BMXEHC0200 high speed counter module M340-2 channels

Similar documents
BMKC Controller for Power Tower, 8 DI 8 DO 2 HSC

BMXAMI0410 analog input module M340-4 inputs - high speed

BMXMSP0200 PTO module - 2 channels - 4 input - 24 V DC ma - 2 connectors 28 pins

TM3DI16G module TM3-16 inputs spring

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

TM238LFDC24DT compact base M I/O - 24 V DC supply - CANOpen - internal RAM 1000 kb

TM238LDD24DT compact base M I/O - 24 V DC supply -

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM3TI4 module TM3-4 inputs temperature

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

BMXCPS3020H power supply module X V isolated DC -

ABS2EC01EB input interface module mm - solid state - 24 V DC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

140ERT85420 multifunction input module Modicon Quantum - 32 I - IRIG-B - DCF77

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

TM221ME32TK controller M IO transistor PNP Ethernet

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

TM221CE40T controller M IO transistor PNP Ethernet

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

TM238LFDC24DT. Main. Discrete output voltage. Discrete input voltage type. Number of I/O expansion module 7 [Us] rated supply voltage

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

TM221M16R controller M IO relay

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

K1F006ALH cam switch - 6-pole A - screw mounting

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

RMCN22BD Analog Converter ma - for Zelio Analog

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM221CE24R controller M IO relay Ethernet

XGCS491B201 Standalone panel smart antenna

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

RE9RA21MW7 off-delay timing relay s V AC -

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

TM258LD42DT4L compact base M I/O - 24 V DC

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM241CE24T controller M IO transistor PNP Ethernet

XCMN2102L2 limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m

TWDLCAA10DRF extendable PLC base Twido V AC supply - 6 I 24 V DC - 4 O relay

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

TM258LF42DT compact base M I/O - 24 V DC - CANopen

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RM4TR31 three-phase network control relay RM4-T - range V

TWDLCAA16DRF extendable PLC base Twido V AC supply - 9 I 24 V DC - 7 O relay

TWDLCAE40DRF. Main. Range of product

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

XCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

TM241CE40R controller M IO relay Ethernet

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

RM4TA32 three-phase network control relay RM4-T - range V

VW3A3521S0 ATV IMC drive controller card type S solutions

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

TM3DI16 module TM3-16 inputs

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Transcription:

Product data sheet Characteristics BMXEHC0200 high speed counter module M340-2 channels Complementary Counter functions Cycle time Isolation voltage Input type Input voltage limits Input current Voltage state 1 guaranteed Current state 1 guaranteed Voltage state 0 guaranteed Current state 0 guaranteed Discrete output logic Output current limits Output voltage limits Maximum load current Main Range of product Product or component type Number of channels 2 Counting frequency Number of inputs 6 Modicon M340 automation platform Counter module <= 60000 Hz Input compatibility Incremental encoder with push-pull outputs 10...30 V totem pole 2-wire/3-wire proximity sensor 19.2...30 V Input voltage 24 V DC type 3 Number of outputs 2 Output voltage 32-bit counter counting Count events Down counting Frequency meter Loop (modulo) counting Measure time periods Ratio count Width modulation 1 ms 1500 V for 60 s 3 auxiliary input 3 high speed 30 V > 2 ma at 11 V 11...30 V 6 ma < 5 V < 1.5 ma Positive or negative configurable <= 0.5 A per ouput <= 2 A per module 19.2...30 V 1 A per module 0.5 A per ouput Leakage current <= 0.1 ma at state 0 Voltage drop < 3 V at state 1 Output overload protection Output short-circuit protection Overlap time Integrated 1.5 A integrated 0.2 ms 24 V DC Electrical connection 1 connector 16 pins for wiring the sensors of counter 1 1 connector 16 pins for wiring the sensors of counter 0 1 connector 10 pins for wiring auxiliary input and sensor power supply Current consumption Module format Product weight 80 ma 24 V DC sensor 40 ma 24 V DC rack 200 ma 3.3 V DC bus Standard 0.112 kg The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 9, 2013 1

Environment Ambient air temperature for operation 0...60 C Relative humidity 10...95 % without condensation IP degree of protection IP20 Protective treatment TC 2

Product data sheet Dimensions Drawings BMXEHC0200 Modules Mounted on Racks Dimensions (1) With removable terminal block (cage, screw or spring). (2) With FCN connector. (3) On AM1 ED rail: 35 mm wide, 15 mm deep. Only possible with BMXXBP0400/0400H/0600/0600H/0800/0800H rack. Rack references a in mm a in in. BMXXBP0400 and BMXXBP0400H 242.4 09.54 BMXXBP0600 and BMXXBP0600H 307.6 12.11 BMXXBP0800 and BMXXBP0800H 372.8 14.68 BMXXBP1200 and BMXXBP1200H 503.2 19.81 3

Product data sheet Connections and Schema BMXEHC0200 Counting Module Wiring Note The two 16-pin connectors and the 10-pin connector are sold separately and are available in the BMXXTSHSC20 connection kit. Assignment of the 16-Pin Connector Pin number Symbol Description 1, 2, 7, 8 24V_SEN 24 VDC output for sensors supply 5, 6, 13, 14 GND_SEN 24 VDC output for sensors supply 15, 16 FE Functional earth 3 IN_A Input A 4 IN_SYNC Synchronization input 9 IN_B Input B 10 IN_EN Enable input selected 11 IN_REF Homing input 12 IN_CAP Capture input Sensors Connection Example 1 IN_A input 2 IN_B input 3 IN_SYNC input (synchronization input) 4 IN_EN input (enable input) 4

Encoder Connection Example for Axis Control 1 Encoder (inputs A, B and Z) 2 IN_REF input (homing input) 3 IN_EN input (enable input) 4 IN_CAP input (capture input) Assignment of the 10-Pin Connector Pin number Symbol Description 1 24V_IN 24 VDC input for sensors supply 2 GND_IN Return 24 VDC input for sensors supply 5 Q0-1 Q1 output for counting channel 0 6 Q0-0 Q0 output for counting channel 0 7 Q1-1 Q1 output for counting channel 1 8 Q1-0 Q0 output for counting channel 1 9 24V_OUT 24 VDC input for actuators supply 10 GND_OUT Return 24 VDC input for actuators supply Connecting Outputs and Supplies 1 24 VDC supply for sensors 2 Return 24 VDC supply for sensors 3 Actuator for the Q0 output of counting channel 0 4 Actuator for the Q1 output of counting channel 0 5 Actuator for the Q0 output of counting channel 1 6 Actuator for the Q1 output of counting channel 1 The Q0 and Q1 outputs are limited by a maximum current of 0.5 A. 5

Recommended Circuit for high-noise Environment Using BMXXSP Electromagnetic Protection Kit 6