UP100-GSM. GSM based intercom and access control. Installation and user manual

Similar documents
UP200-GSM Intercom and access control unit operating on mobile GSM network

Comsec Protection Systems

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

GPRS Pager 3 INSTALATION AND USER MANUAL

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

Installation Manual & User Instructions. MultiCom 500

GSM HOME SECURITY SYSTEM

Installation Manual & User Instructions. MultiCom 100 / 500

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

Installation Manual & User Instructions

GSM communicator GD-06 Allegro Complete manual

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

8848 GSM FWT (GATEWAY) USER S MANUAL

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

User s Guide. Nokia is a registered trademark of Nokia Corporation, Finland Nokia Mobile Phones. All rights reserved.

MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

ProLine GSM. Installation manual

USER S MANUAL. Etross Printed for th edition

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

FWT-8818 GSM Gateway USER S MANUAL

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

NEOS3000A GSM Least Cost Wireless Router

The Packs Infotel. GSM Converter V2. Installation Manual V7

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

Quick Guide for SD-902 Door phone Intercom

Installation & User Manual For Cell Box Switch. GSM Cellular Gate opener and GSM alarm signalling device.

Fixed Wireless Phone. User Manual

HUAWEI FT2260 Home Phone Connect Quick Start

Follow me GSM PSTN gateway. User s manual. Model:P168 P190. CHOUQIN TECHNOLOGY LIMITED 1

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

SC-688 GSM FWT USER S MANUAL

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

A1000 GSM ALARM DEVICE

DP-222Q Color Video Door Phone Manual

MANUAL 3G GATE OPENER

: DOOR ENTRY UNIT. Programming Software USER MANUAL

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

GSM SECURITY AND CONTROL SYSTEM ESIM021

GSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007

DP-222Q Color Video Door Phone Manual

Voice Fax. User Manual

GSM Unit PU from software version Connecting cable RJ 12/ RJ 12, enclosed

Intercom User Manual v1.1

Voyager Mobile Entry Plus. (VME Plus) Installer Manual

2 WIRE video door entry system

EasyCon GSM. Installation manual

Aristel Networks Pty Ltd NEOS Port GSM / 3G* Fixed Wireless Terminal

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010.

DE EN. TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT

SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

GSM Intercom - QUICK START GUIDE

SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

GM-900 GSM/GPRS modem. Application manual

GSM Fixed Wireless Terminal WT User s Manual

Link GSM idp Manual v1.0

TELTONIKA ModemCOM/G10 (CM1100) User Manual V0.1

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

SMS Transceiver V3 User manual

JVA SMS Gateway User Manual

TELTONIKA ModemUSB/G10 User Manual v0.1

APPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

EA-GSM-Interface-GB.odt

TELTONIKA ModemCOM (TMC-10x) User Manual V

WT-1010C2 GSM ALARM SYSTEM

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

SMS Commander Manual

LEITRONIC AG Swiss Security Systems EA-GSM-DIN. GSM-Gateway

User's Manual for GSM Gateway(FWT) Model:ET-8264

MEITRACK MVT340 User Guide

FX INSTRUCTION MANUAL

GSM FAX Terminal-8848 User's Manual Version 1.1. GSM FAX Terminal User's Manual

jcmtechnologies GSM-CARD/VGSM-CARD user s manual communications card

Installation Manual & User Instructions

ModemUSB/E12 User Manual v0.1

USER S MANUAL FDC-250

NGP 822. Front view. 4 or 8 extensions or 2 cell phone interfaces or 2 interfaces of analogical lines. Automation and security

NEOS3000A GSM Least Cost Wireless Router

Wireless door phone INSTALLATION AND USER S GUIDE. Ed V11 AG 651 AG 652

KVM-301 / KVM-D301. [ Operating Installation Manual ]

C e l l C O M. G S M I n t e r c o m

RST100 Alert & Tracking Solutions

Call Types & Optional Services Voice Call

MEITRACK T333 User Guide

Transcription:

UP100-GSM GSM based intercom and access control Installation and user manual UP100-GSM REV.1.4 20/01/2014

Table of contents 1 Functions...3 2 Features...3 3 Application area...3 4 Operation...3 4.1 Visitor mode...3 4.2 Listen-in mode...4 4.3 Relay output control (gate opening)...4 4.4 Voltage output control (electric lock activation)...4 4.5 Forwarding incoming SMS messages...4 5 Settings...4 5.1 Response SMS explanation...5 6 LED indications...6 7 Installation...6 7.1 Mounting...6 7.2 Putting into operation...6 8 Wiring diagram...7 9 Surface mounting......8 10 Technical specification...8 2

The UP100-GSM is an intercom unit which as a cell phone can call the owner s mobile or landline phone. By pressing the call button on the intercom, it makes the voice connection in a few seconds, just like when talking via a conventional intercom system. This way it makes possible for the owner to receive the visitor s calls and talk to them at anytime and anywhere, even when not at home. The unit does not need internal handset, any special installation or complicated wiring, it needs power only and an active SIM card. 1 Functions Intercom Listen-in mode Electric door lock control via DTMF codes Electric gate control by free call SMS forwarding Programming through SMS message 2 Features GSM communication in full duplex mode 2 configurable phone number for communication 4 configurable phone numbers for electric gate control 1 relay output with independent N.O. contact, supports 1A@24V max. load 12V/1A voltage output with short circuit and overcurrent protection for electric lock control Local control of the voltage output using a separate input Supports prepaid SIM cards by forwarding the received balance information in SMS 3 Application area Wireless intercom Gate/door opener Emergency call device 4 Operation 4.1 Visitor mode When the visitor pushes the call button, the device initiates a voice call to the configured phone number. If the called party accepts the call, the communication establishes for the configured duration. During the call, the connection cannot be interrupted nor by making a call to the device, nor by pressing the button again. The call is ended automatically when the configured communication time expires, or the called party can hang up the call at anytime on his/her phone. The call is ended automatically if the called party does not answer or is not available. A new call is initiated only if the button is pressed again. A call to the second telephone number (if TEL2 is set) can be initiated (for 60 seconds) after the first call is ended, by pressing the call button on the intercom again or automatically, if AUTOCALL command is set. The maximum duration of the call is the same as in case of the first call. 3

4.2 Listen-in mode The intercom unit can be called from any phone number but the outputs can be controlled by the pre-set TEL or TEL2 telephone numbers. At the call the unit accepts the call without ringing and the voice connection establishes. The call can be ended on the caller s phone or by pressing the call button on the unit. If the call is initiated from a phone number which is configured in the unit as gate opener number, the device will consider the call as a gate opening call. In this case voice connection is not established, but the relay output is activated. To make a listen-in call from such phone number, use the #31# code in front of the number, this hides the caller s phone number (e.g.: #31#0036301234567). 4.3 Relay output control Depending on application, RELAY control output (normally open) can be activated in the following ways: control by free call: after identifying the telephone number of the incoming call the unit disconnects the procedure and activates the relay output. e.g. gate opening for which maximum 4 user telephone numbers can be set control by call button (BUTTON): the relay gets activated for the duration of pushing the call button e.g. possibility to connect existing doorbell control by the telephone s push button: while in call, it gets activated by 2# push button of the telephone. 4.4 Voltage output control OUT+ (VOLTAGE OUT) output control can be activated in the following ways: control by external contact: after input control the output gets active for the duration of the set time, e.g. inside opening button for the operation of magnetic lock control by the telephone s push button: while in call, it gets controlled and stays activated by 1# push button of the telephone for the duration of the set time, e.g. direct control of magnetic lock Voltage output is protected against short-circuit and overcurrent, so in case of excessing current limit the output turns off, then it operates again after the termination of the fault. 4.5 Forwarding incoming SMS messages The unit forwards the SMS messages received on its SIM card (e.g. balance information in case of a prepaid card) to the phone number set with the TEL command. After forwarding, the received message is deleted from the SIM card. If there is no phone number configured, the unit deletes the incoming messages without forwarding. A forwarded SMS message looks as follows: SMS forward from the sender s phone number : the forwarded message... 5 Settings Configuration of the unit is possible by sending the appropriate commands in SMS to the module s phone number. It is possible to send more commands (settings) in the same SMS, but the length of the message must not exceed 140 characters! Each message must begin with the password using the PWD=password# command and each command must end with # character, else the module does not apply the modifications. The following table contains the configuring and query commands: 4

PWD= 1234# PWC=new password# RESET# TEL=phone number# TEL2=phone number# RINGTIME= duration # TIME=duration# AUTOCALL=ON# AUTOCALL=OFF# RTIME= duration# VTIME= duration# RTEL= phone number# RTEL=BUTTON# STATUS?# Configuration commands Password for programming, default setting:1234 Changing the password. The password is a 4-digit number. Resetting the settings and the password to default. Setting the primary phone number to be called when pressing the button (in international format) Secondary telephone number in case the first telephone number is unavailable. Ringing time of the telephone (10-100 seconds) to restrict the reach of voice mail Maximal duration of the conversation. (60-600 seconds) Default setting: 60 seconds Automatic call of the second telephone number if the first telephone number is unavailable Duration of the relay output activation. (1-100 seconds) Default setting: 3 seconds Duration of the voltage output (- OUT +) activation. (1-100 seconds). Default setting: 5 seconds Setting the phone numbers for relay output activation. (max. 4 user) The relay gets activated for the duration of pushing the call button Query of the settings and the phone numbers set for relay output activation. Example: PWD=1234#TEL=00363012345678#TIME=120#RTEL=00363012345678# 5.1 Response SMS explanation After sending the configuration SMS, the unit sends back two SMS messages containing the modified setting and the phone numbers set for relay output activation. It sends the same messages when querying the status with the STATUS?# command, as shown in the following example: TEL: 00363012345678 the phone number called on button pressing: 00363012345678 CALL TIME: 120 conversation duration (limited to 120 seconds) SIGNAL: GOOD GSM signal (BAD / GOOD / EXCELLENT). If the indication is BAD, find a more suitable place for the unit or the GSM antenna, or a higher gain GSM antenna is necessary. RTEL: 00363012345678 phone number(s) authorized to activate the relay output. 5

6 LED indications GSM OK LED GSM / SIM ERROR Color green red Is lit if the unit is connected to the network and field strength is appropriate. Appropriate field strength: 2 (on the scale of 0-5) Is lit continuously if the unit is not connected to the network. The following cases are possible: - the GSM antenna is not connected or is faulty - the SIM card is not inserted, or PIN code request is not deactivated, or the card is faulty. CALL IN PROGRESS green Call or conversation is in progress. VOLTAGE OUT red Voltage output activated (e.g. electric lock control) RELAY CONTROL red Relay output activated (e.g. gate control) 7 Installation 7.1 Mounting Measure the GSM signal with your mobile phone. It may happen that in the desired place of installation the signal strength is not satisfactory. In this case you can move the unit or the GSM antenna in a more suitable place before installation. Do not mount the unit where it could be affected by strong electromagnetic disturbances. Do not mount the unit in wet places or in places with a high degree of humidity. Connecting the antenna: the GSM antenna can be connected to the SMA connector. The antenna supplied with the unit provides good transmission under normal reception circumstances. In case of having signal strength problems or/and wave interference (fading), use other type of antenna or find a more suitable place for the unit. Inserting the SIM card: turn the SIM card with the metallic contact surface downwards towards the panel, and the cut corner should point towards the panel s center. Insert the card in this position in the socket and press until it clicks. To remove the SIM card, push it towards the socket then pull it out. 7.2 Putting into operation Disable PIN code request, voicemail and missed call notification service on the SIM card. Enable caller identification and caller ID sending service on the SIM card at the GSM service provider. Make sure the SIM card is inserted properly into its socket. Make sure the antenna is fixed properly into the SMA connector. Make sure the wiring is done as shown in the wiring diagram. Power up the unit (12-24V AC/ DC). Make sure the power supply is sufficient for the operation of the unit. If operating from a 16V AC transformer, the necessary current is min. 300mA (5VA). 6

8 Wiring diagram 1. Call button input 2. Local input for voltage output control 3. Relay output - normally open contact (max. 24V DC/1A) 4. Voltage output 12V DC/1A 5. Supply voltage input 14-24V AC/DC 6. Speaker output 7. SIM card socket 8. GSM antenna connector (SMA type) 9. Status indicator LED s 10. Microphone input 11. USB connector (only for maintenance) 7

Surface mounting 9 Technical specification Supply voltage: 12-24V AC/DC Nominal consumption: 100mA Maximum consumption: 400mA @ 12VDC, 200mA @ 24VDC Max. load of the relay output: max. 1A @ 24V DC Voltage output / max. load: 12V DC / max. 1A Operating temperature: -30ºC - +70ºC Transmission frequency: GSM 900/1800 MHz (GSM 2G network) Contents of package: UP100-GSM unit, GSM antenna, security screws Warranty: 1 year 8