average user from hosting a web server, most ISPs BLOCK traffic using port 80 from reaching the average site. If you only plan to monitor your NetWay4ES on a LAN, you can use port 80, and don t have to concern yourself with routers. However, if you desire remote access to your NetWay4ES, you MUST select functional ports and set up the port forwarding in your router. Other ports, such as 8080 and 8000 are sometimes blocked by ISPs as well. What port(s) should be used? There are 65,535 valid IP ports to choose from. These are broken down into three groups: Well Known Ports 0 through 1023. Registered Ports 1024 through 49151. Dynamic and/or Private Ports 49152 through 65535. So, rather than encounter a port conflict by choosing a port commonly used for another purpose (like port 25 for SMTP mail or port 448 for secure sockets), choose an unusual port number. For example, add 50,000 to your house number: 50,123 is less likely to lead to a port conflict. For a list of the known and registered ports, see http://www.iana.org/assignments/port-numbers. Configuring NetWay4ES ports: Fig. 5: SETUP MENU. This menu is for configuring the NetWay4ES ports (Fig. 5, pg. 5). Port Identification: Fig. 5 NetWay4ES allows you to identify each port (ID up to 8 characters). 1. Type the desired ID into the text box in the Device column (Fig. 5, pg. 5) for each corresponding port. 2. Click Save All Changes to save the changes or proceed with programming. port setup: Individual ports may be disabled if those ports are not used or to avoid the connection of unauthorized devices. 1. To disable one or more ports click on the Disable radio button(s) in the column (Fig. 5, pg. 5). 2. To enable one or more ports click on the Enable radio button(s) in the column (Fig. 5, pg. 5). Note: To enable all ports click on the Enable All link below column. 3. Click Save All Changes to save the changes or proceed with programming. Change Password: 1. Type the old password into the text box labeled Fig. 6 Enter Old Password (Fig. 6, pg. 5). 2. Type the new password into the text box labeled Enter New Password (Fig. 6, pg. 5). 3. Retype new password into text box labeled Confirm New Password (Fig. 6, pg. 5). 4. Click Submit to save the password (Fig. 6, pg. 5). 5. To disable password click Disable Passwortd button (Fig. 6, pg. 5). NetWay4ES/NetWay4ESK - 5 -

Fig. 5 NetWay4ES Chassis Mechanical Drawing & Dimensions (H x W x D approx.): 1.7 x 5.23 x 8.42 (43.18mm x 132.84mm x 213.87mm) 5.23 (132.84mm) 8.42 (213.87mm) Output 10/100 Base-T INPUT 1.7 (43.18mm) - 6 - NetWay4ES/NetWay4ESK

Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. ). 2- Place unit in desired location. Fig. 6 Left Side Mounting Hardware (Included): Four (4) rubber pads. C Rubber Pad NetWay4ES/NetWay4ESK - 7 -

Notes: Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IINetWay4ES E14O - 8 - NetWay4ES/NetWay4ESK MEMBER